Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
1.
Sensors (Basel) ; 24(5)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38475162

RESUMO

An educational augmented reality auscultation system (EARS) is proposed to enhance the reality of auscultation training using a simulated patient. The conventional EARS cannot accurately reproduce breath sounds according to the breathing of a simulated patient because the system instructs the breathing rhythm. In this study, we propose breath measurement methods that can be integrated into the chest piece of a stethoscope. We investigate methods using the thoracic variations and frequency characteristics of breath sounds. An accelerometer, a magnetic sensor, a gyro sensor, a pressure sensor, and a microphone were selected as the sensors. For measurement with the magnetic sensor, we proposed a method by detecting the breathing waveform in terms of changes in the magnetic field accompanying the surface deformation of the stethoscope based on thoracic variations using a magnet. During breath sound measurement, the frequency spectra of the breath sounds acquired by the built-in microphone were calculated. The breathing waveforms were obtained from the difference in characteristics between the breath sounds during exhalation and inhalation. The result showed the average value of the correlation coefficient with the reference value reached 0.45, indicating the effectiveness of this method as a breath measurement method. And the evaluations suggest more accurate breathing waveforms can be obtained by selecting the measurement method according to breathing method and measurement point.


Assuntos
Realidade Aumentada , Estetoscópios , Humanos , Auscultação , Respiração , Expiração , Sons Respiratórios
2.
Eur Radiol ; 33(10): 6844-6851, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37552261

RESUMO

OBJECTIVES: To determine the impact of fat on the apparent T1 value of the liver using water-only derived T1 mapping. METHODS: 3-T MRI included 2D Look-Locker T1 mapping and proton density fat fraction (PDFF) mapping. T1 values of the liver were compared among T1 maps obtained by in-phase (IP), opposed-phase (OP), and Dixon water sequences using paired t-test. The correlation between T1 values of the liver on each T1 map and PDFF was assessed using Spearman correlation coefficient. The absolute differences between T1 value of the liver on Dixon water images and that on IP or OP images were also correlated with PDFF. RESULTS: One hundred sixty-two patients (median age, 70 [range, 24-91] years, 90 men) were retrospectively evaluated. The T1 values of the liver on each T1 map were significantly different (p < 0.001). The T1 value of the liver on IP images was significantly negatively correlated with PDFF (r = - 0.438), while the T1 value of the liver on OP images was slightly positively correlated with PDFF (r = 0.164). The T1 value of the liver on Dixon water images was slightly negatively correlated with PDFF (r = - 0.171). The absolute differences between T1 value of the liver on Dixon water images and that on IP or OP images were significantly correlated with PDFF (r = 0.606, 0.722; p < 0.001). CONCLUSION: Fat correction for the apparent T1 value by water-only derived T1 maps will be helpful for accurately evaluating the T1 value of the liver. CLINICAL RELEVANCE STATEMENT: Fat-corrected T1 mapping of the liver with the water component only obtained from the 2D Dixon Look-Locker sequence could be useful for accurately evaluating the T1 value of the liver without the impact of fat in daily clinical practice. KEY POINTS: • The T1 values of the liver on the conventional T1 maps are significantly affected by the presence of fat. • The apparent T1 value of the liver on water-only derived T1 maps would be slightly impacted by the presence of fat. • Fat correction for the apparent T1 values is necessary for the accurate assessment of the T1 values of the liver.


Assuntos
Fígado Gorduroso , Água , Masculino , Humanos , Idoso , Estudos Retrospectivos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Prótons
3.
Radiol Med ; 128(10): 1192-1198, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37606795

RESUMO

PURPOSE: To evaluate the image quality qualitatively and quantitatively, as well as apparent diffusion coefficient (ADC) values of modified reduced field-of-view diffusion-weighted magnetic resonance imaging (MRI) using spatially tailored two-dimensional radiofrequency pulses with tilted excitation plane (tilted r-DWI) based on single-shot echo planar imaging (SS-EPI) compared with full-size field-of-view DWI (f-DWI) using readout segmented (RS)-EPI in patients with rectal cancer. MATERIALS AND METHODS: Twenty-two patients who underwent an MRI for further evaluation of rectal cancer were included in this retrospective study. All MR images were analyzed to compare image quality, lesion conspicuity, and artifacts between f-DWI with RS-EPI and tilted r-DWI with SS-EPI. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and ADC values were also compared. The Wilcoxon signed-rank test or paired t test was performed to compare the qualitative and quantitative assessments. RESULTS: All image quality scores, except aliasing artifacts, were significantly higher (p < 0.01 for all) in tilted r-DWI than f-DWI with RS-EPI. CNR in tilted r-DWI was significantly higher than in f-DWI with RS-EPI (p < 0.01), while SNR was not significantly different. Regarding the ADC values, no significant difference was observed between tilted r-DWI and f-DWI with RS-EPI (p = 0.27). CONCLUSION: Tilted r-DWI provides a better image quality with fewer artifacts and higher rectal lesion conspicuity than f-DWI with RS-EPI, indicating the feasibility of this MR sequence in evaluating rectal cancer in clinical practice.


Assuntos
Imagem Ecoplanar , Neoplasias Retais , Humanos , Imagem Ecoplanar/métodos , Estudos Retrospectivos , Razão Sinal-Ruído , Neoplasias Retais/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Reprodutibilidade dos Testes
4.
J Magn Reson Imaging ; 55(4): 1234-1240, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34331482

RESUMO

BACKGROUND: To resolve drawbacks of navigator triggering (NT) three-dimensional (3D) magnetic resonance cholangiopancreatography (MRCP), several approaches were proposed to obtain 3D MRCP within a single breath-hold (BH). However, reduced field-of-view technique in the phase-encoding direction combined with two-dimensional spatially selective radiofrequency excitation pulses has not yet been applied to 3D BH MRCP. PURPOSE: To investigate the feasibility and the complementary value of 3D BH zoomed MRCP to conventional 3D NT MRCP in patients with branch duct intraductal papillary mucinous neoplasms (BD-IPMNs) of the pancreas. STUDY TYPE: Retrospective. POPULATION: A total of 221 patients (116 male and 105 female, median age 73 years) with BD-IPMNs. FIELD STRENGTH/SEQUENCE: 3.0 T/3D turbo spin echo ASSESSMENT: MR images were analyzed by three radiologists (R.M., H.O., M.T., with 1, 13, and 17 years of experience) to compare blurring and motion artifacts, background suppression, visualization of main pancreatic duct (MPD), conspicuity of BD-IPMN, and overall image quality. STATISTICAL TESTS: Wilcoxon-signed rank, Mann-Whitney U, chi-squared or Fisher's exact tests (P < 0.05). RESULTS: Image quality was significantly higher on 3D NT MRCP images than on 3D BH zoomed MRCP (median (interquartile range); background suppression, 4 (4-4) vs. 3 (3-4); visualization of MPD, 4 (3-4) vs. 4 (3-4), conspicuity of BD-IPMN, 4 (3-4) vs. 3 (3-4); and overall image quality, 3 (3-4) vs. 3 (3-3)). However, in 32 (14%) patients, 3D NT MRCP showed a score of 1 or 2 in overall image quality. Regarding the conspicuity of BD-IPMN, a conspicuity score of 1 or 2 was rendered in 31 (14%) patients in 3D NT MRCP group. Conversely, 3D BH zoomed MRCP showed a score of 3 or 4 in 29 (94%) of these 31 patients. DATA CONCLUSION: 3D BH zoomed MRCP plays a complementary role to 3D NT MRCP, and may improve the conspicuity of BD-IPMNs in patients with irregular breathing pattern. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY: Stage 2.


Assuntos
Neoplasias Intraductais Pancreáticas , Neoplasias Pancreáticas , Idoso , Suspensão da Respiração , Colangiopancreatografia por Ressonância Magnética/métodos , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Neoplasias Pancreáticas/diagnóstico por imagem , Estudos Retrospectivos
5.
J Magn Reson Imaging ; 54(6): 1902-1911, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34121262

RESUMO

BACKGROUND: The physiological flow patterns and the reciprocal relationship between pancreatic juice and bile excretion dynamics have not been clearly elucidated by imaging. PURPOSE: To assess the physiological flow patterns of bile and pancreatic juice simultaneously in order to clarify the pancreatobiliary flow dynamics using cine-dynamic magnetic resonance cholangiopancreatography (MRCP) with a spatial selective inversion recovery (IR) pulse. STUDY TYPE: Retrospective. POPULATION: A total of 85 patients with physiologically normal pancreatobiliary flow without ductal dilatation (normal group) and 19 patients with dilated pancreatic duct. FIELD STRENGTH/SEQUENCE: A 3 T, fast spin echo sequence with IR pulse to nullify the signal of static pancreatic juice and bile. ASSESSMENT: The frequency and secretion grade of the antegrade and reverse flow of the pancreatic juice and bile on cine-dynamic MRCP were visually evaluated. Additionally, the reciprocal relationship between pancreatic juice and bile flow was evaluated based on its flow patterns. STATISTICAL TESTS: Spearman's rank correlation coefficient analysis and the Kruskal-Wallis and Mann-Whitney U tests were used. P values of <0.05 were considered to indicate statistical significance. RESULTS: In the normal group, the antegrade pancreatic juice flow and no bile flow pattern was most frequently observed (29%), followed by the no pancreatic juice flow and no bile flow pattern (23%), the antegrade pancreatic juice flow and antegrade bile flow pattern (22%), and the no pancreatic juice flow and reverse bile flow pattern (9%). The flow of the pancreatic juice and bile were synchronized with each other in 47%, while they were not in 53%. In the dilated pancreatic duct group, the mean secretion grade of the antegrade bile and pancreatic juice flow was significantly lower than in the normal group. DATA CONCLUSION: Cine-dynamic MRCP with a spatially selective IR pulse can visualize the variations of the physiological flow patterns of bile and pancreatic juice including 53% of unsynchronized patterns. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY: Stage 5.


Assuntos
Colangiopancreatografia por Ressonância Magnética , Suco Pancreático , Bile , Dilatação Patológica , Humanos , Ductos Pancreáticos/diagnóstico por imagem , Estudos Retrospectivos
6.
J Magn Reson Imaging ; 54(3): 715-720, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33704860

RESUMO

BACKGROUND: Reduced field-of-view diffusion-weighted imaging (rDWI) with tilted two-dimensional radiofrequency (RF) excitation planes has not yet been applied to the imaging of the pancreas although the utility of this technique which allows the acquisition of high-quality images without aliasing artifacts in the phase-encoding direction has been evaluated for brain and spinal cord imaging. PURPOSE: To evaluate the visual image quality of the pancreas by tilting the excitation plane (tilted rDWI) in comparison to conventional DWI (cDWI) and rDWI without using the tilted excitation plane. STUDY TYPE: Retrospective. POPULATION: Thirty-two patients evaluated for suspected pancreatobiliary diseases. FIELD STRENGTH/SEQUENCE: Echo-planar imaging DWI (cDWI, rDWI, and tilted rDWI) acquired at 3 T. ASSESSMENT: Images from each DWI sequence were analyzed by five radiologists to compare image quality (conspicuity of pancreatic edges, interslice signal homogeneity, overall image quality, and conspicuity of focal pancreatic lesions) and artifacts (presence of blurring or ghosting artifacts, susceptibility artifacts, and aliasing artifact). STATISTICAL TESTS: Shapiro-Wilk test was performed to assess whether data were normally distributed. Friedman test followed by Bonferroni-adjusted Wilcoxon signed-rank test for post hoc analysis was performed to compare image quality and artifact scores. RESULTS: The mean scores for conspicuity of pancreatic edges (3.36 vs. 2.37), interslice signal homogeneity (3.14 vs. 2.81), presence of ghosting artifacts (3.32 vs. 2.66), susceptibility artifacts (3.06 vs. 2.30), and aliasing artifacts (3.90 vs. 2.34), and overall image quality (3.49 vs. 2.36) were significantly higher in the tilted rDWI than in the rDWI (P < 0.017 for all parameters). The conspicuity score for focal pancreatic lesions tended to be higher in tilted rDWI than in rDWI (2.44 vs. 2.00, P = 0.07). DATA CONCLUSION: Tilted rDWI had better image quality and reduced artifacts relative to cDWI and rDWI techniques in the pancreas. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY: Stage 2.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem Ecoplanar , Artefatos , Humanos , Imageamento por Ressonância Magnética , Pâncreas/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos
7.
Eur Radiol ; 31(12): 9022-9029, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34019129

RESUMO

OBJECTIVES: To evaluate the association between a sign and visceral pleural invasion (VPI) of peripheral non-small-cell lung cancer (NSCLC) that does not appear touching the pleural surface. METHODS: A total of 221 consecutive patients with NSCLC that did not appear touching the pleural surface, ≤ 3 cm in solid tumor diameter, and was surgically resected between January 2009 and December 2015 were included. We focused on the flat distortion of the tumor caused by an arch-shaped linear tag between the tumor and the pleura on CT and named it a bridge tag sign. We evaluated the associations between the clinicopathological features of the tumor, including the bridge tag sign, and VPI. We also evaluated the associations between histopathological findings and the bridge tag sign. The utility of the bridge tag sign in the diagnosis of VPI was statistically assessed. RESULTS: The bridge tag sign was observed in 48 (20.8%) patients. VPI was positive in 9 (4.1%) patients; among these, the bridge tag sign was positive in 8 patients. In multivariate analysis, a bridge tag sign was significantly associated with VPI. The bridge tag sign was associated with longer contact length of the pleura with the tumor and trapezoid type pleural retraction. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of the bridge tag sign in the diagnosis of VPI were 88.9%, 83.5%, 83.7%, 18.6%, and 99.4%, respectively. CONCLUSIONS: A bridge tag sign on CT might improve the accuracy of the prediction of VPI. KEY POINTS: • We present the bridge tag sign which is defined as a flat distortion of an NSCLC tumor by an arch-shaped linear tag between the tumor and chest wall or interlobar fissure. • The bridge tag sign was an independent predictive factor for visceral pleural invasion. • The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of the bridge tag sign in the diagnosis of visceral pleural invasion were 88.9%, 83.5%, 83.7%, 18.6%, and 99.4%, respectively.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/patologia , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Invasividade Neoplásica/patologia , Estadiamento de Neoplasias , Pleura/diagnóstico por imagem , Pleura/patologia , Prognóstico , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
8.
Radiol Med ; 125(1): 1-6, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31562581

RESUMO

PURPOSE: To evaluate the influence of fat deposition on T1 relaxation time of pancreatic parenchyma using dual-flip-angle T1 mapping with and without fat suppression. METHODS: Forty-five patients who underwent abdominal MR imaging including T1 mapping with dual-flip-angle method on 3T MRI were included. We measured T1 relaxation time of pancreatic parenchyma on the T1 map images with and without fat suppression. T1 relaxation time of bone marrow was also measured as a reference organ with abundant fat deposition. Fat signal fraction (FSF) was also measured at the same location as T1 map images. Then, the correlation between T1 relaxation time and FSF was assessed. RESULTS: T1 relaxation times of pancreatic parenchyma and bone marrow on the T1 map images without fat suppression showed significantly negative correlation with FSF (pancreas, r = - 0.394, P = 0.007; bone marrow, r = - 0.550, P < 0.001), while there were no significant correlations between them on the T1 map images with fat suppression. On the T1 map images without fat suppression, T1 relaxation times of pancreatic parenchyma as well as bone marrow in patients with FSF ≥ 10% were significantly shorter than those in patients with FSF < 10% (pancreas, P = 0.041; bone marrow, P = 0.005). Conversely, on the T1 map images with fat suppression, no significant differences in T1 relaxation times were found between two groups. CONCLUSION: T1 relaxation time of the pancreas on T1 mapping was influenced by the presence of fat deposition. Therefore, fat suppression technique in T1 mapping will be essential for evaluating T1 relaxation time of pancreatic parenchyma.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Pâncreas/diagnóstico por imagem , Pancreatopatias/diagnóstico por imagem , Técnica de Subtração , Idoso , Idoso de 80 Anos ou mais , Medula Óssea/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Pancreáticas/diagnóstico por imagem , Padrões de Referência , Estudos Retrospectivos , Fatores de Tempo
9.
Gan To Kagaku Ryoho ; 46(13): 2431-2433, 2019 Dec.
Artigo em Japonês | MEDLINE | ID: mdl-32156955

RESUMO

A questionnaire survey was conducted regarding the prognosis for pancreatic cancer at 8 major hospitals in Yamaguchi Prefecture. A total of 552 patients with pancreatic cancer who underwent radical surgery between 1997 and 2016 were identified. Five of them survived for more than 10 years. Among the 5 patients, none was treated with neoadjuvant chemotherapy: 4 underwent PD and 1 underwent DP-CAR. Two of them were treated with adjuvant chemotherapy. No complications occurred during their postoperative courses. All of them had no recurrence and survived. Here, we reported the longterm postoperative survival of patients with pancreatic cancer with literature review.


Assuntos
Neoplasias Pancreáticas , Protocolos de Quimioterapia Combinada Antineoplásica , Quimioterapia Adjuvante , Humanos , Terapia Neoadjuvante , Recidiva Local de Neoplasia , Pancreatectomia , Neoplasias Pancreáticas/terapia , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida
10.
Radiology ; 281(1): 129-39, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27115054

RESUMO

Purpose To determine the proportion of untreated Liver Imaging Reporting and Data System (LI-RADS) version 2014 category 2, 3, and 4 observations that progress, remain stable, or decrease in category and to compare the cumulative incidence of progression in category. Materials and Methods In this retrospective, longitudinal, single-center, HIPAA-compliant, institutional review board-approved study, 157 patients (86 men and 71 women; mean age ± standard deviation, 59.0 years ± 9.7) underwent two or more multiphasic computed tomographic (CT) or magnetic resonance (MR) imaging examinations for hepatocellular carcinoma surveillance, with the first examination in 2011 or 2012. One radiologist reviewed baseline and follow-up CT and MR images (mean follow-up, 614 days). LI-RADS categories issued in the clinical reports by using version 1.0 or version 2013 were converted to version 2014 retrospectively; category modifications were verified with another radiologist. For index category LR-2, LR-3, and LR-4 observations, the proportions that progressed, remained stable, or decreased in category were calculated. Cumulative incidence curves for progression were compared according to baseline LI-RADS category (by using log-rank tests). Results All 63 index LR-2 observations remained stable or decreased in category. Among 166 index LR-3 observations, seven (4%) progressed to LR-5, and eight (5%) progressed to LR-4. Among 52 index LR-4 observations, 20 (38%) progressed to a malignant category. The cumulative incidence of progression to a malignant category was higher for index LR-4 observations than for index LR-3 or LR-2 observations (each P < .001) but was not different between LR-3 and LR-2 observations (P = .155). The cumulative incidence of progression to at least category LR-4 was trend-level higher for index LR-3 observations than for LR-2 observations (P = .0502). Conclusion Observations classified according to LI-RADS version 2014 categories are associated with different imaging outcomes. (©) RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Interpretação de Imagem Assistida por Computador/normas , Hepatopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética/normas , Tomografia Computadorizada por Raios X/normas , Meios de Contraste , Progressão da Doença , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Projetos de Pesquisa , Estudos Retrospectivos
11.
J Am Chem Soc ; 136(29): 10299-307, 2014 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-24802029

RESUMO

Surface enhanced Raman scattering (SERS) spectra of organic monolayers were measured on various types of polycrystalline and single crystalline Pt substrates with nanometric or atomic surface features, including heteroepitaxial Pt monolayers, using sphere-plane type nanogap structures. Although atomic geometry and electronic structures of a metal surface significantly influence metal-molecule interactions, such effects are often hindered in conventional SERS measured on a roughened surface because of the spectral information averaging at various adsorption sites. In this study, the use of atomically defined Pt surfaces revealed detailed surface effects; the observed preferential adsorption geometry on each surface was well explained by atomic surface arrangements. The peak shift of the intramolecular vibration in the anchor group was in good agreement with the variation of the d-band center of Pt substrates. Moreover, in electrochemical SERS study the Stark shift of an extramolecular vibrational mode at around 400 cm(-1), which is not accessible in infrared absorption spectroscopy, was monitored on an atomically defined heteroepitaxial Pt monolayer electrode.

12.
Ann Vasc Surg ; 28(8): 1932.e1-4, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25017778

RESUMO

Intraarticular venous malformation (IAVM) of the knee is a rare vascular disease that manifests with pain, swelling, and hemarthrosis. A young man with left knee pain and swelling was admitted to our institution for the treatment of the IAVM of the left knee which was diagnosed by a local orthopedic doctor via arthroscopy. A total dose of 40 Gy of radiotherapy was delivered with a daily dose of 2.0 Gy using 6 MV X-ray beams and a linear accelerator through anteroposterior portals. Fifteen months after radiotherapy, follow-up examination using radiologic imaging showed distinct shrinkage of the venous malformations. Swelling and pain of the left knee had decreased, and range of motion of the left knee was maintained. This report describes a case involving a 38-year-old man with IAVM of the left knee in whom favorable outcomes were obtained in response to radiotherapy.


Assuntos
Joelho/irrigação sanguínea , Malformações Vasculares/radioterapia , Adulto , Fenômenos Biomecânicos , Fracionamento da Dose de Radiação , Humanos , Joelho/fisiopatologia , Imageamento por Ressonância Magnética , Masculino , Dor/etiologia , Amplitude de Movimento Articular , Fatores de Tempo , Resultado do Tratamento , Malformações Vasculares/complicações , Malformações Vasculares/diagnóstico , Malformações Vasculares/fisiopatologia , Veias/anormalidades
13.
Jpn J Radiol ; 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38581478

RESUMO

PURPOSE: The diagnosis of progressive fibrosing interstitial lung disease (PF-ILD) using computed tomography (CT) is an important medical practice in respiratory care, and most imaging findings for this disease have been obtained with inspiratory CT. It is possible that some characteristic changes in respiration may be seen in normal and diseased lung in PF-ILD, which may lead to a new understanding of the pathogenesis of interstitial pneumonia, but it has never been examined. In this study, we collected and selected inspiratory and expiratory CT scans performed in pure PF-ILD cases, and evaluated the volumes of diseased and normal lung separately by manual detection and 3-dimensional volumetry to characterize the dynamic features of PF-ILD. MATERIALS AND METHODS: Cases were collected retrospectively from a total of 753 inspiratory and expiratory CT scans performed at our hospital over a 3-year period. Sixteen cases of pure PF-ILD, excluding almost all other diseases, were included. We measured their diseased, normal, and the whole lung volumes manually and evaluated the correlation of their values and their relationship with respiratory function tests (FVC, FVC%-predicted, and DLCO%-predicted). RESULTS: The relative expansion rate of the diseased lung is no less than that of the normal lung. The "Expansion volume of total lung" divided by the "Expansion volume of normal lung" was found to be significantly associated with DLCO%-predicted abnormalities (p = 0.0073). CONCLUSION: The diseased lung in PF-ILD retained expansion capacity comparable to the normal lung, suggesting a negative impact on respiratory function.

14.
Obstet Gynecol ; 143(3): 358-365, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38061038

RESUMO

OBJECTIVE: To establish prediction models for the diagnosis of the subtypes of uterine leiomyomas by machine learning using magnetic resonance imaging (MRI) data. METHODS: This is a prospective observational study. Ninety uterine leiomyoma samples were obtained from 51 patients who underwent surgery for uterine leiomyomas. Seventy-one samples (49 mediator complex subunit 12 [ MED12 ] mutation-positive and 22 MED12 mutation-negative leiomyomas) were assigned to the primary data set to establish prediction models. Nineteen samples (13 MED12 mutation-positive and 6 MED12 mutation-negative leiomyomas) were assigned to the unknown testing data set to validate the prediction model utility. The tumor signal intensity was quantified by seven MRI sequences (T2-weighted imaging, apparent diffusion coefficient, magnetic resonance elastography, T1 mapping, magnetization transfer contrast, T2* blood oxygenation level dependent, and arterial spin labeling) that can estimate the collagen and water contents of uterine leiomyomas. After surgery, the MED12 mutations were genotyped. These results were used to establish prediction models based on machine learning by applying support vector classification and logistic regression for the diagnosis of uterine leiomyoma subtypes. The performance of the prediction models was evaluated by cross-validation within the primary data set and then finally evaluated by external validation using the unknown testing data set. RESULTS: The signal intensities of five MRI sequences (T2-weighted imaging, apparent diffusion coefficient, T1 mapping, magnetization transfer contrast, and T2* blood oxygenation level dependent) differed significantly between the subtypes. In cross-validation within the primary data set, both machine learning models (support vector classification and logistic regression) based on the five MRI sequences were highly predictive of the subtypes (area under the curve [AUC] 0.974 and 0.988, respectively). External validation with the unknown testing data set confirmed that both models were able to predict the subtypes for all samples (AUC 1.000, 100.0% accuracy). Our prediction models with T2-weighted imaging alone also showed high accuracy to discriminate the uterine leiomyoma subtypes. CONCLUSION: We established noninvasive prediction models for the diagnosis of the subtypes of uterine leiomyomas by machine learning using MRI data.


Assuntos
Leiomioma , Neoplasias Uterinas , Feminino , Humanos , Neoplasias Uterinas/diagnóstico por imagem , Neoplasias Uterinas/genética , Leiomioma/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Mutação
15.
Radiol Phys Technol ; 17(1): 195-206, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38165579

RESUMO

Somatostatin receptor scintigraphy (SRS) is an essential examination for the diagnosis of neuroendocrine tumors (NETs). This study developed a method to individually optimize the display of whole-body SRS images using a deep convolutional neural network (DCNN) reconstructed by transfer learning of a DCNN constructed using Gallium-67 (67Ga) images. The initial DCNN was constructed using U-Net to optimize the display of 67Ga images (493 cases/986 images), and a DCNN with transposed weight coefficients was reconstructed for the optimization of whole-body SRS images (133 cases/266 images). A DCNN was constructed for each observer using reference display conditions estimated in advance. Furthermore, to eliminate information loss in the original image, a grayscale linear process is performed based on the DCNN output image to obtain the final linearly corrected DCNN (LcDCNN) image. To verify the usefulness of the proposed method, an observer study using a paired-comparison method was conducted on the original, reference, and LcDCNN images of 15 cases with 30 images. The paired comparison method showed that in most cases (29/30), the LcDCNN images were significantly superior to the original images in terms of display conditions. When comparing the LcDCNN and reference images, the number of LcDCNN and reference images that were superior to each other in the display condition was 17 and 13, respectively, and in both cases, 6 of these images showed statistically significant differences. The optimized SRS images obtained using the proposed method, while reflecting the observer's preference, were superior to the conventional manually adjusted images.


Assuntos
Redes Neurais de Computação , Receptores de Somatostatina , Diagnóstico por Computador/métodos , Tomografia Computadorizada por Raios X , Cintilografia
16.
Magn Reson Med Sci ; 23(2): 146-152, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-36740257

RESUMO

PURPOSE: To evaluate the feasibility of breath-hold (BH) high-resolution (HR) T1-weighted gradient echo hepatobiliary phase (HBP) imaging using compressed sensing (CS) in gadoxetic acid-enhanced liver MRI in comparison with standard HBP imaging using parallel imaging (PI). METHODS: The study included 122 patients with liver tumors with hypointensity in the HBP who underwent both HR HBP imaging with CS and standard HBP imaging with PI. Two radiologists evaluated the liver edge sharpness, hepatic vessel conspicuity, bile duct conspicuity, image noise, and overall image quality, as well as the lesion conspicuity on HR and standard HBP imaging and the contrast-enhanced (CE) MR cholangiography (MRC) image quality reconstructed from HBP images. As a quantitative analysis, the SNR of the liver and the liver to lesion signal intensity ratio (LLSIR) were also determined. RESULTS: The liver edge sharpness, hepatic vessel conspicuity, bile duct conspicuity, and overall image quality as well as the lesion conspicuity and the LLSIR on HR HBP imaging with CS were significantly higher than those on standard HBP imaging (all of P < 0.001). The image quality of CE-MRC reconstructed from HR HBP imaging with CS was also significantly higher than that from standard HBP imaging (P < 0.001). Conversely, the SNR of liver in standard HBP was significantly higher than that in HR HBP with CS (P < 0.001). CONCLUSION: BH HR HBP imaging with CS provided an improved overall image quality, lesion conspicuity, and CE-MRC visualization when compared with standard HBP imaging without extending the acquisition time.


Assuntos
Meios de Contraste , Imageamento Tridimensional , Humanos , Imageamento Tridimensional/métodos , Fígado/diagnóstico por imagem , Fígado/patologia , Gadolínio DTPA , Imageamento por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Estudos Retrospectivos
17.
Eur J Radiol ; 170: 111245, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38042018

RESUMO

PURPOSE: To clarify the changes in the total renal volume over time with changes of the renal function using automated 3D volumetric CT of the whole kidney and to evaluate the usefulness of the total renal volume CT measurement in predicting chronic kidney disease (CKD) grade progression. METHODS: A total of 961 patients who underwent abdominal CT at least twice (an interval of more than 4 years) were included. The automated 3D volumetric CT measurement of the whole kidney was performed at the initial and latest CT examination. Patients with CKD grade G2 at the time of the initial CT were divided into two groups: a progression group (CKD grade progressed to G3-G5) and a non-progression group. Changes in the renal volume over time were compared between the two groups. RESULTS: The volume of both kidneys measured on initial CT was positively correlated with eGFR (ρ = 0.490, p < 0.001). There was a significant difference in the initial volume of both kidneys among CKD grades (p < 0.001, G1:318.7 ± 60.5 ml, G2:275.5 ± 53.5 ml, G3:233.7 ± 46.9 ml, G4:183.2 ± 22.5 ml, G5:157.7 ± 77.4 ml). When comparing the progression and non-progression groups, the initial volume of both kidneys was significantly smaller in the progression group, compared with the non-progression group (252.0 ± 50.6 ml vs. 278.9 ± 53.7 ml). In addition, the annual reduction volume in both the right and left kidneys was significantly greater in the progression group than in the non-progression group (p < 0.001). CONCLUSION: The automated 3D volumetric CT measurement of the whole kidney has the potential to monitor changes in renal volume over time with changes of the renal function.


Assuntos
Rim , Insuficiência Renal Crônica , Humanos , Rim/diagnóstico por imagem , Insuficiência Renal Crônica/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Progressão da Doença
18.
Abdom Radiol (NY) ; 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38940910

RESUMO

PURPOSE: To evaluate the image quality of ultra-high-resolution CT (U-HRCT) images reconstructed using an improved deep-learning-reconstruction (DLR) method. Additionally, we assessed the utility of U-HRCT in visualizing gastric wall structure, detecting gastric cancer, and determining the depth of invasion. METHODS: Forty-six patients with resected gastric cancer who underwent preoperative contrast-enhanced U-HRCT were included. The image quality of U-HRCT reconstructed using three different methods (standard DLR [AiCE], improved DLR-AiCE-Body Sharp [improved AiCE-BS], and hybrid-IR [AIDR3D]) was compared. Visualization of the gastric wall's three-layered structure in four regions and the visibility of gastric cancers were compared between U-HRCT and conventional HRCT (C-HRCT). The diagnostic ability of U-HRCT with the improved AiCE-BS for determining the depth of invasion of gastric cancers was assessed using postoperative pathology specimens. RESULTS: The mean noise level of U-HRCT with the improved AiCE-BS was significantly lower than that of the other two methods (p < 0.001). The overall image quality scores of the improved AiCE-BS images were significantly higher (p < 0.001). U-HRCT demonstrated significantly better conspicuity scores for the three-layered structure of the gastric wall than C-HRCT in all regions (p < 0.001). In addition, U-HRCT was found to have superior visibility of gastric cancer in comparison to C-HRCT (p < 0.001). The correct diagnostic rates for determining the depth of invasion of gastric cancer using C-HRCT and U-HRCT were 80%. CONCLUSIONS: U-HRCT reconstructed with the improved AiCE-BS provides clearer visualization of the three-layered gastric wall structure than other reconstruction methods. It is also valuable for detecting gastric cancer and assessing the depth of invasion.

19.
Hepatogastroenterology ; 60(124): 938-42, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23742854

RESUMO

BACKGROUND/AIMS: To develop a novel percutaneous radiologic gastrostomy using a large-bore, rupture-free, balloon (RFB) catheter in patients with a swallowing disturbance due to a neurological disorder. METHODOLOGY: Consecutive patients underwent percutaneous gastrostomy placement using a balloon catheter with a 5.0-cm 5.0-cm, large-bore, rupture-free balloon on the tip between August 2010 and December 2011. The large balloon in the stomach was percutaneously punctured by the needle, the guide wire was inserted through the abdominal wall, and the push-type gastrostomy tube was finally inserted over the guide wire via the oral cavity. Technical success and complications were evaluated. RESULTS: Fifteen patients (10 men, 5 women; age range, 47-82 years; mean age, 71.7 years) who had cerebral infarction (n=8), intracerebral hemorrhage (n=4), and subarachnoid hemorrhage (n=3) underwent percutaneous radiologic gastrostomy. The procedures were technically successful in all patients. The mean procedure time was 34+- 9 (SD) min (range, 20-47 min). The average follow-up was 158 days (range, 14 - 655 days). No major complications related to the procedure were encountered. CONCLUSION: Image-guided gastrostomy using a large-bore RFB catheter is an effective method of gastric feeding in patients with swallowing disturbance due to a neurological disorder.


Assuntos
Gastrostomia/instrumentação , Intubação Gastrointestinal/instrumentação , Radiografia Intervencionista , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Transtornos Cerebrovasculares/complicações , Meios de Contraste/administração & dosagem , Desenho de Equipamento , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
20.
Dysphagia ; 28(2): 253-9, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23370813

RESUMO

The aim of this study was to evaluate the clinical effectiveness of covered Niti-S stent placement under multidetector CT and fluoroscopy guidance for the palliation of dysphagia in patients with cervical esophageal cancer. Under radiological imaging guidance using axial and sagittal CT scans, and fluoroscopy, Niti-S esophageal stents were placed in ten consecutive patients with complete obstruction caused by cervical esophageal cancer (9 men and 1 woman; age range = 54-79 years; mean age = 68.1 years) between February 2010 and December 2011. The procedure time and technical success rate were evaluated. Swallowing improvement was assessed by the following items: ability to eat and/or swallow (graded as follows: 3 = ability to eat normal diet, 2 = ability to eat semisolids, 1 = ability to swallow liquids, 0 = complete obstruction). Procedural and post-procedural complications were also evaluated. Survival (mean ± SD) was examined. The mean (±SD) procedure time was 40 ± 19 min (range = 21-69 min). Stent placement was technically successful in all patients; inadequate stent deployment did not occur in any case. Ability to eat and/or swallow was improved and scored 2.4 (score 3 in 5 cases, score 2 in 4 cases, score 1 in 1 case, and score 0 in no case) after stent placement. No major or post-procedural complications were encountered. The mean survival time was 131 ± 77 days (range = 31-259 days). Niti-S stents appeared to be a safe and effective device for the palliation of dysphagia caused by advanced cervical esophageal cancer. Multidetector CT and fluoroscopy image guidance helped the operators accurately place the stents in the cervical esophagus.


Assuntos
Ligas , Materiais Revestidos Biocompatíveis , Transtornos de Deglutição/diagnóstico por imagem , Deglutição , Neoplasias Esofágicas/diagnóstico por imagem , Fluoroscopia/métodos , Stents , Idoso , Transtornos de Deglutição/etiologia , Transtornos de Deglutição/cirurgia , Neoplasias Esofágicas/complicações , Neoplasias Esofágicas/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Cuidados Paliativos/métodos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA