Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
J Adv Nurs ; 79(8): 3127-3146, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37002600

RESUMO

AIMS: To identify the needs, experiences and preferences of women with kidney disease in relation to their reproductive health to inform development of shared decision-making interventions. DESIGN: UK-wide mixed-methods convergent design (Sep 20-Aug 21). METHODS: Online questionnaire (n = 431) with validated components. Purposively sampled semi-structured interviews (n = 30). Patient and public input throughout. FINDINGS: Kidney disease was associated with defeminization, negatively affecting current (sexual) relationships and perceptions of future life goals. There was little evidence that shared decision making was taking place. Unplanned pregnancies were common, sometimes influenced by poor care and support and complicated systems. Reasons for (not) wanting children varied. Complicated pregnancies and miscarriages were common. Women often felt that it was more important to be a "good mother" than to address their health needs, which were often unmet and unrecognized. Impacts of pregnancy on disease and options for alternates to pregnancy were not well understood. CONCLUSION: The needs and reproductive priorities of women are frequently overshadowed by their kidney disease. High-quality shared decision-making interventions need to be embedded as routine in a feminized care pathway that includes reproductive health. Research is needed in parallel to examine the effectiveness of interventions and address inequalities. IMPACT: We do not fully understand the expectations, needs, experiences and preferences of women with kidney disease for planning and starting a family or deciding not to have children. Women lack the knowledge, resources and opportunities to have high-quality conversations with their healthcare professionals. Decisions are highly personal and related to a number of health, social and cultural factors; individualized approaches to care are essential. Healthcare services need to be redesigned to ensure that women are able to make informed choices about pregnancy and alternative routes to becoming a parent. PATIENT OR PUBLIC CONTRIBUTION: The original proposal for this research came from listening to the experiences of women in clinic who reported unmet needs and detailed experiences of their pregnancies (positive and negative). A patient group was involved in developing the funding application and helped to refine the objectives by sharing their experiences. Two women who are mothers living with kidney disease were co-opted as core members of the research team. We hosted an interim findings event and invited patients and wider support services (adoption, fertility, surrogacy, education and maternal chronic kidney disease clinics) from across the UK to attend. We followed the UK national standards for patient and public involvement throughout.


Assuntos
Procedimentos Clínicos , Tomada de Decisões , Nefropatias , Poder Familiar , Criança , Feminino , Humanos , Gravidez , Reprodução
2.
Health Expect ; 25(2): 579-606, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34964215

RESUMO

CONTEXT: Too many people living with chronic kidney disease are opting for and starting on hospital-based dialysis compared to a home-based kidney replacement therapy. Dialysis services are becoming financially unsustainable. OBJECTIVE: This study aimed to assess the efficacy of coproductive research in chronic kidney disease service improvement to achieve greater sustainability. DESIGN: A 2-year coproductive service improvement study was conducted with multiple stakeholders with the specific intention of maximizing engagement with the national health kidney services, patients and public. SETTING AND PARTICIPANTS: A national health kidney service (3 health boards, 18 dialysis units), patients and families (n = 50), multidisciplinary teams including doctors, nurses, psychologists, social workers, and so forth (n = 68), kidney charities, independent dialysis service providers and wider social services were part of this study. FINDINGS: Coproductive research identified underutilized resources (e.g., patients on home dialysis and social services) and their potential, highlighted unmet social care needs for patients and families and informed service redesign. Education packages were reimagined to support the home dialysis agenda including opportunities for wider service input. The impacts of one size fits all approaches to dialysis on specialist workforce skills were made clearer and also professional, patient and public perceptions of key sustainability policies. DISCUSSION AND CONCLUSIONS: Patient and key stakeholders mapped out new ways to link services to create more sustainable models of kidney health and social care. Maintaining principles of knowledge coproduction could help achieve financial sustainability and move towards more prudent adult chronic kidney disease services. PATIENT OR PUBLIC CONTRIBUTION: Involved in developing research questions, study design, management and conduct, interpretation of evidence and dissemination.


Assuntos
Médicos , Medicina Estatal , Adulto , Humanos , Rim , Diálise Renal , Apoio Social
3.
Clin Chem Lab Med ; 58(5): 673-681, 2020 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-31527291

RESUMO

Background The widespread availability of cannabis raises concerns regarding its effect on driving performance and operation of complex equipment. Currently, there are no established safe driving limits regarding ∆9-tetrahydrocannabinol (THC) concentrations in blood or breath. Daily cannabis users build up a large body burden of THC with residual excretion for days or weeks after the start of abstinence. Therefore, it is critical to have a sensitive and specific analytical assay that quantifies THC, the main psychoactive component of cannabis, and multiple metabolites to improve interpretation of cannabinoids in blood; some analytes may indicate recent use. Methods A liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed to quantify THC, cannabinol (CBN), cannabidiol (CBD), 11-hydroxy-THC (11-OH-THC), (±)-11-nor-9-carboxy-Δ9-THC (THCCOOH), (+)-11-nor-Δ9-THC-9-carboxylic acid glucuronide (THCCOOH-gluc), cannabigerol (CBG), and tetrahydrocannabivarin (THCV) in whole blood (WB). WB samples were prepared by solid-phase extraction (SPE) and quantified by LC-MS/MS. A rapid and simple method involving methanol elution of THC in breath collected in SensAbues® devices was optimized. Results Lower limits of quantification ranged from 0.5 to 2 µg/L in WB. An LLOQ of 80 pg/pad was achieved for THC concentrations in breath. Calibration curves were linear (R2>0.995) with calibrator concentrations within ±15% of their target and quality control (QC) bias and imprecision ≤15%. No major matrix effects or drug interferences were observed. Conclusions The methods were robust and adequately quantified cannabinoids in biological blood and breath samples. These methods will be used to identify cannabinoid concentrations in an upcoming study of the effects of cannabis on driving.


Assuntos
Canabinoides/análise , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Testes Respiratórios , Canabidiol/análise , Canabidiol/sangue , Canabidiol/isolamento & purificação , Canabidiol/normas , Canabinoides/sangue , Canabinoides/isolamento & purificação , Canabinoides/normas , Cromatografia Líquida de Alta Pressão/normas , Ácido Cítrico/química , Dronabinol/análise , Dronabinol/sangue , Dronabinol/isolamento & purificação , Dronabinol/normas , Glucose/análogos & derivados , Glucose/química , Humanos , Limite de Detecção , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , Fumar , Extração em Fase Sólida , Espectrometria de Massas em Tandem/normas , Estudos de Validação como Assunto
4.
Clin Chem ; 60(8): 1115-25, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24916795

RESUMO

BACKGROUND: High-resolution mass spectrometry (HRMS) has the potential to supplement other drug screening platforms used in toxicology laboratories. HRMS offers high analytical specificity, which can be further enhanced by incorporating a fragment ion for each analyte. The ability to obtain precursor ions and fragment ions using elevated collision energies (MS(E)) can help improve the specificity of HRMS methods. METHODS: We developed a broad-spectrum screening method on an ultraperformance liquid chromatography TOF mass spectrometer (UPLC-TOF-MS) using the MS(E) mode. A diverse set of patient samples were subjected to a simple dilute, hydrolyze, and shoot protocol and analyzed in a blind manner. Data were processed with 3 sets of criteria with increasing stringency, and the results were compared with the reference laboratory results. RESULTS: A combination of retention time match (±0.2 min), a protonated analyte, and fragment ion mass accuracy of ±5 ppm produced zero false-positive results. Using these criteria, we confirmed 92% (253/275) of true positives. The positive confirmation rate increased to 98% (270/275) when the requirement for a fragment ion was dropped, but also produced 53 false positives. A total of 136 additional positive drug findings not identified by the reference methods were identified with the UPLC-TOF-MS. CONCLUSIONS: MS(E) provides a unique way to incorporate fragment ion information without the need of precursor ion selection. A primary limitation of requiring a fragment ion for positive identification was that certain drug classes required high-energy collisions, which formed many fragment ions of low abundance that were not readily detected.


Assuntos
Cromatografia Líquida/métodos , Monitoramento de Medicamentos/métodos , Espectrometria de Massas/métodos , Voluntários Saudáveis , Humanos , Limite de Detecção
5.
J Mass Spectrom Adv Clin Lab ; 28: 82-90, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36937811

RESUMO

Tandem mass spectrometry is an important analytical tool for clinical laboratories, but tests developed and validated in-house (laboratory developed tests, or LDTs) require special consideration. In late 2022, the forecast for United States (U.S.) federal regulation of LDTs changed unexpectedly when the VALID Act was not passed by the U.S. Congress. This Act would have modified the Food and Drug Administration's (FDA's) role to increase regulatory oversight for LDT providers. In this revised context, we review optimization of quantitative mass spectrometry LDT validation and suggest avenues other than an additional FDA mandate to achieve uniform best practice. Common challenges, logistical barriers, and recommendations for easing the burden of best-quality quantitative mass spectrometry LDT method validation are discussed.

6.
Ann Emerg Med ; 59(6): 545-7, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21924518

RESUMO

Phencyclidine is one of the drugs of abuse included in qualitative urine drug screens that are frequently ordered in the emergency department despite concerns about specificity and clinical utility. Many drugs have been described to cause false-positive results for phencyclidine. We present 2 cases of false-positive phencyclidine qualitative urine drug screen results in patients with seizures from tramadol misuse or abuse. The involvement of tramadol and its active metabolite, N-desmethyltramadol, was confirmed by in vitro testing. These cases illustrate that tramadol and its metabolites can trigger a false-positive phencyclidine urine drug screen result in nonfatal cases and highlight the lack of specificity of the phencyclidine qualitative urine drug screen.


Assuntos
Fenciclidina/urina , Tramadol/efeitos adversos , Adulto , Serviço Hospitalar de Emergência , Reações Falso-Positivas , Feminino , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Imunoensaio , Masculino , Abuso de Fenciclidina/diagnóstico , Abuso de Fenciclidina/urina , Tramadol/análogos & derivados , Tramadol/urina
7.
Clin Mass Spectrom ; 16: 25-32, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34820517

RESUMO

•Policies applied to confirm LC-MS/MS-based results differ between laboratories.•We suggest a systematic approach for validation of individual diagnostic series.•An individual series validation plan can be established with a checklist.

8.
J Emerg Med ; 37(2): 115-23, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19097736

RESUMO

BACKGROUND: Studies of trauma systems have identified traumatic brain injury as a frequent cause of death or disability. Due to the heterogeneity of patient presentations, practice variations, and potential for secondary brain injury, the importance of early neurosurgical procedures upon survival remains controversial. Traditional observational outcome studies have been biased because injury severity and clinical prognosis are associated with use of such interventions. OBJECTIVE: We used propensity analysis to investigate the clinical efficacy of early neurosurgical procedures in patients with traumatic brain injury. METHODS: We analyzed a retrospectively identified cohort of 518 consecutive patients (ages 18-65 years) with blunt, traumatic brain injury (head Abbreviated Injury Scale score of >or= 3) presenting to the emergency department of a Level-1 trauma center. The propensity for a neurosurgical procedure (i.e., craniotomy or ventriculostomy) in the first 24 h was determined (based upon demographic, clinical presentation, head computed tomography scan findings, intracranial pressure monitor use, and injury severity). Multivariate logistic regression models for survival were developed using both the propensity for a neurosurgical procedure and actual performance of the procedure. RESULTS: The odds of in-hospital death were substantially less in those patients who received an early neurosurgical procedure (odds ratio [OR] 0.15; 95% confidence interval [CI] 0.05-0.41). The mortality benefit of early neurosurgical intervention persisted after exclusion of patients who died within the first 24 h (OR 0.13; 95% CI 0.04-0.48). CONCLUSIONS: Analysis of observational data after adjustment using the propensity score for a neurosurgical procedure in the first 24 h supports the association of early neurosurgical intervention and patient survival in the setting of significant blunt, traumatic brain injury. Transfer of at-risk head-injured patients to facilities with high-level neurosurgical capabilities seems warranted.


Assuntos
Lesões Encefálicas/cirurgia , Craniotomia/estatística & dados numéricos , Avaliação de Resultados em Cuidados de Saúde , Padrões de Prática Médica , Ferimentos não Penetrantes/cirurgia , Adulto , Lesões Encefálicas/diagnóstico , Tomada de Decisões , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Oregon , Transferência de Pacientes , Estudos Retrospectivos , Análise de Sobrevida , Fatores de Tempo , Centros de Traumatologia , Ventriculostomia/estatística & dados numéricos , Ferimentos não Penetrantes/diagnóstico
9.
Clin Mass Spectrom ; 11: 12-20, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34841068

RESUMO

INTRODUCTION: Immunoassays and liquid chromatography-tandem mass spectrometry assays are commonly employed in clinical laboratories for measurement of total testosterone in serum. Results obtained from either of these methodologies compare poorly due to differences in calibration and/or inadvertent detection of interfering substances by the immunoassays. Standardization efforts are underway, but recent studies indicate that accuracy remains an issue. METHODS: This study compares the results from four independently developed and validated LC-MS/MS assays for total testosterone. The calibration for each assay was verified using National Institute of Standards and Technology Standard Reference Material 971. RESULTS: Initially, one of the four assays had a mean percent difference of +11.44%, compared to the All Method Mean, but following re-verification of all five non-zero calibrator concentrations with the NIST SRM 971, the mean percent difference decreased to -4.88%. Subsequently, the agreement between all four assays showed a mean bias of <5% across the range of all testosterone concentrations (0.13-38.10 nmol/L; 3.7-1098 ng/dL), including at low concentrations of <1 nmol/L (<29 ng/dL). CONCLUSIONS: Excellent agreement between four independently developed LC-MS/MS assays demonstrates that harmonization using standard reference material is attainable. However, as we found in this study, to ensure accurate calibration it is critical to validate the concentrations of new lots of calibrators.

10.
Clin Lab Med ; 38(3): 527-537, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30115396

RESUMO

This article describes the need for, stratifies the complexity of, and proposes detailed lists of training competencies for diagnostic laboratory personnel using quantitative liquid chromatography-tandem mass spectrometry (LC-MS/MS) for patient care. Although quantitative LC-MS/MS is evolving toward greater automation with less need for technical expertise, gaps remain in resources for training and assessment.


Assuntos
Cromatografia Líquida , Pessoal de Laboratório Médico/educação , Ciência de Laboratório Médico/educação , Ciência de Laboratório Médico/organização & administração , Espectrometria de Massas em Tandem , Competência Clínica , Humanos , Pessoal de Laboratório Médico/normas
11.
JAMA ; 298(4): 413-22, 2007 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-17652295

RESUMO

CONTEXT: Past studies of the efficacy of hip protectors to prevent hip fracture in nursing home residents have had conflicting results, possibly due to potential biases from clustered randomization designs and modest adherence to intervention. OBJECTIVE: To determine whether an energy-absorbing and energy-dispersing hip protector would reduce the risk of hip fracture when worn by nursing home residents. DESIGN, SETTING, AND PARTICIPANTS: Multicenter, randomized controlled clinical trial in which 37 nursing homes were randomly assigned to having residents wear a 1-sided hip protector on the left or right hip. Participants were 1042 nursing home residents (mean [SD] aged 85 [7] years; 79% women) who consented and adhered to the hip protector use during a 2-week run-in period and were enrolled. Participating facilities were in greater Boston, Massachusetts, St Louis, Missouri, and Baltimore, Maryland from October 2002 to October 2004. Mean duration of participation for nursing home residents was 7.8 months. None were withdrawn because of adverse effects. INTERVENTION(S): Undergarments with a 1-sided hip protector made of a 0.32-cm outer layer of polyethylene (2.7 kg/m3) backed by a hard high-density polyethylene shield (0.95 cm) that was backed by 0.9 kg/m3 of 1.27-kg ethylene vinyl acetate foam. Each facility was visited 3 times per week to assess adherence and provide staff support. MAIN OUTCOME MEASURE: Adjudicated hip fracture occurrences on padded vs unpadded hips. RESULTS: After a 20-month follow-up (676 person-years of observation), the study was terminated due to a lack of efficacy. The incidence rate of hip fracture on protected vs unprotected hips did not differ (3.1%; 95% confidence interval [CI], 1.8%-4.4% vs 2.5%; 95% CI, 1.3%-3.7%; P = .70). For the 334 nursing home residents with greater than 80% adherence to hip protector use, the incidence rate of hip fracture on protected vs unprotected hips did not differ (5.3%; 95% CI, 2.6%-8.8% vs 3.5%; 95% CI, 1.3%-5.7%; P = .42). Overall adherence was 73.8%. CONCLUSIONS: In this clinical trial of an energy-absorbing/shunting hip protector conducted in US nursing homes, we were unable to detect a protective effect on the risk of hip fracture, despite good adherence to protocol. These results add to the increasing body of evidence that hip protectors, as currently designed, are not effective for preventing hip fracture among nursing home residents. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00058864.


Assuntos
Fraturas do Quadril/prevenção & controle , Instituição de Longa Permanência para Idosos , Casas de Saúde , Roupa de Proteção , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino
13.
J Appl Lab Med ; 2(1): 33-46, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-33636954

RESUMO

BACKGROUND: The advantage of LC-MS/MS for analyzing serum testosterone in female, pediatric, and hypogonadal male patient samples is well accepted (J Clin Endocrinol Metab 2010;95:4542-8). However, many clinical laboratories still use testosterone immunoassays because of the technical challenges of LC-MS/MS (Clin Chem 2010;56:1234-44). Although LC-MS/MS has been shown to have better accuracy and specificity than immunoassay, better reproducibility has been more elusive because of the complexities of sample preparation (Clin Chem 2008;54:1290-7; Rev Endocr Metab Disord 2013;14:185-205). METHODS: We evaluated replacing automated immunoassay with LC-MS/MS for all testosterone analyses at the University of California San Diego Health System Center for Advanced Laboratory Medicine. We used a novel extraction media, AC Extraction Plate™ (AC Plate), from Tecan Schweiz with automated liquid handling for LC-MS/MS sample preparation. We modified the existing vendor application and validated the method for matrix effect, recovery, precision, trueness [accuracy relative to certified reference material (CRM)], specificity, reportable range, sample stability, and correlation with other methods. RESULTS: Method performance was excellent, with a reportable range of 4-1560 ng/dL (0.14-54.13 nmol/L), between-day CV <6%, mean accuracy for CRM of <4.0% bias, no interference from hemolysis, icterus, lipemia, serum separator tube gel, or common steroids/metabolites, and mean bias of 1.3% vs 4 other LC-MS/MS testosterone methods. A retrospective analysis of calibration stability suggests that sparse and/or historical calibration is feasible for routine use. CONCLUSIONS: We conclude that automated extraction with the AC Plate and a focus on robustness during method development delivered ease of use and method performance consistent with adopting LC-MS/MS for all testosterone testing.

14.
J Anal Toxicol ; 30(2): 106-11, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16620541

RESUMO

OxyContin, a controlled-release formulation of oxycodone, is increasingly abused. Monitoring patient compliance by urine drug testing may deter illegal diversion of OxyContin. Two urine immunoassays were evaluated with a 100 ng/mL cutoff for oxycodone. The Microgenics Corporation Oxycodone DRI on the Bayer ADVIA 1650 and a point-of-care (POC) immunoassay, Monitect Oxycodone POC from Branan Medical Corporation, were compared to gas chromatography-mass spectrometry (GC-MS) with a detection limit of 50 ng/mL free oxycodone. Between-day precision for DRI yielded coefficients of variation from 3.9% to 7.0% at 75 and 125 ng/mL. Fifty-two positive and 52 negative urines were tested. The DRI had a 100% agreement with GC-MS. Two positive specimens had free oxycodone < 50 ng/mL, but oxycodone metabolites, oxymorphone and oxycodone glucuronide > 100 ng/mL, were identified by GC-MS analysis. The POC assay had two false positives and 15 indeterminate (+/-) results. Codeine or hydrocodone was present in all but one of these samples. There was no interference with DRI from morphine, codeine, hydrocodone, hydromorphone, dihydrocodeine, or 6-monoacetyl morphine. Four-hundred and ninety urine samples were subsequently tested with DRI to estimate the oxycodone-positive rate at our hospital, and 47 (9.4%) were positive. The confirmation rate with GC-MS for free oxycodone, not including metabolites, was 93%. The Microgenics DRI offers good performance for oxycodone urine testing and is a better choice for the clinical laboratory than the POC assay. Confirmation of screened positive samples requires a method that can detect total oxycodone and oxymorphone.


Assuntos
Técnicas de Laboratório Clínico , Cromatografia Gasosa-Espectrometria de Massas , Imunoensaio/métodos , Entorpecentes/urina , Oxicodona/urina , Detecção do Abuso de Substâncias/métodos , Calibragem , Medicina Legal/métodos , Humanos , Entorpecentes/imunologia , Oxicodona/imunologia , Sistemas Automatizados de Assistência Junto ao Leito , Reprodutibilidade dos Testes
15.
J Anal Toxicol ; 30(8): 570-5, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17132254

RESUMO

Confirmation of opioids in urine samples of clinical patients requires liberation of opioids from their glucuronide conjugates. Both acid hydrolysis and enzyme hydrolysis using beta-glucuronidase from various sources have been reported, with the latter approach prevailing in most clinical toxicology laboratories. The goal of this study was to compare the efficiency of acid versus different enzyme hydrolysis methods in recovering morphine and common semisynthetic opioids from glucuronide standards and 78 patient urine samples that were screened positive for opioids as a class. Specimens were analyzed with a validated gas chromatography-mass spectrometry (GC-MS) procedure. With the exception of oxycodone, the results indicated that the majority of opioids tested were extensively glucuronide-conjugated in urine. Significantly, acid hydrolysis liberated > 90% of morphine and hydromorphone from their glucuronide standards but enzyme hydrolysis had lower and variable efficiency, depending on the opiate type and the enzyme source. In patient specimens, much higher concentrations of free codeine, morphine, hydromorphone, and oxymorphone were obtained with acid hydrolysis than with various enzyme methods. Incomplete hydrolysis using beta-glucuronidase could lead to false-negative results for many opioids when urine is tested for drugs of abuse. We conclude that acid hydrolysis is the method of choice for GC-MS confirmation of urine opioids.


Assuntos
Analgésicos Opioides/urina , Glucuronidase/química , Preparações Farmacêuticas/urina , Analgésicos Opioides/química , Analgésicos Opioides/classificação , Reações Falso-Negativas , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Ácido Clorídrico/química , Hidrólise , Preparações Farmacêuticas/química
16.
J Anal Toxicol ; 39(9): 675-85, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26239972

RESUMO

Currently, the use of time of flight (TOF)-mass spectrometry (MS) in quantitative analysis of small molecules is rare. Recently, the quantitative performance of TOF mass analyzers has improved due to the advancements in TOF technology. We evaluated a Q-TOF-MS in different modes, i.e., Q-TOF-full scan (Q-TOF-FS), Q-TOF-enhanced-full scan (Q-TOF-En-FS), MS(E), Q-TOF-targeted (Q-TOF-TGT), Q-TOF-enhanced-targeted (Q-TOF-En-TGT), and compared their quantitative performance against a unit resolution LC-MS-MS (tandem quadrupole) platform. The five modes were investigated for sensitivity, linearity, signal-to-noise ratio, recovery and precision using 11-nor-9-carboxy-Δ(9)-tetrahydrocannabinol (THC-COOH) as a model compound in electrospray ionization (ESI) with negative polarity. Preliminary studies indicated that Q-TOF-FS mode was the least linear and precise; hence, it was eliminated from further investigation. Total imprecision in remaining four modes was <10%. The Q-TOF-En-FS and Q-TOF-En-TGT showed better signal intensity than their respective modes without enhancement. Overall, peak signal intensity was the highest in MS(E) mode, whereas the signal-to-noise ratio was the best in the Q-TOF-En-TGT mode. Relatively, MS(E) and Q-TOF-En-TGT modes were the best overall performers compared with the other modes. Both MS(E) and Q-TOF-En-TGT modes showed excellent precision (coefficient of variation <6%), patient correlation (r > 0.99) and linearity (range, 5-455 ng/mL) for THC-COOH analysis when compared with LC-MS-MS. We also investigated the performance of the same four modes using methamphetamine in positive ESI. Quantitative data obtained by Q-TOF-En-TGT and MS(E), using both positive and negative ESI, suggest that these modes performed better than the other modes. While unit resolution LC-MS-MS remains the optimal technique for quantification, our data showed that Q-TOF-MS can also be used to quantify small molecules in complex biological specimens.


Assuntos
Dronabinol/análogos & derivados , Metanfetamina/urina , Espectrometria de Massas em Tandem/métodos , Calibragem , Cromatografia Líquida de Alta Pressão/métodos , Dronabinol/urina , Humanos , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Manejo de Espécimes
17.
Eur J Pharm Sci ; 15(2): 185-95, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11849916

RESUMO

A method was developed and validated for measuring the free fraction of nelfinavir in plasma employing equilibrium dialysis for the separation of free (unbound) drug and liquid chromatography/tandem mass spectrometry for quantitation. Nelfinavir, widely used to treat HIV infection, is a highly bound HIV protease inhibitor with the fraction bound in plasma being greater than 98%. Thus variations in the free fraction may be clinically important when interpreting total drug concentrations. Optimization of the method was carried out considering the influence of sample matrix and physicochemical and absorptive properties of nelfinavir. Nelfinavir free fraction averaged 0.41 +/- 0.094, 0.43 +/- 0.087 and 0.41 +/- 0.063% at nelfinavir plasma concentrations of 1000, 2000 and 3000 ng/ml, respectively. Free nelfinavir concentrations were underestimated with this assay by approximately 25% because of unavoidable losses to adsorption. However, the adsorptive loss was reproducible and consistent across the concentration range of the assay. Within-day and between-day precisions ranged from 6.0 to 9.4% and 15.2 to 27.3%, respectively. The lower limit of quantitation of the unbound concentration of nelfinavir was 1.0 ng/ml, permitting analysis of samples with total concentrations of nelfinavir in plasma that are > or = 400 ng/ml. This developed method proves reproducible and sensitive and its application to patient plasma samples is also reported.


Assuntos
Cromatografia Líquida/métodos , Diálise/métodos , Inibidores da Protease de HIV/sangue , Espectrometria de Massas/métodos , Nelfinavir/sangue , Adsorção , Calibragem , Fenômenos Químicos , Físico-Química , Humanos , Concentração de Íons de Hidrogênio , Estrutura Molecular , Ligação Proteica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
J Pharm Biomed Anal ; 31(5): 953-9, 2003 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-12684107

RESUMO

A sensitive and rapid liquid chromatography tandem mass spectrometry (LC-MS-MS) method has been developed to measure the levels of the HIV-1 non-nucleoside reverse transcriptase inhibitor nevirapine (NVP) in human plasma. The analyte and internal standard (IS) are isolated from plasma by a simple perchloric acid precipitation of plasma proteins followed by centrifugation. LC-MS-MS in positive mode used pairs of ions at m/z of 267/226 for NVP and 628/421 for the IS, respectively. Two linear calibration curves were established for quantitation of NVP with the low curve ranging from 25 to 1000 ng/ml and the high curve ranging from 1000 to 10,000 ng/ml. Mean inter- and intra-assay coefficients of variation (CVs) over the ranges of the two standard curves were less than 10%. The overall recovery of NVP was 92.4%.


Assuntos
Fármacos Anti-HIV/sangue , Nevirapina/sangue , Inibidores da Transcriptase Reversa/sangue , Calibragem/normas , Cromatografia Líquida de Alta Pressão/métodos , Estabilidade de Medicamentos , Humanos , Espectrometria de Massas/métodos , Sensibilidade e Especificidade
19.
J Pharm Biomed Anal ; 30(3): 675-84, 2002 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-12367693

RESUMO

A sensitive and rapid liquid chromatography tandem mass spectrometry (LC-MS-MS) method has been developed to measure the levels of five HIV protease inhibitors nelfinavir (NFV), indinavir (IDV), ritonavir (RTV), saquinavir (SQV) and amprenavir (APV) in human plasma. The analytes and internal standard are isolated from plasma by a simple acetonitrile precipitation of plasma proteins followed by centrifugation. LC-MS-MS in positive mode used pairs of ions at m/z of 568.4/330.0, 614.3/421.2, 720.9/296.0, 671.1/570.2 and 505.9/245.0 for NFV, IDV, RTV, SQV and APV, respectively and 628/421 for the internal standard. Two 1/x weighted linear calibration curves for each analyte were established for quantitation with the low curve ranging from 5 to 1000 ng/ml and while the high curve ranging from 1000 to 10,000 ng/ml. Mean inter- and intra-assay coefficients of variation (CVs) over the ranges of the standard curves were less than 10%. The overall recovery of NFV, IDV, RTV, SQV and APV were 88.4, 91.4, 92.2, 88.9 and 87.6%, respectively.


Assuntos
Inibidores da Protease de HIV/sangue , Carbamatos , Cromatografia Líquida/métodos , Furanos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Inibidores da Protease de HIV/química , Indinavir/sangue , Indinavir/química , Nelfinavir/sangue , Nelfinavir/química , Ritonavir/sangue , Ritonavir/química , Saquinavir/sangue , Saquinavir/química , Sulfonamidas/sangue , Sulfonamidas/química
20.
J Clin Endocrinol Metab ; 99(4): 1171-9, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24423284

RESUMO

CONTEXT: An index case of a clinically euthyroid woman of South Asian descent was identified with discordant TSH results: undetectable TSH on our routine assay and normal TSH on an alternate assay. Low TSH concentrations due to functionally compromising TSH mutations have been reported. Here we describe a new phenomenon of functional TSH that is undetectable by 4 widely used US Food and Drug Administration (FDA)-approved TSH immunoassays marketed by a single vendor. OBJECTIVE: The purpose of this study was to identify additional cases and investigate the cause of the falsely undetectable TSH. DESIGN: All samples with TSH results of <0.01 µIU/mL were retested with a second TSH assay. Discordant samples were evaluated on up to 8 FDA-approved TSH immunoassays and the TSHß gene was sequenced. Retrospectively, thyroid function tests, diagnoses, and medications from 1.6 million individuals were analyzed. RESULTS: Out of approximately 2 million individuals, we have identified a cohort of 20 hypothyroid and euthyroid patients of shared ethnicity with falsely undetectable TSH (<0.01 µIU/mL) in 4 of 8 commercially available TSH assays. Half of these individuals were initially treated based on repeated falsely undetectable TSH values (7 euthyroid patients were treated with methimazole and 2 hypothyroid patients had doses of levothyroxine decreased). In all cases, a retrospective chart review revealed that clinical assessments and free T4 and total T3 results were inconsistent with the undetectable TSH results. Specific antibodies failing to detect TSH in these cases were identified in the 4 affected assays. A novel TSHß point mutation was identified. CONCLUSIONS: Our data suggest that these individuals have a previously unrecognized, functionally normal, TSH variant to which some monoclonal antibodies fail to bind. To assure appropriate patient management, clinicians and laboratorians need to be aware that certain TSH variants may be undetectable in some hyperselective TSH assays.


Assuntos
Erros de Diagnóstico , Hipotireoidismo/diagnóstico , Tireotropina/sangue , Adulto , Idoso , Povo Asiático/estatística & dados numéricos , California/epidemiologia , Estudos de Coortes , Erros de Diagnóstico/estatística & dados numéricos , Reações Falso-Negativas , Feminino , Humanos , Hipotireoidismo/sangue , Hipotireoidismo/epidemiologia , Imunoensaio/normas , Imunoensaio/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Testes de Função Tireóidea/normas , Testes de Função Tireóidea/estatística & dados numéricos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA