Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
3.
Crit Care Resusc ; 26(2): 71-79, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39072236

RESUMO

Introduction: Monitoring healthcare quality is challenging in paediatric critical care due to measure variability, data collection burden, and uncertainty regarding consumer and clinician priorities. Objective: We sought to establish a core quality measure set that (i) is meaningful to consumers and clinicians and (ii) promotes alignment of measure use and collection across paediatric critical care. Design: We conducted a multi-stakeholder Delphi study with embedded consumer prioritisation survey. The Delphi involved two surveys, followed by a consensus meeting. Triangulation methods were used to integrate survey findings prior tobefore the consensus meeting. In the consensus panel, broad agreement was reached on a core measure set, and recommendations were made for future measurement directions in paediatric critical care. Setting and participants: Australian and New Zealand paediatric critical care survivors (aged >18 years) and families were invited to rank measure priorities in an online survey distributed via social media and consumer groups. A concurrent Delphi study was undertaken with paediatric critical care clinicians, policy makers, and a consumer representative. Interventions: None. Main outcome measures: Priorities for quality measures. Results: Respondents to the consumer survey (n = 117) identified (i) nurse-patient ratios; (ii) visible patient goals; and (iii) long-term follow-up as their quality measure priorities. In the Delphi process, clinicians (Round 1 n = 191; Round 2 n = 117 [61% retention]; Round 3 n = 14) and a consumer representative reached broad agreement on a 51-item (61% of 83 initial measures) core measure set. Clinician priorities were (i) nurse-patient ratio; (ii) staff turnover; and (iii) long term-follow up. Measure feasibility was rated low due to a perceived lack of standardised case definitions or data collection burden. Five recommendations were generated. Conclusions: We defined a 51-item core measurement set for paediatric critical care, aligned with clinician and consumer priorities. Next steps are implementation and methodological evaluation in quality programs, and where appropriate, retirement of redundant measures.

4.
EClinicalMedicine ; 44: 101259, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35059614

RESUMO

BACKGROUND: Health care-associated infections (HCAI) in neonatal units in low- and middle-income countries (LMIC) are a major cause of mortality. This scoping review aimed to synthesise published literature on infection prevention and care bundles addressing neonatal HCAI in LMICs and to construct a Classification Framework for their components (elements). METHODS: Five electronic databases were searched between January 2001 and July 2020. A mixed-methods approach was applied: qualitative content analysis was used to build a classification framework to categorise bundle elements and the contents of the classification groups were then described quantitatively. FINDINGS: 3619 records were screened, with 44 eligible studies identified. The bundle element Classification Framework created involved: (1) Primary prevention, (2) Detection, (3) Case management, and Implementation (3 + I). The 44 studies included 56 care bundles with 295 elements that were then classified. Primary prevention elements (128, 43%) predominated of which 71 (55%) focused on central line catheters and mechanical ventilators. Only 12 elements (4%) were related to detection. A further 75 (25%) elements addressed case management and 66 (88%) of these aimed at outbreak control. INTERPRETATION: The 3 + I Classification Framework was a feasible approach to reporting and synthesising research for infection-relevant bundled interventions in neonatal units. A shift towards the use in infection prevention and care bundles of primary prevention elements focused on the neonate and on commonly used hospital devices in LMIC (e.g., self-inflating bags, suctioning equipment) would be valuable to reduce HCAI transmission. Detection elements were a major gap. FUNDING: This work was made possible in part by the John D. and Catherine T. MacArthur Foundation, the Bill & Melinda Gates Foundation, ELMA Philanthropies, The Children's Investment Fund Foundation UK, The Lemelson Foundation, and the Ting Tsung and Wei Fong Chao Foundation under agreements to William Marsh Rice University. The project leading to these results has also received the support of a fellowship from the "la Caixa" Foundation (ID 100010434). The fellowship code is LCF/BQ/EU19/11710040. EJAF is an Academic Clinical Fellow whose salary is funded by the UK National Institute for Health Research (NIHR). NES receives a Research Training Program Scholarship (Australian Commonwealth Government).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA