Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 164
Filtrar
1.
Pharm Dev Technol ; 27(1): 9-18, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34895036

RESUMO

The poor aqueous solubility of irbesartan (IRB) and candesartan cilexetil (CAC) may hamper their bioavailability when orally or topically administered. Among several attempts, the promising nanoaggregate formation by γ-cyclodextrin (γCD) complexation of drugs in aqueous solution with or without water-soluble polymers was investigated. According to phase solubility studies, Soluplus® showed the highest complexation efficiency (CE) of drug/γCD complexes among the polymers tested. The aqueous solubility of IRB and CAC was markedly increased as a function of Soluplus® concentrations. The binary drug/γCD and ternary drug/γCD/Soluplus® complex formations were supported and confirmed by solid-state characterizations, including differential scanning calorimetry (DSC), powder X-ray diffraction (PXRD), and Fourier transform infrared (FT-IR) spectroscopy. The true inclusion mode was also proved by proton nuclear magnetic resonance (1H-NMR) spectroscopy. The nanoaggregate size and morphology of binary and ternary systems were observed using dynamic light scattering (DLS), and transmission electron microscopy (TEM) techniques. The size of these nanocarriers depends on the concentration of Soluplus®. The use of Soluplus® could significantly enhance drug solubility and stabilize complex nanoaggregates, which could be a prospective platform for drug delivery systems.


Assuntos
gama-Ciclodextrinas , Benzimidazóis , Compostos de Bifenilo , Varredura Diferencial de Calorimetria , Irbesartana , Polietilenoglicóis , Polivinil , Solubilidade , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Tetrazóis , Difração de Raios X , gama-Ciclodextrinas/química
2.
Retina ; 40(11): 2207-2215, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31851050

RESUMO

PURPOSE: To compare retinal vessel oxygenation in eyes with an untreated choroidal nevus or choroidal melanoma. METHODS: The affected and fellow eye of patients with an untreated choroidal nevus (n = 42) or choroidal melanoma (n = 45) were investigated using noninvasive retinal oximetry (Oxymap T1). Oxygen saturation of arterioles (ArtSat) and venules (VenSat) was determined, together with the arteriovenous difference (AV-difference). RESULTS: In choroidal nevus patients, retinal oximetry did not differ between the affected and fellow eye: the mean ArtSat was 94.5% and 94.2% (P = 0.56), the VenSat was 60.5% and 61.3% (P = 0.35), and the AV-difference was 34.0% and 32.9% (P = 0.18), respectively. In choroidal melanoma patients, alterations were detected: the mean ArtSat was 94.8% and 93.2% (P = 0.006), the VenSat was 58.0% and 60.0% (P = 0.014), and the AV-difference was 36.8% and 33.2% (P < 0.001), respectively. The largest increase in AV-difference was observed between the retinal halves without the lesion in melanoma eyes compared with the corresponding half in the fellow eye (37.5% vs. 32.1%, P < 0.001). CONCLUSION: Although retinal oximetry was not significantly altered in eyes with a choroidal nevus, eyes with choroidal melanoma showed an increased ArtSat and decreased VenSat, leading to an increased AV-difference. These changes may be caused by inflammation and a higher metabolism, with larger oxygen consumption, leading to altered blood flow and intraocular oxygen relocation.


Assuntos
Neoplasias da Coroide/fisiopatologia , Melanoma/fisiopatologia , Nevo Pigmentado/fisiopatologia , Oxigênio/sangue , Vasos Retinianos/fisiopatologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oximetria , Consumo de Oxigênio/fisiologia
3.
Laeknabladid ; 109(5): 231, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37166090
4.
Acta Paediatr ; 105(6): 689-94, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26948070

RESUMO

AIM: A well-documented, clinically proven per rectum treatment for childhood constipation is needed. This phase two clinical trial evaluated the efficacy of suppositories containing free fatty acids (FFA) compared with Klyx docusate sodium and sorbitol enemas. METHODS: A randomised, controlled, single-blind study was undertaken on 77 children aged between one and 17 who presented to an emergency department in Iceland and were diagnosed with constipation. In stage one, 23 patients were randomised to receive lower dose FFA suppositories or Klyx (n = 33). In stage two, 21 different patients were randomised to receive higher dose suppositories and compared with the same Klyx control subjects. RESULTS: The suppositories were effective at bowel emptying in 39% of the group who received the lower FFA doses and 81% of the group receiving higher doses, compared with 88% in the Klyx control group. Symptom relief was obtained in 30% of the group receiving the lower doses and 71% of the group receiving the higher doses, compared with 73% in the control group. CONCLUSION: The higher dose FFA suppositories were as effective as the Klyx enemas with regard to bowel emptying and symptom relief and might provide an important and less invasive alternative for childhood constipation.


Assuntos
Constipação Intestinal/tratamento farmacológico , Defecação/efeitos dos fármacos , Ácidos Graxos não Esterificados/uso terapêutico , Administração Retal , Catárticos/uso terapêutico , Criança , Pré-Escolar , Ácido Dioctil Sulfossuccínico/uso terapêutico , Enema , Ácidos Graxos não Esterificados/farmacologia , Feminino , Humanos , Lactente , Masculino , Sorbitol/uso terapêutico , Supositórios , Tensoativos/uso terapêutico
5.
Graefes Arch Clin Exp Ophthalmol ; 253(10): 1653-61, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25404523

RESUMO

PURPOSE: To estimate the presence and variability of retinal hypoxia in patients with central retinal vein occlusion (CRVO). METHOD: Hemoglobin oxygen saturation was measured in retinal vessels of both eyes in 14 patients with unilateral CRVO. The noninvasive spectrophotometric retinal oximeter is based on a fundus camera and simultaneously captures two images at 570 nm and 600 nm wavelengths. Five of the patients were followed with repeated retinal oximetry images over time. RESULTS: The mean oxygen saturation in retinal venules was 31 % ±12 % in CRVO eyes and 52 % ±11 % in unaffected fellow eyes (mean ±SD, n = 14, p < 0.0001). The arteriovenous difference was 63 % ±11 % in eyes with CRVO and 43 % ±7 % in fellow eyes (p < 0.0001). The variability of retinal venous oxygen saturation was substantial within and between eyes affected by CRVO. Venular oxygen saturation improved with treatment and over time in all five patients that were followed. CONCLUSION: CRVO eyes are hypoxic compared to fellow eyes and arteriovenous difference in hemoglobin oxygen saturation is increased. This is consistent with tissue hypoxia resulting from reduced blood flow. Further studies are needed to understand the correlation between hypoxia, severity of disease and prognosis.


Assuntos
Hipóxia/fisiopatologia , Oxigênio/sangue , Oclusão da Veia Retiniana/fisiopatologia , Veia Retiniana/fisiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Angiofluoresceinografia , Humanos , Masculino , Pessoa de Meia-Idade , Oximetria , Estudos Prospectivos , Fluxo Sanguíneo Regional , Vênulas/fisiologia
6.
Pharm Dev Technol ; 20(5): 626-32, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-24754413

RESUMO

Aqueous nanoparticulated eye drop formulations based on γ-cyclodextrin (γCD) complexes were developed and tested in vitro. Three antihypertensive drugs, i.e. enalapril maleate, irbesartan and verapamil HCl, that have been shown to possess IOP-lowering activity were selected for this study. All three drugs displayed Bs-type phase-solubility diagrams in aqueous γCD solutions and had relatively low affinity for γCD. Irbesartan was selected for further formulation development. The drug was relatively stable at pH 4.5 but somewhat less stable at physiologic pH. However, presence of γCD in the aqueous media enhanced the chemical stability of irbesartan. Aqueous γCD-based eye drop formulations containing 1% and 2% (w/v) irbesartan were prepared and the effect of pH on the particles size distribution and drug release investigated. Only ∼2% of the drug was in solution in the pH 4.5 formulations but up to 45% in the pH 7 formulations. The pH 7 formulations, where larger fraction of the drug was in solution, displayed somewhat greater drug permeation flux but much lower drug permeation coefficients than the pH 4.5 formulations. Dynamic light scattering studies indicated the faster permeation was due to formation of smaller particles in presence tyloxapol.


Assuntos
Anti-Hipertensivos/administração & dosagem , Compostos de Bifenilo/administração & dosagem , Enalapril/administração & dosagem , Soluções Oftálmicas/química , Tetrazóis/administração & dosagem , Verapamil/administração & dosagem , gama-Ciclodextrinas/química , Anti-Hipertensivos/química , Compostos de Bifenilo/química , Enalapril/química , Irbesartana , Permeabilidade , Solubilidade , Tetrazóis/química , Verapamil/química
7.
Int J Pharm ; 655: 124018, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38508428

RESUMO

Tyrosine kinase inhibitors (TKIs) can inhibit edema and neovascularization, such as in age-related macular degeneration and diabetic retinopathy. However, their topical administration in ophthalmology is limited by their toxicity and poor aqueous solubility. There are multiple types of TKIs, and each TKI has an affinity to more than one type of receptor. Studies have shown that ocular toxicity can be addressed by selecting TKIs that have a high affinity for specific vascular endothelial growth factor receptors (VEGFRs) but a low affinity for epidermal growth factor receptors (EGFRs). Drugs permeate from the aqueous tear fluid into the eye via passive diffusion. Thus, a sustained high concentration of the dissolved drug in the aqueous tear fluid is essential for a successful delivery to posterior tissues such as the retina. Unfortunately, the aqueous solubility of the TKIs that have the most favorable VEGFR/EGFR affinity ratio, that is, axitinib and cabozantinib, is well below 1 µg/mL, making their topical delivery very challenging. This is a review of the drug-like properties of TKIs that are currently being evaluated or have been evaluated as ophthalmic drugs. These properties include their solubilization, cyclodextrin complexation, and ability to permeate from the aqueous tear fluid to the posterior eye segment.


Assuntos
Oftalmologia , Preparações Farmacêuticas , Fator A de Crescimento do Endotélio Vascular , Administração Tópica , Inibidores de Proteínas Quinases
8.
Acta Ophthalmol ; 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38470990

RESUMO

PURPOSE: To investigate the association between pretreatment blood flow velocity in the choroid and optic nerve head (ONH) and retinal oxygen metabolism in the acute uveitic phase and the development of 'sunset glow fundus' in Vogt-Koyanagi-Harada (VKH) disease. METHODS: Retrospective analysis of 41 patients (82 eyes). Laser speckle flowgraphy and retinal oximetry measurements were performed at the presentation. The main outcome measure was the development of 'sunset glow fundus'. RESULTS: Twenty patients (40 eyes) presented in the phase preceding anterior segment inflammation (early presentation), and 21 patients (42 eyes) presented with anterior segment inflammation (late presentation). In ONH, mean blur rate (MBR)-vessel, representing blood flow velocity in retinal vessels, was significantly lower in the late presentation group, while choroidal MBR was not significantly different. The late presentation group had significantly lower oxygen saturation in retinal venules, a higher arteriovenous oxygen saturation difference and a smaller calibre of retinal arterioles compared with the early presentation group. Eyes that subsequently developed 'sunset glow fundus' had significantly lower ONH MBR-vessels, lower oxygen saturation in retinal venules, a higher arteriovenous oxygen saturation difference and a smaller calibre of retinal arterioles compared with eyes without 'sunset glow fundus'. ONH MBR-vessel had a significant negative correlation with arteriovenous oxygen saturation difference and a significant positive correlation with calibre of retinal arterioles. CONCLUSIONS: In the acute uveitic phase of VKH disease, the development of 'sunset glow fundus' is associated with pretreatment reduced retinal blood flow velocity, calibre of retinal arterioles and oxygen saturation in retinal venules, as well as an increased arteriovenous oxygen saturation difference.

9.
Acta Ophthalmol ; 102(3): 312-317, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37571978

RESUMO

PURPOSE: To evaluate a new automated retinal oximetry image quality indicator with cataract as a clinical model. METHODS: Sixty-one eyes in 61 patients were imaged by the Oxymap T1 Retinal Oximeter at baseline and 25 eyes were also examined 3 weeks after cataract surgery. Image quality (0-10 on a continuous scale) was compared with standardized AREDS cataract grading and Pentacam lens densitometry. Associations with retinal oximetry measurements and visual acuity were examined. RESULTS: Image quality correlated with total, nuclear and posterior subcapsular cataract grades (ANOVA, p < 0.05), tended to be associated with lens densitometry and it improved from 4.3 ± 1.4 to 5.7 ± 1.0 (p < 0.05) after cataract surgery. Very low image quality, below 3, led to vessel detection failure in retinal oximetry images. Higher image qualities were linearly associated with higher measured retinal oxygen saturations (r = 0.52 in arteries and r = 0.46 in veins; p < 0.001). CONCLUSION: Retinal oximetry image quality deteriorated with increasing cataract density and improved after cataract surgery, supporting its use as a measure of optical clarity. The numerical quality indicator demonstrated a threshold below which images of poor optical quality should be discarded. Image quality affects the estimates of retinal oximetry parameters and should therefore be included in future analyses.


Assuntos
Catarata , Indicadores de Qualidade em Assistência à Saúde , Humanos , Vasos Retinianos , Oximetria/métodos , Oxigênio , Catarata/diagnóstico
10.
Eye (Lond) ; 37(7): 1432-1438, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-35768722

RESUMO

OBJECTIVES: To investigate the association of optic nerve head (ONH) swelling in the acute uveitic phase of Vogt-Koyanagi-Harada (VKH) disease with blood flow velocity in the choroid and ONH and oxygen saturation and diameter of retinal vessels. METHODS: In this prospective study, 25 patients (50 eyes) were studied. Thirteen patients (26 eyes) had ONH swelling and 12 patients (24 eyes) had no ONH swelling. Laser speckle flowgraphy (LSFG) and retinal oximetry measurements were performed at presentation. RESULTS: In the ONH, mean blur rate (MBR)-vessel, representing blood flow velocity in retinal vessels, was significantly lower in the eyes affected by ONH swelling, while choroidal MBR was not significantly different. Eyes with ONH swelling had a significantly lower oxygen saturation in retinal venules, a significantly higher arteriovenous oxygen saturation difference and a significantly smaller calibre of retinal arterioles compared with eyes without ONH swelling. There were significant positive correlations between the MBR-vessel of the ONH and venular oxygen saturation and calibre of retinal arterioles. In addition, MBR-vessel of the ONH had a significant negative correlation with arteriovenous oxygen saturation difference. CONCLUSIONS: The occurrence of ONH swelling in the acute uveitic phase of VKH disease is associated with lower retinal blood flow velocity and smaller calibre of retinal arterioles as well as lower oxygen saturation in retinal venules and higher arteriovenous difference in oxygen saturation.


Assuntos
Disco Óptico , Papiledema , Uveíte , Síndrome Uveomeningoencefálica , Humanos , Disco Óptico/irrigação sanguínea , Oxigênio , Estudos Prospectivos , Velocidade do Fluxo Sanguíneo/fisiologia , Fluxo Sanguíneo Regional/fisiologia
11.
Acta Ophthalmol ; 101(1): 22-33, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35848336

RESUMO

PURPOSE: To evaluate topical dexamethasone ophthalmic suspension OCS-01 (Oculis SA, Lausanne, Switzerland) in diabetic macular edema (DME). METHODS: This was a multicenter, double-masked, parallel-group, randomized, Phase 2 study. Patients aged 18-85 years with DME of <3 years duration, ETDRS central subfield thickness ≥ 310 µm by SD-OCT, and ETDRS letter score ≤ 73 and ≥ 24 in the study eye were randomized 2:1 to OCS-01 or matching vehicle, 1 drop 3 times/day for 12 weeks. Efficacy was evaluated as change from baseline to Week 12 of ETDRS letter score and central macular thickness (CMT). The primary analysis used a linear model with baseline ETDRS letters as a covariate, and missing data imputed using multiple imputation pattern mixture model techniques. Active treatment was considered superior to vehicle if the one-sided p-value was <0.15 and the difference in mean change from baseline in ETDRS letters was >0. RESULTS: Mean CMT showed a greater decrease from baseline with OCS-01 (N = 99) than vehicle (N = 45) at Week 12 (-53.6 vs -16.8 µm, p = 0.0115), with significant differences favouring OCS-01 from Weeks 2 to 12. OCS-01 was well-tolerated, and increased intraocular pressure was the most common adverse event. Mean change in ETDRS letter score from baseline to Week 12 met the p was +2.6 letters with topical OCS-01 and 1 letter with vehicle (p = 0.125). In a post-hoc analysis, there was a greater difference in patients with baseline BCVA ≤65 letters, the OCS-01 group improved 3.8 letters compared with 0.9 letters with vehicle. CONCLUSION: Topical OCS-01 was significantly more effective than vehicle in improving central macular thickness in patients with DME. Visual improvement was better in eyes with lower baseline vision.


Assuntos
Diabetes Mellitus , Retinopatia Diabética , Macula Lutea , Edema Macular , Humanos , Edema Macular/diagnóstico , Edema Macular/tratamento farmacológico , Edema Macular/etiologia , Retinopatia Diabética/complicações , Retinopatia Diabética/diagnóstico , Retinopatia Diabética/tratamento farmacológico , Acuidade Visual , Injeções Intravítreas , Tomografia de Coerência Óptica/métodos , Dexametasona , Resultado do Tratamento , Inibidores da Angiogênese
12.
Retina ; 37(2): e24, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-28060149
13.
Mar Drugs ; 10(9): 2047-2054, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23118720

RESUMO

UNLABELLED: Cod-liver oil and other marine products containing polyunsaturated fatty acids have anti-inflammatory, anti-bacterial and anti-viral effects and may be useful in the treatment of various inflammatory and infectious diseases. We developed suppositories and ointment with 30% free fatty acid (FFA) extract from omega-3 fish oil. Our purpose was to evaluate the safety of marine lipid suppositories and ointment in healthy volunteers and to explore the laxative effect of the suppositories. Thirty healthy volunteers were randomized either to a study group administrating 30% FFA suppositories and applying 30% FFA ointment to the perianal region twice per day for two weeks, or to a control group using placebo suppositories and ointment in a double blinded manner. RESULTS: No serious toxic effects or irritation were observed. In the study group 93% felt the urge to defecate after administration of the suppositories as compared to 37% in the control group (P = 0.001). Subsequently 90% in the study group defecated, compared to 33% in the control group (P = 0.001). CONCLUSION: The marine lipid suppositories and ointment were well tolerated with no significant toxic side effects observed during the study period. The suppositories have a distinct laxative effect and we aim to explore this effect in further clinical trials.


Assuntos
Ácidos Graxos Ômega-3/administração & dosagem , Óleos de Peixe/administração & dosagem , Laxantes/administração & dosagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Método Duplo-Cego , Ácidos Graxos Ômega-3/efeitos adversos , Ácidos Graxos Ômega-3/química , Feminino , Óleos de Peixe/efeitos adversos , Óleos de Peixe/química , Humanos , Laxantes/efeitos adversos , Laxantes/química , Masculino , Pessoa de Meia-Idade , Pomadas/administração & dosagem , Pomadas/efeitos adversos , Pomadas/química , Supositórios/administração & dosagem , Supositórios/efeitos adversos , Supositórios/química , Adulto Jovem
14.
Acta Ophthalmol ; 100(1): 7-25, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33876553

RESUMO

Using topical application to deliver therapeutic concentrations of drugs to the posterior segment of the eye remains very challenging. As a result, posterior segment diseases are usually treated by intravitreal injection or implant. While topical treatments are commonly used for anterior segment conditions, they sometimes require frequent applications. Eye drop formulations based on γ-cyclodextrin (γCD)-based nanoparticle aggregates were developed, which in animal models and clinical studies deliver therapeutic concentrations of drugs (dorzolamide and dexamethasone) to both anterior and posterior segments of the eye. An early study in humans showed dorzolamide/γCD eye drops could achieve comparable intraocular pressure decreases to commercial dorzolamide eye drops, but with less frequent application. Pilot studies with dexamethasone/γCD eye drops suggested that they could be effective in a range of conditions, including diabetic macular oedema, cystoid macular oedema and vitritis secondary to uveitis, postcataract surgery inflammation and postoperative treatment in trabeculectomy. Phase II studies with similar dexamethasone/γCD nanoparticle eye drops in diabetic macular oedema and postcataract surgery inflammation have recently been completed. This technology has the potential to be used with other classes of drug molecules and to replace or complement invasive treatments, providing safer, non-invasive therapies, particularly for posterior segment conditions, that can be self-administered as eye drops by patients.


Assuntos
Humor Aquoso/metabolismo , Ciclodextrinas/farmacocinética , Sistemas de Liberação de Medicamentos , Oftalmopatias/tratamento farmacológico , Nanopartículas/administração & dosagem , Animais , Segmento Anterior do Olho , Ciclodextrinas/administração & dosagem , Relação Dose-Resposta a Droga , Oftalmopatias/metabolismo , Humanos , Soluções Oftálmicas , Segmento Posterior do Olho
15.
Pharmaceutics ; 14(6)2022 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-35745720

RESUMO

This study aimed to develop a chemically stable niosomal eye drop containing fosinopril (FOS) for lowering intraocular pressure. The effects of cyclodextrin (CD), surfactant types and membrane stabilizer/charged inducers on physiochemical and chemical properties of niosome were evaluated. The pH value, average particle size, size distribution and zeta potentials were within the acceptable range. All niosomal formulations were shown to be slightly hypertonic with low viscosity. Span® 60/dicetyl phosphate niosomes in the presence and absence of γCD were selected as the optimum formulations according to their high %entrapment efficiency and negative zeta potential values as well as controlled release profile. According to ex vivo permeation study, the obtained lowest flux and apparent permeability coefficient values confirmed that FOS/γCD complex was encapsulated within the inner aqueous core of niosome and could be able to protect FOS from its hydrolytic degradation. The in vitro cytotoxicity revealed that niosome entrapped FOS or FOS/γCD formulations were moderate irritation to the eyes. Furthermore, FOS-loaded niosomal preparations exhibited good physical and chemical stabilities especially of those in the presence of γCD, for at least three months under the storage condition of 2-8 °C.

16.
Acta Ophthalmol ; 100(7): 788-796, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35080812

RESUMO

PURPOSE: Tyrosine kinase inhibitors inhibit VEGF receptors. If delivered to the retina, they might inhibit oedema and neovascularization such as in age-related macular degeneration and diabetic retinopathy. The aim of this study was to formulate cediranib maleate, a potent VEGF inhibitor, as γ-cyclodextrin nanoparticle eye drops and measure the retinal delivery and overall ocular pharmacokinetics after a single-dose administration in rabbits. METHODS: A novel formulation technology with 3% cediranib maleate as γ-cyclodextrin micro-suspension was prepared by autoclaving method. Suitable stabilizers were tested for heat-stable eye drops. The ophthalmic formulation was topically applied to one eye in rabbits. The pharmacokinetics in ocular tissues, tear film and blood samples were studied at 1, 3 and 6 hr after administration. RESULTS: γ-cyclodextrin formed complex with cediranib maleate. The formation of γ-cyclodextrin nanoparticles occurred in concentrated complexing media. Combined stabilizers prevented the degradation of drug during the autoclaving process. Three hours after administration of the eye drops, treated eyes showed cediranib levels of 737 ± 460 nM (mean ± SD) in the retina and 10 ± 6 nM in the vitreous humour. CONCLUSIONS: Cediranib maleate in γ-cyclodextrin nanoparticles were stable to heat in presence of stabilizers. The drug as eye drops reached the retina in concentrations that are more than 100 times higher than the 0.4 nM IC50 value reported for the VEGF type-II receptor and thus, presumably, above therapeutic level. These results suggest that γ-cyclodextrin-based cediranib maleate eye drops deliver effective drug concentrations to the retina in rabbits after a single-dose administration.


Assuntos
Ciclodextrinas , Nanopartículas , gama-Ciclodextrinas , Administração Tópica , Animais , Ciclodextrinas/metabolismo , Ciclodextrinas/farmacologia , Indóis , Maleatos/metabolismo , Maleatos/farmacologia , Soluções Oftálmicas , Inibidores de Proteínas Quinases/farmacologia , Quinazolinas , Coelhos , Retina/metabolismo , Fator A de Crescimento do Endotélio Vascular/metabolismo , gama-Ciclodextrinas/farmacocinética
17.
Graefes Arch Clin Exp Ophthalmol ; 249(9): 1311-7, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21499769

RESUMO

BACKGROUND: The purpose of this study was to test the reliability of vessel diameter measurements with a newly developed retinal oximeter. METHODS: Twelve healthy individuals participated in the study. Retinal images were taken with the Oxymap Retinal Oximeter. Diameters of retinal vessels were measured automatically with the Oxymap Analyzer software. Repeated measurements on the same vessel segments were compared. The automatic measurements were also compared with semi-automatic measurements with a plug-in for the ImageJ software. RESULTS: Variance coefficient (standard deviation/mean) from the repeatability test was 2.8 and 4.0% for first- and second-degree venules and 3.5 and 5.4% for first- and second-degree arterioles, respectively. ImageJ measured larger mean diameters than Oxymap Analyzer in all cases. Means of differences were 5.1 ± 2.2, 2.9 ± 1.3, and 2.7 ± 1.6 pixels for first-, second-, and third-degree venules and 3.1 ± 1.2, 2.7 ± 0.9, and 2.9 ± 1.4 pixels for first-, second-, and third-degree arterioles. CONCLUSIONS: Vessel diameter measurements with the oximeter are repeatable and comparison with an established method demonstrates a relatively stable offset where the standard deviation of the difference is rather small. Different definitions of vessel borders may be the cause of this difference.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/normas , Oximetria/métodos , Oximetria/normas , Vasos Retinianos/anatomia & histologia , Vasos Retinianos/fisiologia , Adulto , Algoritmos , Arteríolas/anatomia & histologia , Arteríolas/fisiologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Masculino , Pessoa de Meia-Idade , Disco Óptico/irrigação sanguínea , Oximetria/instrumentação , Oxigênio/metabolismo , Reprodutibilidade dos Testes , Artéria Retiniana/anatomia & histologia , Artéria Retiniana/fisiologia , Veia Retiniana/anatomia & histologia , Veia Retiniana/fisiologia , Software , Vênulas/anatomia & histologia , Vênulas/fisiologia
18.
Graefes Arch Clin Exp Ophthalmol ; 249(7): 997-1008, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21243370

RESUMO

BACKGROUND: Diabetes mellitus, as well as subsequent ocular complications such as cystoid macular edema (CME), are of fundametal socio-economic relevance. Therefore, we evaluated the influence of internal limiting membrane (ILM) removal on longterm morphological and functional outcome in patients with diabetes mellitus (DM) type 2 and chronic CME without evident vitreomacular traction. METHOD: Forty eyes with attached posterior hyaloid were included in this prospective trial and randomized intraoperatively. Prior focal (n = 31) or panretinal (n = 25) laser coagulation was permitted. Group I (n = 19 patients) underwent surgical induction of posterior vitreous detachment (PVD), group II (n = 20 patients) PVD and removal of the ILM. Eleven patients with detached posterior hyaloid (group III) were not randomized, and ILM removal was performed. One eye had to be excluded from further analysis. Examinations included ETDRS best-corrected visual acuity (BCVA), fluorescein angiography (FLA) and OCT at baseline, 3 and 6 months postoperatively. Main outcome measure was BCVA at 6 months, secondary was foveal thickness. RESULTS: Mean BCVA over 6 months remained unchanged in 85% of patients of group II, and decreased in 53% of patients of group I. Results were not statistically significant different [group I: mean decrease log MAR 95% CI (0.06; 0.32), group II: (-0.02; 0.11)]. OCT revealed a significantly greater reduction of foveal thickness following PVD with ILM removal [group I: mean change: 95% CI (-208.95 µm; -78.05 µm), group II: (-80.90 µm: +59.17 µm)]. CONCLUSION: Vitrectomy, PVD with or without ILM removal does not improve vision in patients with DM type 2 and cystoid diabetic macular edema without evident vitreoretinal traction. ILM delamination shows improved morphological results, and appears to be beneficial in eyes with preexisting PVD.


Assuntos
Membrana Basal/cirurgia , Retinopatia Diabética/cirurgia , Edema Macular/cirurgia , Vitrectomia , Corpo Vítreo/cirurgia , Idoso , Membrana Basal/metabolismo , Biomarcadores/metabolismo , Diabetes Mellitus Tipo 2/complicações , Retinopatia Diabética/fisiopatologia , Feminino , Angiofluoresceinografia , Humanos , Técnicas Imunoenzimáticas , Verde de Indocianina , Edema Macular/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia de Coerência Óptica , Resultado do Tratamento , Acuidade Visual/fisiologia
19.
PLoS One ; 16(5): e0251607, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33979414

RESUMO

PURPOSE: According to cross-sectional studies, oxygen saturation is elevated in retinal vessels in diabetic patients. We evaluated how retinal oxygenation (metabolic marker), vessel diameters and retinopathy grade (structural markers) change over time in diabetic patients. DESIGN: Prospective cohort study following screening in a hospital setting. METHODS: Retinal oximetry images were acquired in 214 patients with the Oxymap T1 oximeter. Imaging was repeated after a median of 3.0 years (range 0.76-6.8 years). Oxygen saturation and vessel diameters were measured in the right eye. Semiquantitative grading of retinopathy according to international guidelines and red lesion count were performed on fundus photographs. RESULTS: Retinopathy grade according to the international semiquantitative grading system was unchanged. Arteriolar saturation increased by 0.75±0.15 percentage points per year of follow-up (p<0.0001). Venular saturation increased by 1.74±0.26 percentage points per year (p<0.0001) and arteriovenous difference decreased by 0.99±0.20 percentage points per year (p<0.0001). Arteriolar diameters decreased by 2.7±8.5µm (p<0.0001) between visits and venular diameters decreased by 2.4±9.1µm (p = 0.0002). Median increase in red lesion count between visits was 2 lesions (range -128 to 212 lesions, p<0.0001). The change in red lesion count and change in diameters did not correlate with the length of follow-up (p>0.44). CONCLUSIONS: Oxygen saturation in larger retinal vessels can increase and arteriovenous difference can decrease over time in diabetic patients without any observable changes in retinopathy grade. The results suggest that changes in retinal oxygen saturation may precede progression of diabetic retinopathy or that oxygen saturation is more sensitive to disease progression than retinopathy grade.


Assuntos
Retinopatia Diabética/diagnóstico por imagem , Retina/diagnóstico por imagem , Adulto , Idoso , Estudos Transversais , Retinopatia Diabética/fisiopatologia , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oximetria , Retina/fisiopatologia , Vasos Retinianos/fisiopatologia , Índice de Gravidade de Doença
20.
Int J Pharm ; 606: 120955, 2021 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-34332063

RESUMO

Carbonic anhydrase inhibitors (CAIs) are used as systemic and topical agents for lowering intraocular pressure (IOP) in patients with glaucoma. Owing to the wide distribution of CAs and their physiological functions in various tissues, systemic administration of CAIs may lead to unwanted side effects. Thus, exploration of drugs targeting the specific CA isoenzyme in ocular tissues and application of the same as topical eye drops would be desirable. However, the anatomical and physiological barriers of the eyes can limit drug availability at the site. The very low aqueous solubility of CAI agents can further hamper drug bioavailability, consequently resulting in insufficient therapeutic efficacy. Solubilization of drugs using cyclodextrin (CD) complexes can enhance both solubility and permeability of the drugs. The use of CD for such purposes and development and testing of topical CAI eye drops containing CD have been discussed in detail. Further, pharmaceutical nanotechnology platforms were discussed in terms of investigation of their IOP-lowering efficacies. Future prospects in drug discovery and the use of CD nanoparticles and CD-based nanocarriers to develop potential topical CAI formulations have also been described here.


Assuntos
Ciclodextrinas , Glaucoma , Administração Tópica , Inibidores da Anidrase Carbônica , Glaucoma/tratamento farmacológico , Humanos , Pressão Intraocular , Sulfonamidas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA