1.
J Clin Monit Comput ; 29(2): 279-89, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25022983

RESUMO

Atrial fibrillation (AF) is often successfully treated by catheter ablation. Those cases of AF that do not readily succumb to ablation therapy would benefit from improved methods for mapping the complex spatial patterns of tissue activation that typify recalcitrant AF. To this end, the purpose of our study was to investigate the use of numerical deconvolution to improve the spatial resolution of activation maps provided by 2-D arrays of intra-cardiac recording electrodes. We simulated tissue activation patterns and their corresponding electric potential maps using a computational model of cardiac electrophysiology, and sampled the maps over a grid of locations to generate a mapping data set. Following cubic spline interpolation, followed by edge-extension and windowing, we deconvolved the data and compared the results to the model current density fields. We performed a similar analysis on voltage-sensitive dye maps obtained in isolated sheep hearts. For both the synthetic data and the voltage-sensitive dye maps, we found that deconvolution led to visually improved map resolution for arrays of 10×10 up to 30×30 electrodes placed within a few mm of the atrial surface when the activation patterns included 3-4 features that spanned the recording area. Root mean square error was also reduced by deconvolution. Deconvolution of arrays of intracardiac potentials, preceded by appropriate interpolation and edge processing, leads to potentially useful improvements in map resolution that may allow more effective assessment of the spatiotemporal dynamics of tissue excitation during AF.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Mapeamento Potencial de Superfície Corporal/métodos , Sistema de Condução Cardíaco/fisiopatologia , Interpretação de Imagem Assistida por Computador/métodos , Imagens com Corantes Sensíveis à Voltagem/métodos , Algoritmos , Animais , Feminino , Humanos , Aumento da Imagem/métodos , Técnicas In Vitro , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ovinos , Processamento de Sinais Assistido por Computador
2.
J Clin Monit Comput ; 28(2): 157-63, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24068576

RESUMO

To improve spatial resolution in recordings of intra-cardiac electrograms we characterized the utility of a novel configuration of two recording electrodes arranged perpendicularly to the endocardial surface. We hypothesized that this configuration denoted as orthogonal close unipolar (OCU) would combine advantages of conventional unipolar and contact bipolar (CBP) configurations. Electrical excitation was simulated in a computational model as arising from dipole current or from multi-wavelet reentry sources. Recordings were calculated for electrode tips 1 mm above the plane of the heart. Analogous recordings were obtained from swine hearts. Electrograms recorded with CBP showed strong dependence on orientation of the electrode pair with respect to the direction of spread of tissue excitation. By contrast, OCU recordings exhibited no directional dependence. OCU was significantly superior to CBP with respect to avoidance of far-field confounding of local tissue activity; the average far-field/near-field ratios for CBP and OCU were 0.09 and 0.05, respectively, for the simulated dipole current sources. In the swine hearts the ratios of ventricular to atrial signals for CBP and OCU were 0.15 ± 0.07 and 0.08 ± 0.09, respectively (p < 0.001). The difference between the actual dominant frequency in the tissue and that recorded by the electrodes was 0.44 ± 0.33 Hz for OCU, 0.58 ± 0.40 Hz for unipolar, and 0.62 ± 0.46 Hz for CBP. OCU confers improved spatial resolution compared with both unipolar and CBP electrode configurations. Unlike the case with CBP, OCU recordings are independent of excitation wave-front direction.


Assuntos
Mapeamento Potencial de Superfície Corporal/instrumentação , Mapeamento Potencial de Superfície Corporal/métodos , Diagnóstico por Computador/métodos , Eletrodos , Mapeamento Epicárdico/métodos , Modelos Cardiovasculares , Suínos , Algoritmos , Animais , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Análise Espaço-Temporal
3.
Europace ; 14 Suppl 5: v106-v111, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23104906

RESUMO

AIMS: Catheter ablation strategies for treatment of cardiac arrhythmias are quite successful when targeting spatially constrained substrates. Complex, dynamic, and spatially varying substrates, however, pose a significant challenge for ablation, which delivers spatially fixed lesions. We describe tissue excitation using concepts of surface topology which provides a framework for addressing this challenge. The aim of this study was to test the efficacy of mechanism-based ablation strategies in the setting of complex dynamic substrates. METHODS AND RESULTS: We used a computational model of propagation through electrically excitable tissue to test the effects of ablation on excitation patterns of progressively greater complexity, from fixed rotors to multi-wavelet re-entry. Our results indicate that (i) focal ablation at a spiral-wave core does not result in termination; (ii) termination requires linear lesions from the tissue edge to the spiral-wave core; (iii) meandering spiral-waves terminate upon collision with a boundary (linear lesion or tissue edge); (iv) the probability of terminating multi-wavelet re-entry is proportional to the ratio of total boundary length to tissue area; (v) the efficacy of linear lesions varies directly with the regional density of spiral-waves. CONCLUSION: We establish a theoretical framework for re-entrant arrhythmias that explains the requirements for their successful treatment. We demonstrate the inadequacy of focal ablation for spatially fixed spiral-waves. Mechanistically guided principles for ablating multi-wavelet re-entry are provided. The potential to capitalize upon regional heterogeneity of spiral-wave density for improved ablation efficacy is described.


Assuntos
Potenciais de Ação , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Modelos Cardiovasculares , Cirurgia Assistida por Computador/métodos , Taquicardia Reciprocante/fisiopatologia , Taquicardia Reciprocante/cirurgia , Animais , Simulação por Computador , Humanos , Resultado do Tratamento
4.
Pacing Clin Electrophysiol ; 34(11): 1460-7, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21883315

RESUMO

BACKGROUND: Ablation of atrial autonomic inputs exerts antifibrillatory effects. However, because ablation destroys both myocardium and nerve cells, the effect of autonomic withdrawal alone remains unclear. We therefore examined the effects of pharmacologic autonomic blockade (PAB) on frequency and fractionation in patients with atrial fibrillation (AF). METHODS: Esmolol and atropine were administered and electrograms were recorded simultaneously from both atria and the coronary sinus. In 17 patients, AF was recorded for 5 minutes and dominant frequency (DF) and continuous activity (CA) were compared before and during PAB. RESULTS: Examination of the pooled data (537 sites, 17 patients) revealed a statistically significant decrease in mean DF (5.61­5.43Hz, P < 0.001) during PAB. Site-by-site analysis showed that 67% of sites slowed (0.45 ± 0.59 Hz), whereas 32% accelerated (0.49 ± 0.59Hz). Fractionation was reduced: median CA decreased from 31% to 26% (P < 0.001). In patient-by-patient analysis, mean DF/median CA decreased in 13 of 17 patients and increased in four. The spatial heterogeneity of DF decreased in nine of 17 patients (spatial coefficient of variation of DF at "nondriver sites" decreased by a mean of 2%). CONCLUSION: PAB decreases DF and CA in the majority of sites. Given the complexity of interactions between atrial cells during AF, the effects of PAB on DF and fractionation are more heterogeneous than the effects of PAB on isolated cells.


Assuntos
Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/fisiopatologia , Eletrocardiografia/efeitos dos fármacos , Frequência Cardíaca/efeitos dos fármacos , Parassimpatolíticos/uso terapêutico , Simpatolíticos/uso terapêutico , Antagonistas de Receptores Adrenérgicos beta 1/uso terapêutico , Fibrilação Atrial/diagnóstico , Atropina/uso terapêutico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Bloqueio Nervoso/métodos , Propanolaminas/uso terapêutico , Sistema Nervoso Simpático/efeitos dos fármacos , Resultado do Tratamento
5.
Front Physiol ; 12: 633643, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33796028

RESUMO

BACKGROUND: There is debate whether human atrial fibrillation is driven by focal drivers or multiwavelet reentry. We propose that the changing activation sequences surrounding a focal driver can at times self-sustain in the absence of that driver. Further, the relationship between focal drivers and surrounding chaotic activation is bidirectional; focal drivers can generate chaotic activation, which may affect the dynamics of focal drivers. METHODS AND RESULTS: In a propagation model, we generated tissues that support structural micro-reentry and moving functional reentrant circuits. We qualitatively assessed (1) the tissue's ability to support self-sustaining fibrillation after elimination of the focal driver, (2) the impact that structural-reentrant substrate has on the duration of fibrillation, the impact that micro-reentrant (3) frequency, (4) excitable gap, and (5) exposure to surrounding fibrillation have on micro-reentry in the setting of chaotic activation, and finally the likelihood fibrillation will end in structural reentry based on (6) the distance between and (7) the relative lengths of an ablated tissue's inner and outer boundaries. We found (1) focal drivers produced chaotic activation when waves encountered heterogeneous refractoriness; chaotic activation could then repeatedly initiate and terminate micro-reentry. Perpetuation of fibrillation following elimination of micro-reentry was predicted by tissue properties. (2) Duration of fibrillation was increased by the presence of a structural micro-reentrant substrate only when surrounding tissue had a low propensity to support self-sustaining chaotic activation. Likelihood of micro-reentry around the structural reentrant substrate increased as (3) the frequency of structural reentry increased relative to the frequency of fibrillation in the surrounding tissue, (4) the excitable gap of micro-reentry increased, and (5) the exposure of the structural circuit to the surrounding tissue decreased. Likelihood of organized tachycardia following termination of fibrillation increased with (6) decreasing distance and (7) disparity of size between focal obstacle and external boundary. CONCLUSION: Focal drivers such as structural micro-reentry and the chaotic activation they produce are continuously interacting with one another. In order to accurately describe cardiac tissue's propensity to support fibrillation, the relative characteristics of both stationary and moving drivers must be taken into account.

6.
Circ Arrhythm Electrophysiol ; 11(8): e006536, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30354312

RESUMO

BACKGROUND: Activation mapping of scar-related atrial tachycardias (ATs) can be difficult to interpret because of inaccurate time annotation of complex electrograms and passive diastolic activity. We examined whether integration of a vector map can help to describe patterns of propagation to better explain the mechanism and location of ATs. METHODS: The investigational mapping algorithm calculates vectors and applies physiological constraints of electrical excitation in human atrial tissue to determine the arrhythmia source and circuit. Phase I consisted of retrospective evaluation in 35 patients with ATs. Phase II consisted of prospective validation in 20 patients with ATs. Macroreentry was defined as a continuous propagation in a circular path >30 mm; localized reentry was defined as a circular path ≤30 mm; a focal source had a centrifugal spread from a point source. RESULTS: In phase I, standard activation mapping identified 28 of 40 ATs (70%): 25 macroreentry and 3 focal tachycardias. In the remaining 12 ATs, the mechanism and location could not be identified by activation and required entrainment or empirical ablation for termination (radiofrequency time, 17.3±6.6 minutes). In comparison, the investigational algorithm identified 37 of 40 (92.5%) ATs, including 5 macroreentry, 3 localized reentry, and 1 focal AT not identified by standard mapping. It also predicted the successful termination site of all 37 of 40 ATs. In phase II, the investigational algorithm identified 12 macroreentry, 6 localized reentry, and 2 focal tachycardias that all terminated with limited ablation (3.2±1.7 minutes). It identified 3 macroreentry, 3 localized reentry, and 1 focal AT not well characterized by standard mapping. The diagnosis of localized reentry was supported by highly curved vectors, resetting with increasing curve and termination with limited ablation (22±6 s). CONCLUSIONS: Activation mapping integrating vectors can help determine the arrhythmia mechanism and identify its critical components. It has particular value for identifying complex macroreentrant circuits and for differentiating a focal source from a localized reentry.


Assuntos
Potenciais de Ação , Remodelamento Atrial , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração/fisiopatologia , Frequência Cardíaca , Processamento de Sinais Assistido por Computador , Taquicardia Supraventricular/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Bélgica , Ablação por Cateter , Feminino , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudo de Prova de Conceito , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/cirurgia , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
7.
Coron Artery Dis ; 17(2): 125-30, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16474230

RESUMO

Radiofrequency ablation of complex cardiac arrhythmias has undergone significant evolution in the past decade, with the development of technology enabling better anatomic and electrophysiologic mapping of abnormal cardiac tissue. In this paper, we will discuss the role of pre-procedural and post-procedural multidetector computed tomography, with specific focus on the anatomic assessment of pulmonary vein and left atrial anatomy in the ablation of atrial fibrillation. We will also consider how the integration of both multidetector computed tomography and electroanatomic computer-based imaging may contribute more broadly to the management of a variety of complex ablation procedures.


Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Angiografia Coronária/métodos , Coração/diagnóstico por imagem , Tomografia Computadorizada Espiral/métodos , Aortografia , Ablação por Cateter/efeitos adversos , Constrição Patológica/diagnóstico por imagem , Esôfago/diagnóstico por imagem , Humanos , Veias Pulmonares/diagnóstico por imagem , Ondas de Rádio/efeitos adversos
8.
Artigo em Inglês | MEDLINE | ID: mdl-26962094

RESUMO

BACKGROUND: Treatment of multiwavelet reentry (MWR) remains difficult. We previously developed a metric, the fibrillogenicity index, to assess the propensity of homogeneous, 2-dimensional tissues to support MWR. In this study, we demonstrate a method by which fibrillogenicity index can be generalized to heterogeneous tissues and validate an algorithm for prospective, tissue-specific optimization of ablation to reduce MWR burden. METHODS AND RESULTS: We used a computational model to simulate and measure the duration of MWR in tissues with heterogeneously distributed action potential durations and then assessed the relative efficacy of a variety of ablation strategies for reducing tissues' ability to support MWR. We then derived and tested a strategy in which multiple linear lesions partially divided a fibrillogenic tissue into functionally equivalent subsections. The composite action potential duration of heterogeneous tissue was well approximated by an inverse sum of cellular action potential durations (R(2)=0.82). Linear ablation more efficiently reduced MWR duration than branching ablation patterns and optimally reduced disease burden when positioned at a tissue's functional (rather than geometric) center. The duration of MWR after application of prospective, individually optimized ablation sets fell within 4.4% (95% confidence interval, 3-5.8) of the predicted target. CONCLUSIONS: We think that this study presents a novel approach for (1) quantifying the extent of a tissue's electric derangement, (2) prospectively determining the amount of ablation required to minimize the burden of MWR, and (3) predicting the most efficient distribution of these ablation lesions in tissue refractory to standard ablation strategies.


Assuntos
Algoritmos , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/cirurgia , Potenciais de Ação , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Simulação por Computador , Técnicas de Apoio para a Decisão , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Humanos , Cinética , Modelos Cardiovasculares , Seleção de Pacientes , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes
9.
Heart Rhythm ; 2(1): 82-90, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15851270

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the safety and efficacy of cryoablation in a closed chest canine epicardial ablation model. BACKGROUND: Limitations of radiofrequency energy in the epicardial space warrants investigation of alternative energy sources. METHODS: A linear-tip catheter with a 3-cm freezing element and a 6-mm-tip catheter were used to create epicardial atrial and ventricular cryolesions. Epicardial coronary arteries were targeted to evaluate the effects of cryoablation on epicardial vessels. Cryoablation was performed at -90 degrees C for 4 minutes per lesion. Pathologic examination of the hearts was performed. Lesions were stained with tetrazolium chloride, analyzed grossly, and examined histologically. RESULTS: Ten of 11 linear catheter atrial lesions were transmural (average depth 1.5 +/- 1.3 mm). Only three of 13 6-mm-tip atrial lesions were transmural (average depth 1.1 +/- 1.2 mm). Ventricular lesions were continuous and not transmural (average depth of lesion for the linear and 6-mm-tip catheters: 2.7 +/- 1.3 mm and 1.6 +/- 0.7 mm, respectively). Angiographic stenosis (20-100%) during freezing was detected in 9 of 28 lesions, with TIMI III flow present in all vessels 5 minutes following thaw. Neointimal proliferation was present in 13 vessels, with no evidence of damage in vessels with internal diameters greater than 0.7 mm. Occlusive injury was identified in one small branch vessel. CONCLUSIONS: Creation of transmural lesions was possible in the atria but not in the ventricles. Cryothermal ablation can cause neointimal proliferation, with the probability that damage will be directly proportional to lesion depth and inversely proportional to vessel diameter.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Criocirurgia , Pericárdio/cirurgia , Animais , Angiografia Coronária , Vasos Coronários/cirurgia , Criocirurgia/instrumentação , Cães , Ecocardiografia
10.
PLoS One ; 10(3): e0119535, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25756656

RESUMO

Biological networks are typically comprised of many parts whose interactions are governed by nonlinear dynamics. This potentially imbues them with the ability to support multiple attractors, and therefore to exhibit correspondingly distinct patterns of behavior. In particular, multiple attractors have been demonstrated for the electrical activity of the diseased heart in situations where cardioversion is able to convert a reentrant arrhythmia to a stable normal rhythm. Healthy hearts, however, are typically resilient to abnormal rhythms. This raises the question as to how a healthy cardiac cell network must be altered so that it can support multiple distinct behaviors. Here we demonstrate how anatomic defects can give rise to multi-stability in the heart as a function of the electrophysiological properties of the cardiac tissue and the timing of activation of ectopic foci. This leads to a form of hysteretic behavior, which we call dynamic entrapment, whereby the heart can become trapped in aberrant attractor as a result of a transient change in tissue properties. We show that this can lead to a highly inconsistent relationship between clinical symptoms and underlying pathophysiology, which raises the possibility that dynamic entrapment may underlie other forms of chronic idiopathic illness.


Assuntos
Arritmias Cardíacas/fisiopatologia , Modelos Cardiovasculares , Algoritmos , Arritmias Cardíacas/patologia , Simulação por Computador , Sistema de Condução Cardíaco , Humanos
11.
PLoS One ; 10(3): e0118746, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25768978

RESUMO

The goal of this study was to determine quantitative relationships between electrophysiologic parameters and the propensity of cardiac tissue to undergo atrial fibrillation. We used a computational model to simulate episodes of fibrillation, which we then characterized in terms of both their duration and the population dynamics of the electrical waves which drove them. Monte Carlo sampling revealed that episode durations followed an exponential decay distribution and wave population sizes followed a normal distribution. Half-lives of reentrant episodes increased exponentially with either increasing tissue area to boundary length ratio (A/BL) or decreasing action potential duration (APD), resistance (R) or capacitance (C). We found that the qualitative form of fibrillatory activity (e.g., multi-wavelet reentry (MWR) vs. rotors) was dependent on the ratio of resistance and capacitance to APD; MWR was reliably produced below a ratio of 0.18. We found that a composite of these electrophysiologic parameters, which we term the fibrillogenicity index (Fb = A/(BL*APD*R*C)), reliably predicted the duration of MWR episodes (r2 = 0.93). Given that some of the quantities comprising Fb are amenable to manipulation (via either pharmacologic treatment or catheter ablation), these findings provide a theoretical basis for the development of titrated therapies of atrial fibrillation.


Assuntos
Fibrilação Atrial/fisiopatologia , Fenômenos Eletrofisiológicos , Modelos Cardiovasculares , Animais , Coração/fisiopatologia , Humanos , Probabilidade
12.
Circ Arrhythm Electrophysiol ; 6(6): 1229-35, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24036225

RESUMO

BACKGROUND: A key mechanism responsible for atrial fibrillation is multiwavelet re-entry (MWR). We have previously demonstrated improved efficiency of ablation when lesions were placed in regions of high circuit-density. In this study, we undertook a quantitative assessment of the relative effect of ablation on the probability of MWR termination and the inducibility of MWR, as a function of lesion length and circuit-density overlap. METHODS AND RESULTS: We used a computational model to simulate MWR in tissues with (and without) localized regions of decreased action potential duration and increased intercellular resistance. We measured baseline circuit-density and distribution. We then assessed the effect of various ablation lesion sets on the inducibility and duration of MWR as a function of ablation lesion length and overlap with circuit-density. Higher circuit-density reproducibly localized to regions of shorter wavelength. Ablation lines with high circuit-density overlap showed maximum decreases in duration of MWR at lengths equal to the distance from the tissue boundary to the far side of the high circuit-density region (high-overlap, -43.5% [confidence interval, -22.0% to -65.1%] versus low-overlap, -4.4% [confidence interval, 7.3% to -16.0%]). Further ablation (beyond the length required to cross the high circuit-density region) provided minimal further reductions in duration and increased inducibility. CONCLUSIONS: Ablation at sites of high circuit-density most efficiently decreased re-entrant duration while minimally increasing inducibility. Ablation lines delivered at sites of low circuit-density minimally decreased duration yet increased inducibility of MWR.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Sistema de Condução Cardíaco/fisiopatologia , Potenciais de Ação/fisiologia , Algoritmos , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração/fisiopatologia , Humanos , Miócitos Cardíacos/fisiologia , Resultado do Tratamento
13.
Coron Artery Dis ; 23(2): 126-32, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22258280

RESUMO

BACKGROUND: Electrogram fractionation can result when multiple groups of cardiac cells are excited asynchronously within the recording region of a mapping electrode. The spatial resolution of an electrode thus plays an important role in mapping complex rhythms. METHODS: We used a computational model, validated against experimental measurements in vitro, to determine how spatial resolution is affected by electrode diameter, electrode length, interelectrode distance (in the case of bipolar recordings), and height of the electrode above a dipole current source. RESULTS: We found that increases in all these quantities caused progressive degradation in two independent measures of spatial resolution, with the strongest effect being due to changes in height above the tissue. CONCLUSION: Our calculations suggest that if electrodes could be constructed to have negligible dimensions compared with those in use today, we would increase resolution by about one order of magnitude at most.


Assuntos
Simulação por Computador , Eletrodos Implantados , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Sistema de Condução Cardíaco/fisiologia , Desenho de Equipamento , Humanos , Reprodutibilidade dos Testes
14.
Circ Arrhythm Electrophysiol ; 4(6): 909-16, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21984446

RESUMO

BACKGROUND: Fractionated electrograms are used by some as targets for ablation in atrial and ventricular arrhythmias. Fractionation has been demonstrated to result when there is repetitive or asynchronous activation of separate groups of cells within the recording region of a mapping electrode(s). METHODS AND RESULTS: Using a computer model, we generated tissue activation patterns with increasing spatiotemporal variation and calculated virtual electrograms from electrodes with decreasing resolution. We then quantified electrogram fractionation. In addition, we recorded unipolar electrograms during atrial fibrillation in 20 patients undergoing atrial fibrillation ablation. From these we constructed bipolar electrograms with increasing interelectrode spacing and quantified fractionation. During modeling of spatiotemporal variation, fractionation varied directly with electrode length, diameter, height, and interelectrode spacing. When resolution was held constant, fractionation increased with increasing spatiotemporal variation. In the absence of spatial variation, fractionation was independent of resolution and proportional to excitation frequency. In patients with atrial fibrillation, fractionation increased as interelectrode spacing increased. CONCLUSIONS: We created a model for distinguishing the roles of spatial and temporal electric variation and electrode resolution in producing electrogram fractionation. Spatial resolution affects fractionation attributable to spatiotemporal variation but not temporal variation alone. Electrogram fractionation was directly proportional to spatiotemporal variation and inversely proportional to spatial resolution. Spatial resolution limits the ability to distinguish high-frequency excitation from overcounting. In patients with atrial fibrillation, complex fractionated atrial electrogram detection varies with spatial resolution. Electrode resolution must therefore be considered when interpreting and comparing studies of fractionation.


Assuntos
Fibrilação Atrial/diagnóstico , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Idoso , Algoritmos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Simulação por Computador , Eletrodos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Desenho de Equipamento , Sistema de Condução Cardíaco/cirurgia , Humanos , Modelos Lineares , Pessoa de Meia-Idade , Modelos Cardiovasculares , Valor Preditivo dos Testes , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Vermont
15.
Heart Rhythm ; 7(1): 15-21, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19914142

RESUMO

BACKGROUND: Biventricular pacing (BiV) to effect cardiac resynchronization therapy can be technically difficult and fails to elicit a clinical response in 30% to 40% of patients. Direct His-bundle pacing (DHBP) theoretically could obviate some of these problems. Although DHBP is capable of narrowing the QRS in some patients, the consistency with which this can be achieved has not been characterized. OBJECTIVE: The purpose of this study was to restore His-Purkinje functionality in consecutive patients undergoing de novo clinically mandated cardiac resynchronization therapy. METHODS: DHBP was temporarily implemented at the time of implantation of a permanent BiV system in patients referred for cardiac resynchronization therapy. Native conduction, DHBP, and BiV QRS duration were compared. All patients presenting for BiV cardiac resynchronization therapy were eligible for the study. Ten patients were studied. RESULTS: DHBP was successfully implemented in all 10 patients. In 7 of 10 patients, DHBP narrowed the QRS significantly compared with native conduction and BiV (mean QRS duration: native 171 +/- 13 ms, DHBP 148 +/- 11 ms, BiV 158 +/- 21, P <.0001). QRS narrowing with DHBP was specifically attributable to capture of latent His-Purkinje tissue. DHBP lead implantation time (16 minutes) was shorter than standard left ventricular lead implantation time (42 minutes). CONCLUSION: DHBP was readily implemented in patients with standard indications for BiV cardiac resynchronization therapy. In most patients studied, DHBP resulted in a significantly narrower QRS compared with native conduction. DHBP may offer a physiologic alternative to BiV for cardiac resynchronization therapy.


Assuntos
Fascículo Atrioventricular , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/métodos , Bloqueio de Ramo/fisiopatologia , Estudos de Viabilidade , Humanos , Células de Purkinje , Volume Sistólico , Função Ventricular Esquerda
16.
Artigo em Inglês | MEDLINE | ID: mdl-19964323

RESUMO

Multi-electrode catheters can be placed transvenously and positioned on the atrial endocardial surface in order to sample the chaotic electrical activity taking place during atrial fibrillation. We consider here the possibility of placing an array of electrodes over a relatively small, and hence roughly planar, region of the atrial surface in order to examine local activity patterns. This provides a spatially coarse but temporally fine sampling of electrical activity that can be expressed at each point in time as the convolution of the true electrical excitation of the tissue with a hyperbolic point spread function. We demonstrate the deconvolution of sampled signals using a polynomial approximation of the true electrical activity. When the deconvolution is unconstrained the inverse problem is poorly conditioned, showing that a high spatial sampling rate is required for accurate reconstructions of atrial activity in the vicinity of the electrode array. We discuss ways in which the conditioning of the problem might be improved through the application of constraints on the solution.


Assuntos
Fibrilação Atrial/fisiopatologia , Eletrofisiologia/métodos , Coração/fisiologia , Potenciais de Ação , Fibrilação Atrial/terapia , Cateterismo , Eletrodos , Eletrodos Implantados , Coração/fisiopatologia , Humanos , Modelos Estatísticos , Modelos Teóricos , Nanotecnologia/métodos , Distribuição Normal , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Fatores de Tempo