Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Acta Orthop Belg ; 78(6): 703-7, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23409563

RESUMO

Severely comminuted olecranon fractures are challenging injuries. Commonly used tension band wiring exerts excessive compressive forces causing olecranon shortening, joint incongruity and humeral trochlea subluxation. We report a retrospective study of 3 patients who underwent surgery for a severely comminuted olecranon fracture, with open reduction and fixation with a bridging rigid locking plate and intercalary tricortical structural iliac bone graft. Joint stability was restored allowing early mobilization and good functional outcome. Patients' mean age was 54 years. Mean follow-up was 23 months (range 19 to 27). Mean time to fusion was 14 weeks (range 11 to 18). Results were excellent/good in all three patients according the Broberg and Morrey scoring system, and Mayo Elbow Performance Index. Mean range of flexion was 115 degrees, with an average loss of 20 degrees of extension. Average pronation was 71 degrees, and supination 80 degrees.


Assuntos
Fraturas Cominutivas/cirurgia , Ílio/transplante , Olécrano/lesões , Fraturas da Ulna/cirurgia , Adulto , Idoso , Placas Ósseas , Feminino , Fraturas Cominutivas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Estudos Retrospectivos , Transplante Autólogo , Fraturas da Ulna/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA