Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Catheter Cardiovasc Interv ; 103(6): 934-942, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38584522

RESUMO

BACKGROUND: Transcatheter closure of the patent ductus arteriosus (PDA) in premature infants is currently dependent on fluoroscopic guidance and transportation to the catheterization laboratory. AIM: We describe a new echocardiographically guided technique to allow our team to move to the bedside at the neonatal intensive care unit (NICU) of the referring center for percutaneous treatment of PDA in premature infants. METHODS: This is a single-center, retrospective, primarily descriptive analysis. Clinical details about the procedure, its outcomes, and complications were collected. RESULTS: Fifty-eight neonates with a median weight of 1110 g (range 730-2800) and postnatal age of 28 days (range 9-95) underwent percutaneous PDA closure. Five of them were treated in our center with ultrasound guidance only and the other 53 in 18 different neonatology units in 12 towns. The median duration of the procedure was 40 min (range 20-195 min). There were no procedural deaths. There was one residual shunt for 3 weeks, in all other patients the duct closed completely in the first few hours after the intervention. In one patient the procedure had to be interrupted because of a pericardial effusion which had to be drained, the PDA was closed successfully interventionally 5 days later. One device-related aortic coarctation had to be stented. One embolization and one late migration occurred and required treatment. CONCLUSIONS: Echocardiographically guided transcatheter closure of the PDA in prematures was repeatedly possible and allowed that the procedure is performed at the bedside at the NICU with an acceptable rate of complications.


Assuntos
Cateterismo Cardíaco , Permeabilidade do Canal Arterial , Ultrassonografia de Intervenção , Humanos , Permeabilidade do Canal Arterial/terapia , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Recém-Nascido , Estudos Retrospectivos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Resultado do Tratamento , Idade Gestacional , Valor Preditivo dos Testes , Masculino , Feminino , Fatores de Tempo , Índice de Gravidade de Doença , Recém-Nascido Prematuro , Lactente Extremamente Prematuro , Unidades de Terapia Intensiva Neonatal , Sistemas Automatizados de Assistência Junto ao Leito , Testes Imediatos , Dispositivo para Oclusão Septal , Lactente
2.
Catheter Cardiovasc Interv ; 99(7): 2054-2063, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35395135

RESUMO

BACKGROUND: Covered stents perform similar to surgically implanted conduits, although the stents work inside of vessels. We present a computed tomography (CT)-based workflow for the implantation of covered stents as extravascular conduits. METHODS: We selected three different use cases: 1. Connecting a left-sided partially anomalous drainage of a pulmonary vein to the left atrium. 2. Bypassing an outgrown Dacron conduit in aortic recoarctation. 3. Re-directing hepatic venous blood to the left lung in a Fontan patient with heterotaxy, connecting the innominate vein to the right pulmonary artery like a right-sided cavopulmonary connection. By postprocessing and analyzing CT scans for planning and by the use of long needles under biplane fluoroscopy for the realization of the procedure, we projected and performed the exit of a long needle out of a vessel, the re-entering of a target vessel, and the bridging of the extravascular distance by implantation of covered stents. RESULTS: In all three cases, the covered stents were placed successfully, connecting vessels of 15-50 mm distance from each other with very good hemodynamic results. In one case, two stents were placed consecutively, overlapping each other to accomplish an exact fitting at the connection sites to the native vessels.


Assuntos
Cardiopatias Congênitas , Veias Pulmonares , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Humanos , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Stents , Tomografia Computadorizada por Raios X , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 95(7): 1305-1309, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32043804

RESUMO

We report on two patients who received a transcatheter cavopulmonary connection by a needle puncture under deep conscious sedation. In both patients, the vessel-to-vessel connection was achieved by a venous access into the superior caval vein and direct needle puncture of the pulmonary artery. The two cavopulmonary anastomoses were held open by a covered stent and a bare-metal stent, respectively.


Assuntos
Cateterismo Cardíaco , Técnica de Fontan/métodos , Cardiopatias Congênitas/terapia , Artéria Pulmonar , Veia Cava Superior , Adolescente , Cateterismo Cardíaco/instrumentação , Sedação Consciente , Técnica de Fontan/instrumentação , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Hemodinâmica , Humanos , Pessoa de Meia-Idade , Agulhas , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Punções , Recuperação de Função Fisiológica , Stents , Resultado do Tratamento , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/fisiopatologia
4.
Cardiol Young ; 30(10): 1458-1461, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32778192

RESUMO

BACKGROUND: Catheterization in small children should be performed with the lowest diameter introducer sheaths to prevent permanent vessel damage. The objective of this study is to evaluate the clinical safety and efficacy of the Glidesheath Slender in small children. METHODS AND RESULTS: We present a group of 52 patients (male: n = 36) with median age 118.5 days (min. 3; max. 1302), median weight: 5.3 kg (min. 1.4; max. 14.0), median height: 60.5 cm (min. 39; max. 102), and median body surface area 0.28 m2 (min. 0.12; max. 0.63) in whom percutaneous catheter interventions (n = 55) were performed via a Glidesheath Slender. In 49 children, the intervention was performed from femoral access (artery n = 35; vein n = 14) in 2 from the axillary arterial access and in 1 from the jugular venous access. In all patients, the vessel access was obtained under ultrasound guidance. After the catheterization, the pulse on the peripheral arteries (posterior tibial artery or radial artery) was palpable in all patients, and no signs for vessel dysfunction were present. CONCLUSION: The Glidesheath Slender effectively reduces the outer sheath diameter for various types of interventions in small children by one French, reducing the risk of vessel complications (stenosis, occlusion). Interventions via Glidesheath Slender in small patients are safe and feasible and extend the transcatheter possibilities in small children with congenital heart diseases.


Assuntos
Intervenção Coronária Percutânea , Idoso de 80 Anos ou mais , Cateteres Cardíacos , Cateterismo , Criança , Artéria Femoral , Humanos , Masculino , Artéria Radial/cirurgia , Resultado do Tratamento
5.
Thorac Cardiovasc Surg ; 67(1): 37-43, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29715702

RESUMO

BACKGROUND: The aim of this study was to evaluate the incidence and risk factors for the development of right ventricular outflow tract obstruction (RVOTO) after the arterial switch operation (ASO). METHODS: Between 1983 and 2014, a total of 688 patients underwent ASO. RVOTO was defined as any obstruction of the right ventricular outflow tract (RVOT) requiring reintervention. RESULTS: RVOTO developed in 79 patients (11%) at a median time of 3.8 years (range, 1 day-23.6 years) after ASO. Freedom from RVOT reintervention was 96 ± 1, 89 ± 1, and 83 ± 2% at 1, 10, and 25 years, respectively. Independent risk factors for the development of RVOTO in a Cox's regression model were side-by-side great arteries (p < 0.001), aortic arch anomalies (p < 0.001), use of a pericardial patch for augmentation of the coronary buttons (p < 0.001), and a peak gradient more than 20 mm Hg over the RVOT at discharge (p < 0.001). CONCLUSION: The incidence of RVOTO after ASO is not negligible. Complex morphology, such as side-by-side great arteries and aortic arch anomalies influences the development of RVOTO.


Assuntos
Transposição das Grandes Artérias/efeitos adversos , Transposição dos Grandes Vasos/cirurgia , Obstrução do Fluxo Ventricular Externo/epidemiologia , Criança , Pré-Escolar , Feminino , Alemanha/epidemiologia , Humanos , Incidência , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Transposição dos Grandes Vasos/diagnóstico , Transposição dos Grandes Vasos/epidemiologia , Transposição dos Grandes Vasos/fisiopatologia , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/diagnóstico , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Obstrução do Fluxo Ventricular Externo/terapia
6.
Cardiol Young ; 28(2): 347-350, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29081324

RESUMO

In this article, we report on a newborn with hypoplastic left heart syndrome in whom recoarctation of the aorta was treated with a bare metal stent (Cook Formula 414 Stent) in the early postoperative period after a Norwood procedure. To reduce the risk for scarring and occluding the femoral artery the stent was implanted via 5F Glidesheath Slender sheath.


Assuntos
Coartação Aórtica/etiologia , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Procedimentos de Norwood/efeitos adversos , Complicações Pós-Operatórias , Procedimentos Cirúrgicos Vasculares/métodos , Coartação Aórtica/diagnóstico , Coartação Aórtica/cirurgia , Humanos , Recém-Nascido , Masculino , Reoperação , Fatores de Tempo , Resultado do Tratamento
7.
Cardiol Young ; 28(7): 955-960, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29779498

RESUMO

OBJECTIVES: This study aimed to develop a method for retrieval of the new meshed nitinol atrial septal defect occluders - Ceraflex and Occlutech. BACKGROUND: The newly developed atrial septal defect occluders have potential benefits considering implantation, but concerns regarding their removal in case of embolisation have been raised. METHODS: Over 21 years, 1449 patients underwent interventional atrial septal defect occlusion in our institution. We reviewed the cases of embolisation of the device, developed a strategy for device removal, and tested it on the benchside and in animal tests. RESULTS: In 11 patients (0.8%), the intended atrial septal defect occlusion was complicated by an embolisation of the device. In contrast to the Amplatzer septal occluders, retrieval of Occlutech devices larger than 16 mm with snare techniques was impossible. In benchside tests, this was confirmed and a new method for removal of large meshed devices was developed. This involved the commercially available Maslanka® biopsy forceps. The feasibility of this technique in vivo was tested in a pig model. During animal tests, using the Maslanka biopsy forceps it was possible to interventionally retrieve embolised Ceraflex and Occlutech devices of different sizes - 10, 16, 30, and 40 mm - into a 12-F sheath. CONCLUSION: It was impossible to retrieve Occlutech and Ceraflex devices larger than 16 mm into a large sheath in vivo and during benchside tests. However, this was feasible on the bench and in vivo using the Maslanka biopsy forceps even with the largest available devices.


Assuntos
Cateterismo Cardíaco/instrumentação , Remoção de Dispositivo/métodos , Embolia/terapia , Comunicação Interatrial/terapia , Falha de Prótese , Dispositivo para Oclusão Septal , Adolescente , Adulto , Idoso , Angiografia , Animais , Cateterismo Cardíaco/efeitos adversos , Criança , Embolia/etiologia , Feminino , Comunicação Interatrial/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Animais , Estudo de Prova de Conceito , Desenho de Prótese , Suínos , Resultado do Tratamento , Adulto Jovem
9.
Pediatr Cardiol ; 38(2): 353-361, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27885445

RESUMO

The atrial baffle repair (ABR) significantly improved the fate of patients with transposition of the great arteries (TGA). However, these patients show impaired exercise tolerance and some present severe decline of systemic ventricular function. Intrinsic myocardial weakness, low heart rate response to exercise and diastolic filling impairment are discussed to be causative. Forty-nine long-term survivors with TGA (median age 23.7 year) after ABR were catheterized with measured oxygen consumption in four conditions (baseline, volume, atrial pacing, dobutamine) and the results were compared to 10 normal controls. Median cardiac output was significantly lower in the ABR group (2.2 vs. 2.6 l/min/m2; p = 0.015), and systemic resistance was significantly elevated (28.9 vs. 22.2 U m2; p = 0.04) in comparison with normals. While stroke volume rose by 27% in the control group, it dropped by 7% in patients after ABR at atrial pacing (80/min). Stroke volume increase after dobutamine was significantly lower after ABR in comparison with normal controls (34 vs. 106%; p = 0.001). Higher NYHA class (p = 0.043), degree of tricuspid regurgitation (p = 0.009) and ventricular function (p = 0.028) were associated with lower stroke volume increase. Limited exercise capability of patients after ABR for TGA is primarily due to limited diastolic filling of the ventricles due to stiff non-compliant atrial pathways. Elevated systemic resistance may lead to severe myocardial hypertrophy with possible ischemia and contribute to the multifactorial decline of ventricular function in some patients.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Átrios do Coração/cirurgia , Volume Sistólico , Transposição dos Grandes Vasos/cirurgia , Disfunção Ventricular Direita/fisiopatologia , Adolescente , Adulto , Estudos de Casos e Controles , Diástole , Dobutamina/administração & dosagem , Tolerância ao Exercício , Feminino , Humanos , Masculino , Consumo de Oxigênio , Adulto Jovem
10.
Cardiol Young ; 25(1): 151-3, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24345740

RESUMO

Plastic bronchitis is a severe complication after a Fontan procedure, with an estimated incidence around 1-2% and poor prognosis. We present the cases of four patients with plastic bronchitis after a total cavopulmonary connection with a stenosis of the left pulmonary artery that was stented successfully. In three of the four patients, symptoms improved after catheter intervention in combination with pulmonary vasodilator and inhalative treatment.


Assuntos
Bronquite/etiologia , Técnica de Fontan/efeitos adversos , Complicações Pós-Operatórias , Artéria Pulmonar/cirurgia , Stents , Bronquite/diagnóstico , Pré-Escolar , Seguimentos , Humanos , Lactente , Radiografia Torácica
11.
Cardiovasc Diagn Ther ; 13(3): 599-608, 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37405012

RESUMO

The development of veno-venous collaterals is an important and treatable cause of cyanosis in patients who had undergone partial cavo-pulmonary connection (PCPC) operations. Nevertheless, the literature on this complicated therapeutic option is sparse. Patients can present cyanosis either immediately after the operation (<30 days), which delays or hinders discharge from the intensive care unit or cyanosis may occur late: (>30 days and/or in another hospital admission), after the operation. Hence, transcatheter closure of veno-venous collaterals is the treatment of choice. Four patients were selected who showed cyanosis at variable durations after PCPC; the morphology of the collaterals and their hemodynamic effect was described and the strategy for closure of such abnormal vessels is suggested. Veno-venous collaterals described in our series were seen originating mainly or mostly from innominate vein angles. The drainage sites were either above the diaphragm into a cardiac structure: the coronary sinus (CS) and/or atria; or below the diaphragm into the inferior vena cava (IVC) or hepatic veins through the paravertebral venous system and/or the azygous system. It is stated in the literature that several types of devices and coils can be used to close the collaterals such as the Amplatzer vascular plugs (AVPs), Amplatzer duct occluder II (ADOII), non-detachable and detachable coils. In this clinical review, the technical details that determine device type and size are explained. The recent generations of hydrogel-coated coils were also used in this series of patients to close the difficult types of collaterals with better results. All described vessels were closed successfully, without any complications. The patients had a significant rise in their transcutaneous oxygen saturations and hence, a clear clinical benefit.

12.
Cardiovasc Diagn Ther ; 12(4): 475-484, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36033225

RESUMO

Background: The last decades have brought remarkable improvements in treatment strategy and occluder modification of secundum atrial septal defect (ASD) closure. Approval, efficacy and safety of ASD closure devices have previously been demonstrated. This study investigated the clinical efficacy and safety of the LifeTech CeraFlexTM ASD occluder for interventional closure of secundum ASD with a 6-month follow-up (FU). Methods: Procedure specific data was collected on patients considered for ASD closure with the CeraFlexTM occluder between April 2016 and December 2019 in three German centers. Efficacy and safety were assessed after device closure, at discharge, and at 6-month FU. Results: The primary endpoint (successful ASD closure without severe complications) was reached by 102/103 patients (99%). Device embolization occurred in two patients (one early and one late embolization). After early snare-retrieval of an embolized device, this ASD was closed surgically and in the other patient with late device embolization the defect was closed with a larger CeraFlexTM occluder. The secondary endpoint (clincal efficacy after 6 months) was reached by 94/98 patients since new onset of arrhythmia occurred in four patients. Three patients had withdrawn their study-participation and one patient had moderate residual shunt, but not related to the occluder. Incomplete right bundle branch block (iRBBB) was seen in 31 patients. At last FU only 17 patients had remaining iRBBB documenting effective volume unloading of the right ventricle. Conclusions: Catheter interventional closure of secundum ASDs with the CeraFlexTM ASD occluder was feasible, safe and effective in this study.

13.
Cardiovasc Diagn Ther ; 11(2): 631-636, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33968640

RESUMO

Cyanosis persisting after surgical repair of complex congenital heart disease (CHD) may be related to the underlying disease. However, extracardiac causes should be also considered. We report on a patient with heterotaxy syndrome and double outlet right ventricle, in whom postoperative cyanosis was associated with an Abernethy malformation type II causing a hepatopulmonary syndrome. Despite this complex anatomy, interventional closure of the portosystemic shunt was done with a Konar MF™-VSD Occluder. The patient recovered rapidly with relief of cyanosis within one month. This case highlights the importance of a careful diagnostic assessment in patients with complex CHD, who presents cyanoses after surgical repair. In addition, it shows the feasibility and safety of a percutaneous approach with complete closure of the vascular malformation in a patient with a complex anatomy.

14.
J Am Heart Assoc ; 10(20): e021416, 2021 10 19.
Artigo em Inglês | MEDLINE | ID: mdl-34612047

RESUMO

Background Right atrial (RA) dilatation and impaired right ventricular (RV) filling are common in patients with RV outflow tract dysfunction. We aimed to study potential correlations between atrial function with clinically relevant hemodynamic parameters and to assess the predictive impact of atrial performance on the recovery of exercise capacity and RV pump function after percutaneous pulmonary valve implantation (PPVI). Methods and Results Altogether, 105 patients with right ventricular outflow tract dysfunction (median age at PPVI, 19.2 years; range, 6.2-53.4 years) who underwent cardiac magnetic resonance imaging before and 6 months after PPVI were included. RA and left atrial maximal and minimal volumes as well as atrial passive and active emptying function were assessed from axial cine slices. RA emptying function was inversely related to invasive RV end-diastolic pressure, and RA passive emptying correlated significantly with peak oxygen uptake. After PPVI, a significant decrease in RA minimum volume was observed, whereas RA passive emptying function improved, and RA active emptying function decreased significantly. Patients with predominant right ventricular outflow tract stenosis showed more favorable changes in RA active and left atrial passive emptying than those with primary volume overload. None of the RA and left atrial emptying parameters was predictive for recovery of peak oxygen uptake or RV ejection fraction. Conclusions In patients with right ventricular outflow tract dysfunction, impaired RA emptying assessed by cardiac magnetic resonance imaging was associated with increased RV filling pressures and lower exercise capacity. PPVI leads to a reduction in RA size and improved passive RA emptying function. However, RA function was not associated with improved exercise performance and RV pump function.


Assuntos
Remodelamento Atrial , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Pulmonar , Valva Pulmonar , Função do Átrio Direito , Tolerância ao Exercício , Humanos , Oxigênio , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/cirurgia , Função Ventricular Direita
15.
Int J Cardiol ; 331: 82-87, 2021 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-33548378

RESUMO

BACKGROUND: In our study, we sought to analyse the mid-term results after interventional aortic coarctation (CoA) stenting with sequential dilation of the stent. METHODS: The data of all 218 patients, who are above the age of 6 years and underwent CoA-stent implantation in our hospital, were retrospectively analysed on the rate of re-interventions, complications and arterial hypertension at a follow-up time of 31 months. To avoid any aortic complications, stents were deployed primarily not in full size and a second cardiac catheterisation for further dilatation was scheduled within 6-12 months after the stent implantation. RESULTS: The median peak invasive systolic pressure gradient declined significantly from 26.2 mmHg to 2.7 mmHg after stenting. There was one procedure related death due to an aortic rupture after stent implantation. There were in total 33 (15.1%) procedure-related complications including femoral artery complications, stent fracture and stent dislocation (in 9, 9 and 7 patients, respectively). In 85 patients a re-dilatation and in 25 patients a second stent-implantation was necessary at the first re-intervention. The systolic blood pressure declined significantly from 144 mmHg to 131 mmHg after stenting. The number of patients being normotensive changed from 18% before stenting to 78.5% after stenting with adjusted antihypertensive medication. CONCLUSION: Aortic stenting is an effective means for CoA treatment. With sequential dilation of the stent, a very low rate of life-threatening procedural complications and mortality can be achieved. CoA stenting with proper antihypertensive medications results in better control of blood pressure.


Assuntos
Coartação Aórtica , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/cirurgia , Criança , Dilatação , Humanos , Estudos Retrospectivos , Stents/efeitos adversos , Resultado do Tratamento
17.
Circ Cardiovasc Interv ; 13(7): e008963, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32600110

RESUMO

BACKGROUND: Percutaneous pulmonary valve implantation (PPVI) has become an important treatment of right ventricular outflow tract dysfunction. Studies directly comparing the long-term outcome of PPVI with the Melody valve to surgical pulmonary valve replacement (SPVR) are lacking. METHODS: All patients treated with PPVI with the Melody valve and SPVR between January 2006 and December 2018 in our center were enrolled into a database and investigated with a standard follow-up protocol. The current study compares the outcomes in means of survival, reinterventions, infectious endocarditis, and performance of the valves. RESULTS: The study included 452 patients, of whom 241 were treated with PPVI with the Melody valve and 211 patients with SPVR with different types of valves. Median follow-up time was 5.4 years (3 months to 12.5 years), and the total observation was 2449 patient-years. Estimated survival after 10 years was 94% in the Melody group and 92% in the SPVR group (P=0.47). There was no difference in the estimated survival free of surgery on the implanted valve at 10 years (Melody, 87%, versus SPVR, 87%; P=0.54) or in the survival with the originally implanted pulmonary valve (Melody group, 80%; SPVR group, 73%; P=0.46) between both groups. The annualized incidence of infective endocarditis was 1.6% in the Melody group and 0.5% in the SPVR group, and the estimated survival free of endocarditis did not differ significantly between groups (Melody group, 82%; SPVR group, 86%; P=0.082). Survival free of valve replacement because of infective endocarditis was comparable between both groups (Melody, 88%; SPVR, 88%; P=0.35). CONCLUSIONS: PPVI with the Melody valve and SPVR provides similar survival, freedom of reinterventions, and infective endocarditis with or without the need of replacement of the pulmonary valve. Being less invasive, PPVI should be considered a method for treatment for patients with dysfunctional right ventricular outflow tracts.


Assuntos
Bioprótese , Cateterismo Cardíaco/instrumentação , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Valva Pulmonar/cirurgia , Adolescente , Adulto , Idoso , Bioprótese/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Criança , Pré-Escolar , Bases de Dados Factuais , Remoção de Dispositivo , Endocardite/mortalidade , Endocardite/cirurgia , Feminino , Seguimentos , Alemanha , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/mortalidade , Doenças das Valvas Cardíacas/fisiopatologia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Intervalo Livre de Progressão , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Infecções Relacionadas à Prótese/mortalidade , Infecções Relacionadas à Prótese/cirurgia , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Recuperação de Função Fisiológica , Reoperação , Fatores de Tempo , Adulto Jovem
18.
Cardiovasc Diagn Ther ; 9(Suppl 2): S264-S268, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31737534

RESUMO

BACKGROUND: Pre-stenting is a widely used technique for transcatheter pulmonary valve implantation (TPVI). For the Melody valve a pre-stent creates a reliable and solid landing zone. In contrast to the Melody valve, the Edwards Sapien valve consists of a strong balloon expandable stent designed for implantation in the aortic position. The usage of a Sapien valve in pulmonary position might therefore obviate the need of a pre-stent. METHODS: This retrospective, single centre study reviewed the procedural outcomes of patients receiving the Sapien XT transcatheter valve in pulmonary position without prior implantation of a pre-stent. All consecutive patients with dysfunctional right ventricle to pulmonary artery (RV-PA) conduits or with dysfunctional pulmonary valve treated at the German Heart Centre in Munich were included in this study. RESULTS: We report on successful implantation of a Sapien XT/3 without usage of a pre-stent. CONCLUSIONS: Abandonment of the pre-stent simplified the procedure and reduces the radiation burden for the patients.

19.
JACC Cardiovasc Interv ; 12(16): 1594-1603, 2019 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-31202951

RESUMO

OBJECTIVES: The aim of this study was to report long-term outcomes after percutaneous pulmonary valve implantation (PPVI). BACKGROUND: Excellent short- and mid-term results after PPVI for right ventricular outflow tract (RVOT) dysfunction have been reported. Data on long-term results after PPVI are scarce. METHODS: All 226 patients treated with PPVI at a single institution were prospectively enrolled in a database and included in the study. Follow-up information regarding outcomes was collected. Risk-factor analysis for death and reinterventions was performed. RESULTS: Follow-up data (up to 11 years) were available in 96% of the patients. At the end of the study period, 219 patients (92.8%) still lived with the initially implanted valve. Seven patients died, 2 of them from procedure-related complications. Seventeen patients (7.2%) needed valve replacement surgically (n = 11) or percutaneously (n = 6) for infectious endocarditis (n = 10) or valve degeneration (n = 7). In the remaining patients, the valves retained excellent function, and right ventricular dimensions and exercise capacity improved. A post-interventional RVOT gradient >15 mm Hg was a risk factor for death (hazard ratio: 7.57; 95% confidence interval: 1.26 to 45.38; p = 0.027) and for valve failure (hazard ratio: 3.76; 95% confidence interval: 1.43 to 9.93; p = 0.007). The best outcome was achieved with RVOT pre-stenting and a post-interventional gradient <15 mm Hg, resulting in an estimated event-free survival rate of 88% at 10 years. CONCLUSIONS: Patients after PPVI have excellent long-term outcomes. Right ventricular volumes, function, and exercise capacity improve significantly. A residual RVOT gradient <15 mm Hg was associated with the best outcome.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Estenose da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Disfunção Ventricular Direita/cirurgia , Função Ventricular Direita , Pressão Ventricular , Adolescente , Adulto , Idoso , Valvuloplastia com Balão , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Criança , Pré-Escolar , Bases de Dados Factuais , Remoção de Dispositivo , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Intervalo Livre de Progressão , Estudos Prospectivos , Falha de Prótese , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/mortalidade , Estenose da Valva Pulmonar/fisiopatologia , Fatores de Risco , Fatores de Tempo , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/mortalidade , Disfunção Ventricular Direita/fisiopatologia , Adulto Jovem
20.
Int J Cardiol ; 258: 31-35, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29544952

RESUMO

BACKGROUND: To investigate the feasibility and mid-term results of percutaneous pulmonary valve implantation (PPVI) in patients with conduit free or "native" right ventricular outflow tracts (RVOT). METHODS AND RESULTS: We identified all 18 patients with conduit free or "native" right ventricular outflow tract, who were treated with percutaneous pulmonary valve implantation (PPVI) in our institution. They were divided into two groups - these in whom the central pulmonary artery was used as an anchoring point for the preparation of the landing zone (n=10) for PPVI and these, in whom a pulmonary artery branch was used for this purpose (n=8). PPVI was performed successfully in all patients with significant immediate RVOT gradient and pulmonary regurgitation grade reduction. Four patients had insignificant paravalvular regurgitation. In one patient the valve was explanted after 4months because of bacterial endocarditis. A follow-up of 19 (4-60) months showed sustained good function of the other implanted valves. The MRI indexed right ventricular end diastolic volume significantly decreased from 108(54-174) ml/m2 before the procedure to 76(60-126) ml/m2 six months after PPVI, p=0.01. CONCLUSIONS: PPVI is feasible with good mid-term results in selected patients with a "native" RVOT without a previously implanted conduit. Creating a stable landing zone with a diameter less than the largest available valve (currently 29mm) is crucial for the technical success of the procedure. Further studies and the development of new devices could widen the indications for this novel treatment.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/cirurgia , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/cirurgia , Adolescente , Adulto , Criança , Feminino , Seguimentos , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/tendências , Masculino , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA