Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Eur Heart J ; 45(7): 510-518, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-37624879

RESUMO

BACKGROUND AND AIMS: Atrial fibrillation (AF) is a chronic progressive disorder. Persistent forms of AF are associated with increased rates of thromboembolism, heart failure, and death. Catheter ablation modifies the pathogenic mechanism of AF progression. No randomized studies have evaluated the impact of the ablation energy on progression to persistent atrial tachyarrhythmia. METHODS: Three hundred forty-six patients with drug-refractory paroxysmal AF were enrolled and randomly assigned to contact-force-guided RF ablation (CF-RF ablation, 115), 4 min cryoballoon ablation (CRYO-4, 115), or 2 min cryoballoon ablation (CRYO-2, 116). Implantable cardiac monitors placed at study entry were used for follow-up. The main outcome was the first episode of persistent atrial tachyarrhythmia. Secondary outcomes included atrial tachyarrhythmia recurrence and arrhythmia burden on the implantable monitor. RESULTS: At a median of 944.0 (interquartile range [IQR], 612.5-1104) days, 0 of 115 patients (0.0%) randomly assigned to CF-RF, 8 of 115 patients (7.0%) assigned to CRYO-4, and 5 of 116 patients (4.3%) assigned to CRYO-2 experienced an episode of persistent atrial tachyarrhythmia (P = .03). A documented recurrence of any atrial tachyarrhythmia ≥30 s occurred in 56.5%, 53.9%, and 62.9% of those randomized to CF-RF, CRYO-4, and CRYO-2, respectively; P = .65. Compared with that of the pre-ablation monitoring period, AF burden was reduced by a median of 99.5% (IQR 94.0%, 100.0%) with CF-RF, 99.9% (IQR 93.3%-100.0%) with CRYO-4, and 99.1%% (IQR 87.0%-100.0%) with CRYO-2 (P = .38). CONCLUSIONS: Catheter ablation of paroxysmal AF using radiofrequency energy was associated with fewer patients developing persistent AF on follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Taquicardia , Recidiva , Veias Pulmonares/cirurgia
2.
J Cardiovasc Electrophysiol ; 23(12): 1313-6, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22788915

RESUMO

INTRODUCTION: The need to perform defibrillation testing (DT) at the time of implantable cardioverter defibrillator (ICD) insertion is controversial. In the absence of randomized trials, some regions now perform more than half of ICD implants without DT. METHODS: During the last year of enrolment in the Resynchronization for Ambulatory Heart Failure Trial, a substudy randomized patients to ICD implantation with versus without DT. RESULTS: Among 252 patients screened, 145 were enrolled; 75 randomized to DT and 70 to no DT. Patients were similar in terms of age (65.9 ± 9.3 years vs 67.9 ± 8.9 years); LVEF (24.7 ± 4.6% vs 23.6 ± 4.6%), QRS width (154.8 ± 23.5 vs 155.8 ± 23.6 ms), and history of atrial fibrillation (5% vs 6%). All 68 patients in the DT arm tested according to the protocol achieved a successful DT (≤25 J); 96% without requiring any system modification. No patient experienced perioperative stroke, myocardial infarction, heart failure (HF), intubation or unplanned ICU stay. The length of hospital stay was not prolonged in the DT group: 20.2 ± 26.3 hours versus 21.3 ± 23.0 hours, P = 0.79. One patient in the DT arm had a failed appropriate shock and no patient suffered an arrhythmic death. The composite of HF hospitalization or all-cause mortality occurred in 10% of patients in the no-DT arm and 19% of patients in the DT arm (HR = 0.53, 95% CI: 0.21-1.31, P = 0.14). CONCLUSIONS: In this randomized trial, perioperative complications, failed appropriate shocks, and arrhythmic death were all uncommon regardless of DT. There was a nonsignificant increase in the risk of death or HF hospitalization with DT.


Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Cardioversão Elétrica/estatística & dados numéricos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/cirurgia , Monitorização Intraoperatória/estatística & dados numéricos , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/cirurgia , Idoso , Comorbidade , Cardioversão Elétrica/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Técnicas Eletrofisiológicas Cardíacas/estatística & dados numéricos , Feminino , Insuficiência Cardíaca/mortalidade , Humanos , Incidência , Masculino , Monitorização Intraoperatória/métodos , Ontário/epidemiologia , Projetos Piloto , Fatores de Risco , Análise de Sobrevida , Taxa de Sobrevida , Resultado do Tratamento , Disfunção Ventricular Esquerda/mortalidade
3.
Heart Rhythm ; 18(9): 1463-1470, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34126269

RESUMO

BACKGROUND: Early recurrence of atrial tachyarrhythmia (ERAT) is common after pulmonary vein isolation (PVI) and has been associated with an increased risk of late atrial fibrillation (AF) recurrence. OBJECTIVE: The purpose of this study was to determine the incidence and outcomes of patients experiencing ERAT after PVI using advanced-generation ablation technologies. METHODS: This is a prespecified substudy of the CIRCA-DOSE (Cryoballoon vs Irrigated Radiofrequency Catheter Ablation: Double-Short vs Standard Exposure Duration) trial, a prospective, randomized, multicenter study comparing PVI with contact force-guided radiofrequency ablation to secondary-generation cryoballoon ablation for paroxysmal AF. All study patients received an implantable cardiac monitor to allow continuous rhythm monitoring. ERAT was defined as any recurrent atrial tachyarrhythmia within the first 90 days after AF ablation. RESULTS: ERAT occurred in 61% of the 346 patients at a median of 12 days (range 1-90 days) after ablation. ERAF was a significant predictor of late recurrence (60.1% with ER vs 25.9% without ER; P <.001) and symptomatic atrial tachyarrhythmia (31.6% with ERAF vs 6.7% without ERAF; P <.001). Receiver operating curve analyses revealed a strong correlation between ERAT timing and burden and late recurrence. Multivariate analysis identified ER timing (hazard ratio [HR] 2.90; 95% confidence interval [CI] 1.41-5.95; P = .004) and burden (HR 1.05 per 1% ER burden; 95% CI 1.04-1.07; P <.001) as strong independent predictors of late recurrence. Incidence rate, timing, burden, and prognostic significance of ER did not differ between the study groups. CONCLUSION: ERAT remains common after PVI despite use of advanced-generation ablation technologies. Early AF recurrence beyond 3 weeks after ablation is associated with increased risk of late recurrence.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Sistema de Condução Cardíaco/fisiopatologia , Complicações Pós-Operatórias/epidemiologia , Veias Pulmonares/cirurgia , Fibrilação Atrial/fisiopatologia , Canadá/epidemiologia , Feminino , Seguimentos , Átrios do Coração/fisiopatologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prevalência , Prognóstico , Estudos Prospectivos , Recidiva , Fatores de Tempo
4.
Can J Cardiol ; 37(10): 1648-1650, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34010633

RESUMO

The Medical Assistance in Dying (MAiD) program has been steadily expanding in Canada, and is expected to continue to do so. There are a substantial number of Canadians with pacemakers and defibrillators, many of whom are potential MAiD recipients. There is a need for review and reflection of standardisation of cardiac device management in MAiD patients, not only because of ethical concerns, but also because of the complexity of management at end of life. This document examines the status and role of cardiac devices (pacemakers and intracardiac defibrillators) and their physiologic interactions and influences during the MAiD process, and provides recommendations for their management.


Assuntos
Doenças Cardiovasculares/terapia , Desfibriladores Implantáveis , Guias como Assunto , Assistência Médica/organização & administração , Assistência Terminal/normas , Doente Terminal , Canadá , Humanos , Assistência Terminal/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA