1.
Soft Matter ; 14(37): 7748-7758, 2018 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-30206610

RESUMO

The motion of two-filament artificial swimmers is modeled by assuming interfilament coupling via hydrodynamic viscous drag. The filaments are assumed to be in parallel and attached to a rigid spherical head. The boundary actuation is assumed to occur at the head-filament joint through an external oscillatory magnetic field and the filament motion is taken to be confined to the flexural plane. The hydrodynamic coupling modifies the viscous drag on one filament due to motion of the other. Assuming in-phase, small amplitude, low frequency actuation the swimmer performance metrics (propulsive thrust, propulsion speed and energy efficiency) are calculated using Lauga's formulation for the swimmer kinematics coupled with filament dynamics. The results are compared with the performance of a single-filament and an uncoupled two-filament swimmer. The hydrodynamic coupling is found to enhance the performance measures in a parametric window. Also, it is found that there occurs an optimum combination of head size and swimmer length that can maximize the microswimmer performance. The findings are in agreement with the experimental observations on multi-filament artificial microswimming.

2.
J Breath Res ; 13(1): 016003, 2018 10 30.
Artigo em Inglês | MEDLINE | ID: mdl-30045999

RESUMO

The paper presents a simulation study of breath analysis based on theoretical models of microelectromechanical structure (MEMS) cantilever sensor array. The purpose of this study is to suggest a methodology for the development of MEMS electronic nose (e-nose) for monitoring disease-specific volatiles in exhaled breath. Oxidative stress and diabetes are taken as case studies for the assessment of e-nose designs. The detection of ethane for general oxidative stress, isoprene for hypoxia, and acetone for diabetes are considered for targeted detection. A number of volatiles concurrently present in the exhaled breath are taken as interferents. The MEMS cantilevers are coated with volatile-selective polymers and are analyzed in both the static and dynamic modes. The sensor array is defined by polymer selections based on three data mining methods: principal component analysis (PCA), fuzzy c-means clustering (FCM), and fuzzy subtractive clustering (FSC). This utilizes vapor/polymer partition coefficients as a database. Analyses are carried out to find optimal combinations of the polymer selection method and cantilever sensing mode. Virtual breath analysis experiments are analyzed by PCA for target discrimination. It is found that no single combination works best in all conditions. The acetone (diabetes) detection is best in both sensing modes with the polymers selected by FSC; the isoprene (hypoxia) is detectable only in static sensing mode with polymers selected by FCM clustering; and the ethane (oxidative stress) detection is possible by all sensing modes and polymer selections, provided the breath samples are preconcentrated. This study suggests that it is difficult to realize a single general-purpose MEMS breath analyzer. The dedicated analyzers for specific disease indications can however be made with an optimal combination of sensing mode and polymer coatings.


Assuntos
Testes Respiratórios/instrumentação , Testes Respiratórios/métodos , Simulação por Computador , Nariz Eletrônico , Sistemas Microeletromecânicos/instrumentação , Análise por Conglomerados , Diabetes Mellitus/diagnóstico , Lógica Fuzzy , Humanos , Estresse Oxidativo , Polímeros/química , Análise de Componente Principal , Temperatura de Transição , Compostos Orgânicos Voláteis/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA