RESUMO
Mastitis is a benign inflammatory process of the breast with heterogeneous histopathological findings, which clinically and radiographically may mimic a mammary carcinoma. We undertook a retrospective study on 37 cases of mastitis in our institution to correlate the radiographic imaging features and the clinical presentation with the histopathological findings. Histologically, there were 21 granulomatous, 7 fibrous, 3 plasma cell, 3 lupus, 2 lymphocytic, and 1 case of acute mastitis. Radiographically, 16/25 (64%) patients with ultrasound studies showed irregular hypoechoic masses suspicious for malignancy. Clinically, 38% of patients had an associated systemic disease.
Assuntos
Mastite Granulomatosa/diagnóstico , Mastite Granulomatosa/patologia , Adulto , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/patologia , Feminino , Mastite Granulomatosa/diagnóstico por imagem , Humanos , Mamografia/métodos , Pessoa de Meia-Idade , Estudos Retrospectivos , Ultrassonografia Mamária/métodosRESUMO
PURPOSE: To report the results of a detailed analysis of treatment failures after MammoSite breast brachytherapy for partial breast irradiation from our single-institution experience. METHODS AND MATERIALS: Between October 14, 2002 and October 23, 2006, 78 patients with early-stage breast cancer were treated with breast-conserving surgery and accelerated partial breast irradiation using the MammoSite brachytherapy applicator. We identified five treatment failures in the 70 patients with >6 months' follow-up. Pathologic data, breast imaging, and radiation treatment plans were reviewed. For in-breast failures more than 2 cm away from the original surgical bed, the doses delivered to the areas of recurrence by partial breast irradiation were calculated. RESULTS: At a median follow-up time of 26.1 months, five treatment failures were identified. There were three in-breast failures more than 2 cm away from the original surgical bed, one failure directly adjacent to the original surgical bed, and one failure in the axilla with synchronous distant metastases. The crude failure rate was 7.1% (5 of 70), and the crude local failure rate was 5.7% (4 of 70). Estimated progression-free survival at 48 months was 89.8% (standard error = 4.5%). CONCLUSIONS: Our case series of 70 patients with >6 months' follow-up and a median follow-up of 26 months is the largest single-institution report to date with detailed failure analysis associated with MammoSite brachytherapy. Our failure data emphasize the importance of patient selection when offering partial breast irradiation.