Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Nanomedicine ; 13(8): 2633-2642, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28757180

RESUMO

Many nanoparticles are designed for use as potential nanomedicines for parenteral administration. However, emerging evidence suggests that hemocompatibility is important, but is highly particle- and test-bed dependent. Thus, knowledge of bulk material properties does not predict the hemocompatibility of uncharacterized nanoparticles, including silk nanoparticles. This study compares the hemocompatibility of silk versus silica nanoparticles, using whole human blood under quasi-static and flow conditions. Substantial hemocompatibility differences are noted for some nanoparticles in quasi-static versus dynamic studies; i.e., the inflammatory response to silk nanoparticles is significantly lower under flow versus quasi-static conditions. Silk nanoparticles also have very low coagulant properties - an observation that scales from the macro- to the nano-level. These nanoparticle hemocompatibility studies are complemented by preliminary live cell measurements to evaluate the endocytosis and trafficking of nanoparticles in human blood cells. Overall, this study demonstrates that nanoparticle hemocompatibility is affected by several factors, including the test bed design.


Assuntos
Materiais Biocompatíveis/metabolismo , Células Sanguíneas/metabolismo , Nanopartículas/metabolismo , Dióxido de Silício/metabolismo , Seda/metabolismo , Células Sanguíneas/citologia , Coagulação Sanguínea , Endocitose , Humanos , Teste de Materiais , Tamanho da Partícula
2.
Biomater Adv ; 153: 213555, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37478769

RESUMO

Physiologically relevant in vitro hemocompatibility assessment of biomaterials remains challenging. We present a new setup that enables standardized whole blood incubation of biomedical materials under flow. A blood volume of 2 mL is recirculated over test surfaces in a custom-made parallel plate incubation system to determine the activation of hemostasis and inflammation. Controlled physiological shear rates between 125 s-1 and 1250 s-1 and minimized contact to air are combined with a natural-like pumping process. A unique feature of this setup allows tracing adhesion of blood cells to test surfaces microscopically in situ. Validation testing was performed in comparison to previously applied whole blood incubation methodologies. Experiments with the newly developed setup showed that even small obstacles to blood flow activate blood (independent of materials-induced blood activation levels); that adhesion of blood cells to biomaterials equilibrates within 5 to 10 min; that high shear rates (1250 compared to 375 s-1) induce platelet activation; and that hemolysis, platelet factor 4 (PF4) release and platelet loss - but not thrombin formation - depend on shear rate (within the range investigated, 125 to 1250 s-1).


Assuntos
Materiais Biocompatíveis , Plaquetas , Materiais Biocompatíveis/efeitos adversos , Ativação Plaquetária , Hemostasia
3.
Biomater Adv ; 147: 213328, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36764200

RESUMO

Hemocompatibility tuning was adopted to explore and refine an innovative, GA-free preparation strategy combining decellularization, riboflavin/UV crosslinking, and low-energy electron irradiation (SULEEI) procedure. A SULEEI-protocol was established to avoid GA-dependent deterioration that results in insufficient long-term aortic valve bioprosthesis durability. Final SULEEI-pericardium, intermediate steps and GA-fixed reference pericardium were exposed in vitro to fresh human whole blood to elucidate effects of preparation parameters on coagulation and inflammation activation and tissue histology. The riboflavin/UV crosslinking step showed to be less efficient in inactivating extracellular matrix (ECM) protein activity than the GA fixation, leading to tissue-factor mediated blood clotting. Intensifying the riboflavin/UV crosslinking with elevated riboflavin concentration and dextran caused an enhanced activation of the complement system. Yet activation processes induced by the previous protocol steps were quenched with the final electron beam treatment step. An optimized SULEEI protocol was developed using an intense and extended, trypsin-containing decellularization step to inactivate tissue factor and a dextran-free, low riboflavin, high UV crosslinking step. The innovative and improved GA-free SULEEI-preparation protocol results in low coagulant and low inflammatory bovine pericardium for surgical application.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Animais , Bovinos , Humanos , Glutaral/metabolismo , Glutaral/farmacologia , Elétrons , Pericárdio/metabolismo , Pericárdio/patologia
4.
J Mater Sci Mater Med ; 21(3): 931-7, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19851837

RESUMO

Biomaterial induced coagulation encompasses plasmatic and cellular processes. The functional loss of biomedical devices possibly resulting from these thrombotic reactions motivates the need for a better understanding of processes occurring at blood-biomaterial interfaces. Well defined model surfaces providing specific chemical-physical properties (self assembled monolayers (SAMs)) displaying hydrophobic or/and acidic terminal groups were used to uncover initial mechanisms of biomaterial induced coagulation. We investigated the influence of electrical charge and wettability on platelet- and contact activation, the two main actors of blood coagulation, which are often considered as separate mechanisms in biomaterials research. Our results show a dependence of contact activation on acidic surface groups and a correlation of platelet adhesion to surface hydrophobicity. Clot formation resulting from the interplay of blood platelets and contact activation was only found on surfaces combining both acidic and hydrophobic surface groups but not on monolayers displaying extreme hydrophobic/acidic properties.


Assuntos
Ânions , Coagulação Sanguínea , Interações Hidrofóbicas e Hidrofílicas , Adsorção , Materiais Biocompatíveis/química , Sangue/metabolismo , Plaquetas/química , Plaquetas/metabolismo , Cristalização , Fator XIIa/química , Fibrinogênio/química , Humanos , Técnicas In Vitro , Calicreínas/química , Adesividade Plaquetária , Molhabilidade
5.
Biomaterials ; 260: 120312, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32866726

RESUMO

Blood-contacting medical devices play an important role within healthcare and are required to be biocompatible, hemocompatible and resistant to microbial colonization. Here we describe a high throughput screen for copolymers with these specific properties. A series of weakly amphiphilic monomers are combinatorially polymerized with acrylate glycol monomers of varying chain lengths to create a library of 645 multi-functional candidate materials containing multiple chemical moieties that impart anti-biofilm, hemo- and immuno-compatible properties. These materials are screened in over 15,000 individual biological assays, targeting two bacterial species, one Gram negative (Pseudomonas aeruginosa) and one Gram positive (Staphylococcus aureus) commonly associated with central venous catheter infections, using 5 different measures of hemocompatibility and 6 measures of immunocompatibililty. Selected copolymers reduce platelet activation, platelet loss and leukocyte activation compared with the standard comparator PTFE as well as reducing bacterial biofilm formation in vitro by more than 82% compared with silicone. Poly(isobornyl acrylate-co-triethylene glycol methacrylate) (75:25) is identified as the optimal material across all these measures reducing P. aeruginosa biofilm formation by up to 86% in vivo in a murine foreign body infection model compared with uncoated silicone.


Assuntos
Antibacterianos , Infecções Estafilocócicas , Animais , Biofilmes , Camundongos , Pseudomonas aeruginosa , Staphylococcus aureus
6.
Acta Biomater ; 94: 25-32, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31226478

RESUMO

Following protein adsorption/activation which is the first step after the contact of material surfaces and whole blood (part 2), fibrinogen is converted to fibrin and platelets become activated and assembled in the form of a thrombus. This thrombus formation is the key feature that needs to be minimized in the creation of materials with low thrombogenicity. Further aspects of blood compatibility that are important on their own are complement and leukocyte activation which are also important drivers of thrombus formation. Hence this review summarizes the state of knowledge on all of these cascades and cells and their interactions. For each cascade or cell type, the chapter distinguishes statements which are in widespread agreement from statements where there is less of a consensus. STATEMENT OF SIGNIFICANCE: This paper is part 3 of a series of 4 reviews discussing the problem of biomaterial associated thrombogenicity. The objective was to highlight features of broad agreement and provide commentary on those aspects of the problem that were subject to dispute. We hope that future investigators will update these reviews as new scholarship resolves the uncertainties of today.


Assuntos
Materiais Biocompatíveis , Coagulação Sanguínea , Fibrinogênio/metabolismo , Teste de Materiais , Adesividade Plaquetária , Trombose/metabolismo , Adsorção , Animais , Plaquetas/citologia , Proteínas do Sistema Complemento/metabolismo , Fibrina/metabolismo , Hemólise , Humanos , Inflamação , Leucócitos/citologia , Microesferas , Propriedades de Superfície
7.
Acta Biomater ; 94: 33-43, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31226481

RESUMO

Biomedical devices in the blood flow disturb the fine-tuned balance of pro- and anti-coagulant factors in blood and vessel wall. Numerous technologies have been suggested to reduce coagulant and inflammatory responses of the body towards the device material, ranging from camouflage effects to permanent activity and further to a responsive interaction with the host systems. However, not all types of modification are suitable for all types of medical products. This review has a focus on application-oriented considerations of hemocompatible surface fittings. Thus, passive versus bioactive modifications are discussed along with the control of protein adsorption, stability of the immobilization, and the type of bioactive substance, biological or synthetic. Further considerations are related to the target system, whether enzymes or cells should be addressed in arterial or venous system, or whether the blood vessel wall is addressed. Recent developments like feedback controlled or self-renewing systems for drug release or addressing cellular regulation pathways of blood platelets and endothelial cells are paradigms for a generation of blood contacting devices, which are hemocompatible by cooperation with the host system. STATEMENT OF SIGNIFICANCE: This paper is part 4 of a series of 4 reviews discussing the problem of biomaterial associated thrombogenicity. The objective was to highlight features of broad agreement and provide commentary on those aspects of the problem that were subject to dispute. We hope that future investigators will update these reviews as new scholarship resolves the uncertainties of today.


Assuntos
Materiais Biocompatíveis , Plaquetas/citologia , Células Endoteliais/metabolismo , Propriedades de Superfície , Adsorção , Animais , Coagulação Sanguínea , Proteínas Sanguíneas/metabolismo , Fibrinólise , Hemólise , Hemorreologia , Humanos , Teste de Materiais , Camundongos , Polímeros , Resistência ao Cisalhamento , Engenharia Tecidual
8.
ACS Appl Bio Mater ; 1(3): 756-767, 2018 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-34996166

RESUMO

The benefits of nanomedicine may be restricted by hemocompatibility and immunoreactivity problems arising from administration of exogenous materials into the bloodstream. To understand how surface charge influences the interaction of polymeric nanoparticles with blood components, we synthesized three well-defined, charge-varied hyperbranched polymers (HBPs) of similar size and analyzed both hemocompatibility and immunoreactivity of these methacrylate-based HBPs ex vivo using primary human blood cell assays and image analyses following intravenous injection into mice. The results show that, regardless of charge, endotoxin-free HBPs had minimal effects on coagulation, platelet, complement, or T cell activation. However, high concentrations (100 µg mL-1) of cationic HBPs led to significant dendritic cell activation, suggesting the potential application of these nanoparticles as vaccine adjuvants to aid efficient antigen presentation. Biodistribution studies showed that intravenously administered charge-neutral HBPs had a longer retention time in the circulation than cationic or anionic HBPs; whereas these neutral HBPs were eventually cleared in the urine, charged HBPs mainly accumulated in liver and spleen. Overall, these results demonstrate that, regardless of surface charge, HBPs display a high level of hemocompatibility. In contrast, immunoreactivity and biodistribution are significantly influenced by charge. Manipulation of surface charge may thus be a useful method by which nanomaterials such as HBPs can be tailored to different clinical applications.

9.
Biomaterials ; 28(25): 3617-25, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17524475

RESUMO

Complement activation on hydroxyl-group-bearing surfaces is regarded as the main reason for granulocyte activation in applications of blood-contacting medical devices such as extracorporeal blood purification. However, the factors inducing the cell adhesion so far remained ambiguous. For a dedicated research, whole blood was incubated with a set of structurally similar polymer coatings on glass with either hydroxy or ether functionalities. By co-incubation of an activating with a non-activating surface, the reaction of granulocytes activated by complement fragments on non-activating surfaces could be evaluated. As expected, hydroxyl-terminated polymer layers induced much higher levels of complement activation than those with ether functionalities. Leukocyte activation, as measured by the expression of CD11b, correlated closely with the presence of free complement fragment C5a. However, adhesion of leukocytes was rather associated with the adsorption of activated fragments of C3 than with the activation level of the cells. Moreover, it was found that adsorbed quantities of fibrin and fibrinogen had little influence on leukocyte adhesion. It is concluded that the activation of leukocytes is triggered by soluble complement factors such as C5a while their adhesion on hydroxy-bearing surfaces is mainly triggered by the presence of surface-bound complement fragment C3b.


Assuntos
Materiais Biocompatíveis/química , Leucócitos/imunologia , Polímeros/química , Materiais Biocompatíveis/farmacologia , Antígeno CD11b/análise , Adesão Celular/efeitos dos fármacos , Ativação do Complemento/efeitos dos fármacos , Ensaio de Imunoadsorção Enzimática , Fibrina/farmacologia , Fibrinogênio/farmacologia , Citometria de Fluxo , Vidro/química , Granulócitos/citologia , Granulócitos/efeitos dos fármacos , Granulócitos/imunologia , Humanos , Leucócitos/citologia , Leucócitos/efeitos dos fármacos , Estrutura Molecular , Neutrófilos/citologia , Neutrófilos/efeitos dos fármacos , Neutrófilos/imunologia , Polímeros/farmacologia , Relação Estrutura-Atividade , Propriedades de Superfície
10.
Macromol Biosci ; 7(2): 195-200, 2007 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-17295407

RESUMO

The impact of heparinoid characteristics on model surfaces obtained from immobilization of sole sulfate groups as well as sulfated glycosides, sulfated cellulose, and definite heparin has been investigated. The obtained layers were physico-chemically characterized regarding film thickness, chemical composition, wettability, and surface morphology. Antithrombin adsorption, studied by fluorescence labeling, revealed a strong dependence on the presence of glycosidic structures and on the molecular weight of the grafted saccharide. On contact with whole blood, the coatings resulted in a diminished plasmatic and cellular coagulation in vitro, which did not reflect well the antithrombin binding. Therefore, more complex activating pathways are discussed.


Assuntos
Biomimética/métodos , Coagulação Sanguínea , Heparina/química , Anidridos Maleicos/química , Polímeros/química , Ésteres do Ácido Sulfúrico/química , Antitrombinas/química , Celulose/química , Glicosídeos/química , Microscopia Confocal , Estrutura Molecular , Relação Estrutura-Atividade
11.
Biomater Sci ; 5(10): 1998-2008, 2017 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-28745733

RESUMO

Neutrophil extracellular trap (NET) formation, a reaction of the innate immune system to fight pathogens, was shown to be involved in thrombus formation. In the present study blood-contacting biomaterials with graded surface characteristics were investigated as a potential cause of NET formation on medical devices. Surface properties are known to govern protein adsorption, cell adhesion and ultimately the activation of several other host defense pathways - potentially also the formation of NETs. Model materials of defined hydrophilic or hydrophobic properties (glass, and thin films of poly(ethylene-alt-maleic anhydride), self-assembled monolayers of methyl terminated alkanethiols, and Teflon AF™) were incubated either with isolated human granulocytes after pre-adsorption with plasma proteins or with human whole blood. NET formation - detected as extracellular DNA, citrullinated histones, elastase and reactive oxygen species (ROS) - was observed on hydrophobic surfaces. Furthermore, NET formation on the hydrophobic surface Teflon AF™ resulted in elevated thrombin generation in hirudin-anticoagulated whole blood, but not in heparinized whole blood. Disintegration of surface-bound NETs by DNase treatment resulted in significantly lower pro-coagulant effects. Thus, NET formation can contribute to the thrombogenicity of clinically applied hydrophobic materials, suggesting NETosis as well as NET surface anchorage as new targets of anticoagulation strategies.


Assuntos
Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Armadilhas Extracelulares/efeitos dos fármacos , Armadilhas Extracelulares/metabolismo , Neutrófilos/citologia , Trombose/induzido quimicamente , Trombose/patologia , Plaquetas/efeitos dos fármacos , Plaquetas/metabolismo , Fibrinogênio/metabolismo , Humanos , Interações Hidrofóbicas e Hidrofílicas , Neutrófilos/efeitos dos fármacos , Espécies Reativas de Oxigênio/metabolismo , Propriedades de Superfície , Trombose/metabolismo
12.
ACS Appl Mater Interfaces ; 9(46): 40107-40116, 2017 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-29091393

RESUMO

Contact between biomedical materials and blood often initiates undesirable pro-coagulant and pro-inflammatory processes. On negatively charged materials, blood coagulation is known to be triggered through autoactivation of Factor XII, while activation on cationic surfaces follows a distinct and so far enigmatic mechanism. Because Factor VII activating protease (FSAP) is known to be activated on positively and on negatively charged macromolecules in plasma, we have investigated its interaction with charged biomaterials and its consequences for coagulation. Several activation processes in blood and plasma were characterized after contact with material surfaces with varied charge. FSAP was found to be exclusively activated by the positively charged surfaces polyethylenimine (PEI) and poly-l-lysine (PLL), not by the negatively charged glass or self-assembled monolayer with carboxyl group termination (SAM-COOH), as well as uncharged (Teflon AF) surfaces. Whole blood incubation on PEI showed that this activation was concomitant with coagulation as determined by thrombin and fibrin formation, which was high for glass (F1+2, 138 nM) and PEI (F1+2, 44 nM) but low for Teflon AF (F1+2, 3.3 nM) and SAM COOH (F1+2, 5.8 nM). Contact phase inhibitor diminished coagulation to background levels for all surfaces except PEI (F1+2: ^PEI 43 to 25 nM; glass, 58 to 1.5 nM) indicating that coagulation activation is not dependent on FXII activation on the PEI surface. A decisive role of endogenous FSAP for coagulation however was confirmed with the use of FSAP inhibitory antibodies which showed no influence on Teflon AF, glass and SAM COOH but diminished F1+2 on PEI to less than 50%. We propose that FSAP activation could be a novel mechanism of surface-driven coagulation. An inhibition of this protease might improve hemocompatibility of cationic surfaces and therefore facilitate the application of polycationic surfaces in blood.


Assuntos
Serina Endopeptidases/metabolismo , Coagulação Sanguínea , Fator VII , Trombina
13.
Biomaterials ; 135: 53-61, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28486148

RESUMO

Feedback-controlled anticoagulant hydrogels were formed by crosslinking the anticoagulant heparin with star-shaped poly(ethylene glycol) using peptide linkers, which are selectively cleaved by different activated blood coagulation factors acting as proteolytic enzymes. Various cleavable peptide units, differing either in their thrombin turnover rates or in their responsiveness to factors activated earlier in the course of blood coagulation, were used for the formation of the biohybrid materials. Release triggered by the early coagulation factors Xa (FXa) or FXIIa/kallikrein was shown to enhance the efficiency of the released anticoagulant. Furthermore, FXa-cleavable gels enabled a faster release of heparin, which was attributed to the lower affinity of the factor for heparin. Combining early and fast responses, FXa-cleavable gels were shown to provide anticoagulant protection of biomaterial surfaces at low levels of released heparin in human whole-blood incubation experiments. The results demonstrate the potential for employing biomolecular circuits in the design of functional biomaterials to tailor the adaptive delivery of bioactive molecules.


Assuntos
Fatores de Coagulação Sanguínea/química , Heparina/química , Hidrogéis/química , Anticoagulantes/química , Fator Xa/química , Humanos , Polietilenoglicóis/química , Trombina/química
14.
J Biomed Mater Res A ; 76(4): 681-9, 2006 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-16302224

RESUMO

Polyethersulfone foils (PES)--a unique material for blood purification membranes--were coated with a multilayer assembly of heparin (unfractionated or high anticoagulant activity fraction heparin) and albumin (albumin-heparin coatings), or with a multilayer of albumin (albumin coating), using the layer-by-layer technique. The coatings combine advantages of albumin (reduction of nonspecific interactions) and heparin (specific interactions with blood coagulation proteins). The differences between the two heparins, while significant for their biological activity, had only a minor effect on the multilayer assembly with albumin monitored in situ by reflection infrared spectroscopy (FTIR MIRS). Uncoated as well as modified PES surfaces were evaluated using an in vitro assay with freshly drawn, slightly heparinized (1.5 IU heparin/mL) human whole blood. The blood was circulated with a roller pump over the sample surfaces in shear flow across rectangular slit channels ( app. 6 mL/min and 120 s(-1)) for 1.5 h at 37 degrees C. All coatings effectively reduced platelet adhesion and activation according to the PF4 release. The activation of coagulation evaluated as TAT generation was significantly lowered for the coating composed of albumin and high activity heparin. A further beneficial effect of the heparin containing coatings was reduced complement activation as determined by different complement fragments.


Assuntos
Albuminas/química , Materiais Biocompatíveis , Heparina/química , Polímeros/química , Sulfonas/química , Coagulação Sanguínea , Plaquetas/citologia , Adesão Celular , Ativação do Complemento , Ensaio de Imunoadsorção Enzimática , Humanos , Microscopia Eletrônica de Varredura , Ativação Plaquetária , Espectroscopia de Infravermelho com Transformada de Fourier
15.
Biomaterials ; 26(33): 6547-57, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15939466

RESUMO

Self-assembled monolayers (SAMs) of alkanethiols with various terminating groups (-OH, -CH3, -COOH) and binary mixtures of these alkanethiols were studied with respect to their hemocompatibility in vitro by means of freshly taken human whole blood. The set of smooth monomolecular films with graded surface characteristics was applied to scrutinize hypotheses on the impact of surface chemical-physical properties on distinct blood activation cascades, i.e. to analyze -OH surface groups vs. complement activation, acidic surface sites vs. contact activation/coagulation and surface hydrophobicity vs. thrombogenicity. Blood and model surfaces were analyzed after incubation for the related hemocompatibility parameters. Our results show that the adhesion of leukocytes is abolished on a -CH3 surface and greatly enhanced on surfaces with -OH groups. The opposite was detected for the adhesion of platelets. A strong correlation between the activation of the complement system and the adhesion of leukocytes with the content of -OH groups could be observed. The contact activation for hydrophilic surfaces was found to scale with the amount of acidic surface sites. However, the coagulation and platelet activation did not simply correlate with any surface property and were therefore concluded to be determined by a superposition of contact activation and platelet adhesion.


Assuntos
Alcanos/química , Materiais Biocompatíveis/química , Sangue/metabolismo , Compostos de Sulfidrila/química , Propriedades de Superfície , Adsorção , Plaquetas/metabolismo , Bradicinina/química , Adesão Celular , Ativação do Complemento , Complemento C5a/química , Proteínas do Sistema Complemento , Ensaio de Imunoadsorção Enzimática , Fibrina/química , Humanos , Leucócitos/citologia , Leucócitos/metabolismo , Teste de Materiais , Microscopia Eletrônica de Varredura , Ativação Plaquetária , Adesividade Plaquetária , Fatores de Tempo
16.
J Chromatogr A ; 1005(1-2): 113-22, 2003 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-12924786

RESUMO

Biomolecular surface engineering of materials often requires precise, versatile and efficient quantification of immobilized proteins at solid surfaces. Acidic hydrolysis of surface-bound proteins and subsequent HPLC analysis of fluorescence-derivatized amino acids were adapted and critically evaluated for that purpose. Contaminations and concentration-dependent amino acid retrieval during HPLC were found to influence the accuracy of the method. In addition to the choice of adequate conditions for hydrolysis, derivatization and chromatographic separation extensions of the data evaluation were suggested to improve the accuracy of the approach when applied to single protein systems: comparing the experimentally obtained amino acid ratio to the protein constitution enabled to identify the properly separated and detected amino acids. Those amino acids were selected for a more precise calculation of the amount of immobilized protein. To further increase the accuracy of the method, the retrieval of amino acids corresponding to protein amounts in the range between 0.5 and 4.0 microg was analyzed for a variety of proteins of interest to derive protein-specific correction factors. The evaluation of amino acid data was furthermore applied to quantify binary protein mixtures at similar settings. This method was proven useful to detect the composition of protein mixtures throughout a wide range of absolute and relative concentrations.


Assuntos
Aminoácidos/análise , Proteínas/análise , Cromatografia Líquida de Alta Pressão/métodos , Corantes Fluorescentes/química , Proteínas/química , Espectrometria de Fluorescência
18.
Biomaterials ; 33(31): 7677-85, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22840226

RESUMO

Albumin-scavenging surfaces decorated with n-alkyl chains represent an established strategy for blood-contacting applications. To evaluate this concept, a set of poly (2-hydroxyethyl methacrylate) (pHEMA) films modified with different amounts of octadecyl isocyanate (C18) was investigated in an in vitro hemocompatibility assay using freshly drawn human whole blood. In addition, the hydrogel materials were thoroughly characterized with respect to changes in wettability and elasticity, which accompanied the gradual chemical modification of pHEMA. An increase of the surface C18 content induced enhanced hydrophobicity and stiffness. Immobilization of C18 chains was found to substantially reduce the coagulation activation and the complement activation by the pHEMA films. Platelet adhesion and degranulation (PF4 release) were similar on the modified and the unmodified pHEMA. Platelet adhesion to pHEMA hydrogels was lower than the polytetrafluoroethylene reference. We conclude that the immobilization of octadecyl chains improved the hemocompatibility of pHEMA materials under conditions that might be encountered in low shear blood flow.


Assuntos
Materiais Biocompatíveis/farmacologia , Poli-Hidroxietil Metacrilato/química , Poli-Hidroxietil Metacrilato/farmacologia , Antitrombinas/metabolismo , Plaquetas/citologia , Plaquetas/efeitos dos fármacos , Plaquetas/ultraestrutura , Antígeno CD11b/metabolismo , Complemento C5a/metabolismo , Granulócitos/citologia , Granulócitos/efeitos dos fármacos , Granulócitos/ultraestrutura , Humanos , Hidrogéis/química , Isocianatos/química , Fenômenos Mecânicos/efeitos dos fármacos , Microscopia de Fluorescência , Adesividade Plaquetária/efeitos dos fármacos , Contagem de Plaquetas , Fator Plaquetário 4/metabolismo , Solubilidade , Trombina/metabolismo
19.
J Biomed Mater Res A ; 94(3): 905-12, 2010 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-20730927

RESUMO

The irreversible thrombin inhibitor D-Phe-Pro-Arg-chloromethylketone (PPACK) was covalently immobilized to PEGylated polymer thin films at its primary alpha-amino group. Activity assays and capture of radioconjugated thrombin reveal that the PPACK-decorated surfaces could bind thrombin forming up to 30% of a monolayer density. Back-calculation of this high thrombin-inhibiting capacity indicated that the surface immobilization of the inhibitor was still associated with more than two orders of magnitude of loss of activity; increasing activity was observed at higher surface densities. PPACK-containing polymer films almost duplicated the plasma coagulation time when compared with the reference substrate without inhibitor. In whole blood, however, the anticoagulant properties were below those previously found for benzamidine-type reversible thrombin inhibitors; in addition, the surface exhibited inflammatory properties. It is concluded that immobilized reversible thrombin inhibitors are more effective by passivating higher amounts of thrombin in a cooperative action with antithrombin III.


Assuntos
Clorometilcetonas de Aminoácidos/química , Teste de Materiais , Inibidores de Serina Proteinase/química , Trombina/antagonistas & inibidores , Coagulação Sanguínea , Ativação do Complemento , Humanos , Proteínas Imobilizadas/química , Estrutura Molecular , Propriedades de Superfície
20.
Biomaterials ; 31(9): 2498-507, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20035991

RESUMO

Biomaterial-induced thrombosis is usually attributed to blood coagulation initiated by contact phase and platelet-related reactions. Considering the major role of extrinsic initiation in blood coagulation in vivo, we studied the material related-induction of this pathway by investigating the relevance of surface properties for the expression of Tissue Factor (TF), a critical initiator of the extrinsic pathway of coagulation. We incubated materials with self-assembled monolayers of alkylthiols (SAMs) displaying various ratios of -CH(3), -OH, and -COOH terminations with fresh heparinized whole human blood in vitro. The transcription of TF-mRNA in leukocytes showed clear differences in relation to surface properties and increased over time. In addition, a positive correlation between TF transcription and its presence on leukocytes, granulocyte activation, and complement activation was found. Cells displaying the highest TF expression after material contact had significantly lower intracellular TF, pointing to previous TF release. Yet under the conditions of our whole blood incubation set-up within the limited time frame the observed initiation of the extrinsic pathway did not trigger blood coagulation.


Assuntos
Materiais Biocompatíveis/farmacologia , Leucócitos/efeitos dos fármacos , Leucócitos/metabolismo , Teste de Materiais , Tromboplastina/metabolismo , Antitrombinas/metabolismo , Bioensaio , Adesão Celular/efeitos dos fármacos , Ativação do Complemento/efeitos dos fármacos , Complemento C3/imunologia , Fator XIIa/metabolismo , Citometria de Fluxo , Humanos , Calicreínas/sangue , Leucócitos/citologia , Adesividade Plaquetária/efeitos dos fármacos , Propriedades de Superfície/efeitos dos fármacos , Trombina/metabolismo , Tromboplastina/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA