Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Radiographics ; 42(2): 469-486, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35061517

RESUMO

Mucin-producing neoplasms in the abdomen and pelvis are a distinct entity, separate from simple fluid-containing neoplasms and loculated fluid collections. Mucin is a thick gelatinous substance and-owing to its high water content-has imaging features that can be mistaken for those of simple fluid-containing neoplasms with multiple imaging modalities. However, mucin-producing neoplasms arise from specific organs in the abdomen and pelvis, with unique imaging appearances, knowledge of which is important to guide accurate diagnosis and management. With its large field of view and high soft-tissue resolution, MRI has advantages over other imaging modalities in characterizing these neoplasms. The authors focus on the spectrum of MRI features of such mucin-producing neoplasms and illustrate how-despite a varied organ origin-some of these neoplasms share similar MRI and histopathologic features, thereby helping narrow the differential diagnosis. One common finding in these tumors is that the presence of internal complexity and solid enhancing components increases as the degree of malignant transformation increases. Lack of internal complexity generally indicates benignity. These tumors have a varied range of prognosis; for example, a low-grade appendiceal mucinous neoplasm is indicative of a good prognosis, while a mucinous tumor of the rectum is known to manifest at an early age with aggressive behavior and poorer prognosis compared with its nonmucinous counterpart. Online supplemental material is available for this article. ©RSNA, 2022.


Assuntos
Cavidade Abdominal , Neoplasias do Apêndice , Cavidade Abdominal/patologia , Neoplasias do Apêndice/diagnóstico por imagem , Neoplasias do Apêndice/patologia , Humanos , Imageamento por Ressonância Magnética , Mucinas , Pelve/diagnóstico por imagem , Pelve/patologia
2.
J Magn Reson Imaging ; 51(3): 854-860, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31410924

RESUMO

BACKGROUND: More than 100 million adults in the US suffer from prediabetes or type-2 diabetes. Noninvasive imaging of pancreas endocrine function might provide a surrogate marker of ß-cell functional integrity loss linked to this disease. PURPOSE: To noninvasively assess pancreatic blood-flow modulation following a glucose challenge using arterial spin labeling (ASL) MRI. STUDY TYPE: Prospective. SUBJECTS: Fourteen adults (30 ± 7 years old, 3M/11F, body mass index [BMI] = 24 ± 3 kg.m-2 ). FIELD STRENGTH/SEQUENCE: 3T MRI / background-suppressed pseudocontinuous PCASL preparation with single-shot fast-spin-echo (FSE) readout before and after an oral glucose challenge using either fruit juice (n = 7) or over-the-counter glucose gel (n = 7). ASSESSMENT: Subjects were fasting prior to initiation of oral stimulation, then dynamic perfusion measurements were performed every 2 minutes for 30 minutes. We quantified absolute blood flow at each timepoint. STATISTICAL TESTS: Repeated-measures analysis of variance (ANOVA) followed by paired t-tests to assess for a significant effect of glucose challenge on measured perfusion. RESULTS: Measured basal blood flow was 187 ± 53 mL/100g/min. A significant blood flow increase of +38 ± 26% was observed 10 minutes poststimulation (P < 0.05) and continuing until the end of the experiment. The gel stimulation provided the most consistent results, with an early rise followed by an additional later increase consistent with the known pancreatic insulin response to elevated blood glucose. Across-subject variations in blood flow increase were partially attributable to basal flow, with a negative correlation of r = -0.84 between basal and maximal relative flow increase in the gel group. DATA CONCLUSION: ASL can be used to measure pancreatic flow in response to a glucose challenge, which could be linked to insulin release and secretion. This paradigm might be useful to characterize disorders of glucose regulation. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2020;51:854-860.


Assuntos
Glucose , Imageamento por Ressonância Magnética , Pâncreas/diagnóstico por imagem , Perfusão , Estudos Prospectivos , Marcadores de Spin
3.
Eur Radiol ; 30(8): 4686-4694, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32221682

RESUMO

OBJECTIVES: Staging of upper extremity lymphedema is needed to guide surgical management, but is not standardized due to lack of accessible, quantitative, or precise measures. Here, we established an MRI-based staging system for lymphedema and validate it against existing clinical measures. METHODS: Bilateral upper extremity MRI and lymphoscintigraphy were performed on 45 patients with unilateral secondary lymphedema, due to surgical intervention, who were referred to our multidisciplinary lymphedema clinic between March 2017 and October 2018. MRI short-tau inversion recovery (STIR) images were retrospectively reviewed. A grading system was established based on the cross-sectional circumferential extent of subcutaneous fluid infiltration at three locations, labeled MRI stage 0-3, and was compared to L-Dex®, ICG lymphography, volume, lymphedema quality of life (LYMQOL), International Society of Lymphology (ISL) stage, and lymphoscintigraphy. Linear weighted Cohen's kappa was calculated to compare MRI staging by two readers. RESULTS: STIR images on MRI revealed a predictable pattern of fluid infiltration centered on the elbow and extending along the posterior aspect of the upper arm and the ulnar side of the forearm. Patients with higher MRI stage were more likely to be in ISL stage 2 (p = 0.002) or to demonstrate dermal backflow on lymphoscintigraphy (p = 0.0002). No correlation was found between MRI stages and LYMQOL. Higher MRI stage correlated with abnormal ICG lymphography pattern (rs = 0.63, p < 0.0001), larger % difference in limb volume (rs = 0.68, p < 0.0001), and higher L-Dex® ratio (rs = 0.84, p < 0.0001). Cohen's kappa was 0.92 (95% CI, 0.85-1.00). CONCLUSION: An MRI staging system for upper extremity lymphedema offers an improved non-invasive precision marker for lymphedema for therapeutic planning. KEY POINTS: • Diagnosis and staging of patients with secondary upper extremity lymphedema may be performed with non-contrast MRI, which is non-invasive and more readily accessible compared to lymphoscintigraphy and evaluation by lymphedema specialists. • MRI-based staging of secondary upper extremity lymphedema is highly reproducible and could be used for long-term follow-up of patients. • In patients with borderline clinical measurements, MRI can be used to identify patients with early-stage lymphedema.


Assuntos
Linfedema/diagnóstico , Linfografia/métodos , Imageamento por Ressonância Magnética/métodos , Qualidade de Vida , Estudos Transversais , Feminino , Humanos , Linfedema/etiologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Índice de Gravidade de Doença , Extremidade Superior
5.
J Hum Evol ; 96: 113-33, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27343775

RESUMO

This study utilises geochemical provenancing of silcrete raw materials, in combination with chaîne opératoire analyses, to explore lithic procurement and behavioural patterns in the northern Kalahari Desert during the Middle Stone Age (MSA). New data from the sites of Rhino Cave, Corner Cave, and ≠Gi in northwest Botswana, combined with earlier results from White Paintings Shelter, reveal that the long distance transport of silcrete for stone tool manufacture was a repeated and extensively used behaviour in this region. Silcrete was imported over distances of up to 295 km to all four sites, from locations along the Boteti River and around Lake Ngami. Significantly, closer known sources of silcrete of equivalent quality were largely bypassed. Silcrete artefacts were transported at various stages of production (as partially and fully prepared cores, blanks, and finished tools) and, with the exception of ≠Gi, in large volumes. The import occurred despite the abundance of locally available raw materials, which were also used to manufacture the same tool types. On the basis of regional palaeoenvironmental data, the timing of the majority of silcrete import from the Boteti River and Lake Ngami is constrained to regionally drier periods of the MSA. The results of our investigation challenge key assumptions underlying predictive models of human mobility that use distance-decay curves and drop-off rates. Middle Stone Age peoples in the Kalahari appear to have been more mobile than anticipated, and repeatedly made costly choices with regard to both raw material selection and items to be transported. We conclude that (i) base transport cost has been overemphasised as a restrictive factor in predictive models, and (ii) factors such as source availability and preference, raw material quality, and potential sociocultural influences significantly shaped prehistoric landscape use choices.


Assuntos
Arqueologia , Sedimentos Geológicos/análise , Meios de Transporte , Animais , Botsuana , Clima , Meio Ambiente , Hominidae , Humanos , Tecnologia
6.
AJR Am J Roentgenol ; 204(4): 758-67, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25794064

RESUMO

OBJECTIVE: The purpose of this article is to review infectious, inflammatory, and auto-immune-mediated processes in the gastrointestinal system where diffusion-weighted imaging can be helpful as well as pitfalls associated with its use. CONCLUSION: Diffusion-weighted imaging has become an important and widely used tool in abdominal and pelvic MRI, but it has been used primarily for oncologic applications. As more body MRI protocols are routinely including diffusion-weighted imaging, this sequence can be useful in evaluating an increasing number of nononcologic processes.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Gastroenteropatias/diagnóstico , Artefatos , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos
7.
AJR Am J Roentgenol ; 205(3): 469-78, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26295633

RESUMO

OBJECTIVE: The purpose of this study was to determine the incidence of nephrogenic systemic fibrosis (NSF) in patients with chronic kidney disease (CKD) and moderate-to-severe impairment of kidney function who had not previously been exposed to gadolinium-based contrast agents (GBCAs) or referred to undergo contrast-enhanced MRI with gadobenate dimeglumine or gadoteridol. SUBJECTS AND METHODS: Two multicenter prospective cohort studies evaluated the incidence of unconfounded NSF in patients with stage 3 CKD (estimated glomerular filtration rate [eGFR] in cohort 1, 30-59 mL/min/1.73 m(2)) or stage 4 or 5 CKD (eGFR in cohort 2, < 30 mL/min/1.73 m(2)) after injection of gadobenate dimeglumine (study A) or gadoteridol (study B). A third study (study C) determined the incidence of NSF in patients with stage 4 or 5 CKD who had not received a GBCA in the 10 years before enrollment. Monitoring for signs and symptoms suggestive of NSF was performed via telephone at 1, 3, 6, and 18 months, with clinic visits occurring at 1 and 2 years. RESULTS: For studies A and B, the populations evaluated for NSF comprised 363 and 171 patients, respectively, with 318 and 159 patients in cohort 1 of each study, respectively, and with 45 and 12 patients in cohort 2, respectively. No signs or symptoms of NSF were reported or detected during the 2 years of patient monitoring. Likewise, no cases of NSF were reported for any of the 405 subjects enrolled in study C. CONCLUSION: To our knowledge, and consistent with reports in the literature, no association of gadobenate dimeglumine or gadoteridol with unconfounded cases of NSF has yet been established. Study data confirm that both gadoteridol and gadobenate dimeglumine properly belong to the class of GBCAs considered to be associated with the lowest risk of NSF.


Assuntos
Meios de Contraste/efeitos adversos , Compostos Heterocíclicos/efeitos adversos , Falência Renal Crônica/complicações , Imageamento por Ressonância Magnética , Meglumina/análogos & derivados , Dermopatia Fibrosante Nefrogênica/induzido quimicamente , Compostos Organometálicos/efeitos adversos , Adolescente , Adulto , Idoso , Feminino , Gadolínio/efeitos adversos , Humanos , Testes de Função Renal , Masculino , Meglumina/efeitos adversos , Pessoa de Meia-Idade , Dermopatia Fibrosante Nefrogênica/epidemiologia , Vigilância de Produtos Comercializados , Estudos Prospectivos , Fatores de Risco
8.
Radiographics ; 35(6): 1722-37, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26466181

RESUMO

Magnetic resonance (MR) imaging can provide critical diagnostic and anatomic information while avoiding the use of ionizing radiation, but it has a unique set of safety risks associated with its reliance on large static and changing magnetic fields, high-powered radiofrequency coil systems, and exogenous contrast agents. It is crucial for radiologists to understand these risks and how to mitigate them to protect themselves, their colleagues, and their patients from avoidable harm and to comply with safety regulations at MR imaging sites. Basic knowledge of MR imaging physics and hardware is necessary for radiologists to understand the origin of safety regulations and to avoid common misconceptions that could compromise safety. Each of the components of the MR imaging unit can be a factor in injuries to patients and personnel. Safety risks include translational force and torque, projectile injury, excessive specific absorption rate, burns, peripheral neurostimulation, interactions with active implants and devices, and acoustic injury. Standards for MR imaging device safety terminology were first issued in 2005 and are required by the U.S. Food and Drug Administration, with devices labeled as "MR safe," "MR unsafe," or "MR conditional." MR imaging contrast agent safety is also discussed. Additional technical and safety policies relate to pediatric, unconscious, incapacitated, or pregnant patients and pregnant imaging personnel. Division of the MR imaging environment into four distinct, clearly labeled zones--with progressive restriction of entry and increased supervision for higher zones--is a mandatory and key aspect in avoidance of MR imaging-related accidents. All MR imaging facilities should have a documented plan to handle emergencies within zone IV, including cardiac arrest or code, magnet quench, and fires. Policies from the authors' own practice are provided for additional reference. Online supplemental material is available for this article.


Assuntos
Imageamento por Ressonância Magnética/métodos , Segurança do Paciente , Radiologia/métodos , Contraindicações , Meios de Contraste/efeitos adversos , Aprovação de Equipamentos/normas , Feminino , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/normas , Masculino , Saúde Ocupacional/normas , Guias de Prática Clínica como Assunto , Gravidez , Próteses e Implantes , Gestão de Riscos
9.
Abdom Imaging ; 40(6): 1645-54, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26109511

RESUMO

Diffusion-weighted imaging (DWI) has become an increasingly used tool in abdominal and pelvic magnetic resonance imaging (MRI), primarily in the oncologic setting. DWI sequences are being added to routine MRI protocols at many institutions, and as its use has spread, more non-oncologic applications have been explored. The purpose of this article is to provide a review of DWI applications in inflammatory, infectious, autoimmune-mediated, and ischemic processes affecting the genitourinary system.


Assuntos
Imagem de Difusão por Ressonância Magnética , Doenças Urogenitais Femininas/patologia , Doenças Urogenitais Masculinas/patologia , Sistema Urogenital/patologia , Feminino , Humanos , Masculino
10.
J Hum Evol ; 64(4): 280-8, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23453438

RESUMO

Lithic artifacts from the African Middle Stone Age (MSA) offer an avenue to explore a range of human behaviors, including mobility, raw material acquisition, trade and exchange. However, to date, in southern Africa it has not been possible to provenance the locations from which commonly used stone materials were acquired prior to transport to archaeological sites. Here we present results of the first investigation to geochemically fingerprint silcrete, a material widely used for tool manufacture across the subcontinent. The study focuses on the provenancing of silcrete artifacts from the MSA of White Paintings Shelter (WPS), Tsodilo Hills, in the Kalahari Desert of northwest Botswana. Our results suggest that: (i) despite having access to local quartz and quartzite at Tsodilo Hills, MSA peoples chose to transport silcrete over 220 km to WPS from sites south of the Okavango Delta; (ii) these sites were preferred to silcrete sources much closer to Tsodilo Hills; (iii) the same source areas were repeatedly used for silcrete supply throughout the 3 m MSA sequence; (iv) during periods of colder, wetter climate, silcrete may have been sourced from unknown, more distant, sites. Our results offer a new provenancing approach for exploring prehistoric behavior at other sites where silcrete is present in the archaeological record.


Assuntos
Arqueologia , Sedimentos Geológicos/análise , Meios de Transporte , Botsuana , Humanos , Tecnologia
11.
Lymphat Res Biol ; 21(2): 111-117, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35914097

RESUMO

Background: Secondary upper extremity lymphedema occurs after an insult such as surgery. One theory suggests underlying lymphatic dysfunction predisposing certain patients into developing secondary lymphedema. We aim to determine the rate of incidental edema in the contralateral upper extremity of patients with secondary unilateral lymphedema. Methods and Results: MRI of the upper extremities were obtained in patients with lymphedema who were referred by a lymphedema clinic from 2017 to 2019. Axial short-tau inversion recovery MR images of the symptomatic and contralateral arms were retrospectively reviewed and edema severity was graded. Interobserver agreement was calculated. Indocyanine green (ICG) lymphography was compared against MRI stage in symptomatic and contralateral. Age, symptom duration, body mass index (BMI), and history of chemotherapy were compared between patients with and without contralateral limb lymphedema. ICG severity was compared against MRI stage. Seventy-eight patients were analyzed. The MRI stages of symptomatic versus contralateral arms were 1.7 ± 1.1 versus 0.1 ± 0.4 (p < 0.00001). Interobserver agreement was 0.86 (0.79-0.94). Of the patients with MRI Stage 1 or above in the symptomatic arm (n = 64), 55 (82.1%) patients demonstrated no abnormality in the contralateral arm. Nine patients (14.1%) demonstrated asymptomatic edema (MRI Stage 1). The mean ICG lymphography stage of symptomatic versus contralateral arms was 1.83 ± 0.96 versus 0.04 ± 0.25 (p < 0.00001). There was no difference in the age, symptom duration, BMI, or history of chemotherapy between patients with or without edema in the contralateral arm. Conclusion: Asymptomatic contralateral edema was detected in 14.1% of patients with unilateral secondary upper extremity lymphedema using MRI modality.


Assuntos
Doenças Assintomáticas , Linfedema Relacionado a Câncer de Mama , Complicações Pós-Operatórias , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/epidemiologia , Braço , Imageamento por Ressonância Magnética , Gravidade do Paciente , Verde de Indocianina , Linfografia , Doenças Assintomáticas/epidemiologia , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Linfedema Relacionado a Câncer de Mama/diagnóstico por imagem , Linfedema Relacionado a Câncer de Mama/epidemiologia
12.
J Magn Reson Imaging ; 35(5): 1216-21, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22247050

RESUMO

PURPOSE: To develop a robust T(2) -weighted volumetric imaging technique with uniform water-silicone separation and simultaneous fat suppression for rapid assessment of breast implants in a single acquisition. MATERIALS AND METHODS: A three-dimensional (3D) fast spin echo sequence that uses variable refocusing flip angles was combined with a three-point chemical-shift technique (IDEAL) and short tau inversion recovery (STIR). Phase shifts of -π/6, +π/2, and +7π/6 between water and silicone were used for IDEAL processing. For comparison, two-dimensional images using 2D-FSE-IDEAL with STIR were also acquired in axial, coronal, and sagittal orientations. RESULTS: Near-isotropic (true spatial resolution-0.9 × 1.3 × 2.0 mm(3) ) volumetric breast images with uniform water-silicone separation and simultaneous fat suppression were acquired successfully in clinically feasible scan times (7:00-10:00 min). The 2D images were acquired with the same in-plane resolution (0.9 × 1.3 mm(2) ), but the slice thickness was increased to 6 mm with a slice gap of 1 mm for complete coverage of the implants in a reasonable scan time, which varied between 18:00 and 22:30 min. CONCLUSION: The single volumetric acquisition with uniform water and silicone separation enables images to be reformatted into any orientation. This allows comprehensive assessment of breast implant integrity in less than 10 min of total examination time.


Assuntos
Implantes de Mama , Mama/anatomia & histologia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Tecido Adiposo/anatomia & histologia , Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Géis de Silicone , Água
13.
Eur Radiol ; 22(10): 2201-10, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22661019

RESUMO

OBJECTIVES: To assess the value of dynamic contrast-enhanced (DCE) combined with T2-weighted (T2W) endorectal coil (ERC) magnetic resonance imaging (MRI) at 3 T for determining extracapsular extension (ECE) of prostate cancer. METHODS: In this IRB-approved study, ERC 3-T MRI of the prostate was performed in 108 patients before radical prostatectomy. T2W fast spin-echo and DCE 3D gradient echo images were acquired. The interpretations of readers with varied experience were analysed. MRI-based staging results were compared with radical prostatectomy histology. Descriptive statistics were generated for prediction of ECE and staging accuracies were determined by the area under the receiver-operating characteristic curve. RESULTS: The overall sensitivity, specificity, positive predictive value and negative predictive value for ECE were 75 %, 92 %, 79 % and 91 %, respectively. Diagnostic accuracy for staging was 86 %, 80 % and 91 % for all readers, experienced and less experienced readers, respectively. CONCLUSIONS: ERC 3-T MRI of the prostate combining DCE and T2W imaging is an accurate pretherapeutic staging tool for assessment of ECE in clinical practice across varying levels of reader experience. KEY POINTS : • Endorectal coil (ERC) magnetic resonance imaging is widely used for imaging prostatic disease. • ERC 3-T MRI is reasonably accurate for local prostate cancer staging. • High diagnostic accuracy is achievable across different levels of reader experience. • MRI facilitates therapeutic decisions in patients with prostate cancer.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/patologia , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Valor Preditivo dos Testes , Estudos Prospectivos
14.
Clin Imaging ; 80: 400-405, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34534773

RESUMO

PURPOSE: The purpose of the study is to determine if a combination of dermal thickening and subcutaneous fluid honeycombing on non-contrast MRI, termed the dermal rim sign (DRS), can be diagnostically analogous to dermal backflow seen on lymphoscintigraphy in patients with secondary upper extremity lymphedema. MATERIALS AND METHODS: Upper extremity MRI and lymphoscintigraphy were performed on patients referred to a multidisciplinary lymphedema clinic for suspicion of secondary lymphedema. Sensitivity, specificity, and positive and negative predictive values of DRS on MRI in detecting dermal backflow on lymphoscintigraphy and the correlation between DRS, Indocyanine Green (ICG) lymphography, bioimpedence L-Dex® ratio and MRI Lymphedema Staging were calculated. Weighted interobserver agreements on the presence and location of DRS on MRI were calculated. RESULTS: Of the 45 patients in the study, 91.1% (41/45) of patients had history of breast cancer. The average age was 58.4 ± 10.5 years, with a mean symptom duration of 4.7 ± 4.4 years. The mean BMI was 30.5 ± 7.0 kg/m2. Interobserver agreement on the presence and the extent of DRS on MRI was 0.93 [95% confidence-interval: 0.80-1]. DRS was present in 97% (32/33) of patients who demonstrated dermal backflow on lymphoscintigraphy. Sensitivity, specificity, PPV, and NPV of DRS were 96.6% [81.7%-99.9%], and 75.0% [47.6%-92.7%], 87.5% [74.9%-94.3%], and 92.3% [63.1%-98.8%]. DRS was associated with severity on ICG lymphography and bioimpedance (both p < 0.001). CONCLUSIONS: DRS on non-contrast MRI is highly predictive of dermal backflow and correlates with clinical measures of lymphedema severity. DRS may be used as an independent diagnostic biomarker to identify patients who would benefit from dedicated exams.


Assuntos
Linfedema , Idoso , Humanos , Linfedema/diagnóstico por imagem , Linfedema/etiologia , Linfografia , Linfocintigrafia , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Extremidade Superior
15.
J Magn Reson Imaging ; 32(3): 745-51, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20815077

RESUMO

PURPOSE: To develop a robust 3D fast spin echo (FSE) T(2)-weighted imaging method with uniform water and fat separation in a single acquisition, amenable to high-quality multiplanar reformations. MATERIALS AND METHODS: The Iterative Decomposition of water and fat with Echo Asymmetry and Least squares estimation (IDEAL) method was integrated with modulated refocusing flip angle 3D-FSE. Echoes required for IDEAL processing were acquired by shifting the readout gradient with respect to the Carr-Purcell-Meiboom-Gill echo. To reduce the scan time, an alternative data acquisition using two gradient echoes per repetition was implemented. Using the latter approach, a total of four gradient echoes were acquired in two repetitions and used in the modified IDEAL reconstruction. RESULTS: 3D-FSE T(2)-weighted images with uniform water-fat separation were successfully acquired in various anatomies including breast, abdomen, knee, and ankle in clinically feasible scan times, ranging from 5:30-8:30 minutes. Using water-only and fat-only images, in-phase and out-of-phase images were reconstructed. CONCLUSION: 3D-FSE-IDEAL provides volumetric T(2)-weighted images with uniform water and fat separation in a single acquisition. High-resolution images with multiple contrasts can be reformatted to any orientation from a single acquisition. This could potentially replace 2D-FSE acquisitions with and without fat suppression and in multiple planes, thus improving overall imaging efficiency.


Assuntos
Tecido Adiposo , Água Corporal , Imagem Ecoplanar/métodos , Imageamento Tridimensional/métodos , Imagens de Fantasmas , Abdome/anatomia & histologia , Articulação do Tornozelo/anatomia & histologia , Mama/anatomia & histologia , Feminino , Humanos , Articulação do Joelho/anatomia & histologia , Masculino , Relação Quantitativa Estrutura-Atividade , Valores de Referência , Marcadores de Spin
16.
Nat Commun ; 11(1): 4386, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32873784

RESUMO

Global resources of heavy Rare Earth Elements (REE) are dominantly sourced from Chinese regolith-hosted ion-adsorption deposits in which the REE are inferred to be weakly adsorbed onto clay minerals. Similar deposits elsewhere might provide alternative supply for these high-tech metals, but the adsorption mechanisms remain unclear and the adsorbed state of REE to clays has never been demonstrated in situ. This study compares the mineralogy and speciation of REE in economic weathering profiles from China to prospective regoliths developed on peralkaline rocks from Madagascar. We use synchrotron X-ray absorption spectroscopy to study the distribution and local bonding environment of Y and Nd, as proxies for heavy and light REE, in the deposits. Our results show that REE are truly adsorbed as easily leachable 8- to 9-coordinated outer-sphere hydrated complexes, dominantly onto kaolinite. Hence, at the atomic level, the Malagasy clays are genuine mineralogical analogues to those currently exploited in China.

17.
BMJ Case Rep ; 12(12)2019 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-31843780

RESUMO

Acute gastrointestinal (GI) immune-related adverse events (irAE) are commonly reported by patients with cancer undergoing treatment with immune checkpoint inhibitors (CPI); however chronic irAEs are rare. We present a case of a 71-year-old woman with metastatic gastro-oesophageal junction (GOJ) adenocarcinoma who developed delayed-onset chronic intestinal pseudo-obstruction (CIPO) while receiving second-line pembrolizumab. Repeated CT scans of the abdomen/pelvis found no small bowel obstruction, and evaluations for bowel inflammation, infection and paraneoplastic syndrome were negative. Bowel rest and glucocorticoids were associated with transient symptom resolution; however, symptoms recurred within 1 month. The patient was ultimately supported with total parenteral nutrition and intestinal motility agents. After 4 months, the GOJ cancer remained stable with no signs of progression. As CPI use expands, the incidence of rare irAEs, such as CIPO, may increase.


Assuntos
Adenocarcinoma/tratamento farmacológico , Anticorpos Monoclonais Humanizados/efeitos adversos , Antineoplásicos Imunológicos/efeitos adversos , Neoplasias Esofágicas/tratamento farmacológico , Pseudo-Obstrução Intestinal/induzido quimicamente , Adenocarcinoma/diagnóstico por imagem , Idoso , Anticorpos Monoclonais Humanizados/administração & dosagem , Antineoplásicos Imunológicos/administração & dosagem , Neoplasias Esofágicas/diagnóstico por imagem , Junção Esofagogástrica , Feminino , Humanos , Pseudo-Obstrução Intestinal/diagnóstico por imagem , Metástase Linfática/diagnóstico por imagem , Metástase Linfática/tratamento farmacológico , Ultrassonografia
18.
J Am Coll Radiol ; 16(11S): S384-S391, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31685106

RESUMO

Palpable abdominal masses may arise from the abdominal cavity or the abdominal wall. The differential diagnosis is broad for each variant ranging from benign lipomas, inflammatory processes, to malignant tumors. The imaging approach to diagnosis varies by location. For intra-abdominal masses, contrast-enhanced CT and ultrasound examination have demonstrated accuracy. For abdominal wall masses, which may arise from muscle, subcutaneous tissue, or connective tissue, MRI, CT, and ultrasound all provide diagnostic value. This publication reviews the current evidence supporting the imaging approach to diagnosis of palpable abdominal masses for two variants: suspected intra-abdominal neoplasm and suspected abdominal wall masses. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.


Assuntos
Cavidade Abdominal/diagnóstico por imagem , Neoplasias Abdominais/diagnóstico por imagem , Neoplasias Abdominais/patologia , Diagnóstico por Imagem/métodos , Guias de Prática Clínica como Assunto , Cavidade Abdominal/patologia , Meios de Contraste , Medicina Baseada em Evidências , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Controle de Qualidade , Sensibilidade e Especificidade , Sociedades Médicas/normas , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia Doppler/métodos , Estados Unidos
19.
J Am Coll Radiol ; 16(5S): S104-S115, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31054737

RESUMO

This review summarizes the relevant literature for the initial imaging of patients with symptoms of dysphagia. For patients with oropharyngeal dysphagia who have an underlying attributable cause, a modified barium swallow is usually appropriate for initial imaging but for those who have unexplained dysphagia a fluoroscopic biphasic esophagram is usually appropriate. Fluoroscopic biphasic esophagram is usually appropriate for initial imaging in both immunocompetent and immunocompromised patients who have retrosternal dysphagia. For postoperative patients with dysphagia, fluoroscopic single-contrast esophagram and CT neck and chest with intravenous (IV) contrast are usually appropriate for oropharyngeal or retrosternal dysphagia occurring in the early postoperative period where water-soluble contrast is usually preferred rather than barium sulfate. In the later postoperative period (greater than 1 month), CT neck and chest with IV contrast and fluoroscopic single-contrast esophagram are usually appropriate. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.


Assuntos
Transtornos de Deglutição/diagnóstico por imagem , Meios de Contraste , Diagnóstico Diferencial , Medicina Baseada em Evidências , Humanos , Sociedades Médicas , Estados Unidos
20.
J Am Coll Radiol ; 16(5S): S141-S149, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31054740

RESUMO

This review summarizes the relevant literature regarding imaging of suspected diverticulitis as an etiology for left lower quadrant pain, and imaging of complications of acute diverticulitis. The most common cause of left lower quadrant pain in adults is acute sigmoid or descending colonic diverticulitis. Appropriate imaging triage for patients with suspected diverticulitis should address the differential diagnostic possibilities and what information is necessary to make a definitive management decision. Patients with diverticulitis may require surgery or interventional radiology procedures because of associated complications, including abscesses, fistulas, obstruction, or perforation. As a result, there has been a trend toward greater use of imaging to confirm the diagnosis of diverticulitis, evaluate the extent of disease, and detect complications before deciding on appropriate treatment. Additionally, in the era of bundled payments and minimizing health care costs, patients with acute diverticulitis are being managed on an outpatient basis and rapid diagnostic imaging at the time of initial symptoms helps to streamline and triage patients to the appropriate treatment pathway. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.


Assuntos
Dor Abdominal/diagnóstico por imagem , Doença Diverticular do Colo/diagnóstico por imagem , Meios de Contraste , Diagnóstico Diferencial , Medicina Baseada em Evidências , Humanos , Sociedades Médicas , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA