Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Rev Cardiovasc Med ; 24(11): 313, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39076441

RESUMO

Background: Right ventricular failure (RVF) is a significant cause of morbidity and mortality in patients with a left ventricular assist device (LVAD). This study is aimed to investigate the influence of a pectus excavatum on early and late outcomes, specifically RVF, following LVAD implantation. Methods: A retrospective study was performed, that included patients with a HeartMate 3 LVAD at our tertiary referral center. The Haller index (HI) was calculated using computed tomography (CT) scan to evaluate the chest-wall dimensions. Results: In total, 80 patients (median age 57 years) were included. Two cohorts were identified: 28 patients (35%) with a normal chest wall (HI < 2.0) and 52 patients (65%) with pectus excavatum (HI 2.0-3.2), with a mean follow-up time of 28 months. Early ( ≤ 30 days) RVF and early acute kidney injury events did not differ between cohorts. Overall survival did not differ between cohorts with a hazard ratio (HR) of 0.47 (95% confidence interval (CI): 0.19-1.19, p = 0.113). Late ( > 30 days) recurrent readmission for RVF occurred more often in patients with pectus excavatum (p = 0.008). The onset of late RVF started around 18 months after implantation and increased thereafter in the overall study cohort. Conclusions: Pectus excavatum is observed frequently in patients with a LVAD implantation. These patients have an increased rate of readmissions and late RVF. Further investigation is required to explore the extent and severity of chest-wall abnormalities on the risk of RVF.

2.
Eur J Vasc Endovasc Surg ; 66(3): 332-341, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37245796

RESUMO

OBJECTIVE: Acute type B aortic dissection (ATBD) is a rare yet serious cardiovascular event that potentially has an impact on health related quality of life (HRQoL). However, long term follow up data on this topic are scarce. This study aimed to review the long term HRQoL among patients treated for ATBD. METHODS: In this multicentre, cross sectional survey study, consecutive treated patients with ATBD between 2007 and 2017 in four referral centres in the Netherlands were retrospectively included and baseline data were collected. Between 2019 and 2021 the 36 Item Short Form Survey (SF-36) was sent to all surviving patients (n = 263) and was compared with validated SF-36 scores in the Dutch general population stratified by age and sex. RESULTS: In total, 144 of 263 surviving patients completed the SF-36 (response rate 55%). Median (IQR) age was 68 (61, 76) years at completion of the questionnaire, and 40% (n = 58) were female. Initial treatment was medical in 55% (n = 79), endovascular in 41% (n = 59), and surgical in 4% (n = 6) of ATBD patients. Median follow up time was 6.1 (range 1.7-13.9; IQR 4.0, 9.0) years. Compared with the general population, patients scored significantly worse on six of eight SF-36 subdomains, particularly physical domains. Apart from bodily pain, there were no substantial differences in HRQoL between male and female ATBD patients. Compared with sex matched normative data, females scored significantly worse on five of eight subdomains, whereas males scored significantly lower on six subdomains. Younger patients aged 41-60 years seemed more severely impaired in HRQoL compared with the age matched general population. Treatment strategy did not influence HRQoL outcomes. Follow up time was associated with better Physical and Mental Component Summary scores. CONCLUSION: Long term HRQoL was impaired in ATBD patients compared with the Dutch general population, especially regarding physical status. This warrants more attention for HRQoL during clinical follow up. Rehabilitation programmes including exercise and physical support might improve HRQoL and increase patients' health understanding.


Assuntos
Dissecção Aórtica , Qualidade de Vida , Humanos , Masculino , Feminino , Estudos Transversais , Estudos Retrospectivos , Inquéritos e Questionários , Dissecção Aórtica/cirurgia
3.
J Card Surg ; 35(6): 1220-1227, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32353903

RESUMO

BACKGROUND AND AIM OF THE STUDY: Transfusion of blood products after coronary artery bypass grafting (CABG) is associated with increased morbidity and mortality. We evaluated the perioperative use of blood products in patients undergoing CABG in our institution over the past two decades. METHODS: The study included 18 992 patients who underwent isolated CABG at our hospital between 1998 and 2017. Baseline characteristics of patients and the number of perioperative transfusions during their hospital stay (including red blood cells [RBCs], platelets, and fresh frozen plasma [FFP]) were assessed. Logistic regression models were used to identify risk factors for perioperative transfusion. RESULTS: The rates of perioperative RBC transfusion decreased for all patients undergoing isolated CABG (52.1% in 1998 vs 18.6% in 2017) in our institution. The mean number of transfused RBC units was significantly higher in women than in men (1.57 ± 2.2 vs 0.68 ± 1.84; P < .005); this difference remained significant over the years. After adjusting the results for other risk factors, female sex was a significant independent risk factor for perioperative RBC transfusion. The platelet transfusion rate increased over the past two decades (1.4% in 1998 vs 9.7% in 2017). The number of FFP transfusions remained unchanged. CONCLUSIONS: Over the past two decades, we observed a decrease in the incidence of perioperative RBC transfusions in patients undergoing isolated CABG, whereas platelet transfusions increased. Female sex was an independent predictor of perioperative RBC transfusion.


Assuntos
Ponte de Artéria Coronária/métodos , Ponte de Artéria Coronária/tendências , Transfusão de Eritrócitos/estatística & dados numéricos , Assistência Perioperatória/efeitos adversos , Assistência Perioperatória/métodos , Assistência Perioperatória/estatística & dados numéricos , Transfusão de Plaquetas/estatística & dados numéricos , Idoso , Transfusão de Eritrócitos/efeitos adversos , Transfusão de Eritrócitos/tendências , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Assistência Perioperatória/tendências , Transfusão de Plaquetas/efeitos adversos , Transfusão de Plaquetas/tendências , Fatores de Risco , Fatores Sexuais
4.
J Heart Valve Dis ; 23(3): 319-24, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-25296456

RESUMO

BACKGROUND AND AIM OF THE STUDY: Minimally invasive techniques for aortic valve replacement (AVR) have been developed as an alternative to conventional AVR for patients with high operative risk. Yet, these techniques are still associated with an increased risk of postoperative conduction disorders. The study aim was to identify the incidence and fate of postoperative conduction disorders in patients undergoing sutureless (SU) AVR with the Perceval S bioprosthesis. METHODS: In this observational study, patients who underwent SU AVR with the Perceval S prosthesis at the Catharina Hospital, Eindhoven, were analyzed. Electrocardiograms (ECGs) recorded at baseline, within 24 h postoperatively, before hospital discharge and at follow up were collected by reviewing patients' records. The ECGs were analyzed by two independent investigators to record QRS-duration and conduction disorders. RESULTS: All patients (n = 31) who underwent implantation of the Perceval S bioprosthesis between September 2010 and September 2012 were included. At baseline, three patients (9.7%) had preexisting left bundle branch block (LBBB), and one patient (3.2%) had a permanent pacemaker (PPM). New-onset LBBB developed in 11 patients (39.3%), and was transient in three patients (10.7%). Postoperatively, four patients (13.3%) required PPM implantation because of total atrioventricular block; all of these patients had either pre-existing LBBB (n = 1) or new LBBB (n = 3). CONCLUSION: Sutureless AVR with the Perceval S bioprosthesis was frequently complicated by new LBBB, which was persistent in the majority of patients. A relatively high incidence of postoperative PPM implantation was also observed.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bloqueio Atrioventricular/etiologia , Bioprótese/efeitos adversos , Bloqueio de Ramo/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Bloqueio Atrioventricular/terapia , Eletrocardiografia , Feminino , Humanos , Masculino , Marca-Passo Artificial , Desenho de Prótese , Fatores de Risco
5.
ASAIO J ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38896804

RESUMO

Hemocompatibility-related adverse events (HRAEs), particularly gastrointestinal bleeding, remain a frequent complication after left ventricular assist device (LVAD) implantation. The current study sought to describe and analyze whether early (<60 days) postoperative von Willebrand factor (VWF) activity assays predict the risk of gastrointestinal bleeding and stroke. A prospective single-center study including 74 HeartMate 3 device recipients between 2016 and 2023 was undertaken. The postoperative trajectory of the VWF profile was analyzed using linear mixed-effect models and Cox models were used to quantify associations between an early postoperative dip (≤0.7) in VWF activity assay measurements and late outcomes. Preoperatively, the mean VWF:Activity (Act)/Antigen (Ag) and VWF:Collagen Binding (CB)/Ag ratios were 0.94 (95% confidence interval [CI] = 0.81-1.02) and 0.95 (95% CI = 0.80-1.03), respectively, decreasing to 0.66 (95% CI = 0.57-0.73) and 0.67 (95% CI = 0.58-0.74) within 40 days (p < 0.05). In patients with VWF:CB/Ag and VWF:Act/Ag ratios ≤0.7 significantly more gastrointestinal bleeding (hazard ratio [HR]: 2.53; 95% CI = 1.1-5.8, and HR: 3.7; 95% CI = 1.5-9.2, respectively) and hemorrhagic stroke events (HR: 3.5; 95% CI = 1.6-7.6 and HR: 4.9; 95% CI = 2.1-11.7, respectively) were observed throughout the entire late (>60 days) postoperative period. In patients with VWF:Act/Ag ratio ≤0.7 less ischemic stroke events were observed (HR: 0.11; 95% CI = 0.01-0.85). In conclusion, VWF:Act/Ag and VWF:CB/Ag ratios ≤0.7 in the early postoperative phase can be used as biomarkers to predict HRAEs during long-term LVAD support.

6.
Artigo em Inglês | MEDLINE | ID: mdl-39087552

RESUMO

AIMS: Left ventricular assist devices (LVADs) are increasingly implanted in patients with advanced heart failure. Currently, LVAD care is predominantly concentrated at specialized tertiary care hospitals. The increasing workload and logistical burden for implanting centers poses significant challenges to access to care for individual patients in remote areas. An emerging approach to LVAD patient management is the use of a shared care model (SCM), which allows implanting centers to collaborate with local non-implanting hospitals. This scoping review explores and synthesizes the current scientific evidence on the use of an SCM in LVAD care management. METHODS: Eligible studies were identified in EMBASE, Pubmed MEDLINE, Web of Science, Cochrane, and Google Scholar. The PRISMA-ScR method was used to systematically synthesize findings. RESULTS: Of the 950 records screened, five articles met the inclusion criteria. Four review articles focused on the proposed benefits and challenges of using an SCM. Main benefits included improved patient satisfaction and continuity of care. Important challenges were initial education of non-implanting center staff and maintaining competency. One prospective study showed that absence of LVAD-specific care was associated with impaired survival and higher rates of pump thrombosis and LVAD-related infections. CONCLUSIONS: The use of an SCM is a promising approach in the long-term management of LVAD patients. However, sufficient evidence about the impact of an SCM on patients and the healthcare system is currently lacking. Standardized protocols based on prospective studies are needed to develop safe and effective shared care for LVAD patients.

7.
ASAIO J ; 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38595102

RESUMO

This study aimed to explore the potential impact of the angular position of the outflow graft on thromboembolic events and aortic valve regurgitation in people with a left ventricular assist device (LVAD). We analyzed contrast computed tomography (CT) data of patients with LVAD implantation between 2016 and 2021. Three-dimensional reconstructions of the outflow graft and aortic arch were performed to calculate the horizontal (azimuth) angle and vertical (polar) angle, as well as the relative distance between the outflow graft, aortic valve, and brachiocephalic artery. Among 59 patients (median age 57, 68% male), a vertical angle ≥107° correlated significantly with increased cerebrovascular accidents (hazard ratio [HR]: 5.8, 95% confidence interval [CI]: 1.3-26.3, p = 0.022) and gastrointestinal bleeding (HR: 3.4, 95% CI: 1.0-11.2, p = 0.049) during a median 25 month follow-up. No significant differences were found between the vertical angle and aortic valve regurgitation or survival. The horizontal angle and relative distance did not show differences regarding clinical adverse events. This study emphasizes the importance of the LVAD outflow graft angular position to prevent life-threatening thromboembolic events. This study suggests the need for prospective research to further validate these findings.

8.
J Cardiovasc Med (Hagerstown) ; 25(1): 44-50, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-38079280

RESUMO

AIMS: This retrospective study investigated the association between anatomical variations in the aortic arch branching and adverse events, including the risk of cerebrovascular accidents (CVAs), in patients with a left ventricular assist device (LVAD). METHODS: Medical charts were reviewed for all patients with HeartMate 3 LVAD support at our center from 2016 to 2021. Computed tomography scans were evaluated to categorize the variations in the aortic arch branching based on seven different types, as described in the literature. RESULTS: In total, 101 patients were included: 86 (85.1%) with a normal branching pattern and 15 (14.9%) with an anatomical variation. The following variations were observed: eight (7.9%) with a bovine arch and seven (6.9%) with a left vertebral arch. The median age was 57 years, 77.2% were men, and the median follow-up was 25 months. No difference was found in the rate of early (< 30 days) re-exploration due to bleeding after LVAD implantation. The rate of CVA and mortality did not differ significantly between patients with a normal arch or an anatomical variation during follow-up, with hazard ratios of 1.47 [95% confidence interval (CI): 0.48-4.48; P = 0.495] and 0.69 (95% CI: 0.24-1.98; P = 0.489), respectively. CONCLUSION: This preliminary study showed no differences in early and long-term adverse events, including CVA, when comparing patients with a variation in the aortic arch branching to patients with a normal aortic arch. However, knowledge of the variations in aortic arch branching could be meaningful during cardiac surgery for potential differences in surgical events in the perioperative period.


Assuntos
Coração Auxiliar , Acidente Vascular Cerebral , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Aorta Torácica/diagnóstico por imagem , Coração Auxiliar/efeitos adversos , Tomografia Computadorizada por Raios X , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia
9.
J Clin Med ; 12(5)2023 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-36902802

RESUMO

BACKGROUND: No clear guidelines exist for performing preventive surgery for ascending aortic (AA) aneurysm in elderly patients. This study aims to provide insights by: (1) evaluating patient and procedural characteristics and (2) comparing early outcomes and long-term mortality after surgery between elderly and non-elderly patients. METHODS: A multicenter retrospective observational cohort-study was performed. Data was collected on patients who underwent elective AA surgery in three institutions (2006-2017). Clinical presentation, outcomes, and mortality were compared between elderly (≥70 years) and non-elderly patients. RESULTS: In total, 724 non-elderly and 231 elderly patients were operated upon. Elderly patients had larger aortic diameters (57.0 mm (IQR 53-63) vs. 53.0 mm (IQR 49-58), p < 0.001) and more cardiovascular risk factors at the time of surgery than non-elderly patients. Elderly females had significantly larger aortic diameters than elderly males (59.5 mm (55-65) vs. 56.0 mm (51-60), p < 0.001). Short-term mortality was comparable between elderly and non-elderly patients (3.0% vs. 1.5%, p = 0.16). Five-year survival was 93.9% in non-elderly patients and 81.4% in elderly patients (p < 0.001), which are both lower than that of the age-matched general Dutch population. CONCLUSION: This study showed that in elderly patients, a higher threshold exists to undergo surgery, especially in elderly females. Despite these differences, short-term outcomes were comparable between 'relatively healthy' elderly and non-elderly patients.

10.
Eur J Cardiothorac Surg ; 62(4)2022 09 02.
Artigo em Inglês | MEDLINE | ID: mdl-35993906

RESUMO

OBJECTIVES: This retrospective study investigated the correlation between the angular position of the left ventricular assist device (LVAD) inflow cannula and relapsing low-flow alarms. METHODS: Medical charts were reviewed of all patients with HeartMate 3 LVAD support for relapsing low-flow alarms. A standardized protocol was created to measure the angular position with a contrast-enhanced computed tomography scan. Statistics were done using a gamma frailty model with a constant rate function. RESULTS: For this analysis, 48 LVAD-supported patients were included. The majority of the patients were male (79%) with a median age of 57 years and a median follow-up of 30 months (interquartile range: 19-41). Low-flow alarm(s) were experienced in 30 (63%) patients. Angulation towards the septal-lateral plane showed a significant increase in low-flow alarms over time with a constant rate function of 0.031 increase in low-flow alarms per month of follow-up per increasing degree of angulation (P = 0.048). When dividing this group using an optimal cut-off point, a significant increase in low-flow alarms was observed when the septal-lateral angulation was 28° or more (P = 0.001). Anterior-posterior and maximal inflow cannula angulation did not show a significant difference. CONCLUSIONS: This study showed an increasing number of low-flow alarms when the degrees of LVAD inflow cannula expand towards the septal-lateral plane. This emphasizes the importance of the LVAD inflow cannula angular position to prevent relapsing low-flow alarms with the risk of diminished quality of life and morbidity.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Cânula , Feminino , Insuficiência Cardíaca/cirurgia , Ventrículos do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
11.
Eur J Cardiothorac Surg ; 62(4)2022 09 02.
Artigo em Inglês | MEDLINE | ID: mdl-36111410

RESUMO

OBJECTIVES: This retrospective study investigated the correlation between the angular position of the left ventricular assist device (LVAD) inflow cannula and relapsing low-flow alarms. METHODS: Medical charts were reviewed of all patients with HeartMate 3 LVAD support for relapsing low-flow alarms. A standardized protocol was created to measure the angular position with a contrast-enhanced computed tomography scan. Statistics were done using a gamma frailty model with a constant rate function. RESULTS: For this analysis, 48 LVAD-supported patients were included. The majority of the patients were male (79%) with a median age of 57 years and a median follow-up of 30 months (interquartile range: 19-41). Low-flow alarm(s) were experienced in 30 (63%) patients. Angulation towards the septal-lateral plane showed a significant increase in low-flow alarms over time with a constant rate function of 0.031 increase in low-flow alarms per month of follow-up per increasing degree of angulation (P = 0.048). When dividing this group using an optimal cut-off point, a significant increase in low-flow alarms was observed when the septal-lateral angulation was 28° or more (P = 0.001). Anterior-posterior and maximal inflow cannula angulation did not show a significant difference. CONCLUSIONS: This study showed an increasing number of low-flow alarms when the degrees of LVAD inflow cannula expand towards the septal-lateral plane. This emphasizes the importance of the LVAD inflow cannula angular position to prevent relapsing low-flow alarms with the risk of diminished quality of life and morbidity.


Assuntos
Coração Auxiliar , Cânula , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
12.
Scand Cardiovasc J ; 45(6): 379-84, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21854091

RESUMO

OBJECTIVES: Minimal access aortic valve replacement (AVR) has been demonstrated to have beneficial effects over median sternotomy. Minimal extracorporeal circulation (MECC) has been shown to have less deleterious effects than conventional cardiopulmonary bypass. We describe for the first time AVR via upper J-shaped partial sternotomy compared to median sternotomy using MECC. METHODS: Prospectively collected pre-operative, intra-operative, post-operative and follow-up data from 104 consecutive patients who underwent minimal access AVR were compared to 72 consecutive patients undergoing median sternotomy using MECC during the same period (January 2007 to December 2009). RESULTS: No significant differences were found in patient's characteristics or intra-operative data with the exception of pre-existing pulmonary disease. The mean cardiopulmonary bypass (86 ± 18 min vs. 78 ± 15 min, p = 0.0079) and cross-clamp times (65 ± 13 min vs. 59 ± 12 min, p = 0.0013) were significantly shorter in the median sternotomy group. Mediastinal blood loss (397 ± 257 ml vs. 614 ± 339 ml, p < 0.0001) and ventilation time (8 ± 6.9 h vs. 11 ± 16.5 h, p = 0.0054) were significantly less in the minimal access group. No differences were seen in transfusion requirements, inotropic support, intensive care unit (ICU) stay, total hospital stay, post-operative haemoglobin drop, major events or mortality. Quality of life scores after discharge demonstrated less pain with a quicker recovery and return to daily activities in patients receiving J-shaped sternotomy. CONCLUSIONS: Minimal access AVR using MECC is feasible and provides excellent clinical results. Less pain and quicker recovery was experienced among patients in this group.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Ponte Cardiopulmonar , Implante de Prótese de Valva Cardíaca , Esternotomia/métodos , Atividades Cotidianas , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Ponte Cardiopulmonar/efeitos adversos , Distribuição de Qui-Quadrado , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Unidades de Terapia Intensiva , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Países Baixos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Estudos Prospectivos , Qualidade de Vida , Recuperação de Função Fisiológica , Respiração Artificial , Esternotomia/efeitos adversos , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento
13.
Artigo em Inglês | MEDLINE | ID: mdl-34559960

RESUMO

This video tutorial summarizes the main steps of the conventional open surgical technique for harvesting the radial artery as a coronary artery bypass graft, taking anatomic and surgical aspects into account.


Assuntos
Artéria Radial , Coleta de Tecidos e Órgãos , Ponte de Artéria Coronária , Humanos , Artéria Radial/cirurgia
15.
Interact Cardiovasc Thorac Surg ; 11(6): 754-7, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20847068

RESUMO

Isolated aortic valve replacement (AVR) or coronary artery bypass grafting (CABG) using minimized extracorporeal circulation (MECC) has been shown to have less deleterious effects than standard cardiopulmonary bypass (CPB). In this prospective cohort study, we evaluated and compared clinical results of combined AVR with CABG using MECC. We prospectively collected preoperative, intraoperative, postoperative and follow-up data of 65 patients who underwent combined AVR with CABG using MECC and compared these with 135 patients undergoing combined AVR with CABG using standard CPB. No significant differences were seen in patients demographic characteristics or intraoperative data. Patients in the MECC group experienced a smaller preoperative haemoglobin drop (4.5±0.8 g/dl vs. 5.0±0.5 g/dl, P=0.002) resulting in higher haemoglobin at discharge (11.3±1.3 g/dl vs. 10.8±1.1 g/dl, P=0.03). They had decreased blood products requirements (P=0.004) compared to patients in the standard CPB group. No differences were noted in pulmonary complications, neurological events or mortality. We present for the first time data showing that combined AVR with CABG using MECC is feasible and provides better clinical results compared to standard CPB with regard to blood products requirements, without compromising operative morbidity or mortality.


Assuntos
Valva Aórtica/cirurgia , Ponte Cardiopulmonar , Ponte de Artéria Coronária , Circulação Extracorpórea , Implante de Prótese de Valva Cardíaca , Idoso , Idoso de 80 Anos ou mais , Transfusão de Sangue , Ponte Cardiopulmonar/efeitos adversos , Ponte Cardiopulmonar/mortalidade , Distribuição de Qui-Quadrado , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/mortalidade , Circulação Extracorpórea/efeitos adversos , Circulação Extracorpórea/mortalidade , Estudos de Viabilidade , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Razão de Chances , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA