Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Environ Sci Technol ; 52(13): 7390-7398, 2018 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-29856617

RESUMO

Determining fluence is essential to derive the inactivation kinetics of microorganisms and to design ultraviolet (UV) reactors for water disinfection. UV light emitting diodes (UV-LEDs) are emerging UV sources with various advantages compared to conventional UV lamps. Unlike conventional mercury lamps, no standard method is available to determine the average fluence of the UV-LEDs, and conventional methods used to determine the fluence for UV mercury lamps are not applicable to UV-LEDs due to the relatively low power output, polychromatic wavelength, and specific radiation profile of UV-LEDs. In this study, a method was developed to determine the average fluence inside a water suspension in a UV-LED experimental setup. In this method, the average fluence was estimated by measuring the irradiance at a few points for a collimated and uniform radiation on a Petri dish surface. New correction parameters were defined and proposed, and several of the existing parameters for determining the fluence of the UV mercury lamp apparatus were revised to measure and quantify the collimation and uniformity of the radiation. To study the effect of polychromatic output and radiation profile of the UV-LEDs, two UV-LEDs with peak wavelengths of 262 and 275 nm and different radiation profiles were selected as the representatives of typical UV-LEDs applied to microbial inactivation. The proper setup configuration for microorganism inactivation studies was also determined based on the defined correction factors.


Assuntos
Raios Ultravioleta , Purificação da Água , Desinfecção , Viabilidade Microbiana , Microbiologia da Água
2.
Nat Methods ; 8(7): 581-6, 2011 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-21602799

RESUMO

Heterogeneity in cell populations poses a major obstacle to understanding complex biological processes. Here we present a microfluidic platform containing thousands of nanoliter-scale chambers suitable for live-cell imaging studies of clonal cultures of nonadherent cells with precise control of the conditions, capabilities for in situ immunostaining and recovery of viable cells. We show that this platform mimics conventional cultures in reproducing the responses of various types of primitive mouse hematopoietic cells with retention of their functional properties, as demonstrated by subsequent in vitro and in vivo (transplantation) assays of recovered cells. The automated medium exchange of this system made it possible to define when Steel factor stimulation is first required by adult hematopoietic stem cells in vitro as the point of exit from quiescence. This technology will offer many new avenues to interrogate otherwise inaccessible mechanisms governing mammalian cell growth and fate decisions.


Assuntos
Técnicas de Cultura de Células/métodos , Células-Tronco Hematopoéticas/citologia , Técnicas Analíticas Microfluídicas/métodos , Análise Serial de Tecidos , Adulto , Técnicas de Cultura de Células/instrumentação , Proliferação de Células , Ensaios de Triagem em Larga Escala , Humanos , Técnicas Analíticas Microfluídicas/instrumentação
3.
Water Res ; 249: 120972, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38091699

RESUMO

In this study, the first of its kind, a solid-phase fluorescence sensing platform was developed to quantify contaminants in water. ZnO quantum dots (QDs) were combined with molecularly imprinted polymers (MIPs) to form fluorescence sensing materials. Solid sensing layers were formed via a straightforward spin-coating method, which demonstrated a strong attachment to the sensor substrate while maintaining the integrity of the sensing materials. The developed sensing platform comprised a portable fluorescence detector to measure fluorescence intensity, instead of traditional fluorescence spectroscopy. The solid sensing platform was first tested with 2,4-dichlorophenoxyacetic acid (2,4-D), demonstrating high sensitivity (0.0233) and a very strong correlation (0.98) between the target molecule concentration and sensor signal. Further, the sensing platform was successfully adapted to measure a substance with a different molecular mass and chemical structure, the algae toxin microcystin-LR (MCLR); this demonstrated the sensor's versatility in quantifying target molecules. Tap water samples spiked with MCLR were also used to test the sensor's practical application. Finally, the working mechanism of the sensing platform was established, and the key information for using the sensor to measure various contaminants was determined. With its high performance, broad applicability, and ease of use, the developed platform provides a suitable basis for lab-on-chip image-based sensing devices for environmental monitoring.


Assuntos
Herbicidas , Impressão Molecular , Pontos Quânticos , Materiais Inteligentes , Água , Pontos Quânticos/química , Espectrometria de Fluorescência/métodos , Impressão Molecular/métodos
4.
Talanta ; 280: 126668, 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39128311

RESUMO

Determining the concentration of biomarkers offers insights into the health condition and performance of the body. The majority of the biosensors applied to measuring biomarkers in biological fluids are electrochemical bases; however, these biosensors suffer from several key drawbacks. These include utilizing complex sensing materials to obtain desirable analytical performance, which prevents their practical application; and operation at a relatively high potential, which leads to inaccurate measurements due to the undesired oxidation of non-target molecules. A novel photo-induced chemiresistive biosensor is introduced here that addresses these challenges. A UV-induced ZnO nanorod (NR) chemiresistive biosensor is developed and applied to monitoring lactate and glucose, as model biomarkers in sweat. The detection mechanism of lactate based on its interaction with ZnO NRs is proposed. Furthermore, the effect of the electrode design and operating parameters, including irradiance, radiation wavelength, and applied potential, are evaluated. The highest response, the shortest response time, and complete recovery are obtained at 5.6 mW/cm2 irradiance of 365 nm and 0.1 V potential. The results indicate that the developed transduction platform utilizing a simple sensing layer is a promising technique with excellent analytical performance for detecting different biomarkers, thereby paving the way toward the emergence of photo-induced chemiresistive biosensors for real-life applications.

5.
Environ Sci Pollut Res Int ; 31(4): 5847-5865, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38129726

RESUMO

Cyanide and heavy metals pose significant risks as contaminants in certain industrial effluents. This study aims to concurrently eliminate cyanide and specific heavy metals from synthetic wastewater resembling gold processing effluent, employing an improved electrocoagulation method incorporating ozone and UV-LED. The investigation delves into the effects of pH, electrode type, current density, reaction time, and ozonation. The findings revealed notable removal efficiencies: 98% for cyanide, 76% for nickel, 85% for copper, and 84% for zinc when utilizing a stainless steel electrode as the cathode. Optimal removal rates were achieved at 94% for cyanide, 93% for copper, 92% for zinc, and 83% for nickel, employing the UV-LED-ozone technique with an ozonation flow rate of 4 mg/s at pH = 10. Notably, when Al-Gr-SS-Fe electrodes and a current of 15 mA/cm2 were applied, these removal efficiencies were observed. Therefore, the most favorable conditions for the concurrent removal of pollutants from synthetic wastewater involved maintaining a pH of 10, utilizing SS-Fe as anode and Al-Gr as cathode electrodes, and employing a current density of 15 mA/cm2. The addition of ozonation with a flow rate of 4 mg/s, along with UV-LED, further enhanced the removal process. In summary, it can be inferred that the enhanced electrocoagulation method outperformed conventional electrocoagulation, leading to increased elimination of cyanide and selected heavy metals.


Assuntos
Metais Pesados , Ozônio , Poluentes Químicos da Água , Águas Residuárias , Cobre , Níquel , Zinco , Eletrocoagulação/métodos , Eletrodos , Cianetos , Eliminação de Resíduos Líquidos/métodos , Resíduos Industriais
6.
Chemosphere ; 328: 138593, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37023896

RESUMO

The utilization of membranes in the water industry has been growing rapidly; however, the technology still experiences problems with fouling. A potential solution is to immobilize photocatalyst particles on the surface of the membranes to encourage in situ degradation of the organic contaminants contributing to the fouling. In this study, we developed a photocatalytic membrane (PM) by coating a silicon carbide membrane with Zr/TiO2 sol. The performance of the PM in degrading different concentrations of humic acid was evaluated comparatively under UV irradiation of two wavelengths, 275 and 365 nm. The results indicated that (i) the PM achieved high levels of humic acid degradation, (ii) the photocatalytic activity of the PM reduced the formation of fouling and hence the loss of permeability, (iii) the formation of fouling was reversible; no trace of fouling was observed after cleaning, and (iv) the PM showed high durability during multiple rounds of operation.


Assuntos
Substâncias Húmicas , Poluentes Químicos da Água , Raios Ultravioleta , Água , Poluentes Químicos da Água/análise , Titânio , Catálise
7.
Water Res ; 230: 119581, 2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36638732

RESUMO

We developed and studied one of the first high-flow UV-LED water disinfection reactors applicable to point-of-entry (POE) water disinfection. A multiphysics computational model was created to predict the performance of UV reactor design concepts by modeling the synergic effect of radiation, hydrodynamics, and the inactivation kinetics of microorganisms. The geometrical optics that describe light propagation in terms of rays were employed to model the radiation profile of multiple UV-LEDs with optical components in complex reactor geometries, the first account of such an approach. The computational solution of the mass, momentum, and species equations was applied to model the hydrodynamics and kinetics. We designed a reactor through a detailed computational study of the optical and hydrodynamic performance of various design strategies. Highly efficient UV fluence distribution in the reactor was achieved by creating nearly collimated UV radiation beams across the reactor and managing the hydrodynamics using a flow distributor. We fabricated a prototype of the optimized reactor design for experimental studies. Biodosimetry tests were conducted for various flow rates and UV transmittances (UVTs), and the experimental results were compared with the model predictions. The design, which employed 14 UV-LEDs assembled over custom-made optical modules, resulted in a reduction equivalent dose (RED) of 65 mJ/cm2 at a flow rate of 20 liters per minute (LPM) while consuming about 50 W energy. This reactor design required only 0.05 W radiant power per LPM flow rate to achieve an NSF Class A UV dose equivalent of 40 mJ/cm2. The findings of this study provide insights into UV-LED reactor development strategies as well as the creation and application of reactor virtual prototyping tools for designing and optimizing highly efficient UV-LED reactors.


Assuntos
Purificação da Água , Purificação da Água/métodos , Hidrodinâmica , Cinética , Raios Ultravioleta , Desinfecção/métodos
8.
J Environ Chem Eng ; 11(3): 110040, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37197715

RESUMO

Microplasma UV lamps have recently emerged as viable excimer-based sources of UV radiation, garnering significant attention during the recent COVID-19 pandemic for their use in disinfection applications because of their ability to emit human-safe far-UVC (200-240 nm) spectrums. An accurate model to simulate the radiation profile of microplasma UV lamps is of paramount importance to develop efficient microplasma lamp-implemented systems. We developed a 3D numerical model of microplasma UV lamps using the ray optics method. The simulation results for lamp irradiance and fluence rate were experimentally validated with standard optical radiometry and actinometry measurements, respectively. To improve the optical efficiency of microplasma lamps, an in-depth analysis of radiation behavior inside the standard commercially available lamp was performed using the geometrical optics method, and several potential scenarios were explored. A 2D modeling of an individual microcavity indicated that the current common lamp design can be significantly improved by preventing radiation loss, and small modifications in optical design can greatly increase the energy performance of the system. Based on the findings of this study, several virtual design concepts were proposed, and their performances were numerically compared with that of the original design of commercial microplasma lamps. The developed model can potentially be integrated with hydrodynamic and kinetic models for the virtual prototyping of complex photoreactors operating with UV microplasma lamps.

9.
Chemosphere ; 292: 133353, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34942211

RESUMO

The degradation of organic contaminants is typically achieved by exposure of hydrogen peroxide (H2O2) containing influent to ultraviolet (UV) lamps as the source of radiation that can convert H2O2 to hydroxyl radicals (·OH), which oxidize organic pollutants. However, two factors prevent this process from being scaled down: the need to introduce H2O2, which requires special handling, and the use of bulky UV lamps, which have a high electric power consumption. In this work, an electrochemical cell was developed for the efficient in situ generation of H2O2 from water and atmospheric oxygen in a process called a two-electron oxygen reduction reaction (2e-ORR), so that the external addition of H2O2 is no longer needed. Moreover, the electrochemical cell was equipped with ultraviolet light-emitting diodes (UV-LEDs) to convert H2O2 to ·OH. The reactor exhibited a current efficiency of ∼90% for the H2O2 production at a flow rate of 50 mL min-1. The degradation of 2,4-dichlorophenoxyacetic acid (2,4-D) was studied at 277 nm based on different operational parameters, such as UV fluence rate, initial concentration, and initial pH. A high degradation of >70% was obtained at a UV output of 900 mW. Our approach, the first of its kind, has novel features applied, including: optimal radiation distribution in the reactor by applying a new UV source, UV-LEDs that offer much more control for the radiation profile in the reaction system compared to traditional UV lamps, controlled hydrodynamics by implementing special flow channels to provide a more uniform residence time and offer enhanced mixing, and integrating UV reactor and electrochemical cell in a single unit which could lead to superior performance and space efficiency of the device. These features make the device very suitable for point-of-use (POU) water treatment applications to eliminate both microbial and chemical contaminants.


Assuntos
Poluentes Químicos da Água , Purificação da Água , Peróxido de Hidrogênio , Radical Hidroxila , Oxirredução , Raios Ultravioleta
10.
RSC Adv ; 12(7): 4240-4252, 2022 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-35425407

RESUMO

In photocatalytic water splitting, fluidization is known to minimize the adverse effects of mass-transfer, poor radiation distribution, parasitic back-reactions and photocatalyst handling difficulties, which limit the scalability of immobilized-film and suspended slurry photocatalysts. Fluidization of one-dimensional TiO2 photocatalyst particles, such as nanorods, -wires and -ribbons, is highly desired as it further enhances the efficiency of photocatalytic reaction, due to their peculiar photo-electrochemical characteristics that result in more effective separation of photo-generated charges and absorption of photons. However, the harsh physical environment of a fluidized bed reactor does not readily allow for nanostructured TiO2 photocatalysts, as the fine features would be quickly removed from the particle surface. Here, we propose a scalable method for fabrication of rutile TiO2 nanorods on porous glass beads as a 3D protective substrate to reduce the attrition rate caused by fluidization. The quality of the synthesized nanorod films was optimized through controlling a growth quality factor, R q, allowing for good quality films to be grown in different batch amounts and different hydrothermal reactor sizes. The utilization of porous glass beads substrate has reduced the attrition rate, and the protective features of the particles reduced the rate of attrition by an order of magnitude, compared to a particulate photocatalyst, to near negligible levels. Such considerably reduced attrition makes the as-developed porous glass beads supported rutile TiO2 nanorods a viable fluidizable photocatalyst candidate for various applications, including water splitting and degradation of organic compounds.

11.
Biosens Bioelectron ; 174: 112830, 2021 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-33339696

RESUMO

To date, health organizations and countries around the world are struggling to completely control the spread of the coronavirus disease 2019 (COVID-19). Scientists and researchers are developing tests for the rapid detection of individuals who may carry the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), while striving to find a suitable vaccine to immunize healthy individuals. As there are clinically reported cases of asymptomatic carriers of SARS-CoV-2, fast and accurate diagnosis plays an important role in the control and further prevention of this disease. Herein, we present recent technologies and techniques that have been implemented for the diagnosis of COVID-19. We summarize the methods created by different research institutes as well as the commercial devices and kits developed by companies for the detection of SARS-CoV-2. The description of the existing methods is followed by highlighting their advantages and challenges. Finally, we propose some promising techniques that could potentially be applied to the detection of SARS-CoV-2, and tracing the asymptomatic carriers of COVID-19 rapidly and accurately in the early stages of infection, based on reviewing the research studies on the detection of similar infectious viruses, especially severe acute respiratory syndrome (SARS) coronavirus, and Middle East respiratory syndrome (MERS) coronavirus.


Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , SARS-CoV-2 , Inteligência Artificial , Técnicas Biossensoriais , COVID-19/prevenção & controle , Teste para COVID-19/instrumentação , Humanos , Dispositivos Lab-On-A-Chip , Tomografia Computadorizada por Raios X
12.
Nanomaterials (Basel) ; 10(12)2020 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-33327442

RESUMO

Binary and ternary oxynitride solid alloys were studied extensively in the past decade due to their wide spectrum of applications, as well as their peculiar characteristics when compared to their bulk counterparts. Direct bottom-up synthesis of one-dimensional oxynitrides through solution-based routes cannot be realized because nitridation strategies are limited to high-temperature solid-state ammonolysis. Further, the facile fabrication of oxynitride thin films through vapor phase strategies has remained extremely challenging due to the low vapor pressure of gaseous building blocks at atmospheric pressure. Here, we present a direct and scalable catalytic vapor-liquid-solid epitaxy (VLSE) route for the fabrication of oxynitride solid solution nanowires from their oxide precursors through enhancing the local mass transfer flux of vapor deposition. For the model oxynitride material, we investigated the fabrication of gallium nitride and zinc oxide oxynitride solid solution (GaN:ZnO) thin film. GaN:ZnO nanowires were synthesized directly at atmospheric pressure, unlike the methods reported in the literature, which involved multiple-step processing and/or vacuum operating conditions. Moreover, the dimensions (i.e., diameters and length) of the synthesized nanowires were tailored within a wide range.

13.
RSC Adv ; 10(25): 14906-14914, 2020 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-35497146

RESUMO

Surface modified gallium-zinc oxynitride solid solution exhibited outstanding stability and visible-light activity for water splitting. However, the considerable rate of photo-induced charge recombination and the low surface area of the bulk photocatalyst limited its performance. Here, an efficient technique is proposed for the synthesis of a nanoporous oxynitride photocatalyst and its graphene-hybridized material. The nanoporous oxynitride photocatalyst was prepared via a nanoscale solid-state route, using microwave irradiation as an intermolecular-state activation method, Ga3+/Zn2+ layered double hydroxide as an atomic-level uniform mixed-metal precursor, and urea as a non-toxic ammonolysis soft-template. The graphene-hybridized photocatalyst was fabricated using a facile electrostatic self-assembly technique. The photocatalytic activity of the synthesized graphene hybridized nanoporous oxynitride photocatalyst was systematically improved through shortening the majority-carrier diffusion length and enhancing the density of active hydrogen evolution sites within the quasi-three-dimensional nanostructure, reaching 7.5-fold sacrificial photocatalytic hydrogen evolution, compared to the conventional 1 wt% Rh-loaded oxynitride photocatalyst.

14.
Water Res ; 166: 115022, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31499450

RESUMO

The ultraviolet light emitting diode (UV-LED) has recently emerged as a new UV source. It offers design flexibility due to its small size and ability to alter its radiation profile. In view of the variety of design possibilities for a UV-LED reactor, a computational model could be of great value for simulating the reactor and providing insight into its performance. Given the UV-LED's ability to emit various radiation wavelengths and because it is a directional UV source, the challenges of simulation for UV-LEDs are greater than those for UV lamps, which typically have a single wavelength and an almost radial radiation profile. This study proposes a method of simulating UV-LED reactors in the Eulerian framework through the integration of the kinetic, hydrodynamic, and radiation models, representing UV-LED systems. Additionally, the concept of an ideal UV-LED system is proposed, which can provide insight into the efficiency of any UV-LED reactor design concept. The integrated model of reactor performance is evaluated through experimental studies of challenge organisms (e.g., Escherichia coli and MS2) in two UV-LED reactors under different operating conditions, including flow rates, flow regimes, radiant powers, and UV-LED configurations. The close agreement between the numerical predictions and experimental data demonstrates the ability of the proposed method to simulate UV-LED reactor performance.


Assuntos
Purificação da Água , Desinfecção , Escherichia coli , Cinética , Raios Ultravioleta
15.
Water Res ; 164: 114959, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31415967

RESUMO

The newly emerged microplasma UV radiating technology can be a viable alternative to conventional radiation sources for UV water treatment. The capability of the microplasma UV lamp to monochromatically irradiate various wavelengths with different pulsation frequencies in a flat form opens new pathways for the development of novel UV-based water purifiers. This study is the first to systematically examine the microplasma UV lamp and develop a robust experimental method and apparatus for its operation to study the kinetics of both microbial and chemical pollutant degradation. The microplasma UV lamp was characterized in terms of its radiation profile and the impact of operating parameters on the lamp radiant power output. It was shown to be an instant-on and fast stabilized source. The radiant power output was a linear function of the electrical current and was not influenced by the lamp operating temperature and intermittent on/off cycles. A protocol was developed for obtaining reliable kinetic data for UV-induced elimination of microorganisms and micropollutants. An experimental setup was proposed for the kinetic studies, where the characteristics of the incident irradiance of the lamp, including uniformity, collimation, and divergence, were quantitatively evaluated. In addition, the water factor (WF) for calculating the average fluence rate was redefined for both the transient and steady state conditions. This modification is essential to account for changes in the UV transmittance of the medium, which could be an important factor for kinetic study of chemical contaminants. Two studied cases of microbial direct inactivation and the chemical photo-initiated oxidation process in different setups, based on the developed protocol, confirmed the reproducibility of the fluence-based kinetic data independent of the reactor size. The proposed protocol can be applied to the kinetic study of the elimination of microbial and chemical contaminants using microplasma UV lamps of any size, power, and peak wavelength.


Assuntos
Purificação da Água , Água , Cinética , Reprodutibilidade dos Testes , Raios Ultravioleta
16.
Water Res ; 163: 114875, 2019 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-31344504

RESUMO

Recently, ultraviolet light-emitting diodes (UV-LEDs) have emerged as a new UV source, bringing flexibility for various UV wavelength combinations due to their unique feature of wavelength diversity. In this study, we investigated inactivation mechanisms of representative microorganisms at different wavelength combinations using UV-LEDs. Two types of indicator microorganisms were examined, namely Escherichia coli (E. coli) as a representative bacteria and bacteriophage MS2 as a representative virus. Different inactivation effects were observed, and the results for UVA pretreatment followed by UVC inactivation were particularly interesting. While a substantial shoulder in the E. coli UVC inactivation curve was observed, this was reduced by UVA pretreatment (365 nm) at 17 J/cm2. Further, 52 J/cm2 UVA eliminated the shoulder in the fluence-response curves, resulting in improved UVC (265 nm) inactivation of E. coli by over two orders of magnitude. No inactivation improvement was observed for MS2. Moreover, UVA pretreatment eliminated photoreactivation of E. coli but did not affect dark repair. Detailed investigation of inactivation mechanisms revealed that hydroxyl radicals (•OH) played a significant role in the effects of UVA pretreatment. This study demonstrated that •OH radicals were generated inside E. coli cells during UVA pretreatment, which accounted for the subsequent effects on E. coli. The impact of UVA pretreatment on E. coli inactivation and reactivation was mainly due to increased levels of •OH radicals in E. coli cells, impairing cell functions such as DNA self-repair.


Assuntos
Desinfecção , Escherichia coli , Bactérias , Levivirus , Raios Ultravioleta
17.
Sci Total Environ ; 665: 1103-1110, 2019 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-30893742

RESUMO

Ultraviolet light-emitting diode (UV-LED) is an emerging UV source with many special features due to the nature of semiconductor devices. One such feature is wavelength diversity that does not exist in conventional mercury based UV lamps, which provides opportunities to selectively combine multiple wavelengths for potentially additional effects by UV-LEDs. In this work, the inactivation of different microorganisms in water was investigated by UV-LEDs wavelength combinations. Various wavelength combinations, including simultaneous and sequential exposures, in different UV ranges such as UVC, UVB and UVA, were examined. These combinations were applied to the inactivation of indicator bacterium E. coli and coliphage MS2 in water. The results showed the effect of UV-LEDs multiple wavelengths depends on which wavelengths (UVC, UVB and UVA) are combined and the manner that different wavelengths (simultaneous, sequential) are used. Also, different microorganisms (bacteria, virus) respond differently to wavelength combinations. Combinations of UVC/UVB always achieved additive effect on microorganisms inactivation due to the same photochemical reaction induced by UVC/UVB on DNA. Combining UVA with UVC/UVB simultaneously or applying UVA after UVC/UVB reduced the inactivation of bacterium E. coli due to DNA repair and photoreactivation effect of UVA. However, applying extended UVA exposure before UVC significantly improved E. coli inactivation. For virus MS2 inactivation, only additive effect was observed under various wavelength combinations. This study presented a comprehensive work on UV-LEDs wavelength combinations, which is of significance on the application of UV-LEDs for water disinfection.


Assuntos
Desinfecção/métodos , Escherichia coli/efeitos da radiação , Levivirus/efeitos da radiação , Raios Ultravioleta , Eliminação de Resíduos Líquidos/métodos , Desinfecção/instrumentação , Eliminação de Resíduos Líquidos/instrumentação
18.
Water Res ; 122: 570-579, 2017 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-28628879

RESUMO

Tremendous improvements in semiconductor technology have made ultraviolet light-emitting diodes (UV-LEDs) a viable alternative to conventional UV sources for water treatment. A robust and validated experimental protocol for studying the kinetics of microorganism inactivation is key to the further development of UV-LEDs for water treatment. This study proposes a protocol to operate UV-LEDs and control their output as a polychromatic radiation source. In order to systematically develop this protocol, the results of spectral power distribution, radiation profile, and radiant power measurements of a variety of UV-LEDs are presented. A wide range of UV-LEDs was selected for this study, covering various UVA, UVB, and UVC wavelengths, viewing angles from 3.5° to 135°, and a variety of output powers. The effects of operational conditions and measurement techniques were investigated on these UV-LEDs using a specially designed and fabricated setup. Operating conditions, such as the UV-LED electrical current and solder temperature, were found to significantly affect the power and peak wavelength output. The measurement techniques and equipment, including the detector size, detector distance from the UV-LED, and potential reflection from the environment, were shown to influence the results for many of the UV-LEDs. The results obtained from these studies were analyzed and applied to the development of a protocol for UV-LED characterization. This protocol is presented as a guideline that allows the operation and control of UV-LEDs in any structure, as well as accurately measuring the UV-LED output. Such information is essential for performing a reliable UV-LED assessment for the inactivation of microorganisms and for obtaining precise kinetic data.


Assuntos
Purificação da Água , Cinética , Raios Ultravioleta
19.
Water Res ; 94: 341-349, 2016 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-26971809

RESUMO

Ultraviolet (UV) disinfection is an effective technology for the inactivation of pathogens in water and is of growing interest for industrial application. A new UV source - ultraviolet light-emitting diode (UV-LED) - has emerged in the past decade with a number of advantages compared to traditional UV mercury lamps. This promising alternative raises great interest in the research on application of UV-LEDs for water treatment. Studies on UV-LED water disinfection have increased during the past few years. This article presents a comprehensive review of recent studies on UV-LEDs with various wavelengths for the inactivation of different microorganisms. Many inconsistent and incomparable data were found from published studies, which underscores the importance of establishing a standard protocol for studying UV-LED inactivation of microorganisms. Different UV sensitivities to UV-LEDs and traditional UV lamps were observed in the literature for some microorganisms, which requires further investigation for a better understanding of microorganism response to UV-LEDs. The unique aspects of UV-LEDs improve inactivation effectiveness by applying LED special features, such as multiple wavelengths and pulsed illumination; however, more studies are needed to investigate the influencing factors and mechanisms. The special features of UV-LEDs offer the flexibility of novel reactor designs for a broad application of UV-LED reactors.


Assuntos
Desinfecção/métodos , Raios Ultravioleta , Microbiologia da Água , Purificação da Água/métodos , Água/química , Bactérias/efeitos da radiação , Bacteriófagos/efeitos da radiação
20.
Water Res ; 38(18): 3940-8, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15380984

RESUMO

The impacts of UV irradiation, gamma irradiation, and a combination of both on Escherichia coli inactivation in primary and secondary wastewater effluents were investigated. UV doses of 35 and 62 J/m(2) were required for a 1-log inactivation of E. coli in the primary and secondary wastewater samples, respectively. A gamma dose of 170 Gy (J/kg) was required for a 1-log inactivation of E. coli in both wastewater samples. Variation in gamma radiation dose rates did not have a significant impact on the extent of inactivation at a given total dose. Gamma irradiation of previously UV-irradiated samples indicated that particle-associated microorganisms, which are protected from UV, can be inactivated by ionizing radiation at a rate similar to that for free microorganism inactivation. An estimation of the energy required for disinfection indicated that, in general, the required energy and the energy cost for E. coli inactivation using ionizing radiation are considerably higher than those for UV radiation.


Assuntos
Escherichia coli/patogenicidade , Raios Ultravioleta , Purificação da Água/métodos , Desinfecção/métodos , Tamanho da Partícula , Eliminação de Resíduos Líquidos/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA