Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Folia Microbiol (Praha) ; 38(2): 150-2, 1993.
Artigo em Inglês | MEDLINE | ID: mdl-8375781

RESUMO

No changes in immunoglobulin (IgG, IgM and IgA) and complement components C3 and C4 levels could be observed in patients suffering from both recurrent and acute nasal polyposis. However, in both groups of patients a significant decrease of the alternative pathway of complement activation (up to 80%) was found. In addition, patients suffering from the acute disease showed even decreased classical complement pathway (up to 20%). Examination of complement activation pathways was shown to be advantageous for the follow-up of the course of this disease.


Assuntos
Complemento C3/análise , Complemento C4/análise , Via Alternativa do Complemento , Pólipos Nasais/imunologia , Doença Aguda , Adulto , Idoso , Feminino , Seguimentos , Humanos , Imunoglobulinas/biossíntese , Masculino , Pessoa de Meia-Idade , Pólipos Nasais/sangue , Recidiva
2.
Acta Chir Orthop Traumatol Cech ; 62(1): 47-52, 1995.
Artigo em Cs | MEDLINE | ID: mdl-20470486

RESUMO

In 1987-1992 at the Orthopaedic Clinic of the IPVZ 61 non-cemented total endoprostheses of the hip joint Walter-Motorlet were implanted. The mean age of the patients is 50 years, the most frequent cause of operation is secondary postdysplastic arthritis of the hip joint (42.6%). In 1994 the authors evaluated the results, using Harris' method. The shortest follow up period is 12 months, the mean follow up period 29 months. In the subjective evaluation 23% of the patients report pain of the operated joint dependent on analgetics. In the general evaluation excellent or good results were recorded in 68.2%, satisfactory results in 20.5%, poor results in 11.3% of the patients. Roentgenological loosening of the socket was observed in three patients, the socket was, however, not reimplanted so far. Five patients were reoperated on account of aseptic loosening of the shank; reimplantation of a cemented shank Poldi was performed. In another three patients there are certain X-ray signs of loosening. So far failure of the femoral component occurred so far in eight patients. As compared with the hybrid combination Walter-Motorlet socket/Poldi shank the results are from the aspect of subjective evaluation by the patients as well as with regard to the number of aseptic loosenings worse when non-cemented prostheses are used. Key words: non-cemented endoprosthesis of the hip joint, aseptic loosening, reoperation of TEP of the hip joint.

3.
Artigo em Cs | MEDLINE | ID: mdl-20470491

RESUMO

In 1987-1992 at the Orthopaedic Clinic IPVZ 108 hybrid endoprostheses of the hip joint, type Walter-Motorlet/Poldi were implanted (non-cemented socket Walter-Motorlet, cemented shank Poldi). The authors submit evaluations of 75 endoprotheses made 2-7 years after surgery (mean follow-up period 3 and a half years). The mean age of the patients was 49 years (range 39-62 years), the most frequent preoperative diagnosis was secondary postdysplastic coxarthrosis (52%), other diagnoses were primary coxarthrosis (24%), idiopathic necrosis of the head of the femur (20%) and posttraumatic coxarthrosis (4%). Genneral evaluation according to Harris revealed excellent results in 6% of the patients and unsatisfactory results in 1% of the patients. Subjective evaluation of the painfulness revealed a painless hip joint in 56%, mild occasional pain was reported by 30% of the patients and mild pain which can be mitigated by aspirin was recorded in 14% of the patients. The prosthesis became loosened in one patient bilaterally - it was a case of poor indication of a total endoprosthesis of the hip joint in a patient with a metabolic disorder and osteopathy. The general incidence of paraarticular ossifications was 17%. Comparison of the results with a similar group of patients with non-cemented total endoprostheses Walter-Motorlet, the results obtained with hybrid total endoprostheses are better from the subjective and objective aspect. Key words: hybrid total endoprosthesis of the hip joint, aseptic loosening.

4.
Acta Chir Orthop Traumatol Cech ; 62(2): 106-10, 1995.
Artigo em Cs | MEDLINE | ID: mdl-20470493

RESUMO

A non-cemented endoprosthesis of the hip joint ABG is producet by Howmedica Co. from a titanium alloy. The socket is hemispherical, primarily anchored according to the press fit principle. The external surface of the annulus is covered by a layer of hydroxyapatite. The shape of the shank is anatomical, it respects the anterior curvature of the femur and the anteversion of the neck of the femur. Its primary stability is ensured by the shape of the shank, the secondary stability is achieved in the process of osteoinduction in the metaphyseal part covered by hydroxyapatite. Between 1992 and 1994 18 hip joints were operated. No peroperative nor postoperative complications were observed, the short-term results are very good. With regard to the short follow-up time, long-term clinical results will be the subject of subsequent papers. Key words: non-cemented endoprosthesis of the hip joint, press fit principle, hydroxyapatite, osteoinduction.

5.
Acta Chir Orthop Traumatol Cech ; 60(6): 340-3, 1993.
Artigo em Cs | MEDLINE | ID: mdl-8128810

RESUMO

The authors present an account of their initial experience with Wagner's non-cemented femoral revision prosthesis of the hip joint. After a brief technical description of the implant the mention the indications and contraindications of they revision shaft. They emphasize the necessity of peroperative planning and describe the surgical technique. Since 1992 they used a revision shaft in five patients (three times in aseptic loosening of a TEP of the hip joint, once during septic loosening and once when treating a periprosthetic fracture with extensive bone destruction). Long-term experience will be the subject of a subsequent paper.


Assuntos
Cimentação , Prótese de Quadril , Fraturas do Quadril/patologia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/patologia , Humanos , Falha de Prótese , Infecções Relacionadas à Prótese/patologia , Infecções Relacionadas à Prótese/cirurgia , Radiografia , Reoperação
6.
Acta Chir Orthop Traumatol Cech ; 60(3): 158-62, 1993.
Artigo em Cs | MEDLINE | ID: mdl-8346687

RESUMO

At the Orthopaedic Clinic of the Institute for Postgraduate Medical Training in the course of 10 years (1979-1989) 2340 primary implantations of total endoprostheses of the hip joint were performed. During the same period 168 total endoprostheses of the hip joint and 20 cervico-occipital prostheses were reoperated. The most frequent reason for reoperation was aseptic loosening of the acetabular component. The mean period between operation and reoperation in these patients was 98 months. In the group with loosening of the socket associated with mechanical destruction of the component the mean period which had elapsed since the primary operation was 43 months. In 87% small size sockets were involved. The most serious problem of reoperation of total endoprostheses of the hip joint is replacement of bone defects. During reoperation of acetabular components an isolated defect on the floor of the acetabulum was found in 26%, a defect of the margins in 38% and a combined defect of the margins in 26% of the patients. For treatment of the defects the authors used bone grafts in the majority allogenic grafts were involved which were used to reconstruct the margins and floor of the acetabulum. Metal implants should hold the bone grafts in the desired position and should not serve as a skeleton. Reoperation of the acetabular part of total endoprostheses of the hip joint is easier from the technical aspect; in defects of the upper portion of the femur it is essential to use a very careful procedure and to preserve the skeleton to a maximal extent.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Prótese de Quadril , Feminino , Articulação do Quadril/cirurgia , Humanos , Masculino , Métodos , Falha de Prótese , Reoperação
7.
Acta Chir Orthop Traumatol Cech ; 60(5): 284-6, 1993.
Artigo em Cs | MEDLINE | ID: mdl-8285006

RESUMO

In 1986-1988 at the Orthopaedic clinic of the Institute for Postgraduate Medical Training 56 stems on non-cemented total endoprostheses of the hip joint type Schenker were implanted. The non-cemented stem was combined in all patients with a cemented socket Poldi. The endoprosthesis was indicated in particular in young patients in 59% in hip joints affected with secondary postdysplastic arthritis of the hip joint. The group was checked by Harris' method, the mean follow-up period in 1992 was 58 months. Of 36 followed up patients 21 operated patients reported pain in the area of the hip joint, 10 patients used analgetics. In nine patients reimplantation of the non-cemented Schenker stem was performed on account of aseptic loosening, in 11 patients the X-ray check revealed obvious signs of aspectic loosening associated with subjective complaints. The dependence of aseptic loosening on the quality of primary implantation is marked. In patients with perfect cortical contact of the stem aseptic loosening developed in 27% of the patients, in patients with inadequate cortical contact aseptic loosening was recorded in 80% of the operated patients. The general evaluation according to Harris comprised 42% excellent results, 30% good results, 14% satisfactory results and 14% poor results. This evaluation does not include patients who on account of pain and loosening of the femoral Schenker component were already re-operated. Because of the considerable number of complications implantation of this type of prosthesis was discontinued at the authors' department.


Assuntos
Cimentação , Prótese de Quadril , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Falha de Prótese
8.
Acta Chir Orthop Traumatol Cech ; 63(3): 158-61, 1996.
Artigo em Cs | MEDLINE | ID: mdl-20470557

RESUMO

The authors implanted in 1985-1992 25 hinged endoprostheses of the knee joint, type Endomodell Link. It is a type of endoprosthesis which belongs into the group of so-called modified hinged prostheses. In addition to flexion and extension the design of the implant permits also 15 degree axial rotation. Indication for operation were deformities of the knee joint in 21 cases, re-operation in two knee joints and bony ankylosis associated with rheumatoid arthritis in two knee joints. The mean age of the patients was 64 years. In two patients infectious complications developed and the implant had to be removed. The authors did not record in any of the patients aseptic loosening with migration of the components or formation of radiolucencies. In one female patient the movable portion of the endoprosthesis broke of and after reimplantation of the damaged part 1.5 years later mechanical failure occurred due to wear of the thin-walled polyethylene capsule which caused laxity of the joint in the varus - valgus sense. During clinical check-up of the patients the authors found a similar condition - laxity of the knee joint in another 10 patients. It may be assumed that in these patients mechanical failure and the necessity of re-operation is only a question of time. Based on this experience the authors ceased to use this type of endoprosthesis. Key words: hinged prosthesis of the knee joint, mechanical failure.

9.
Acta Chir Orthop Traumatol Cech ; 64(5): 282-91, 1997.
Artigo em Cs | MEDLINE | ID: mdl-20470634

RESUMO

The authors evaluate a group of 192 patients operated in 1983 at the Orthopaedic Clinic of the Institute for Postgraduate Medical Training to whom 196 cemented total endoprostheses of the hip joint type Poldi were implanted. Of these 53.1 % patients were operated on account of primary arthritis, 29.1 % on account of postdysplastic arthritis of the hip joint. In four patients conversion of an osseous ankylosis to an endoprosthesis was performed. In 59.7 % a medium Poldi socket was used, in 36.5 % a small Poldi socket and in 13.8 % a large Poldi socket. For fixation in all patients Palacos cement with first generation technique was used. In seven patients augmentation of a dysplastic acetabulum by an autogenous graft, as described by Harris, was made. The number of peroperative complications and technical errors does not exceed data in the literature. 15.8 % hip joints were re-operated - 0.5 % on account of a relapsing dislocation, 0.5 % because of early failure of the cement-bone bond due to bad cementing technique of the acetabular component, 1 % on account of late septic release, 0.5 % because of isolated aseptic release of the shank, 2.6 % because of aseptic release of both components and 10.7 % on account of aseptic release of the acetabular component, on average 8.3 years after surgery. Aseptic release of the socket correlates significantly with the size of the socket used and with the original diagnosis. The mean wear of the small socket is 0.22 mm per year, of the medium socket 0.28 mm per year and of the large socket 0.12 mm per year. Sockets of small size become released four times as frequently as medium and large ones and release is twice as frequent after surgery of secondary postdysplastic arhritis than after implantation on account of deforming arthritis of the hip joint. When evaluating the group of 60 hip joints according to HHS in 31.7 % excellent results were achieved, in 28.3 % good results, in 20 % satisfactory results and in 20 % poor results. The authors did not find a positive correlation between painfulness of the joint and signs of aseptic release of the socket on X-ray examination. Key words: TEP of the hip joint, aseptic release, bone cement, complications of TEP of the hip joint.

10.
Acta Chir Orthop Traumatol Cech ; 64(6): 342-6, 1997.
Artigo em Cs | MEDLINE | ID: mdl-20470641

RESUMO

In 1987-1994 at the Orthopaedic Clinic of the Institute for Postgraduate Medical Training 67 non-cemented total endoprostheses of the hip joint, type Walter-Motorlet were implanted. The authors submit the evaluation of 39 endoprostheses 30-102 months after operation (mean follow-up period 62.5 months). The investigation comprised 14 patients where by March 1997 reimplantation of one or both components was performed. The mean age of the patients at the time of operation was 49 years. Secondary postdysplastic arthritis was the indication in 53.9 %, primary arthritis in 23.1 %, necrosis of the neck of the femur in 10.3 %. In the general evaluation according to Harris excellent results were achieved in 43.6 %, good results in 25.7 %, satisfactory results in 17.8 % and unsatisfactory results in 12.9 %. As to subjective evaluation, a painless hip joint was reported only by 25.6 % of the patients, slight pain not restricting activity was reported by 41 %, pain which had to be mitigated by analgesics by 33.4 %. Certain X-ray signs of loosening were found in the area of the acetabular component in three patients, in the area of the femoral component in four patients. As compared with the hybrid combination Walter-Motorlet socket/Poldi shaft and as compared with evaluation of the Zweymüller endoprosthesis the results are worse as regards the number of aseptic loosenings and subjective evaluation by the patients. Key words: non-cemented endoprosthesis of the hip joint, aseptic loosening, reoperation of TEP of the hip joint.

11.
Acta Chir Orthop Traumatol Cech ; 66(1): 37-40, 1999.
Artigo em Cs | MEDLINE | ID: mdl-20478131

RESUMO

Twenty-nine unicondylar replacements of the knee joint (UKR) of St. Georg type were implanted in 27 patients at the Orthopaedic Clinic IPVZ in the period between 1985-1994. The average age in case of females was 73 years, in case of men 71 years. The most frequent indication was osteoarthritis of the knee joint of varus type. Two patients (7 %) had to be reoperated on for aseptic loosening of the tibial component, on average 5,5 years after the surgery. Revision surgery for breaking of femoral component was performed in five cases, on average 6 years after the primary implantation. The authores evaluated 16 patients with UKR still in situ. In 8 patients the prosthesis is entirely painless, in 10 joints operated on the radiograph showed a developed femoropatelar osteoarthritis, osteoarthritic changes of the opposite compartment in 2 of them and a radioluscent line up to 1 mm in 3 cases. Despite a high frequency of late complications the authors consider UKR for an alternative to high supratubercular osteotomy of tibia in older patients, for a suitable method of the treatment of osteochondritis dissecans and Ahlbäck disease of the knee joint. The success of this operation is conditioned by a perfect surgical technique and implant of suitable design. Key words: replacement of the knee joint, aseptic loosening, fatique failure of material.

12.
Acta Chir Orthop Traumatol Cech ; 66(3): 181-6, 1999.
Artigo em Cs | MEDLINE | ID: mdl-20478149

RESUMO

The authors present medium-term clinical results and radiographic evaluation of the implantation of cementless ABG total hip replacement. The implant is made from titanium alloy with a press-fit acetabular cup. The outer surface of the cup is coated with hydroxyapatite. Primary stability of the stem is guaranteed by its anatomical shape, secondary stability by the hydroxyapatite coating in the metaphyseal part of the implant. Evaluation covers a group of 19 patients who showed up to the clinical and radiographic follow-up. Average age at the time of implantation was 52 years (ranging between 31 and 65). The most frequent indication was in 11 cases primary coxarthrosis, in 5 cases necrosis of the head of the hip joint. Four times the operation was indicated for secondary postdysplastic osteoarthritis of the hip joint. Clinical results were evaluated according to Harris questionnaire. Excellent result was achieved in 10 patients (50 %), good result in 6 patients (30 %). Radiographic finding was evaluated on the basis of Gruen criteria using radiographs in 2 projections. The most frequent finding was a good secondary stability of the cup and metaphyseal stem with cortex hypotrophy in zones 2 and 6. In one case we encountered certain signs of loosening of acetabular cup. One THR was re-implanted due to aseptic loosening. Average period of follow-up was 4 years and 6 months. Key words: cementless THR, hydroxyapatite, pressfit principle.

13.
Acta Chir Orthop Traumatol Cech ; 66(5): 286-9, 1999.
Artigo em Cs | MEDLINE | ID: mdl-20478166

RESUMO

Authors report on a group of patients operated on in the period 1992-1994. In large bone defects of proximal femur a cementless revision stem of type Wagner was used. The group comprised 13 patients, the most frequent indication was septic loosening of THR handled by a two-phase procedure and aseptic loosening of both components using implants 265 and 306 mm long and with a diameter 14-22 mm. In 12 patients also the cup was revised. Nine patients were checked in 1999 by Harris Hip Score with one excellent result, two good results, three fair and three poor results. Radiograph proved bone ingrowth in all patients as well as secondary biological stabilization of the stem. No signs of stem loosening were found. In 7 patients the stem subsided by maximum 12 mm. The revision of the cementless stem can be considered in certain indications for an alternative of a mere extraction of the implant, i. e. resection arthroplasty with all functional consequences. Therefore the revision stem of type Wagner is still indicated in specific cases. Key words: THR, defects of femur, revision implant.

14.
Acta Chir Orthop Traumatol Cech ; 57(4): 328-38, 1990 Jul.
Artigo em Cs | MEDLINE | ID: mdl-2239045

RESUMO

In the years 1978-1986 the authors implanted 207 total prostheses in patients with the fracture of the femoral neck or after the fractures in the area of the hip joint. 50 patients were operated on for an acute fracture of the neck. The surgical technique in these indications does not differ on principle from the surgical technique of coxarthrosis. They point out a higher number of some peroperative complications. They checked 141 patients with and average follow-up of 47 months. In 4.2 per cent of late complications they reported roentgenological symptoms of loosening. Reoperation because of the loosening of the acetabular component was inevitable in 2.9 per cent of patients. All these cases fall into the group of patients in which the total hip arthroplasty was performed after the fractures of the acetabulum. In no patient it was necessary to reoperate the femoral component. Within the check up the patients underwent roentgenological examination and the result was assessed by the method according to Harris. In total, excellent result was reported in 43.2 per cent of patients, good result in 29.8 per cent, fair result in 14.2 per cent and poor result in 12.8 per cent of patients. With regard to a low number of complications and very good results of the evaluation according to Harris the authors consider total hip arthroplasty in the treatment of post-traumatic conditions for fully indicated. Total hip arthroplasty is indicated also in acute fractures of the femoral neck in which it brings in a short time interval good functional results with minimum complications. A group at risk is represented by patients operated on after the fractures of acetabulum.


Assuntos
Fraturas do Colo Femoral/cirurgia , Fraturas do Quadril/cirurgia , Prótese de Quadril , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias
15.
Acta Chir Orthop Traumatol Cech ; 57(2): 161-7, 1990 Apr.
Artigo em Cs | MEDLINE | ID: mdl-2356687

RESUMO

The authors describe the results of the juvenile bone cyst in the group of 41 patients by the method of the application of corticoids and compare them with the results of the therapy by means of excochleation and filling the cavity of the cyst with bone grafts. In the therapy by corticoids restitutio ad integrum was achieved in 37.8 per cent and in 43.2 per cent of patients the healing was incomplete. In 5.5 per cent of cases there occurred recurrence after the cyst was healed, in 13.5 per cent there was no response to the application of corticoids. In the groups of surgically treated patients the cyst was healed in 68.8 per cent, out of which 48 per cent was restitutio ad integrum. The number of recurrence was relatively high--31.2 per cent. Both methods have their place in the therapy of bone cysts. The surgical approach makes it possible to achieve more quickly restitutio ad integrum in extensive bone cysts located at lower extremities. For the cysts affecting the humerus the method of choice is the local application of corticoids. In the therapy by steroids the authors the necessity of regular control and in case of the survival of the cyst the necessity of repeating the instillation of the steroid.


Assuntos
Cistos Ósseos/cirurgia , Glucocorticoides/administração & dosagem , Adolescente , Cistos Ósseos/tratamento farmacológico , Criança , Pré-Escolar , Feminino , Humanos , Injeções Intralesionais , Masculino
16.
Acta Chir Orthop Traumatol Cech ; 71(5): 303-7, 2004.
Artigo em Cs | MEDLINE | ID: mdl-15600127

RESUMO

In December 1997 a 48 year-old man was treated by resection of the bilateral paraarticular ankylosing ossifications that developed after 6 weeks of unconsciousness after necrotic pancreatitis. The ossifications on the posterior part of the hip joint involved a highly separated sciatic nerve. There was a bilateral osseous ankylosis of the hip joint and total denervation of sciatic nerve. In April 1999 the ossifications on the right side were removed. The splitted sciatic nerve was in two osseous channels. The head of the femur was vital and immediately following the operation, flexion of the hip joint was possible to 90 degrees. The same procedure was performed on the left hip joint in October 1999. In April 2000, a re-occurance of the paraarticular ossification on the ventral part of the right hip joint was removed from an ilioinquinal approach. In June 2002 the patient was able to stand and walk without crutches. ROM of the knee joints improved bilaterally to 120 degrees of flexion. The flexion of the right hip joint is 70 degrees and in the left hip is 80 degrees. 3 years after decompression of both sciatic nerves involved in heterotopic bone established significant reinervation. The motor function of the proximal femoral muscles and the function of the tibial nerve was renewed. Complete motor denervation syndrom persists in common peroneal nerve. Sensitive inervation was renewed as in n. tibialis as in common peroneal nerve except acral parts of the foot a toes. Concerning function of the sciatic nerves, the overall results can be assessed as partially succesfull because of partial denervation syndrome of sciatic nerves. In definite clinical improvement the recovery of the neurologic status is very important besides the mechanical improvement of range of motion of the hip joint.


Assuntos
Anquilose/cirurgia , Síndromes de Compressão Nervosa/cirurgia , Ossificação Heterotópica/cirurgia , Neuropatia Ciática/cirurgia , Anquilose/complicações , Coma/complicações , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Síndromes de Compressão Nervosa/complicações , Ossificação Heterotópica/complicações , Radiografia , Recuperação de Função Fisiológica , Neuropatia Ciática/complicações
17.
Acta Chir Orthop Traumatol Cech ; 57(1): 40-7, 1990 Feb.
Artigo em Cs | MEDLINE | ID: mdl-2336907

RESUMO

The authors have made electromyographic examination of m. tensor fasciae latae and m. glutaeus medius and sometimes also minimus in patients after the implantation of total endoprosthesis of the hip joint by anterolateral Watson - Jones approach and transgluteal Bauer approach with the aim to find out if there occurs the anticipated transection of n. glutaeus usp. and dennervation of m. tensor fasciae latae and compare from this viewpoint both approaches. The examination was performed in 18 patients after the implantation of 20 total endoprostheses of the hip joint (out of which 10 hip joints were operated on by Watson - Jones approach and 10 by Bauer approach) in the period of 6-20 weeks after operation. In the examination concentric needle electrodes and NEUROMATIC 2000 C device (produced by DANTEC Co.) were applied. It was found out that the transection of n. glutaeus sup. is inevitable in neither approach. In patients operated on by Watson-Jones approach there occurred only twice complete transection of the nerve with the dennervation of m. tensor fasciae latae, six time incomplete interruption of the nerve and twice the finding in m. tensor fasciae latae was normal. In patients operated on by Bauer approach complete transection of n. glutaeus sup. was found out six times and incomplete interruption of this nerve four times. Thus from this viewpoint Watson-Jones approach is more considerate. Moreover, in Bauer approach eight times there occurred partial interruption of the innervation of the ventral portion of m. glutaeus medius. Consequently, the study has not proved the assumption that both approaches must necessarily result in complete transection of n. glutaeus sup.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Articulação do Quadril/cirurgia , Prótese de Quadril , Músculos/fisiopatologia , Idoso , Nádegas , Eletromiografia , Feminino , Humanos , Masculino , Métodos , Pessoa de Meia-Idade
18.
Acta Chir Orthop Traumatol Cech ; 67(2): 88-92, 2000.
Artigo em Cs | MEDLINE | ID: mdl-20478189

RESUMO

The authors retrospectively evaluate a group of 28 hip joints in which in 1995 and 1996 total hip replacement was performed for developmental dysplasia of the hip joint. They included in the study only patients with dysplasia of types B, C and D after Eftekhar. By means of the method after Ranawat and Pagnan they determine the ideal centre of the rotation of the hip join and the so called TAR-true acetabular region. They checked the patients in 1999 and evaluated subjective complaints, objective findings according to Harris Hip Score and x-ray findings on a radiograph of the pelvis and on the radiograph showing a 45 degrees rotation (the Judet view). In most hip joints operated on the actual centre of rotation differed from the ideal centre of rotation. Maximum difference was 18 mm. In the hip joints of type C they recorded more often a higher position of the centre of rotation (a higher placement of the cup). None of the patients was reoperated, radiographs did not show signs of aseptic loosening of the acetabular component. Zweymüller's Bicon Plus cup can be used also in cases of severe dysplasia of the hip joint. Primary stability of the implant and a good medium-term result can be achieved in most cases. The authors consider this type of implant especially suitable for patients with developmental dysplasia. Key words: total hip replacement, developmental dysplasia of the hip, Zweymuller's Bicon cup.

19.
Acta Chir Orthop Traumatol Cech ; 69(2): 79-84, 2002.
Artigo em Cs | MEDLINE | ID: mdl-12073646

RESUMO

PURPOSE: Weil technique of the distal shortening osteotomy of metatarsal is a relatively new method of the surgical treatment of metatarsalgia and dislocation of metatarsophalangeal (MTP) joints. A retrospective study evaluates the first experience in Weil osteotomy at the authors' department. MATERIAL: Between May 1999 and the end of 2000 twelve patients (14 feet) were operated on in which the Weil technique of the osteotomy was performed on 28 metatarsals. Indication for the surgery was chronic metatarsalgia with dislocation of the MTP joint, with excessive length of one or more lesser metatarsals, with insufficiency of the first ray after the surgery of hallux valgus and metatarsalgia after the resection of the head of II metatarsal. All patients were women, average age of 57 years (range, 50-68 years) at the time of operation. The average follow-up is 9 months (range, 6-24 months). Dislocated prior to operation were 9 MTP joints, in 2 cases a deformity of 2nd digit of the digitus supraductus type was operated on. METHODS: The patients evaluated subjectively the functional and cosmetic outcomes of the surgery. Clinical evaluation related to recurrence or transfer of difficulties to the head of the neighbouring metatarsal, range of motion of the MTP joint, function and grip of the digit. Radiograph was used for the evaluation of the metatarsal index, post-operative shortening of II metatarsal, reduction of dislocation in the MTP joint and healing of osteotomy. RESULTS: Satisfied with the functionla and cosmetic results of the operation were 83% patients (10 of 12). Recurrence of metatarsalgia was not found in any patient, transfermetatarsalgia in one patient. Reduction of the range of motion in the MTP joint (plantar flexion) by more than 50% was recorded in 43% operated on metatarsals and in all metatarsals after the reduction of the dislocation. Acceptable function and strength of the digit evaluated by the ability to press by the digit a sheet of paper against the floor was preserved in most of the operated on metatarsals--86% (24 of 28). Average shortening of II metatarsal was 5.6 mm. All dislocated MTP joints were reduced postoperatively. Dislocation recurred in 2 cases. Avascular necrosis of the head of II metatarsal after the reduction of the dislocation was encountered in one case. DISCUSSION: The small number of recurrences and transfermetatarsalgia proves that Weil osteotomy allowing a controlled shortening of metatarsal with a fixation is a reliable method in the solution of metatarsalgia. The operation directly on the joint allows reduction of the dislocation of the MTP joint. Shortening of metatarsal facilitates reduction and reduces axial pressure in the MTP joint. Recurrence of dislocation is reported between 15% and 22%. After a more difficult reduction and danger of redislocation some authors recommend a temporary transfixation of the MTP joint by K-wire. The disadvantage of the operation is a frequent temporary limitation of the range of motion in the MTP joint which is caused by the opening of the articular capsule and its subsequent contraction. No author reports any problems with the healing of the osteotomy. The results in our group of patients are comparable with the results published by other authors. CONCLUSION: Weil osteotomy allows a planned controlled shortening of metatarsal with a stable fixation. Osteotomy heals well. Osteotomy is intraarticular which on one side provides the possibility to correct dislocation in the MTP joint, however, on the other hand it poses a risk of the limitation of the range of motion of this joint. The main contribution the authors see in the new possibility of surgical treatment of more severe matatarsalgia and deformities of the forefoot with the preservation of joints.


Assuntos
Deformidades Adquiridas do Pé/cirurgia , Luxações Articulares/cirurgia , Ossos do Metatarso/cirurgia , Articulação Metatarsofalângica/cirurgia , Osteotomia/métodos , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Dor/etiologia
20.
Acta Chir Orthop Traumatol Cech ; 68(1): 18-23, 2001.
Artigo em Cs | MEDLINE | ID: mdl-11706710

RESUMO

PURPOSE OF THE STUDY: The aim of the work is to evaluate the results of revision surgeries of total hip replacements at the Orthopaedic Department IPVZ in 1999. MATERIAL: Revision surgery of 61 THR was performed at the Orthopaedic Department IPVZ in 1999. Most of them (54) were reoperated for aseptic loosening of the cup or both components, 4 patients for aseptic loosening of the stem, 1 patient was reoperated for recurring dislocation of THR and 2 patients for septic loosening. Eleven loosened 44/32 Poldi cups were reoperated on average after 160 months, twelv 49/32 Poldi cups on average after 143 months and seven 54/32 Poldi cups on average after 111 months. Sixteen loosened Walter Motorlet cups were reoperated on average after 111 months, 16 loosened Walter-Motorlet cups were revised on average after 83 months, 3 Martin cups on average after 112 months. Another 4 cementless cups of different provenance were reoperated in the interval of 9-54 months after the primary operation. METHODS: For the revision surgery we used 28 times Zweymüller Bicon cementless cup and in 26 hip joints Poldi cemented cup, in 6 patients we applied structural bone allografts, in 31 patients morselized allografts prepared on a bone mill. For the revision surgery of loosened stems we used in 18 patients Zweymüller SL Plus stem and in 7 patients Zweymüller SLR stem. DISCUSSION: From the viewpoint of long-term results THR implanted in patients with a secondary postdysplastic osteoarthritis is more risky than in the patients with a primary degenerative affection of the joint. It has been proved that also a cemented total hip replacement may bring good long-term results comparable with the results of some cementless implants. CONCLUSION: In most of the patients the primary diagnosis was postdysplastic osteoarthritis of the hip joint. Recently the need has started to grow for revision surgery in patients with loosened modern cementless implants. In revision surgeries the system of cementless THR of Zweymüller type proved suitable. The need for the application of bone allografts was quite frequent.


Assuntos
Artroplastia de Quadril , Idoso , Feminino , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Reoperação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA