Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
J Cardiovasc Electrophysiol ; 35(6): 1165-1173, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38571287

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) is often performed under general anaesthesia (GA) or deep sedation. Anaesthetic availability is limited in many centers, and deep sedation is prohibited in some countries without anaesthetic support. Very high-power short duration (vHPSD-90W/4 s) PVI using the Q-Dot catheter is generally well tolerated under mild conscious sedation (MCS) though an understanding of catheter stability and long-term effectiveness is lacking. We analyzed lesion metrics and 12-month freedom from atrial arrythmia with this approach. METHODS: Our approach to radiofrequency (RF) PVI under MCS is standardized and includes a single catheter approach with a steerable sheath. We identified patients undergoing Q-Dot RF PVI between March 2021 and December 2022 in our center, comparing those undergoing vHPSD ablation under MCS (90W/MCS) against those undergoing 50 W ablation under GA (50 W/GA) up to 12 months of follow-up. Data were extracted from clinical records and the CARTO system. RESULTS: Eighty-three patients met our inclusion criteria (51 90W/MCS; 32 50 W/GA). Despite shorter ablation times (353 vs. 886 s; p < .001), the 90 W/MCS group received more lesions (median 87 vs. 58, p < .001), resulting in similar procedure times (149.3 vs. 149.1 min; p = .981). PVI was achieved in all cases, and first pass isolation rates were similar (left wide antral circumferential ablation [WACA] 82.4% vs. 87.5%, p = .758; right WACA 74.5% vs. 78.1%, p = .796; 90 W/MCS vs. 50 W/GA respectively). Analysis of 6647 ablation lesions found similar mean impedance drops (10.0 ± 1.9 Ω vs. 10.0 ± 2.2 Ω; p = .989) and mean contact force (14.6 ± 2.0 g vs. 15.1 ± 1.6 g; p = .248). Only median 2.5% of lesions in the 90 W/MCS cohort failed to achieve ≥ 5 Ω drop. In the 90 W/MCS group, there were no procedural related complications, and 12-month freedom from atrial arrhythmia was observed in 78.4%. CONCLUSION: vHPSD PVI is feasible under MCS, with encouraging acute and long-term procedural outcomes. This provides a compelling option for centers with limited anaesthetic support.


Assuntos
Potenciais de Ação , Fibrilação Atrial , Ablação por Cateter , Sedação Consciente , Frequência Cardíaca , Veias Pulmonares , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fatores de Tempo , Idoso , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Estudos Retrospectivos , Recidiva , Resultado do Tratamento , Cateteres Cardíacos , Intervalo Livre de Progressão , Fatores de Risco
2.
J Vasc Res ; 61(2): 59-67, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38447552

RESUMO

INTRODUCTION: Atrial fibrillation (AF) is associated with endothelial damage/dysfunction. Herein, we tested the hypothesis that brachial artery flow-mediated dilation (FMD) is superior in AF patients taking apixaban compared to warfarin. METHODS: AF patients on apixaban (n = 46; 67 [7] years; mean [standard deviation]; 15 women) and warfarin (n = 27; 73 [9] years (p < 0.01); 11 women) were recruited. Duplex Doppler ultrasound imaging was undertaken during baseline (2 min), cuff inflation (5 min), and following cuff deflation (3 min). FMD was defined as peak increase in brachial artery diameter following cuff deflation and analysed as percentage change in diameter, as a ratio of FMD, shear rate area under the curve (SRAUC; FMD-to-SRAUC), and using SRAUC as a covariate (FMDSR). RESULTS: Baseline artery diameter (4.96 [1.14] vs. 4.89 [0.88] mm), peak diameter (5.12 [1.17] vs. 5.14 [0.93] mm), and FMDSR (3.89 [3.62] vs. 4.80 [3.60] %) were not different between warfarin and apixaban (p > 0.05; analysis of covariance with age, CHA2DS2-VASc, years since AF diagnosis, number of diabetics, alcohol drinkers, and units of alcohol consumed per week as covariates). Stepwise multiple regression identified independent association of fibrillation, hypertension, and increased age with FMD. CONCLUSION: AF patients on warfarin and apixaban exhibit similar endothelium-dependent vasodilation. Increased blood pressure negatively impacts vasodilator capacity in AF patients.


Assuntos
Fibrilação Atrial , Varfarina , Humanos , Feminino , Pré-Escolar , Varfarina/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Pirazóis/efeitos adversos , Piridonas/efeitos adversos
3.
J Cardiovasc Electrophysiol ; 33(3): 389-400, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34921465

RESUMO

INTRODUCTION: Radiofrequency catheter ablation is a cornerstone of treatment for many cardiac arrhythmias. Progression in three-dimensional mapping and contact-force sensing technologies have improved our capability to achieve success, but challenges still remain. METHODS: In this article, we discuss the importance of overall circuit impedance in radiofrequency lesion formation. This is followed by a review of the literature regarding recently developed "local impedance" technology and its current and future potential applications and limitations, in the context of established surrogate markers currently used to infer effective ablation. RESULTS: We discuss the role of local impedance in assessing myocardial substrate, as well as its role in clinical studies of ablation. We also discuss safety considerations, limitations and ongoing research. CONCLUSION: Local impedance is a novel tool which has the potential to tailor ablation in a manner distinct from other established metrics.


Assuntos
Ablação por Cateter , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Impedância Elétrica , Humanos
4.
Indian Pacing Electrophysiol J ; 22(4): 200-206, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35642824

RESUMO

BACKGROUND: Ablation index (AI)-guided ablation for posterior wall isolation (PWI) using high-power, short-duration remains untested. We sought to evaluate the acute outcomes of AI-guided 50 W ablation vs. conventional ablation, and investigate the differences in relationship between contact force (CF), time and AI in both groups. METHODS: Consecutive patients undergoing first-time AI-guided ablation with PWI using either 50 W or 35-40 W ablation were enrolled. Acute procedural metrics and individual lesion level ablation data were compared between groups. RESULTS: 40 patients (50 W: n = 20, 35-40 W: n = 20) with atrial fibrillation were included. Total procedure time was significantly reduced with 50 W (120 vs. 143 mins, p = 0.004) and there was a trend toward decreased ablation time (22 vs. 28 mins, p = 0.052). First pass and acute success of PWI were comparable between the 50 W and 35-40 W groups (10 vs. 8 patients, p = 0.525 and 20 vs. 19 patients, p = 1.000, respectively). Individual lesion analysis of all 959 RF applications (50 W: n = 458, 35-40 W: n = 501) demonstrated that 50 W ablation led to lower ablation time per lesion (10.4 vs. 13.0s, p < 0.001), and increased AI (471 vs. 461, p < 0.001) and impedance drop (7.4 vs. 6.9ohms, p = 0.007). Excessive ablations (AI>600 for roof line; AI>500 elsewhere) were more frequently observed in the 50 W group (9.0% vs. 4.6%, p = 0.007). CF had very good discriminative capability for excessive ablation in both groups. At 50 W, limiting the CF to <10 g reduced the number of excessive ablations on the floor line and within the posterior box to 12% and 4%,respectively. Recurrence of atrial arrhythmias at 12 months were comparable between the groups. CONCLUSION: AI-guided 50 W RF ablation reduces the ablation time of individual lesions and total procedure time without compromising first pass and acute success rates of PWI or 12-month outcomes compared to conventional powers.

5.
Europace ; 23(6): 878-886, 2021 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-33693677

RESUMO

AIMS: The safety of Ablation Index (AI)-guided 50 W ablation for atrial fibrillation (AF) remains uncertain, and mid-term clinical outcomes have not been described. The interplay between AI and its components at 50 W has not been reported. METHODS AND RESULTS: Eighty-eight consecutive AF patients (44% paroxysmal) underwent AI-guided 50 W ablation. Procedural and 12-month clinical outcomes were compared with 93 consecutive controls (65% paroxysmal) who underwent AI-guided ablation using 35-40 W. Posterior wall isolation (PWI) was performed in 44 (50%) and 23 (25%) patients in the 50 and 35-40 W groups, respectively, P < 0.001. The last 10 patients from each group underwent analysis of individual lesions (n = 1230) to explore relationships between different powers and the AI components. Pulmonary vein isolation was successful in all patients. Posterior wall isolation was successful in 41/44 (93.2%) and 22/23 (95.7%) in the 50 and 35-40 W groups, respectively (P = 0.685). Radiofrequency times (20 vs. 26 min, P < 0.001) and total procedure times (130 vs. 156 min, P = 0.002) were significantly lower in the 50 W group. No complication or steam pop was seen in either group. Twelve-month freedom from arrhythmia was similar (80.2% vs. 82.8%, P = 0.918). A higher proportion of lesions in the 50 W group were associated with impedance drop >7 Ω (54.6% vs. 45.5%, P < 0.001). Excessive ablation (AI >600 anteriorly, >500 posteriorly) was more frequent in the 50 W group (9.7% vs. 4.3%, P < 0.001). CONCLUSION: Ablation Index-guided 50 W AF ablation is as safe and effective as lower powers and results in reduced ablation and procedure times. Radiofrequency lesions are more likely to be therapeutic, but there is a higher risk of delivering excessive ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Benchmarking , Ablação por Cateter/efeitos adversos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 30(1): 118-127, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30203441

RESUMO

BACKGROUND: A large number of SCN5A variants have been reported to underlie Brugada syndrome (BrS). However, the evidence supporting individual variants is highly heterogeneous. OBJECTIVE: We systematically re-evaluated all SCN5A variants reported in BrS using the 2015 American college of medical genetics and genomics and the association for molecular pathology (ACMG-AMP) guidelines. METHODS: A PubMed/Embase search was performed to identify all reported SCN5A variants in BrS. Standardized bioinformatic re-analysis (SIFT, PolyPhen, Mutation Taster, Mutation assessor, FATHMM, GERP, PhyloP, and SiPhy) and re-evaluation of frequency in the gnomAD database were performed. Fourteen ACMG-AMP rules were deemed applicable for SCN5A variant analysis. RESULTS: Four hundred and eighty unique SCN5A variants were identified, the majority of which 425 (88%) were coding variants. One hundred and fifty-six of 425 (37%) variants were classified as pathogenic/likely pathogenic. Two hundred and fifty-eight (60%) were classified as variants of uncertain significance, while a further 11 (3%) were classified as benign/likely benign. When considering the subset of variants that were considered "null" variants separately, 95% fulfilled criteria for pathogenicity/likely pathogenicity. In contrast, only 17% of missense variants fulfilled criteria for pathogenicity/likely pathogenicity. Importantly, however, only 25% of missense variants had available functional data, which was a major score driver for pathogenic classification. CONCLUSION: Based on contemporary ACMG-AMP guidelines, only a minority of SCN5A variants implicated in BrS fulfill the criteria for pathogenicity or likely pathogenicity.


Assuntos
Síndrome de Brugada/genética , Variação Genética , Canal de Sódio Disparado por Voltagem NAV1.5/genética , Potenciais de Ação , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/metabolismo , Síndrome de Brugada/fisiopatologia , Predisposição Genética para Doença , Frequência Cardíaca , Humanos , Canal de Sódio Disparado por Voltagem NAV1.5/metabolismo , Fenótipo , Fatores de Risco
7.
Europace ; 21(5): 738-745, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30753411

RESUMO

AIMS: Video-assisted thoracoscopic surgery (VATS) ablation has been advocated as a treatment option for non-paroxysmal atrial fibrillation (AF) in recent guidelines. Real-life data on its safety and efficacy during a centre's early experience are sparse. METHODS AND RESULTS: Thirty patients (28 persistent/longstanding persistent AF) underwent standalone VATS ablation for AF by an experienced thoracoscopic surgeon, with the first 20 cases proctored by external surgeons. Procedural and follow-up outcomes were collected prospectively, and compared with 90 propensity-matched patients undergoing contemporaneous catheter ablation (CA). Six (20.0%) patients undergoing VATS ablation experienced ≥1 major complication (death n = 1, stroke n = 2, conversion to sternotomy n = 3, and phrenic nerve injury n = 2). This was significantly higher than the 1.1% major complication rate (tamponade requiring drainage n = 1) seen with CA (P < 0.001). Twelve-month single procedure arrhythmia-free survival rates without antiarrhythmic drugs were 56% in the VATS and 57% in the CA cohorts (P = 0.22), and 78% and 80%, respectively given an additional CA and antiarrhythmic drugs (P = 0.32). CONCLUSION: During a centre's early experience, VATS ablation may have similar success rates to those from an established CA service, but carry a greater risk of major complications. Those embarking on a programme of VATS AF ablation should be aware that complication and success rates may differ from those reported by selected high-volume centres.


Assuntos
Fibrilação Atrial/cirurgia , Tamponamento Cardíaco , Ablação por Cateter , Conversão para Cirurgia Aberta/estatística & dados numéricos , Complicações Intraoperatórias , Cirurgia Torácica Vídeoassistida , Fibrilação Atrial/diagnóstico , Tamponamento Cardíaco/epidemiologia , Tamponamento Cardíaco/etiologia , Tamponamento Cardíaco/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Estudos de Coortes , Pesquisa Comparativa da Efetividade , Feminino , Humanos , Complicações Intraoperatórias/epidemiologia , Complicações Intraoperatórias/etiologia , Masculino , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde , Nervo Frênico/lesões , Cirurgia Torácica Vídeoassistida/efeitos adversos , Cirurgia Torácica Vídeoassistida/métodos , Reino Unido
8.
Pacing Clin Electrophysiol ; 42(11): 1448-1455, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31538362

RESUMO

BACKGROUND: Atrial fibrillation (AF) ablation is a complex procedure, generally requiring at least one overnight hospital stay. We investigated the safety and feasibility of early mobilization and same-day discharge following streamlined peri-ablation management for AF. METHODS: From 2014, we offered same-day discharge to selected patients who underwent uncomplicated AF ablation on the morning lists, with ultrasound-guided femoral access, uninterrupted warfarin or minimal interruption in novel oral anticoagulants, and reversal of intraprocedural heparin with protamine. Patients were discharged 6-8 h postprocedure and offered access to a dedicated nurse helpline. RESULTS: Of 1599 AF ablation cases performed from April 2014 to March 2017, 811 (50.7%) were performed on the morning lists and 169/811 (20.8%) were discharged on the same day. Excluding 26 research cases, 1/143 (0.7%) had transient right phrenic nerve palsy and five (3.5%) cases experienced minor problems that did not preclude same-day discharge; three (2.1%) needed rehospitalization postdischarge: one for pericarditic chest pain and two for nausea/vomiting. Compared to 642 overnight cases, day-case procedures were shorter, more likely to be redos, to be performed under sedation rather than general anesthesia, and less likely to involve linear lesions and electrical cardioversion. There were no significant differences in patient age, gender, body mass index, CHA2 DS2 -VASc, in preprocedural anticoagulation regimen (warfarin vs novel anticoagulants vs no anticoagulation) and in choice of ablation method (cryoballoon vs radiofrequency). CONCLUSIONS: Selective same-day discharge after AF ablation is safe and feasible using a streamlined peri-procedural care protocol. Wider adoption can potentially reduce health-care costs while improving patient experience.


Assuntos
Procedimentos Cirúrgicos Ambulatórios , Fibrilação Atrial/cirurgia , Ablação por Cateter , Alta do Paciente , Seleção de Pacientes , Idoso , Ablação por Cateter/efeitos adversos , Deambulação Precoce , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fatores de Tempo
9.
J Cardiovasc Electrophysiol ; 29(11): 1493-1499, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30230085

RESUMO

INTRODUCTION: Demonstration of exit block after pulmonary vein isolation (PVI) is the cornerstone of ablation for atrial fibrillation (AF). It requires the demonstration of local pulmonary vein (PV) capture and absence of conduction to the atrium but is often challenging due to the inability to see local paced PV-evoked potentials. We retrospectively examined the ability of adenosine to augment this technique during CARTO-based radiofrequency ablation procedures. METHODS: Retrospective analysis of evoked PV potentials during adenosine administration while testing for PV exit block at a single UK center. RESULTS: One hundred and twenty-nine PVs in 33 patients were isolated using radiofrequency energy to demonstrate entry block. Of those, the pacing of 24 veins under baseline conditions did not clearly demonstrate local PV-evoked potentials sufficient to be sure that the local vein was truly captured and dissociated from the atrium. Adenosine was administered in 19 of these, with 10 of 19 (52.6%) veins then demonstrating clear local PV-evoked potentials transiently during adenosine administration, sufficient to allow assessment of definite exit block. CONCLUSION: Adenosine administered during PV pacing allows transient visualization of local PV-evoked potentials after PVI facilitating the clearer demonstration of PV exit block in over 50% veins.


Assuntos
Adenosina/administração & dosagem , Antiarrítmicos/administração & dosagem , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/efeitos dos fármacos , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Humanos , Estudos Retrospectivos
10.
J Cardiovasc Electrophysiol ; 29(6): 881-888, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29505684

RESUMO

INTRODUCTION: The ConfiDENSE™ module (Carto3 v4) allows rapid annotation of endocardial electrograms acquired by multielectrode (ME) mapping. However, its accuracy in assessing atrial voltages is unknown. METHODS AND RESULTS: Two ConfiDENSE™ left atrial voltage maps were created during continuous pacing in 20 patients undergoing catheter ablation for persistent AF using a ME lasso catheter and a contact force (CF) sensing ablation catheter. The automated tissue proximity indicator (TPI) filter was then applied to the ME map to yield a TPI map. Reference maps (RM) were created offline by a blinded observer by manually assessing all points against fidelity criteria. Bipolar voltages and proportion of low voltage points (< 0.5 mV) derived from the ME, CF, and TPI maps were compared with those derived from the RM. Note that 853 ± 365 points, 252 ± 184 points, and 144 ± 73 were collected for ME, TPI, and CF maps, respectively, and 429 ± 153 points were included in the RM. Voltages with CF and TPI maps were similar to those with RM (1.57 ± 0.47 mV vs. 1.63 ± 0.31 mV, P = 0.57 and 1.50 ± 0.38 mV vs. 1.63 ± 0.31 mV, P = 0.07, respectively), whereas ME maps showed a significantly lower mean voltage (1.00 ± 0.22 mV, P < 0.001). As compared to RM maps (17 ± 8%), low voltage points were significantly overestimated by the ME maps (50 ± 9% (P < 0.001) and TPI maps (28 ± 13% (P < 0.001), but not by the CF maps (22 ± 14%, P = 0.17). CONCLUSION: Application of the TPI filter to ConfiDENSE maps significantly increases the quality of the voltage data, conserving a reasonable point density, but still overestimates low voltage points as compared to CF-sensing maps or maps reviewed manually.


Assuntos
Potenciais de Ação , Fibrilação Atrial/diagnóstico , Função do Átrio Esquerdo , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Veias Pulmonares/fisiopatologia , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Estimulação Cardíaca Artificial , Ablação por Cateter , Eletrodos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Veias Pulmonares/cirurgia , Reprodutibilidade dos Testes , Fatores de Tempo
11.
J Cardiovasc Electrophysiol ; 28(9): 1037-1047, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28639728

RESUMO

AIMS: Late recovery of ablated tissue leading to reconnection of pulmonary veins remains common following radiofrequency catheter ablation for AF. Ablation Index (AI), a novel ablation quality marker, incorporates contact force (CF), time, and power in a weighted formula. We hypothesized that prospective use of our previously published derived AI targets would result in better outcomes when compared to CF-guided ablation. METHODS: Eighty-nine consecutive drug-refractory AF patients (49% paroxysmal) underwent AI-guided ablation (AI-group). AI targets were 550 for anterior/roof and 400 for posterior/inferior left atrial segments. Procedural and clinical outcomes of these patients were compared to 89 propensity-matched controls who underwent CF-guided ablation (CF-group). All 178 procedures were otherwise similar, and both groups were followed-up for 12 months. The last 25 patients from each group underwent analysis of all VisiTags™ for ablation duration, CF, Force-Time Integral, and impedance drop. RESULTS: First-pass pulmonary vein isolation (PVI) was more frequent in AI-group than in CF-group (173 [97%] vs. 149 [84%] circles, P < 0.001), and acute PV reconnection was lower (11 [6%] vs. 24 [13%] circles, P = 0.02). Mean PVI ablation time was similar (AI-group: 42 ± 9 vs. CF-group: 45 ± 14 minutes, P = 0.14). Median impedance drop for AI-group was significantly higher than in CF-group (13.7 [9-19] Ω vs. 8.8 [5.2-13] Ω, P < 0.001). Two major complications occurred in CF-group and none in AI-group. Atrial tachyarrhythmia recurrence was significantly lower in AI-group (15 of 89 [17%]) than in CF-group (33 of 89 [37%], P = 0.002). CONCLUSION: AI-guided ablation is associated with significant improvements in the incidence of acute PV reconnection and atrial tachyarrhythmia recurrence rate compared to CF-guided ablation, potentially due to creation of better quality lesions as suggested by greater impedance drop.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Prospectivos , Curva ROC , Resultado do Tratamento
12.
Europace ; 19(5): 775-783, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-27247002

RESUMO

AIMS: Force-Time Integral (FTI) is commonly used as a marker of ablation lesion quality during pulmonary vein isolation (PVI), but does not incorporate power. Ablation Index (AI) is a novel lesion quality marker that utilizes contact force, time, and power in a weighted formula. Furthermore, only a single FTI target value has been suggested despite regional variation in left atrial wall thickness. We aimed to study AI's and FTI's relationships with PV reconnection at repeat electrophysiology study, and regional threshold values that predicted no reconnection. METHODS AND RESULTS: Forty paroxysmal atrial fibrillation patients underwent contact force-guided PVI, and the minimum and mean AI and FTI values for each segment were identified according to a 12-segment model. All patients underwent repeat electrophysiology study at 2 months, regardless of symptoms, to identify sites of PV reconnection. Late PV reconnection was seen in 53 (11%) segments in 25 (62%) patients. Reconnected segments had significantly lower minimum AI [308 (252-336) vs. 373 (323-423), P < 0.0001] and FTI [137 (92-182) vs. 228 (157-334), P < 0.0001] compared with non-reconnected segments. Minimum AI and FTI were both independently predictive, but AI had a smaller P value. Higher minimum AI and FTI values were required to avoid reconnection in anterior/roof segments than for posterior/inferior segments (P < 0.0001). No reconnection was seen where the minimum AI value was ≥370 for posterior/inferior segments and ≥480 for anterior/roof segments. CONCLUSION: The minimum AI value in a PVI segment is independently predictive of reconnection of that segment at repeat electrophysiology study. Higher AI and FTI values are required for anterior/roof segments than for posterior/inferior segments to prevent reconnection.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Diagnóstico por Computador/métodos , Sistema de Condução Cardíaco/cirurgia , Avaliação de Resultados em Cuidados de Saúde/métodos , Veias Pulmonares/cirurgia , Fibrilação Atrial/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
13.
J Cardiovasc Electrophysiol ; 27(4): 381-9, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26786052

RESUMO

INTRODUCTION: Acute reconnection of pulmonary veins (PVs) is frequently seen in the waiting period following pulmonary vein isolation (PVI). There are concerns that reablation at these sites may not be durably effective due to tissue edema caused by the initial ablation. We aimed to prospectively study the relationship between acute and late reconnection. METHODS AND RESULTS: Wide-area circumferential PVI was performed in 40 paroxysmal AF patients. Spontaneous reconnection was assessed after a minimum 20-minute waiting period, with adenosine administered to unmask dormant reconnection. All sites of acute reconnection were ablated to reisolate the PV. All 40 patients then underwent repeat electrophysiology study after 2 months, regardless of symptoms, to identify late reconnection. Sites of acute and late reconnection were compared according to a 12-segment PVI model. Acute reconnection was seen in 28 (6%) PVI segments in 20 (50%) patients, affecting 24/160 (15%) PVs. All were successfully reisolated. At repeat electrophysiology study, 51 (11%) PVI segments were reconnected in 25 (62%) patients, affecting 41 (25%) PVs. The proportion of PVI segments with and without acute reconnection exhibiting late reconnection at repeat study was no different (14% vs. 10%, P = 0.524). There was also no difference in late reconnection between PVI circles or patients with and without acute reconnection. CONCLUSION: Most PVI segments that undergo further ablation for acute reconnection show persistent isolation at repeat electrophysiology study, and the rate of late reconnection for these segments is no different to that for segments that did not acutely reconnect. This implies that effective reablation is delivered at these sites.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Sistema de Condução Cardíaco/fisiopatologia , Veias Pulmonares/cirurgia , Doença Aguda , Fibrilação Atrial/prevenção & controle , Mapeamento Potencial de Superfície Corporal/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Recidiva , Reoperação/métodos , Resultado do Tratamento
14.
J Cardiovasc Electrophysiol ; 26(4): 397-403, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25588685

RESUMO

INTRODUCTION: Inability to predict clinical outcome despite acutely successful pulmonary vein isolation (PVI) remains the Achilles' heel of atrial fibrillation ablation (AFA). Arrhythmia recurrence is frequently due to recovery of radiofrequency (RF) ablation lesions believed to be complete at the original procedure. OBJECTIVES: We hypothesized that a high ratio between post-AFA levels of serum high sensitivity cardiac troponin T (HScTnT), a highly specific marker of acute myocardial injury, and duration of RF application (the ablation effectiveness quotient, AEQ) would indicate effective ablation and correlate with early clinical success. METHODS: We prospectively measured HScTnT levels in 60 patients (42 [70%] male, 22 [37%] with paroxysmal AF [PAF], mean age 62.5 ± 10.6 years) 12-18 hours after AFA and calculated the AEQ for each. Patients were followed-up with ECGs and Holter monitors for recurrence of atrial tachyarrhythmia (AT). RESULTS: Early recurrence of AT within 6 months occurred in 22 (37%). AT recurrence was not significantly related to left atrial size or comorbidities, nor to RF time or HScTnT level. Mean AEQ was significantly lower in those with recurrence than those without (0.35 ± 0.14 ng/L/s vs. 0.45 ± 0.18 ng/L/s), P = 0.02. Subgroup analysis showed this finding was due to patients with PAF in whom early significance was maintained to one year, with an AEQ >0.4 ng/L/s having 75% sensitivity and 90% specificity in predicting freedom from AT. CONCLUSION: A high AEQ correlates well with freedom from AT in patients with PAF in both the short and medium term. If confirmed in further studies, AEQ may become a useful marker of risk of AT post-AFA.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Duração da Cirurgia , Troponina T/sangue , Idoso , Área Sob a Curva , Fibrilação Atrial/sangue , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Biomarcadores/sangue , Eletrocardiografia , Inglaterra , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Recidiva , Fatores de Risco , Método Simples-Cego , Fatores de Tempo , Resultado do Tratamento
15.
J Cardiovasc Electrophysiol ; 25(7): 680-5, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24602050

RESUMO

INTRODUCTION: The most frequent complications of AF ablation (AFA) are related to vascular access, but there is little evidence as to how these can be minimized. METHODS: Consecutive patients undergoing AFA at a high-volume center received either standard care (Group S) or routine ultrasound-guided vascular access (Group U). Vascular complications were assessed before hospital discharge and by means of postal questionnaire 1 month later. Outcome measures were BARC 2+ bleeding complications, postprocedural pain, and prolonged bruising. RESULTS: Patients in Group S (n = 146) and U (n = 163) were well matched at baseline. Follow-up questionnaires were received from 92.6%. Patients in Group U were significantly less likely to have a BARC 2+ bleed, 10.4% versus 19.9% P = 0.02, were less likely to suffer groin pain after discharge (27.1% vs. 42.8%; P = 0.006) and were less likely to experience prolonged local bruising (21.5% vs. 40.4%; P = 0.001). Multivariable logistic regression analysis revealed a significant association of vascular complications with nonultrasound guided access (OR 3.12 95%CI 1.54-5.34; P = 0.003) and increasing age (OR 1.05 95%CI 1.01-1.09; P = 0.02). CONCLUSION: Routine use of ultrasound-guided vascular access for AFA is associated with a significant reduction in bleeding complications, postprocedural pain, and prolonged bruising when compared to standard care.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Cateterismo Periférico/métodos , Ultrassonografia de Intervenção , Fatores Etários , Idoso , Fibrilação Atrial/diagnóstico , Ablação por Cateter/efeitos adversos , Cateterismo Periférico/efeitos adversos , Distribuição de Qui-Quadrado , Competência Clínica , Contusões/etiologia , Contusões/prevenção & controle , Inglaterra , Feminino , Hospitais com Alto Volume de Atendimentos , Humanos , Curva de Aprendizado , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/prevenção & controle , Hemorragia Pós-Operatória/etiologia , Hemorragia Pós-Operatória/prevenção & controle , Estudos Prospectivos , Fatores de Risco , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento
16.
J Interv Card Electrophysiol ; 67(5): 1181-1189, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38261098

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) is the cornerstone of atrial fibrillation (AF) ablation. Despite promising success rates, redo ablation is sometimes required. At redo, PVs may be found to be isolated (silent) or reconnected. We studied patients with silent vs reconnected PVs at redo and analysed associations with adverse outcomes. METHODS: Patients undergoing redo AF ablations between 2013 and 2019 at our institution were included and stratified into silent PVs or reconnected PVs. The primary outcome was a composite of further redo ablation, non-AF ablation, atrioventricular nodal ablation, and death. Secondary outcomes included arrhythmia recurrence. RESULTS: A total of 467 patients were included with mean 4.6 ± 1.7 years follow-up, of whom 48 (10.3%) had silent PVs. The silent PV group had had more often undergone >1 prior ablation (45.8% vs 9.8%; p<0.001), had more persistent AF (62.5% vs 41.1%; p=0.005) and had more non-PV ablation performed both at prior ablation procedures and at the analysed redo ablation. The primary outcome occurred more frequently in those with silent PVs (25% vs 13.8%; p=0.053). Arrhythmia recurrence was also more common in the silent PV group (66.7% vs 50.6%; p=0.047). After multivariable adjustment, female sex (aHR 2.35 [95% CI 2.35-3.96]; p=0.001) and ischaemic heart disease (aHR 3.21 [95% CI 1.56-6.62]; p=0.002) were independently associated with the primary outcome, and left atrial enlargement (aHR 1.58 [95% CI 1.20-2.08]; p=0.001) and >1 prior ablation (aHR 1.88 [95% CI 1.30-2.72]; p<0.001) were independently associated with arrhythmia recurrence. Whilst a finding of silent PVs was not itself significant after multivariable adjustment, this provides an easily assessable parameter at clinically indicated redo ablation which informs the clinician of the likelihood of a worse future prognosis. CONCLUSIONS: Patients with silent PVs at redo AF ablation have worse clinical outcomes.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Reoperação , Humanos , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Feminino , Masculino , Ablação por Cateter/métodos , Pessoa de Meia-Idade , Recidiva , Idoso , Estudos Retrospectivos
17.
J Arrhythm ; 40(3): 501-507, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38939768

RESUMO

Background: Patients who have recurrent atrial fibrillation (AF) following redo catheter ablation may eventually be managed with a pace-and-ablate approach, involving pacemaker implant followed by atrioventricular nodal ablation (AVNA). We sought to determine which factors would predict subsequent AVNA in patients undergoing redo AF ablation. Methods: We analyzed patients undergoing redo AF ablations between 2013 and 2019 at our institution. Follow-up was censored on December 31, 2021. Patients with no available follow-up data were excluded. Time-to-event analysis with Cox proportional hazard regression was used to compare those who underwent AVNA to those who did not. Results: A total of 467 patients were included, of whom 39 (8.4%) underwent AVNA. After multivariable adjustment, female sex (aHR 4.68 [95% CI 2.30-9.50]; p < 0.001), ischemic heart disease (aHR 2.99 [95% CI 1.25-7.16]; p = 0.014), presence of a preexisting pacemaker (aHR 3.25 [95% CI 1.10-9.60]; p = 0.033), and persistent AF (aHR 2.22 [95% CI 1.07-4.59]; p = 0.032) were associated with increased risk of subsequent AVNA requirement. Conclusion: Female sex, ischemic heart disease, and persistent AF may be useful clinical predictors of the requirement for subsequent AVNA and may be considered as part of shared clinical decision making.

18.
Heart Rhythm ; 21(9): 1545-1554, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38636929

RESUMO

BACKGROUND: No study has assessed the durability of pulmonary vein isolation (PVI) with radiofrequency (RF) and cryoballoon (CB) in patients with persistent atrial fibrillation. These data are especially lacking for those with significantly diseased left atria (LA). OBJECTIVES: The goals of this study were to assess PVI durability in patients with significant LA disease and to compare reconnection rates between RF and CB. METHODS: Forty-four patients (mean age 63 years; 34 (77%) male; median time since atrial fibrillation diagnosis 22.5 months; median indexed LA volume 36 mL/m2) were randomized 1:1 to RF or CB PVI. A redo procedure using ultra-high-density electroanatomic mapping was mandated at 2 months, where PV reconnections were identified and reisolated. RESULTS: Thirty-eight patients underwent both procedures (CB n = 17; RF n = 21). Index RF procedures were longer (median 158 minutes vs 97 minutes; P < .001) but required less fluoroscopy (9.5 minutes vs 23 minutes; P < .001). At the index RF procedure, a median of 47% of LA myocardium had voltage < 0.5 mV, suggesting that half of the mapped LA comprised scar. PV reconnection was observed in 73 of 152 PVs (48.0%) and was more frequent with CB (58.8%) than with RF (39.3%) (P = .022). Reconnection of at least 1 PV was detected in >75% of patients. Significantly more ablation was required during the redo procedure to reisolate PVs in the CB arm (median 10.8 minutes vs 1.2 minutes; P < .001). CONCLUSION: PVI durability may be poor in those with significant LA scarring and dilatation, even with modern thermal ablation technologies. RF resulted in significantly better PVI durability than did CB in this complex population.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Veias Pulmonares/cirurgia , Masculino , Feminino , Pessoa de Meia-Idade , Ablação por Cateter/métodos , Criocirurgia/métodos , Resultado do Tratamento , Seguimentos , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Fatores de Tempo , Recidiva , Reoperação/estatística & dados numéricos , Idoso , Átrios do Coração/fisiopatologia
19.
Heart Rhythm ; 21(9): 1537-1544, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38763378

RESUMO

BACKGROUND: With the exponential growth of catheter ablation for atrial fibrillation (AF), there is increasing interest in associated health care costs. Pulsed field ablation (PFA) using a single-shot pentaspline multielectrode catheter has been shown to be safe and effective for AF ablation, but its cost efficiency compared to conventional thermal ablation modalities (cryoballoon [CB] or radiofrequency [RF]) has not been evaluated. OBJECTIVE: The purpose of this study was to compare cost, efficiency, effectiveness, and safety between PFA, CB, and RF for AF ablation. METHODS: We studied 707 consecutive patients (PFA: 208 [46.0%]; CB: 325 [29.4%]; RF: 174 [24.6%]) undergoing first-time AF ablation. Individual procedural costs were calculated, including equipment, laboratory use, and hospital stay, and compared between ablation modalities, as were effectiveness and safety. RESULTS: Skin-to-skin times and catheter laboratory times were significantly shorter with PFA (68 and 102 minutes, respectively) than with CB (91 and 122 minutes) and RF (89 and 123 minutes) (P < .001). General anesthesia use differed across modalities (PFA 100%; CB 10.2%; RF 61.5%) (P < .001). Major complications occurred in 1% of cases, with no significant differences between modalities. Shorter procedural times resulted in lower staffing and laboratory costs with PFA, but these savings were offset by substantially higher equipment costs, resulting in higher overall median costs with PFA (£10,010) than with CB (£8106) and RF (£8949) (P < .001). CONCLUSION: In this contemporary real-world study of the 3 major AF ablation modalities used concurrently, PFA had shorter skin-to-skin and catheter laboratory times than did CB and RF, with similarly low rates of complications. However, PFA procedures were considerably more expensive, largely because of higher equipment cost.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/cirurgia , Fibrilação Atrial/economia , Humanos , Masculino , Feminino , Ablação por Cateter/métodos , Ablação por Cateter/economia , Pessoa de Meia-Idade , Resultado do Tratamento , Análise Custo-Benefício , Estudos Retrospectivos , Idoso , Criocirurgia/métodos , Criocirurgia/economia , Seguimentos
20.
J Interv Card Electrophysiol ; 66(2): 445-453, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35997848

RESUMO

BACKGROUND: Very high power short duration (vHPSD) radiofrequency ablation (RFA) may reduce ablation times and improve patient tolerability, permitting pulmonary vein isolation (PVI) under mild conscious sedation (mCS) and promoting same day discharge (SDD). METHODS: First, a retrospective feasibility study was performed at 2 tertiary cardiac centres in the UK. Consecutive cases of first-time PVI using vHPSD ablation with 90 W lesions for up to 4 s were compared against cases performed using standard RF (sRF) and cryoballoon (Cryo) therapy. Subsequently, a prospective study of patients who had vHPSD or Cryo exclusively under mCS was undertaken. Questionnaires based on Likert and visual analogue scales (VAS) were used to measure anxiety, discomfort and pain. RESULTS: In total, 182 patients (59 vHPSD, 62 sRF and 61 Cryo) were included in the retrospective study, with 53 (90%) of vHPSD cases successfully performed under mCS. PVI ablation time in the vHPSD group (5.8 ± 1.7 min) was shorter than for sRF (16.5 ± 6.3 min, p < 0.001) and Cryo (17.5 ± 5.9 min, p < 0.001). Fifty-one vHPSD and 52 Cryo patients were included in the prospective study. PVI ablation time in the vHPSD group was shorter than for the Cryo group (6.4 ± 2.9 min vs 17.9 ± 5.7 min, p < 0.001), but overall procedure duration was longer (121 ± 39 min vs 95 ± 20 min, p < 0.001). There were no differences in the patient experience of anxiety, discomfort or pain. SDD rates were the same in both groups (61% vs 67%, p = 0.49). CONCLUSIONS: vHPSD RFA for PVI can be performed under mCS to achieve SDD rates comparable to cryoablation, without compromising patient experience.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Ablação por Radiofrequência , Humanos , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Estudos Prospectivos , Sedação Consciente , Resultado do Tratamento , Avaliação de Resultados da Assistência ao Paciente , Veias Pulmonares/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA