Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 256
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39011961

RESUMO

INTRODUCTION: Patients with viral myocarditis can present with challenging life-threatening arrhythmias. Catheter ablation can be a life-saving procedure in some patients with recurrent drug-refractory ventricular arrhythmias. METHODS AND RESULTS: A patient with three prior ablations targeting two different monomorphic ventricular tachycardias (MMVTs) presented with recurrent ventricular tachycardia (VT). Consequently, he underwent epicardial mapping with adjuvant AI-enabled CT images with the creation of a three-dimensional model, which demonstrated a midmyocardial scar. Fractionated potentials were noted during mapping in this region, and entrainment suggested an inner loop. Interestingly, pacing showed two different QRS morphologies identical to his previously ablated VTs with a long stim-QRS at this region. Epicardial ablation carried on during the VT successfully terminated it, but the VT remained inducible and required endocardial ablation to make it noninducible. CONCLUSION: This case emphasizes the importance of recognizing possible three-dimensional VT circuits in some patients and the need to understand and target mid-myocardial substrate from both the endocardium and epicardium to achieve the elimination of the VT circuits.

2.
J Cardiovasc Electrophysiol ; 35(5): 994-1004, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38501333

RESUMO

INTRODUCTION: When ventricular tachycardia (VT) recurs after standard RF ablation (sRFA) some patients benefit from repeat sRFA, whereas others warrant advanced methods such as intramural needle ablation (INA). Our objectives are to assess the utility of repeat sRFA and to clarify the benefit of INA when repeat sRFA fails in patients with VT due to structural heart disease. METHODS: In consecutive patients who were prospectively enrolled in a study for INA for recurrent sustained monomorphic VT despite sRFA, repeat sRFA was considered first. INA was performed during the same procedure if repeat sRFA failed or no targets for sRFA were identified. RESULTS: Of 85 patients enrolled, acute success with repeat sRFA was achieved in 30 patients (35%), and during the 6-month follow-up, 87% (20/23) were free of VT hospitalization, 78% were free of any VT, and 7 were lost to follow-up. INA was performed in 55 patients (65%) after sRFA failed, or no endocardial targets were found abolished or modified inducible VT in 35/55 patients (64%). During follow-up, 72% (39/54) were free of VT hospitalization, 41% were free of any VT, and 1 was lost to follow-up. Overall, 59 out of 77 (77%) patients were free of hospitalization and 52% were free of any VT. Septal-origin VTs were more likely to need INA, whereas RV and papillary muscle VTs were less likely to require INA. CONCLUSIONS: Repeat sRFA was beneficial in 23% (18/77) of patients with recurrent sustained VT who were referred for INA. The availability of INA increased favorable outcomes to 52%.


Assuntos
Ablação por Cateter , Cicatriz , Recidiva , Reoperação , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Ablação por Cateter/efeitos adversos , Cicatriz/fisiopatologia , Cicatriz/diagnóstico , Cicatriz/cirurgia , Cicatriz/etiologia , Fatores de Tempo , Potenciais de Ação , Agulhas , Frequência Cardíaca , Fatores de Risco , Resultado do Tratamento
3.
Artigo em Inglês | MEDLINE | ID: mdl-38994680

RESUMO

INTRODUCTION: Scar substrate in nonischemic cardiomyopathy (NICM) patients is often difficult to identify. Advances in cardiac imaging, especially using late iodine-enhanced computed tomography (LIE-CT), allow better characterization of scars giving rise to ventricular tachycardia (VT). Currently, there are limited data on clinical correlates of CT-derived scar substrates in NICM. We sought assess the relationship between scar location on LIE-CT and outcomes after radiofrequency catheter ablation (RFCA) in NICM patients with VT. METHODS: From 2020 to 2022, consecutive patients with NICM undergoing VT RFCA with integration of cardiac CT scar modeling (inHeart, Pessac, France) were included at two US tertiary care centers. The CT protocol included both arterial-enhanced imaging for anatomical modeling and LIE-CT for scar assessment. The distribution of substrate on CT was analyzed in relation to patient outcomes, with primary endpoints being VT recurrence and the need for repeat ablation procedure. RESULTS: Sixty patients were included (age 64 ± 12 years, 90% men). Over a median follow-up of 120 days (interquartile range [IQR]: 41-365), repeat ablation procedures were required in 32 (53%). VT recurrence occurred in 46 (77%), with a median time to recurrence of 40 days (IQR: 8-65). CT-derived total scar volume positively correlated with intrinsic QRS duration (r = .34, p = 0.008). Septal scar was found on CT in 34 (57%), and lateral scar in 40 (7%). On univariate logistic regression, septal scar was associated with increased odds of repeat ablation (odds ratio [OR]: 2.9 [1.0-8.4]; p = 0.046), while lateral scar was not (OR: 0.9 [0.3-2.7]; p = 0.855). Septal scar better predicted VT recurrence when compared to lateral scar, but neither were statistically significant (septal scar OR: 3.0 [0.9-10.7]; p = 0.078; lateral scar OR: 1.7 [0.5-5.9]; p = 0.391). CONCLUSION: In this tertiary care referral population, patients with NICM undergoing VT catheter ablation with septal LIE-CT have nearly threefold increased risk of need for repeat ablation.

4.
J Cardiovasc Electrophysiol ; 35(8): 1645-1655, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38924224

RESUMO

INTRODUCTION: Training in clinical cardiac electrophysiology (CCEP) involves the development of catheter handling skills to safely deliver effective treatment. Objective data from analysis of ablation data for evaluating trainee of CCEP procedures has not previously been possible. Using the artificial intelligence cloud-based system (CARTONET), we assessed the impact of trainee progress through ablation procedural quality. METHODS: Lesion- and procedure-level data from all de novo atrial fibrillation (AF) and cavotricuspid isthmus (CTI) ablations involving first-year (Y1) or second-year (Y2) fellows across a full year of fellowship was curated within Cartonet. Lesions were automatically assigned to anatomic locations. RESULTS: Lesion characteristics, including contact force, catheter stability, impedance drop, ablation index value, and interlesion time/distance were similar over each training year. Anatomic location and supervising operator significantly affected catheter stability. The proportion of lesion sets delivered independently and of lesions delivered by the trainee increased steadily from the first quartile of Y1 to the last quartile of Y2. Trainee perception of difficult regions did not correspond to objective measures. CONCLUSION: Objective ablation data from Cartonet showed that the progression of trainees through CCEP training does not impact lesion-level measures of treatment efficacy (i.e., catheter stability, impedance drop). Data demonstrates increasing independence over a training fellowship. Analyses like these could be useful to inform individualized training programs and to track trainee's progress. It may also be a useful quality assurance tool for ensuring ongoing consistency of treatment delivered within training institutions.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Competência Clínica , Educação de Pós-Graduação em Medicina , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Curva de Aprendizado , Técnicas Eletrofisiológicas Cardíacas , Inteligência Artificial , Fatores de Tempo , Resultado do Tratamento , Bolsas de Estudo , Cardiologistas/educação , Eletrofisiologia Cardíaca/educação , Cateteres Cardíacos
5.
J Cardiovasc Electrophysiol ; 35(10): 1962-1971, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39113311

RESUMO

INTRODUCTION: High-frequency low-tidal-volume (HFLTV) ventilation during radiofrequency catheter ablation (RFCA) for paroxysmal atrial fibrillation (PAF) has been shown to be superior to standard ventilation (SV) in terms of procedural efficiency, acute and long-term clinical outcomes. Our study aimed to compare ablation lesions characteristics utilizing HFLTV ventilation versus SV during RFCA of PAF. METHODS: A retrospective analysis was conducted on patients who underwent pulmonary vein isolation (PVI) for PAF between August 2022 and March 2023, using high-power short-duration ablation. Thirty-five patients underwent RFCA with HFLTV ventilation and were matched with another cohort of 35 patients who underwent RFCA with SV. Parameters including ablation duration, contact force (CF), impedance drop, and ablation index were extracted from the CARTONET database for each ablation lesion. RESULTS: A total of 70 patients were included (HFLTV = 35/2484 lesions, SV = 35/2830 lesions) in the analysis. There were no differences in baseline characteristics between the groups. While targeting the same ablation index, the HFLTV ventilation group demonstrated shorter average ablation duration per lesion (12.3 ± 5.0 vs. 15.4 ± 8.4 s, p < .001), higher average CF (17.0 ± 8.5 vs. 10.5 ± 4.6 g, p < .001), and greater impedance reduction (9.5 ± 4.6 vs. 7.7 ± 4.1 ohms, p < .001). HFLTV ventilation group also demonstrated shorter total procedural time (61.3 ± 25.5 vs. 90.8 ± 22.8 min, p < .001), ablation time (40.5 ± 18.6 vs. 65.8 ± 22.5 min, p < .001), and RF time (15.3 ± 4.8 vs. 22.9 ± 9.7 min, p < .001). CONCLUSION: HFLTV ventilation during PVI for PAF was associated with improved ablation lesion parameters and procedural efficiency compared to SV.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Frequência Cardíaca , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Feminino , Masculino , Ablação por Cateter/efeitos adversos , Estudos Retrospectivos , Pessoa de Meia-Idade , Resultado do Tratamento , Idoso , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Fatores de Tempo , Potenciais de Ação , Bases de Dados Factuais
6.
Europace ; 24(4): 598-605, 2022 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-34791165

RESUMO

AIM: To describe clinical characteristics, procedural details, specific challenges, and outcomes in patients with HeartMate3™ (HM3), a left ventricular assist device system with a magnetically levitated pump, undergoing ventricular tachycardia ablation (VTA). METHODS AND RESULTS: Data were collected from patients with an HM3 system who underwent VTA in seven tertiary centres. Data included baseline patient characteristics, procedural data, mortality, and arrhythmia-free survival. The study cohort included 19 patients with cardiomyopathy presenting with ventricular tachycardia (VT) (53% with VT storm). Ventricular tachycardias were induced in 89% of patients and a total of 41 VTs were observed. Severe electromagnetic interference was present on the surface electrocardiogram. Hence, VT localization required analysis of intra-cardiac signals or the use of filter in the 40-20 Hz range. The large house pump HM3 design obscured the cannula inflow and therefore multi imaging modalities were necessary to avoid catheter entrapment in the cannula. A total of 32 VTs were mapped and were successfully ablated (31% to the anterior wall, 38% to the septum and only 9% to the inflow cannula region). Non-inducibility of any VT was reached in 11 patients (58%). Over a follow-up of 429 (interquartile range 101-692) days, 5 (26%) patients underwent a redo VT ablation due to recurrent VTA and 2 (11%) patients died. CONCLUSIONS: Ventricular tachycardia ablation in patients with HM3 is feasible and safe when done in the appropriate setup. Long-term arrhythmia-free survival is acceptable but not well predicted by non-inducibility at the end of the procedure.


Assuntos
Cardiomiopatias , Ablação por Cateter , Coração Auxiliar , Taquicardia Ventricular , Cardiomiopatias/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Recidiva , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
7.
Pacing Clin Electrophysiol ; 45(9): 1124-1131, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35621224

RESUMO

AIMS: To compare the cost of cardiac stereotactic body radioablation therapy (SBRT) versus catheter ablation for treating ventricular tachycardia (VT). BACKGROUND: Cardiac SBRT is a novel way of treating refractory VT that may be less costly than catheter ablation, owing to its noninvasive, outpatient nature. However, the true costs of either procedure are not well described, which could help inform a more appropriate reimbursement for cardiac SBRT than simply cross-indexing existing procedural rates. METHODS: Process maps were derived for the full patient care cycle of both procedures using time-driven activity-based costing. Step-by-step timestamps were collected prospectively from a 10-patient SBRT cohort and retrospectively from a 59-patient catheter ablation cohort. Individual costs were estimated by multiplying timestamps with capacity cost rates (CCRs) for personnel, space, equipment, consumable, and indirect resources. These were summed into total cost, which for cardiac SBRT was compared with current catheter ablation and single-fraction lung SBRT reimbursements, both potential reference rates for cardiac SBRT. RESULTS: The direct and total procedural costs of cardiac SBRT ($7549 and $10,621) were 49% and 54% less than those of VT ablation ($14,707 and $23,225). These costs were significantly different from current reimbursement for catheter ablation ($22,692) and lung SBRT ($6329). After including hospitalization expenses (≥$15,000), VT ablation costs at least $27,604 more to furnish than cardiac SBRT. CONCLUSIONS: Time-driven activity-based costing (TDABC) can be a helpful tool for assessing healthcare costs, including novel treatment approaches. In addition to its clinical benefits, cardiac SBRT may provide significant cost reduction opportunities for treatment of VT.


Assuntos
Ablação por Cateter , Radiocirurgia , Taquicardia Ventricular , Antiarrítmicos/uso terapêutico , Ablação por Cateter/métodos , Humanos , Radiocirurgia/métodos , Estudos Retrospectivos , Resultado do Tratamento
8.
Rheumatol Int ; 42(10): 1767-1774, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35430712

RESUMO

COVID-19 raised concern regarding cardiotoxicity and QTc prolongation of hydroxychloroquine (HCQ) and chloroquine (CQ). We examined the frequency and patient factors associated with ECG testing and the detection of prolonged QTc among new HCQ/CQ users in a large academic medical system. 10,248 subjects with a first HCQ/CQ prescription (1/2015-3/2020) were included. We assessed baseline (1 year prior to and including day of initiation of HCQ/CQ through 2 months after initial HCQ/CQ prescription) and follow-up (10 months after the baseline period) patient characteristics and ECGs obtained from electronic health records. Among 8384 female HCQ/CQ new users, ECGs were obtained for 22.3%, 14.3%, and 7.6%, at baseline, follow, and both periods, respectively. Among 1864 male HCQ/CQ new users, ECGs were obtained more frequently at baseline (29.7%), follow-up (18.0%), and both periods (11.3%). Female HCQ/CQ users with a normal QTc at baseline but prolonged QTc (> 470 ms) at follow-up (13.1%) were older at HCQ/CQ initiation [mean 64.7 (SD 16.5) vs. 58.7 (SD 16.9) years, p = 0.004] and more likely to have history of myocardial infarction (41.0% vs. 21.6%, p = 0.0003) compared to those who had normal baseline and follow-up QTc. The frequency of prolonged QTc development was similar (12.4%) among male HCQ/CQ new users (> 450 ms). Prior to COVID-19, ECG testing before and after HCQ/CQ prescription was infrequent, particularly for females who are disproportionately affected by rheumatic diseases and were just as likely to develop prolonged QTc (> 1/10 new users). Prospective studies are needed to guide future management of HCQ/CQ therapy in rheumatic populations.


Assuntos
Tratamento Farmacológico da COVID-19 , COVID-19 , Hidroxicloroquina , COVID-19/epidemiologia , Cloroquina/efeitos adversos , Eletrocardiografia , Feminino , Humanos , Hidroxicloroquina/efeitos adversos , Masculino , Prevalência , SARS-CoV-2 , Centros de Atenção Terciária
9.
N Engl J Med ; 388(1): 71-78, 2023 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-36599065
10.
J Cardiovasc Electrophysiol ; 32(11): 2901-2914, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34587335

RESUMO

INTRODUCTION: Despite advances in drug and catheter ablation therapy, long-term recurrence rates for ventricular tachycardia remain suboptimal. Cardiac stereotactic body radiotherapy (SBRT) is a novel treatment that has demonstrated reduction of arrhythmia episodes and favorable short-term safety profile in treatment-refractory patients. Nevertheless, the current clinical experience is early and limited. Recent studies have highlighted variable duration of treatment effect and substantial recurrence rates several months postradiation. Contributing to these differential outcomes are disparate approaches groups have taken in planning and delivering radiation, owing to both technical and knowledge gaps limiting optimization and standardization of cardiac SBRT. METHODS AND FINDINGS: In this report, we review the historical basis for cardiac SBRT and existing clinical data. We then elucidate the current technical gaps in cardiac radioablation, incorporating the current clinical experience, and summarize the ongoing and needed efforts to resolve them. CONCLUSION: Cardiac SBRT is an emerging therapy that holds promise for the treatment of ventricular tachycardia. Technical gaps remain, to be addressed by ongoing research and growing clincial experience.


Assuntos
Ablação por Cateter , Radiocirurgia , Taquicardia Ventricular , Arritmias Cardíacas , Ablação por Cateter/efeitos adversos , Coração , Humanos , Radiocirurgia/efeitos adversos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia
11.
J Cardiovasc Electrophysiol ; 32(2): 409-416, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33355965

RESUMO

INTRODUCTION: Patients with prior cardiac surgery may represent a subgroup of patients with ventricular tachycardia (VT) that may be more difficult to control with catheter ablation. METHODS: We evaluated 1901 patients with ischemic and nonischemic cardiomyopathy who underwent VT ablation at 12 centers. Clinical characteristics and VT radiofrequency ablation procedural outcomes were assessed and compared between those with and without prior cardiac surgery. Kaplan-Meier analysis was used to estimate freedom from recurrent VT and survival. RESULTS: There were 578 subjects (30.4%) with prior cardiac surgery identified in the cohort. Those with prior cardiac surgery were older (66.4 ± 11.0 years vs. 60.5 ± 13.9 years, p < .01), with lower left ventricular ejection fraction (30.2 ± 11.5% vs. 34.8 ± 13.6%, p < .01) and more ischemic heart disease (82.5% vs. 39.3%, p < .01) but less likely to undergo epicardial mapping or ablation (9.0% vs. 38.1%, p<.01) compared to those without prior surgery. When epicardial mapping was performed, a significantly greater proportion required surgical intervention for access (19/52 [36.5%] vs. 14/504 [2.8%]; p < .01). Procedural complications, including epicardial access-related complications, were lower (5.7% vs. 7.0%, p < .01) in patients with versus without prior cardiac surgery. VT-free survival (75.1% vs. 74.1%, p = .805) and survival (86.5% vs. 87.9%, p = .397) were not different between those with and without prior heart surgery, regardless of etiology of cardiomyopathy. VT recurrence was associated with increased mortality in patients with and without prior cardiac surgery. CONCLUSION: Despite different clinical characteristics and fewer epicardial procedures, the safety and efficacy of VT ablation in patients with prior cardiac surgery is similar to others in this cohort. The incremental yield of epicardial mapping in predominant ischemic cardiomyopathy population prior heart surgery may be low but appears safe in experienced centers.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ablação por Cateter , Taquicardia Ventricular , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ablação por Cateter/efeitos adversos , Humanos , Pericárdio/cirurgia , Recidiva , Volume Sistólico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento , Função Ventricular Esquerda
12.
Circulation ; 140(4): 293-302, 2019 07 23.
Artigo em Inglês | MEDLINE | ID: mdl-31155932

RESUMO

BACKGROUND: An accurate estimation of the risk of life-threatening (LT) ventricular tachyarrhythmia (VTA) in patients with LMNA mutations is crucial to select candidates for implantable cardioverter-defibrillator implantation. METHODS: We included 839 adult patients with LMNA mutations, including 660 from a French nationwide registry in the development sample, and 179 from other countries, referred to 5 tertiary centers for cardiomyopathies, in the validation sample. LTVTA was defined as (1) sudden cardiac death or (2) implantable cardioverter defibrillator-treated or hemodynamically unstable VTA. The prognostic model was derived using the Fine-Gray regression model. The net reclassification was compared with current clinical practice guidelines. The results are presented as means (SD) or medians [interquartile range]. RESULTS: We included 444 patients, 40.6 (14.1) years of age, in the derivation sample and 145 patients, 38.2 (15.0) years, in the validation sample, of whom 86 (19.3%) and 34 (23.4%) experienced LTVTA over 3.6 [1.0-7.2] and 5.1 [2.0-9.3] years of follow-up, respectively. Predictors of LTVTA in the derivation sample were: male sex, nonmissense LMNA mutation, first degree and higher atrioventricular block, nonsustained ventricular tachycardia, and left ventricular ejection fraction (https://lmna-risk-vta.fr). In the derivation sample, C-index (95% CI) of the model was 0.776 (0.711-0.842), and the calibration slope 0.827. In the external validation sample, the C-index was 0.800 (0.642-0.959), and the calibration slope was 1.082 (95% CI, 0.643-1.522). A 5-year estimated risk threshold ≥7% predicted 96.2% of LTVTA and net reclassified 28.8% of patients with LTVTA in comparison with the guidelines-based approach. CONCLUSIONS: In comparison with the current standard of care, this risk prediction model for LTVTA in laminopathies significantly facilitated the choice of candidates for implantable cardioverter defibrillators. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03058185.


Assuntos
Cardiomiopatias/complicações , Desfibriladores Implantáveis/efeitos adversos , Taquicardia Ventricular/etiologia , Adulto , Feminino , Humanos , Masculino , Taquicardia Ventricular/patologia , Estudos de Validação como Assunto
13.
Europace ; 22(11): 1680-1687, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32830247

RESUMO

AIMS: Catheter ablation is an effective treatment for post-infarction ventricular tachycardia (VT). However, some patients may experience a worsened arrhythmia phenotype after ablation. We aimed to determine the prevalence and prognostic impact of arrhythmia exacerbation (AE) after post-infarction VT ablation. METHODS AND RESULTS: A total of 1187 consecutive patients (93% men, median age 68 years, median ejection fraction 30%) who underwent post-infarction VT ablation at six centres were included. Arrhythmia exacerbation was defined as post-ablation VT storm or incessant VT in patients without prior similar events. During follow-up (median 717 days), 426 (36%) patients experienced VT recurrence. Events qualifying as AE occurred in 67 patients (6%). Median times to VT recurrence with and without AE were 238 [interquartile range (IQR) 35-640] days and 135 (IQR 22-521) days, respectively (P = 0.25). Almost half of the patients (46%) who experienced AE experienced it within 6 months of the index procedure. Patients with AE had had longer ablation times during the ablation procedures compared to the rest of the patients (median 42 vs. 34 min, P = 0.02). Among patients with VT recurrence, the risk of death or heart transplantation was significantly higher in patients with than without AE (hazard ratio 1.99, 95% CI 1.28-3.10; P = 0.002) after adjusting for age, gender, ejection fraction, cardiac resynchronization therapy, post-ablation non-inducibility, and post-ablation amiodarone use. CONCLUSION: Arrhythmia exacerbation after ablation of infarct-related VT is infrequent but is independently associated with an adverse long-term outcome among patients who experience a VT recurrence. The mechanisms and mitigation strategies of AE after catheter ablation require further investigation.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Idoso , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Infarto , Masculino , Prevalência , Prognóstico , Recidiva , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/etiologia , Resultado do Tratamento
14.
Europace ; 22(3): 450-495, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31995197

RESUMO

Ventricular arrhythmias are an important cause of morbidity and mortality and come in a variety of forms, from single premature ventricular complexes to sustained ventricular tachycardia and fibrillation. Rapid developments have taken place over the past decade in our understanding of these arrhythmias and in our ability to diagnose and treat them. The field of catheter ablation has progressed with the development of new methods and tools, and with the publication of large clinical trials. Therefore, global cardiac electrophysiology professional societies undertook to outline recommendations and best practices for these procedures in a document that will update and replace the 2009 EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias. An expert writing group, after reviewing and discussing the literature, including a systematic review and meta-analysis published in conjunction with this document, and drawing on their own experience, drafted and voted on recommendations and summarized current knowledge and practice in the field. Each recommendation is presented in knowledge byte format and is accompanied by supportive text and references. Further sections provide a practical synopsis of the various techniques and of the specific ventricular arrhythmia sites and substrates encountered in the electrophysiology lab. The purpose of this document is to help electrophysiologists around the world to appropriately select patients for catheter ablation, to perform procedures in a safe and efficacious manner, and to provide follow-up and adjunctive care in order to obtain the best possible outcomes for patients with ventricular arrhythmias.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Eletrofisiologia Cardíaca , Consenso , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia
16.
Europace ; 21(8): 1143-1144, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-31075787

RESUMO

Ventricular arrhythmias are an important cause of morbidity and mortality and come in a variety of forms, from single premature ventricular complexes to sustained ventricular tachycardia and fibrillation. Rapid developments have taken place over the past decade in our understanding of these arrhythmias and in our ability to diagnose and treat them. The field of catheter ablation has progressed with the development of new methods and tools, and with the publication of large clinical trials. Therefore, global cardiac electrophysiology professional societies undertook to outline recommendations and best practices for these procedures in a document that will update and replace the 2009 EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias. An expert writing group, after reviewing and discussing the literature, including a systematic review and meta-analysis published in conjunction with this document, and drawing on their own experience, drafted and voted on recommendations and summarized current knowledge and practice in the field. Each recommendation is presented in knowledge byte format and is accompanied by supportive text and references. Further sections provide a practical synopsis of the various techniques and of the specific ventricular arrhythmia sites and substrates encountered in the electrophysiology lab. The purpose of this document is to help electrophysiologists around the world to appropriately select patients for catheter ablation, to perform procedures in a safe and efficacious manner, and to provide follow-up and adjunctive care in order to obtain the best possible outcomes for patients with ventricular arrhythmias.


Assuntos
Eletrofisiologia Cardíaca , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas/métodos , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Eletrofisiologia Cardíaca/organização & administração , Eletrofisiologia Cardíaca/normas , Eletrofisiologia Cardíaca/tendências , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Ablação por Cateter/normas , Consenso , Sistema de Condução Cardíaco/patologia , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Cardiopatias/classificação , Cardiopatias/complicações , Humanos , Cooperação Internacional , Melhoria de Qualidade/organização & administração , Sociedades Médicas , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Resultado do Tratamento , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/etiologia , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/cirurgia
17.
Heart Lung Circ ; 28(1): 123-133, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30554598

RESUMO

Cardiac electrical storm (ES) is characterised by three or more discrete episodes of ventricular arrhythmia within 24hours, or incessant ventricular arrhythmia for more than 12hours. ES is a distinct medical emergency that portends a significant increase in mortality risk and often presages progressive heart failure. ES is also associated with psychological morbidity from multiple implanted cardioverter defibrillator (ICD) shocks and exponential health resource utilisation. Up to 30% of ICD recipients may experience storm in follow-up, with the risk higher in patients with a secondary prevention ICD indication. Storm recurs in a high proportion of patients after an initial episode, and multiple storm clusters may occur in follow-up. The mechanism of storm remains elusive but is likely influenced by a complex interplay of inciting triggers (e.g., ischaemia, electrolyte disturbances), with autonomic perturbations acting on a vulnerable structural and electrophysiologic substrate. Triggers can be identified only in a minority of patients. An emergent treatment approach is warranted, if possible with emergent transfer to a high-volume centre for ventricular arrhythmia management with a multi-modality approach including ICD reprogramming, sympathetic blockade (sedation, intubation, ventilation, beta blockers), and anti-arrhythmic drugs, and adjunctive intervention techniques, such as catheter ablation and neuraxial modulation (e.g., thoracic epidural anaesthesia, stellate ganglion block). Outcomes of catheter ablation of ES are excellent with resolution of storm in over 90% of patients at 1year with a low complication rate (∼2%). ES may occur in the absence of structural heart disease in the context of channelopathies, Brugada syndrome, early repolarisation and premature ventricular contraction-induced ventricular fibrillation. There are unique treatment approaches to these conditions that must be recognised. This state-of-the-art review will summarise the incidence, mechanism, and multi-modality treatment of ES in the contemporary era.


Assuntos
Arritmias Cardíacas/terapia , Terapia de Ressincronização Cardíaca/métodos , Gerenciamento Clínico , Sistema de Condução Cardíaco/fisiopatologia , Arritmias Cardíacas/fisiopatologia , Humanos
18.
J Cardiovasc Electrophysiol ; 29(1): 79-89, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28940781

RESUMO

BACKGROUND: Right ventricular (RV)-scar related ventricular tachycardia (VT) is often due to arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVC/D) or cardiac sarcoidosis (CS), but some patients whose clinical course has not been described do not fulfill diagnostic criteria for these diseases. We sought to characterize the electrophysiologic substrate and catheter ablation outcomes of such patients, termed RV cardiomyopathy of unknown source (RCUS). METHODS AND RESULTS: Data of 100 consecutive patients who presented with RV cardiomyopathy and/or RV-related VT for ablation were reviewed (51 ARVC/D, 22 CS; 27 RCUS). Compared to ARVC/D, RCUS patients were older (P = 0.001), less commonly had RV dilatation (P = 0.001) or dysfunction (P = 0.01) and fragmented QRS, parietal block, and T-wave inversion. Compared to CS, R-CUS patients had less severe LV dysfunction. Extent and distribution of endocardial/epicardial scar and inducible VTs in RCUS patients were comparable with ARVC/D and CS patients. At a median follow-up of 23 months, RCUS patients had more favorable VT-free survival (RCUS 71%, ARVC/D 60%, CS 41%, P = 0.03) and survival free of death or cardiac transplant (RCUS 92%, ARVC/D 92%, CS 62%, P = 0.01). No RCUS patients developed new criteria for ARVC/D or CS in follow-up. CONCLUSIONS: Up to one-third of patients with RV scar-related VT are not classifiable as ARVC/D or CS. These patients had a somewhat better prognosis than ARVC/D or sarcoid and did not develop evidence of these diseases during the initial 2 years of follow-up. The extent to which this population comprises mild ARVC/D, CS, or other diseases is not clear.


Assuntos
Cardiomiopatias/complicações , Ablação por Cateter , Frequência Cardíaca , Ventrículos do Coração/cirurgia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Função Ventricular Direita , Potenciais de Ação , Adulto , Displasia Arritmogênica Ventricular Direita/diagnóstico , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Cardiomiopatias/diagnóstico , Cardiomiopatias/fisiopatologia , Ablação por Cateter/efeitos adversos , Diagnóstico Diferencial , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Sarcoidose/diagnóstico , Sarcoidose/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
19.
J Cardiovasc Electrophysiol ; 29(6): 854-860, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29570900

RESUMO

INTRODUCTION: Atrial fibrillation (AF) ablation is increasingly common, but is associated with potential major complications. Technology, experience, and protocols have evolved significantly in recent times, and may have impacted procedural safety. We sought to compare AF ablation safety profiles, including complication rates and fluoroscopy times in a "modern" versus "historical" cohort. METHODS AND RESULTS: We evaluated consecutive patients undergoing AF ablation from a modern cohort (MC) from 2014 to 2015 and a historic cohort (HC) from 2009 to 2011 for complications. Major complications were categorized according to Heart Rhythm Society guidelines. We included 1,425 patients, 726 in the HC and 699 in the MC. The MC was older, had more OSA and less valvular AF. Fifty-two (3.5%) procedures suffered major complications across the cohorts, with significantly fewer in the MC (5.0% vs. 2.3%, P  =  0.007). The largest reductions were seen in vascular, hemorrhagic, ischemic stroke, and perforation/tamponade related complications. Periprocedural antiplatelets drugs (aHR 2.1 [95 CI 1.1-3.9], P  =  0.02) and force-sensing catheters (aHR 0.4 [95 CI 0.2-0.9], P  =  0.03) were independently related to major complication rates. Direct oral anticoagulants and uninterrupted anticoagulation were not associated with complications. There was a decrease in both fluoroscopy (-17.4 minutes [95 CI 19.2-15.6], P < 0.0001) and radiofrequency ablation times (-561 seconds [95CI -750 to -371], P < 0.0001). CONCLUSIONS: The safety profile of AF ablation has improved significantly in less than a decade.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/tendências , Complicações Pós-Operatórias/prevenção & controle , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Bases de Dados Factuais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Radiografia Intervencionista/tendências , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA