Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Am J Infect Control ; 48(9): 1001-1008, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32151486

RESUMO

BACKGROUND: Short-term peripheral venous catheters-related bloodstream infections (PVCR-BSIs) rates have not been systematically studied in developing countries, and data on their incidence by number of device-days are not available. METHODS: Prospective, surveillance study on PVCR-BSI conducted from September 1, 2013 to May 31, 2019 in 204 intensive care units (ICUs), members of the International Nosocomial Infection Control Consortium (INICC), from 57 hospitals in 19 cities of India. We applied US INICC definition criteria and reported methods using the INICC Surveillance Online System. RESULTS: We followed 7,513 ICU patients for 296,893 bed-days and 295,795 short term peripheral venous catheter (PVC)-days. We identified 863 PVCR-BSIs, amounting to a rate of 2.91/1,000 PVC-days. Mortality in patients with PVC but without PVCR-BSI was 4.14%, and 11.59% in patients with PVCR-BSI. The length of stay in patients with PVC but without PVCR-BSI was 4.13 days, and 5.9 days in patients with PVCR-BSI. The micro-organism profile showed 68% of gram negative bacteria: Escherichia coli (23%), Klebsiella spp (15%), Pseudomonas aeruginosa (5%), and others. The predominant gram-positive bacteria were Staphylococcus aureus (10%). CONCLUSIONS: PVCR-BSI rates found in our ICUs were much higher than rates published from industrialized countries. Infection prevention programs must be implemented to reduce the incidence of PVCR-BSIs.


Assuntos
Infecções Relacionadas a Cateter , Infecção Hospitalar , Sepse , Infecções Relacionadas a Cateter/epidemiologia , Catéteres , Cidades , Infecção Hospitalar/epidemiologia , Hospitais , Humanos , Índia/epidemiologia , Controle de Infecções , Unidades de Terapia Intensiva , Estudos Prospectivos , Sepse/etiologia , Sepse/prevenção & controle
2.
Infect Control Hosp Epidemiol ; 37(2): 172-81, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26607300

RESUMO

OBJECTIVE: To report the International Nosocomial Infection Control Consortium surveillance data from 40 hospitals (20 cities) in India 2004-2013. METHODS: Surveillance using US National Healthcare Safety Network's criteria and definitions, and International Nosocomial Infection Control Consortium methodology. RESULTS: We collected data from 236,700 ICU patients for 970,713 bed-days Pooled device-associated healthcare-associated infection rates for adult and pediatric ICUs were 5.1 central line-associated bloodstream infections (CLABSIs)/1,000 central line-days, 9.4 cases of ventilator-associated pneumonia (VAPs)/1,000 mechanical ventilator-days, and 2.1 catheter-associated urinary tract infections/1,000 urinary catheter-days In neonatal ICUs (NICUs) pooled rates were 36.2 CLABSIs/1,000 central line-days and 1.9 VAPs/1,000 mechanical ventilator-days Extra length of stay in adult and pediatric ICUs was 9.5 for CLABSI, 9.1 for VAP, and 10.0 for catheter-associated urinary tract infections. Extra length of stay in NICUs was 14.7 for CLABSI and 38.7 for VAP Crude extra mortality was 16.3% for CLABSI, 22.7% for VAP, and 6.6% for catheter-associated urinary tract infections in adult and pediatric ICUs, and 1.2% for CLABSI and 8.3% for VAP in NICUs Pooled device use ratios were 0.21 for mechanical ventilator, 0.39 for central line, and 0.53 for urinary catheter in adult and pediatric ICUs; and 0.07 for mechanical ventilator and 0.06 for central line in NICUs. CONCLUSIONS: Despite a lower device use ratio in our ICUs, our device-associated healthcare-associated infection rates are higher than National Healthcare Safety Network, but lower than International Nosocomial Infection Control Consortium Report.


Assuntos
Infecções Relacionadas a Cateter/epidemiologia , Infecção Hospitalar/epidemiologia , Adulto , Comitês Consultivos , Idoso , Catéteres/efeitos adversos , Criança , Infecção Hospitalar/etiologia , Países em Desenvolvimento , Contaminação de Equipamentos , Equipamentos e Provisões , Feminino , Humanos , Índia/epidemiologia , Recém-Nascido , Controle de Infecções , Unidades de Terapia Intensiva , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Pneumonia Associada à Ventilação Mecânica/epidemiologia , Estudos Prospectivos , Vigilância de Evento Sentinela , Ventiladores Mecânicos/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA