Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Pain Med ; 21(5): 902-909, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31609391

RESUMO

OBJECTIVES: Although the effectiveness of lumbar medial branch radiofrequency ablation (RFA) for the treatment of zygapophyseal joint (z-joint)-mediated low back pain has been characterized, few studies have described outcomes in patients selected using a guideline-concordant paradigm of ≥80% pain relief with dual comparative medial branch blocks (MBBs). We investigated long-term treatment outcomes of patients selected according to this paradigm. DESIGN: Cross-sectional cohort study. METHODS: The medical records of 111 consecutive patients were reviewed; 85 met inclusion criteria. A standardized telephone survey was used to capture current numerical rating scale (NRS) and Patient Global Impression of Change (PGIC) scores. The primary outcome was the proportion of patients reporting ≥50% reduction of index pain. Binary logistic regression analysis was performed to explore associations between the primary outcome and covariates, including age, duration of pain, presence of scoliosis, degenerative spondylolisthesis, and >75% disc height loss. RESULTS: At six to 12, 12-24, and >24 months, 63.2% (95% confidence interval [CI] = 41-85%), 65.6% (95% CI = 49-82%), and 44.1% (95% CI = 27-61%) of patients reported a ≥50% pain reduction (P = 0.170), respectively. At a minimum of six months, 70.6% of patients reported a pain reduction of two or more points (minimally clinically important change), and 54.1% reported a PGIC score consistent with "much improved" or better. Older age and a smaller Cobb angle were associated with a ≥50% pain reduction (P < 0.05). CONCLUSION: Lumbar medial branch RFA is an effective, durable treatment for a significant proportion of patients with recalcitrant lumbar z-joint pain when candidacy is determined by the guideline-concordant paradigm of ≥80% pain relief with dual comparative MBBs.


Assuntos
Dor Lombar , Bloqueio Nervoso , Ablação por Radiofrequência , Articulação Zigapofisária , Idoso , Artralgia , Estudos Transversais , Humanos , Dor Lombar/cirurgia , Resultado do Tratamento , Articulação Zigapofisária/cirurgia
4.
Magn Reson Med ; 69(5): 1486-93, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-22777692

RESUMO

The purpose of this work was to design and construct a multichannel receive-only radiofrequency coil for 3T magnetic resonance imaging of the human carotid artery and bifurcation with optimized signal-to-noise ratio (SNR) in the carotid vessels along the full extent of the neck. A neck phantom designed to match the anatomy of a subject with a neck representing the body habitus often seen in subjects with carotid arterial disease was constructed. Sixteen circular coil elements were arranged on a semirigid fiberglass former that closely fit the shape of the phantom, resulting in a 16-channel bilateral phased array coil. Comparisons were made between this coil and a typical 4-channel carotid coil in a study of 10 carotid vessels in five healthy volunteers. The 16-channel carotid coil showed a 73% average improvement in SNR at the carotid bifurcation. This coil also maintained an SNR greater than the peak SNR of the 4-channel coil over a vessel length of 10 cm. The resulting increase in SNR improved vessel depiction of the carotid arteries over an extended field of view, and demonstrated better image quality for higher parallel imaging reduction factors compared to the 4-channel coil.


Assuntos
Algoritmos , Artérias Carótidas/anatomia & histologia , Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
A A Pract ; 17(5): e01681, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37146225

RESUMO

Brachial plexus avulsion injuries result in permanent motor and sensory deficits, leading to debilitating symptoms. We report the case of a 25-year-old man with chronic pain following right-sided C5-T1 nerve root avulsion without evidence of peripheral nerve injury. His pain was recalcitrant to medical and neurosurgical interventions. However, he experienced substantial (>70%) pain relief with peripheral nerve stimulation targeting the median nerve. These results agree with data suggesting collateral sprouting of sensory nerves occurs following a brachial plexus injury. Further study is needed if we are to understand the mechanisms of the peripheral nerve stimulator as a treatment option.


Assuntos
Plexo Braquial , Dor Crônica , Neuralgia , Estimulação Elétrica Nervosa Transcutânea , Masculino , Humanos , Adulto , Plexo Braquial/cirurgia , Neuralgia/terapia , Neuralgia/etiologia , Dor Crônica/terapia , Procedimentos Neurocirúrgicos/efeitos adversos
6.
Can J Pain ; 7(1): 2249054, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37771636

RESUMO

Chronic pain following distal biceps rupture (DBR) is often nonspecific in that it may arise due to the injury, subsequent surgical repair, or a combination of factors, making the painful symptoms challenging to treat. Peripheral nerve injury in the setting of DBR most commonly affects the musculocutaneous nerve or one of its terminal branches and may lead to chronic neuropathic pain involving the elbow and lateral/radial aspect of the forearm. In this brief technical report, we describe an ultrasound-guided (USG) technique for percutaneous implantation of a peripheral nerve stimulator (PNS) targeting the musculocutaneous nerve, along with an illustrative case report of successful treatment of chronic refractory pain following DBR utilizing this technique. Six months postimplantation, the patient reported a greater than 60% baseline pain intensity reduction, and no complications were noted.


La douleur chronique consécutive à une rupture distale du biceps est souvent non spécifique en ce sens qu'elle peut survenir en raison de la blessure, de la réparation chirurgicale ultérieure, ou d'une combinaison de facteurs, rendant les symptômes douloureux difficiles à traiter. La lésion du nerf périphérique dans le cadre d'une rupture distale du biceps affecte le plus souvent le nerf musculo-cutané ou l'une de ses branches terminales et peut entraîner des douleurs neuropathiques chroniques au niveau du coude et de la face latérale/radiale de l'avant-bras. Dans ce bref rapport technique, nous décrivons une technique guidée par ultrason pour l'implantation percutanée d'un stimulateur nerveux périphérique ciblant le nerf musculo-cutané, ainsi qu'un rapport de cas illustratif du traitement réussi de la douleur réfractaire suite à une rupture distale du biceps en utilisant cette technique. Six mois après l'implantation, le patient a signalé une réduction de plus de 60 % de l'intensité de la douleur initiale, et aucune complication n'a été observée.

7.
Am J Phys Med Rehabil ; 101(5): 482-492, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-35006653

RESUMO

ABSTRACT: The objective was to determine the effectiveness of fluoroscopically guided genicular nerve radiofrequency ablation for painful knee osteoarthritis. Primary outcome measure was improvement in pain after 6 mos. Secondary outcomes included the Oxford Knee Score and Western Ontario and McMaster Universities Osteoarthritis Index. Two reviewers independently assessed publications before October 10, 2020. The Cochrane Risk of Bias Tool and Grades of Recommendation, Assessment, Development, and Evaluation system were used. One hundred ninety-nine publications were screened, and nine were included. Six-month success rates for 50% or greater pain relief after radiofrequency ablation ranged from 49% to 74%. When compared with intra-articular steroid injection, the probability of success was 4.5 times higher for radiofrequency ablation (relative risk = 4.58 [95% confidence interval = 2.61-8.04]). When radiofrequency ablation was compared with hyaluronic acid injection, the probability of treatment success was 1.8 times higher (relative risk = 1.88, 95% confidence interval = 1.38-2.57). The group mean Oxford Knee Score and Western Ontario and McMaster Universities Osteoarthritis Index scores improved in participants receiving genicular radiofrequency ablation compared with intra-articular steroid injection and hyaluronic acid injection. According to Grades of Recommendation, Assessment, Development, and Evaluation, there is moderate-quality evidence that fluoroscopically guided genicular radiofrequency ablation is effective for reducing pain associated with knee osteoarthritis at minimum of 6 mos. Further research is likely to have an important impact on the current understanding of the long-term effectiveness of this treatment.


Assuntos
Dor Crônica , Osteoartrite do Joelho , Ablação por Radiofrequência , Dor Crônica/complicações , Dor Crônica/terapia , Humanos , Ácido Hialurônico , Articulação do Joelho , Osteoartrite do Joelho/complicações , Osteoartrite do Joelho/cirurgia , Dor/complicações , Estudos Prospectivos , Esteroides , Resultado do Tratamento
8.
J Crit Care ; 28(6): 959-63, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23958243

RESUMO

INTRODUCTION: Heart rate variability (HRV) reflects autonomic nervous system tone as well as the overall health of the baroreflex system. We hypothesized that loss of complexity in HRV upon intensive care unit (ICU) admission would be associated with unsuccessful early resuscitation of sepsis. METHODS: We prospectively enrolled patients admitted to ICUs with severe sepsis or septic shock from 2009 to 2011. We studied 30 minutes of electrocardiogram, sampled at 500 Hz, at ICU admission and calculated heart rate complexity via detrended fluctuation analysis. Primary outcome was vasopressor independence at 24 hours after ICU admission. Secondary outcome was 28-day mortality. RESULTS: We studied 48 patients, of whom 60% were vasopressor independent at 24 hours. Five (10%) died within 28 days. The ratio of fractal alpha parameters was associated with both vasopressor independence and 28-day mortality (P = .04) after controlling for mean heart rate. In the optimal model, Sequential Organ Failure Assessment score and the long-term fractal α parameter were associated with vasopressor independence. CONCLUSIONS: Loss of complexity in HRV is associated with worse outcome early in severe sepsis and septic shock. Further work should evaluate whether complexity of HRV could guide treatment in sepsis.


Assuntos
Fractais , Frequência Cardíaca/fisiologia , Ressuscitação/métodos , Sepse/fisiopatologia , Sepse/terapia , APACHE , Adulto , Teorema de Bayes , Eletrocardiografia , Feminino , Mortalidade Hospitalar , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sepse/mortalidade , Choque Séptico/mortalidade , Choque Séptico/fisiopatologia , Choque Séptico/terapia , Taxa de Sobrevida , Resultado do Tratamento , Utah/epidemiologia , Vasoconstritores/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA