Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
PLoS One ; 14(6): e0218248, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31216314

RESUMO

The advent of smartphones has advanced the use of embedded sensors to acquire various physiological information. For example, smartphone camera sensors and accelerometers can provide heart rhythm signals to the subjects, while microphones can give respiratory signals. However, the acquired smartphone-based physiological signals are more vulnerable to motion and noise artifacts (MNAs) compared to using medical devices, since subjects need to hold the smartphone with proper contact to the smartphone camera and lens stably and tightly for a duration of time without any movement in the hand or finger. This results in more MNA than traditional methods, such as placing a finger inside a tightly enclosed pulse oximeter to get PPG signals, which provides stable contact between the sensor and the subject's finger. Moreover, a smartphone lens does not block ambient light in an effective way, while pulse oximeters are designed to block the ambient light effectively. In this paper, we propose a novel diversity method for smartphone signals that reduces the effect of MNAs during heart rhythm signal detection by 1) acquiring two heterogeneous signals from a color intensity signal and a fingertip movement signal, and 2) selecting the less MNA-corrupted signal of the two signals. The proposed method has advantages in that 1) diversity gain can be obtained from the two heterogeneous signals when one signal is clean while the other signal is corrupted, and 2) acquisition of the two heterogeneous signals does not double the acquisition procedure but maintains a single acquisition procedure, since two heterogeneous signals can be obtained from a single smartphone camera recording. In our diversity method, we propose to choose the better signal based on the signal quality indices (SQIs), i.e., standard deviation of instantaneous heart rate (STD-HR), root mean square of the successive differences of peak-to-peak time intervals (RMSSD-T), and standard deviation of peak values (STD-PV). As a performance metric evaluating the proposed diversity method, the ratio of usable period is considered. Experimental results show that our diversity method increases the usable period 19.53% and 6.25% compared to the color intensity or the fingertip movement signals only, respectively.


Assuntos
Frequência Cardíaca/fisiologia , Coração/fisiologia , Monitorização Fisiológica , Smartphone , Algoritmos , Dedos/fisiologia , Humanos , Movimento (Física) , Oximetria/métodos , Processamento de Sinais Assistido por Computador , Máquina de Vetores de Suporte
2.
IEEE Access ; 6: 60498-60512, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-31263653

RESUMO

Photoplethysmography (PPG) is a technique to detect blood volume changes in an optical way. Representative PPG applications are the measurements of oxygen saturation, heart rate, and respiratory rate. However, PPG signals are sensitive to motion and noise artifacts (MNAs) especially when they are obtained from smartphone cameras. Moreover, PPG signals are different among users and each individual's PPG signal has a unique characteristic. Hence, an effective MNA detection and reduction method for smartphone PPG signals, which adapts itself to each user in a personalized way, is highly demanded. Here, a concept of the probabilistic neural network (PNN) is introduced to be used with the proposed extracted parameters. The signal amplitude, standard deviation of peak to peak time intervals and amplitudes, along with the mean of moving standard deviation, signal slope changes, and the optimal autoregressive (AR) model order are proposed for effective MNA detection. Accordingly, the performance of the proposed personalized algorithm is compared with conventional MNA detection algorithms. As performance metrics, we considered accuracy, sensitivity, and specificity. The results show that the overall performance of the personalized MNA detection is enhanced compared to the generalized algorithm. The average values of the accuracy, sensitivity and specificity of the personalized one are 98.07%, 92.6%, and 99.78%, respectively, while these are 89.92%, 84.21%, and 93.63% for the general one.

3.
IEEE J Emerg Sel Top Circuits Syst ; 8(2): 230-239, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30687580

RESUMO

We have recently found that our previously-developed atrial fibrillation (AF) detection algorithm for smartphones can give false positives when subjects' fingers or hands move, as we rely on proper finger placement over the smartphone camera to collect the signal of interest. Specifically, smartphone camera pulsatile signals that are obtained from normal sinus rhythm (NSR) subjects but are corrupted by motion and noise artifacts (MNAs) are frequently detected as AF. AF and motion-corrupted episodes have the similar characteristic that pulse-to-pulse intervals (PPIs) are irregular. We have developed an MNA-resilient smartphone-based AF detection algorithm that first discriminates and eliminates MNA-corrupted episodes in smartphone camera recordings, and then detects AF in MNA-free recordings. We found that MNA-corrupted episodes have highly-varying pulse slope, large turning point ratio, or large kurtosis values in smartphone signals compared to MNA-free AF and NSR episodes. We first use these three metrics for MNA discrimination and exclusion. Then, AF is detected in MNA-free signals using our previous algorithm. The capability to discriminate MNAs and AFs separately in smartphone signals increases the specificity of AF detection. To evaluate the performance of the proposed MNA-resilient AF algorithm, 99 subjects, including 88 study participants with AF at baseline and in NSR after electrical cardioversion as well as 11 participants with MNA-corrupted NSR, were recruited. Using iPhone 4S, 5S, and 6S models, we collected 2-minute pulsatile time series from each subject. The clinical results show that the accuracy, sensitivity and specificity of the proposed AF algorithm are 0.97, 0.98, 0.97, respectively, which are higher than those of the previous AF algorithm.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA