Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Occup Environ Hyg ; 12(8): D178-83, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25789600

RESUMO

This study investigated the particle and fiber release from two carbon fiber reinforced polymer cables that underwent high-energy tensile tests until rupture. The failing event was the source of a large amount of dust whereof a part was suspected to be containing possibly respirable fibers that could cause adverse health effects. The released fibers were suspected to migrate through small openings to the experiment control room and also to an adjacent machine hall where workers were active. To investigate the fiber release and exposure risk of the affected workers, the generated particles were measured with aerosol devices to obtain the particle size and particle concentrations. Furthermore, particles were collected on filter samples to investigate the particle shape and the fiber concentration. Three situations were monitored for the control room and the machine hall: the background concentrations, the impact of the cable failure, and the venting of the exposed rooms afterward. The results showed four important findings: The cable failure caused the release of respirable fibers with diameters below 3 µm and an average length of 13.9 µm; the released particles did migrate to the control room and to the machine hall; the measured peak fiber concentration of 0.76 fibers/cm(3) and the overall fiber concentration of 0.07 fibers/cm(3) in the control room were below the Permissible Exposure Limit (PEL) for fibers without indication of carcinogenicity; and the venting of the rooms was fast and effective. Even though respirable fibers were released, the low fiber concentration and effective venting indicated that the suspected health risks from the experiment on the affected workers was low. However, the effect of long-term exposure is not known therefore additional control measures are recommended.


Assuntos
Carbono/análise , Exposição Ocupacional/análise , Material Particulado/análise , Poluentes Ocupacionais do Ar/análise , Fibra de Carbono , Poeira/análise , Monitoramento Ambiental/métodos , Teste de Materiais , Tamanho da Partícula , Polímeros/análise
2.
Biomed Eng Online ; 13: 38, 2014 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-24708695

RESUMO

BACKGROUND: The probability of in vivo failure of ceramic hip joint implants is very low (0.004-0.05%). In addition to material flaws and overloading, improper handling during implantation can induce fractures of the ceramic ball head in the long term. Identifying the causes of an in vivo fracture contributes to improved understanding and potentially to further reduction of the fracture probability for patients. Asymmetric metal markings on the cone surface of in vivo ball head fractures have been reported. The question, therefore, is whether asymmetric loading is the sole cause or whether additional factors, specifically contamination entrapped in the taper fit, also contribute or are even the main cause. METHODS: The influence of the asymmetric physiological load configuration on resulting metal markings in the cone surface of an alumina femoral ball head with and without biological contaminants was investigated. Static and cyclic tests on ball heads were carried out in a load configuration of 0° (axisymmetric) and 40° in a physiological environment. The analysis of the metal marking was carried out to gain a better understanding of the processes that contribute to the generation of metal marking. Fractography was carried out to determine the fracture initiation of failed ball heads. RESULTS: Different types and sizes of residuals entrapped in the conical surface are shown to yield strongly asymmetric metal marking patterns. All heads tested without contaminants exhibited an almost homogenous distribution of residual metal markings around the circumference of the ceramic cone surface at the proximal end of the bore hole. The failure of ball heads that contained entrapped contaminants revealed a common fracture pattern. The site of fracture initiation on two of the failed heads was in the entrance region of the bore hole on the superior half of the head. CONCLUSION: Asymmetric metal markings observed on the ball heads tested in this investigation are most probably caused by the presence of contaminants entrapped in the taper fit. Homogenous metal mark distributions around the circumference indicate proper assembly of the ball head without entrapped contaminants. It should, however, be noted that different taper designs may possibly result in different marking patterns.


Assuntos
Cerâmica , Cabeça do Fêmur , Fenômenos Mecânicos , Metais , Falha de Prótese , Teste de Materiais , Propriedades de Superfície
3.
Polymers (Basel) ; 14(24)2022 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-36559898

RESUMO

This paper presents a finite element (FE) analysis of an anchor for prestressing of sand-coated carbon-fiber-reinforced polymer (CFRP) tendons during the manufacturing of precast elements. This anchorage is temporary and removed after 2 to 7 days, when the pretensioning is released and the concrete is finally compressed. The investigated anchor consists of a conical metal barrel and three polymer wedges. The main tendon material properties are measured, compared with theoretical values and define the basis for the FE model. The latter considers both steps, pressing-in of the wedges and the subsequent loading of the tendon (diameter 7.5 mm). The relatively soft contact between polymer wedge and sand-coating is characterized experimentally and implemented with a pressure-overclosure condition. For the validation of the FE model, the strain distribution in the tendon is measured using fiber optical sensing. The therefore crucial process of fiber integration is described, and a novel approach is presented to uncover the optical fiber. The strain distribution of a sample with two anchors loaded in tension up to 80 kN is presented. The stress concentration at the front of the anchorage is highlighted. In addition, the finite element model is compared with the experiment, showing a good agreement of the strain distribution. A failure criterion according to Puck is finally implemented, which allows to assess potential fiber or interfiber failure.

4.
Polymers (Basel) ; 14(13)2022 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-35808733

RESUMO

The application of CFRP bar and seawater sea-sand concrete (SSSC) in construction can overcome the shortcomings in conventional reinforced concrete, such as corrosion induced by carbonation and chloride ingress. In this study, the bond-slip behavior between an SSSC cube and CFRP bar has been investigated, and different CFRP bar surface shapes have been considered. A total of 27 specimens (9 groups) were fabricated for a pull-out test, where three types of CFRP bar with different surface shapes were used: smooth regular bars, double-wrapped bars and ribbed bars. Bond strength, bond-slip curve, and failure mode have been presented and discussed. FE models have been constructed and validated by experimental results. The effect of concrete compressive strength and relative area of ribs on bond strength has been studied through numerical simulations. It is found that the bond strength increased with concrete compressive strength, and the ribbed bar had significantly higher bond strength than the smooth regular bar. Pull-out failure was observed when the cover-depth-to-bar-diameter ratio was no less than 4 and, otherwise, splitting failure occurred. In addition, a simple formula has been proposed to approximately evaluate the bond strength between an SSSC cube and CFRP bar and validated by experimental results, and analytical expressions for different bond-slip curves have also been developed.

5.
Polymers (Basel) ; 14(20)2022 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-36297836

RESUMO

The focus of this research is an investigation on the fatigue behaviour of unidirectional 3D-printed continuous carbon fibre-reinforced polymer (CFRP) tension straps with a polyamide matrix (PA12). Conventionally produced tension straps are becoming established components in the mechanical as well as the civil engineering sector, e.g., as rigging systems for sailing boats and cranes and-recently introduced-as network arch bridge hangers. All these structures are subjected to high fatigue loads, and although it is commonly reported that carbon fibre-reinforced polymers show excellent fatigue resistance, there is limited understanding of the behaviour of CFRP loop elements under such loads, especially in combination with fretting at the attachment points. Research on this topic was performed at Empa in the past decade on thermoset CFRP straps, but never before with 3D-printed continuous CFRP straps with a thermoplastic matrix. This paper examines an additive manufacturing and post-consolidation method for producing the straps and presents initial results on their fatigue performance, which show that the fatigue endurance limit of the investigated 3D-printed and post-consolidated CFRP strap design is acceptable, when compared to steel tendons. However, it is still 20% lower than conventionally produced CFRP straps using out-of-autoclave unidirectional carbon fibre prepregs. The reasons for these findings and potential future improvements are discussed.

6.
Polymers (Basel) ; 14(10)2022 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-35632010

RESUMO

The hanger is one of the important components for through and half-through arch bridges. Conventional steel hangers are vulnerable to corrosion due to corrosive environments. Therefore, a new type of bridge hangers consisting of Carbon Fiber-Reinforced Polymer (CFRP) straps was developed recently. The CFRP straps are self-anchored, which is formed by layers-winding, and they have great advantages in corrosive environments such as high resistance to corrosion. In this study, the fatigue and fracture behavior of CFRP straps has been experimentally investigated. Firstly, the tensile testing of four CFRP strap specimens was conducted to investigate the static fracture behavior of CFRP straps, and three stages were observed, including delamination, cracking, and brittle rupture. Then, a fatigue test of thirty-nine specimens (four groups) was carried out to study the fatigue behavior of CFRP straps, where two types of pins, titanium alloy pin and CFRP pin, and two loading frequencies, 10 Hz and 15 Hz, were used. The number of cycles to failure, displacement, fatigue failure strain, outside surface temperature at the vertex of specimen, and scanning electron microscope (SEM) photographs were recorded and analyzed to investigate the fatigue behavior of CFRP straps. The experiment results show that the temperature development at the vertex of the CFRP strap varies obviously if different pins are used due to the different friction coefficients. In addition, the fatigue life of CFRP straps decreases significantly with the increase in loading rate for the titanium pin, while it only reduces slightly with the increase in loading rate for the CFRP pin.

7.
RSC Adv ; 12(29): 18425-18430, 2022 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-35799927

RESUMO

We developed a cost-effective and eco-friendly click biosynthesis of small molecule quercetin-gold quantum dots (QRT-AuQDs) involving quick conjugation using an ultrasonication method at ambient temperature by utilizing QRT and gold ions in the proportion of 0.1 : 1 (molar ratio). A comparatively very short amount of time (60 seconds) was required as compared to conventional procedures. The present biomimetics research relates to the isolation of bioactive QRT by the circularly spread silica gel layer technique (CSSGLT) and characterization (UV-Vis, FTIR, NMR and DSC analysis). Characterization of the synthesized QRT-AuQDs conjugated complex was carried out by UV-Vis, HR-TEM, DLS, zeta potential and X-ray diffraction. The main objective of the present work was to study the comparative anticancer activity of QRT and QRT-AuQDs on human lung cancer HOP-62 and leukemia K-562 cell lines. The results suggested that QRT-AuQDs showed potential for applications in anticancer treatment and were found to be a more cytotoxic agent in comparison to QRT, causing > 50% inhibition of cancer cells at the concentration < 10-7 M. Hence, small molecule conjugated QRT-AuQDs can be used as a promising material for biomedical, bioengineering and anti-infectives applications.

8.
Dalton Trans ; 51(38): 14686-14699, 2022 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-36098266

RESUMO

We report the controlled growth of biologically active compounds: gold nanoparticles (AuNPs) in various shapes, including their green synthesis, characterization, and studies of their applications towards biological, degradation and recycling. Using spectroscopic methods, studies on responsive binding mechanisms of AuNPs with biopolymers herring sperm deoxyribonucleic acid (hsDNA), bovine serum albumin (BSA), dyes degradation study, and exquisitely gold separation studies/recovery from nanowaste, COVID-19 testing kits, and pregnancy testing kits are discussed. The sensing ability of the AuNPs with biopolymers was investigated via various analytical techniques. The rate of degradation of various dyes in the presence and absence of AuNPs was studied by deploying stirring, IR, solar, and UV-Vis methods. AuNPs were found to be the most active cytotoxic agent against human breast cancer cell lines such as MCF-7 and MDAMB-468. Furthermore, an economical process for the recovery of gold traces from nanowaste, COVID-19 detection kits, and pregnancy testing kits was developed using inexpensive and eco-friendly α-cyclodextrin sugar. This method was found to be easy and safest in comparison with the universally accepted cyanidation process. In the future, small gold jewelry makers and related industries would benefit from the proposed gold-recycling process and it might contribute to their socio-economic growth. The methodologies proposed are also beneficial for trace-level forensic investigation.


Assuntos
COVID-19 , Nanopartículas Metálicas , alfa-Ciclodextrinas , COVID-19/diagnóstico , Teste para COVID-19 , Corantes , Citotoxinas , DNA , Ouro/química , Humanos , Masculino , Nanopartículas Metálicas/química , Sêmen , Soroalbumina Bovina/química , Açúcares
9.
Biomater Adv ; 134: 112540, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35525740

RESUMO

Direct ink writing (DIW) is a promising extrusion-based 3D printing technology, which employs an ink-deposition nozzle to fabricate 3D scaffold structures with customizable ink formulations for tissue engineering applications. However, determining the optimal DIW process parameters such as temperature, pressure, and speed for the specific ink is essential to achieve high reproducibility of the designed geometry and subsequent mechano-biological performance for different applications, particularly for porous scaffolds of finite sizes (total volume > 1000 mm3) and controlled pore size and porosity. The goal of this study was to evaluate the feasibility of fabricating Polycaprolactone (PCL) and bio-active glass (BG) composite-based 3D scaffolds of finite size using DIW. 3D-scaffolds were fabricated either as cylinders (10 mm diameter; 15 mm height) or cubes (5 × 5 × 5 mm3) with height/width aspect ratios of 1.5 and 1, respectively. A rheological characterization of the PCL-BG inks was performed before printing to determine the optimal printing parameters such as pressure and speed for printing at 110 °C. Microstructural properties of the scaffolds were analyzed in terms of overall scaffold porosity, and in situ pore size assessments in each layer (36 pores/layer; 1764 pores per specimen) during their fabrication. Measured porosity of the fabricated specimens-PCL: x¯ =46.94%, SD = 1.61; PCL-10 wt%BG: x¯ = 48.29%, SD = 5.95; and PCL-20 wt% BG: x¯=50.87%, SD = 2.45-matched well with the designed porosity of 50%. Mean pore sizes-PCL [x¯ = 0.37 mm (SD = 0.03)], PCL-10%BG [x¯ = 0.38 mm (SD = 0.07)] and PCL-20% BG [x¯ = 0.37 mm (SD = 0.04)]-were slightly fairly close to the designed pore size of 0.4 mm. Nevertheless there was a small but consistent, statistically significant (p < 0.0001) decrease in pore size from the first printed layer (PCL: 0.39 mm; PCL-10%BG: 0.4 mm; PCL-20%BG: 0.41 mm) to the last. SEM and micro-CT imaging revealed consistent BG particle distribution across the layers and throughout the specimens. Cell adhesion experiments revealed similar cell adhesion of PCL-20 wt% BG to pure PCL, but significantly better cell proliferation - as inferred from metabolic activity - after 7 days, although a decrease after 14 days was noted. Quasi-static compression tests showed a decrease in compressive yield strength and apparent elastic modulus with increasing BG fraction, which could be attributed to a lack of adequate mechanical bonding between the BG particles and the PCL matrix. The results show that the inks were successfully generated, and the scaffolds were fabricated with high resolution and fidelity despite their relatively large size (>1000 mm3). However, further work is required to understand the mechano-biological interaction between the BG particle additives and the PCL matrix to improve the mechanical and biological properties of the printed structures.


Assuntos
Poliésteres , Alicerces Teciduais , Poliésteres/química , Impressão Tridimensional , Reprodutibilidade dos Testes , Alicerces Teciduais/química
10.
Materials (Basel) ; 14(8)2021 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-33920364

RESUMO

The performance of pretensioned, laminated, unidirectional (UD), carbon fiber reinforced polymer (CFRP) straps, that can potentially be used for example as bridge deck suspender cables or prestressed shear reinforcements for reinforced concrete slabs and beams, was investigated at elevated temperatures. This paper aims to elucidate the effects of elevated temperature specifically on the tensile performance of pretensioned, pin-loaded straps. Two types of tests are presented: (1) steady state thermal and (2) transient state thermal. Eight steady-state target temperatures in the range of 24 °C to 600 °C were chosen, based on results from dynamic mechanical thermal analysis (DMTA) and thermogravimetric analysis (TGA). Transient state thermal tests were performed at three sustained tensile load levels, namely 10, 15, and 20 kN, corresponding to 25%, 37%, and 50% of the ultimate tensile strength of the pin-loaded straps at ambient temperature. In general, the straps were able to retain about 50% of their ambient temperature ultimate tensile strength (UTS) at 365 °C.

11.
Polymers (Basel) ; 13(19)2021 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-34641252

RESUMO

The fretting fatigue performance of laminated, unidirectional (UD), pin-loaded, carbon fibre-reinforced polymer (CFRP) straps that can be used as bridge hanger cables was investigated at a sustained service temperature of 60 °C. The aim of this paper is to elucidate the influence of the slightly elevated service temperature on the tensile fatigue performance of CFRP straps. First, steady state thermal tests at ambient temperature and at 60 °C are presented, in order to establish the behaviour of the straps at these temperatures. These results indicated that the static tensile performance of the straps is not affected by the increase in temperature. Subsequently, nine upper stress levels (USLs) between 650 and 1400 MPa were chosen in order to establish the S-N curve at 60 °C (frequency 10 Hz; R = 0.1) and a comparison with an existing S-N curve at ambient temperature was made. In general, the straps fatigue limit was slightly decreased by temperature, up to 750 MPa USL, while, for the higher USLs, the straps performed slightly better as compared with the S-N curve at ambient temperature.

12.
Polymers (Basel) ; 10(2)2018 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-30966205

RESUMO

Steel cables and suspenders in bridges are at high risk of corrosion-fatigue and in some cases of fretting-fatigue in their anchorages. These factors greatly limit the service stresses of a specific cable system and involve expensive protection measures. In order to investigate the above limitations, the fretting fatigue behaviour of pin-loaded carbon fibre reinforced polymer (CFRP) straps was studied as models for corrosion-resistant bridge suspenders. Two types of straps were tested: small model straps with a sacrificial CFRP ply and large full-scale straps. In a first phase, five fully laminated and carbon pin-loaded CFRP model straps were subjected to an ultimate tensile strength test. Thereafter, and in order to assess their durability, 20 model straps were subjected to a fretting fatigue test, which was successfully passed by 4 straps. An S-N curve was generated for a load ratio of 0.1 and a frequency of 10 Hz. In a second phase, one full-scale strap was tested for its ultimate tensile strength and two full-scale straps were fatigue-tested. The influence of fretting fatigue loading on the residual mechanical properties of the straps was also assessed, and although fretting fatigue represented an important limitation for laminated CFRP straps, it could be shown that the investigated CFRP tension members can compete with the well-established steel suspenders.

13.
Polymers (Basel) ; 9(2)2017 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-30970756

RESUMO

The bond behaviour of novel, sand-coated ultra-high modulus (UHM) carbon fibre reinforced polymers (CFRP) tendons to high performance concrete (HPC) was studied by a combined numerical and experimental approach. A series of pull-out tests revealed that the failure type can vary between sudden and continuous pull-out depending on the chosen sand coating grain size. Measuring the same shear stress vs. tendon draw-in (τ-δ) curves in the same test set-up, for sand coated CFRP tendons with a longitudinal stiffness of 137 and 509 GPa, respectively, indicated that the absolute bond strength in both cases was not influenced by the tendon's stiffness. However, the τ-δ curves significantly differed in terms of the draw-in rate, showing higher draw-in rate for the UHM CFRP tendon. With the aid of X-ray computed tomography (CT), scanning electron microscopy (SEM) and visual analysis methods, the bond failure interface was located between the CFRP tendon and the surrounding sand-epoxy layer. For further investigation, a simplified finite element analysis (FEA) of the tendon pull-out was performed using a cohesive surface interaction model and the software Abaqus 6.14. A parametric study, varying the tendon-related material properties, revealed the tendon's longitudinal stiffness to be the only contributor to the difference in the τ-δ curves found in the experiments, thus to the shear stress transfer behaviour between the CFRP tendon and the concrete. In conclusion, the excellent bond of the sand-coated UHM CFRP tendons to HPC as well as the deeper insight in the bond failure mechanism encourages the application of UHM CFRP tendons for prestressing applications.

14.
Polymers (Basel) ; 8(4)2016 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-30979220

RESUMO

This paper focuses on the fretting fatigue behaviour of pin-loaded carbon-fibre-reinforced polymer (CFRP) straps studied as models for rigging systems in sailing yachts, for suspenders of arch bridges and for pendent cables in cranes. Eight straps were subjected to an ultimate tensile strength test. In total, 26 straps were subjected to a fretting fatigue test, of which ten did not fail. An S⁻N curve was generated for a load ratio R of 0.1 and a frequency f of 10 Hz, showing a fatigue limit stress of the straps around the matrix fatigue limit, corresponding to 46% of the straps' ultimate tensile strength (σUTS). The fatigue limit was defined as 3 million load cycles (N = 3 × 106), but tests were even conducted up to N = 11.09 × 106. Catastrophic failure of the straps was initiated in their vertex areas. Investigations on the residual strength and stiffness properties of straps tested around the fatigue limit stress (for N ≥ 1 × 106) showed little influence of the fatigue loading on these properties. Quasi-static finite element analyses (FEA) were conducted. The results obtained from the FEA are in good agreement with the experiments and demonstrate a fibre parallel stress concentration in the vertex area of factor 1.3, under the realistic assumption of a coefficient of friction (cof) between pin and strap of 0.5.

15.
Polymers (Basel) ; 8(12)2016 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-30974720

RESUMO

A novel ultra-high modulus carbon fibre reinforced polymer (CFRP) prestressing tendon made from coal tar pitch-based carbon fibres was characterized in terms of high temperature tensile strength (up to 570 °C) with a series of transient thermal and steady state temperature tensile tests. Digital image correlation was used to capture the high temperature strain development during thermal and mechanical loading. Complementary thermogravimetric (TGA) and dynamic mechanical thermal (DMTA) experiments were performed on the tendons to elucidate their high temperature thermal and mechanical behaviour. The novel CFRP tendons investigated in the present study showed an ambient temperature design tensile strength of 1400 MPa. Their failure temperature at a sustained prestress level of 50% of the design tensile strength was 409 °C, which is higher than the failure temperature of most fibre reinforced polymer rebars used in civil engineering applications at similar utilisation levels. This high-temperature tensile strength shows that there is potential to use the novel high modulus CFRP tendons in CFRP pretensioned concrete elements for building applications that fulfill the fire resistance criteria typically applied within the construction industry.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA