Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Anal Chem ; 85(24): 11732-8, 2013 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-24187941

RESUMO

The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health (NIH), has developed a Standard Reference Material (SRM) to support technology development in metabolomics research. SRM 1950 Metabolites in Human Plasma is intended to have metabolite concentrations that are representative of those found in adult human plasma. The plasma used in the preparation of SRM 1950 was collected from both male and female donors, and donor ethnicity targets were selected based upon the ethnic makeup of the U.S. population. Metabolomics research is diverse in terms of both instrumentation and scientific goals. This SRM was designed to apply broadly to the field, not toward specific applications. Therefore, concentrations of approximately 100 analytes, including amino acids, fatty acids, trace elements, vitamins, hormones, selenoproteins, clinical markers, and perfluorinated compounds (PFCs), were determined. Value assignment measurements were performed by NIST and the Centers for Disease Control and Prevention (CDC). SRM 1950 is the first reference material developed specifically for metabolomics research.


Assuntos
Análise Química do Sangue/normas , Metabolômica/normas , Adulto , Aminoácidos/sangue , Biomarcadores/sangue , Carotenoides/sangue , Ácidos Graxos/sangue , Feminino , Humanos , Masculino , National Institutes of Health (U.S.) , Padrões de Referência , Estados Unidos , Vitaminas/sangue
2.
Anal Bioanal Chem ; 405(13): 4539-48, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23529413

RESUMO

The vitamin C concentrations in three food-matrix Standard Reference Materials (SRMs) from the National Institute of Standards and Technology (NIST) have been determined by liquid chromatography (LC) with absorbance detection. These materials (SRM 1549a Whole Milk Powder, SRM 1849a Infant/Adult Nutritional Formula, and SRM 3233 Fortified Breakfast Cereal) have been characterized to support analytical measurements made by food processors that are required to provide information about their products' vitamin C content on the labels of products distributed in the United States. The SRMs are primarily intended for use in validating analytical methods for the determination of selected vitamins, elements, fatty acids, and other nutrients in these materials and in similar matrixes. They can also be used for quality assurance in the characterization of test samples or in-house control materials, and for establishing measurement traceability. Within-day precision of the LC method used to measure vitamin C in the food-matrix SRMs characterized in this study ranged from 2.7% to 6.5%.


Assuntos
Ácido Ascórbico/normas , Cromatografia Líquida/normas , Suplementos Nutricionais/normas , Alimentos Formulados/normas , Ácido Ascórbico/análise , Suplementos Nutricionais/análise , Alimentos Formulados/análise , Humanos , Lactente , Controle de Qualidade , Padrões de Referência , Valores de Referência , Reprodutibilidade dos Testes
3.
Anal Bioanal Chem ; 402(2): 749-62, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22015475

RESUMO

Standard Reference Material 968e Fat-Soluble Vitamins, Carotenoids, and Cholesterol in Human Serum provides certified values for total retinol, γ- and α-tocopherol, total lutein, total zeaxanthin, total ß-cryptoxanthin, total ß-carotene, 25-hydroxyvitamin D(3), and cholesterol. Reference and information values are also reported for nine additional compounds including total α-cryptoxanthin, trans- and total lycopene, total α-carotene, trans-ß-carotene, and coenzyme Q(10). The certified values for the fat-soluble vitamins and carotenoids in SRM 968e were based on the agreement of results from the means of two liquid chromatographic methods used at the National Institute of Standards and Technology (NIST) and from the median of results of an interlaboratory comparison exercise among institutions that participate in the NIST Micronutrients Measurement Quality Assurance Program. The assigned values for cholesterol and 25-hydroxyvitamin D(3) in the SRM are the means of results obtained using the NIST reference method based upon gas chromatography-isotope dilution mass spectrometry and liquid chromatography-isotope dilution tandem mass spectrometry, respectively. SRM 968e is currently one of two available health-related NIST reference materials with concentration values assigned for selected fat-soluble vitamins, carotenoids, and cholesterol in human serum matrix. This SRM is used extensively by laboratories worldwide primarily to validate methods for determining these analytes in human serum and plasma and for assigning values to in-house control materials. The value assignment of the analytes in this SRM will help support measurement accuracy and traceability for laboratories performing health-related measurements in the clinical and nutritional communities.


Assuntos
Carotenoides/sangue , Colesterol/sangue , Vitaminas/sangue , Carotenoides/química , Colesterol/química , Cromatografia Líquida , Humanos , Estrutura Molecular , Padrões de Referência , Vitaminas/química
4.
J AOAC Int ; 94(3): 815-22, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21797009

RESUMO

The concentrations of selected fat-soluble vitamins and carotenoids in Standard Reference Material (SRM) 3280 Multivitamin/Multielement Tablets have been determined by two independent LC methods, with measurements performed by the National Institute of Standards and Technology (NIST). This SRM has been prepared as part of a collaborative effort between NIST and the National Institutes of Health Office of Dietary Supplements. The SRM is also intended to support the Dietary Supplement Ingredient Database that is being established by the U.S. Department of Agriculture. The methods used at NIST to determine the concentration levels of vitamins A and E, and beta-carotene in the SRM used RPLC with absorbance detection. The relative precision of these methods ranged from 2 to 8% for the analytes measured. SRM 3280 is primarily intended for use in validating analytical methods for the determination of selected vitamins, carotenoids, and elements in multivitamin/multielement tablets and similar matrixes.


Assuntos
Carotenoides/química , Cromatografia Líquida/métodos , Suplementos Nutricionais/análise , Gorduras/química , Vitaminas/química , Absorciometria de Fóton , Suplementos Nutricionais/normas , Padrões de Referência , Sensibilidade e Especificidade , Comprimidos/química
5.
Anal Bioanal Chem ; 392(3): 427-38, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18677464

RESUMO

As part of a collaboration with the National Institutes of Health's Office of Dietary Supplements and the Food and Drug Administration's Center for Drug Evaluation and Research, the National Institute of Standards and Technology has developed two standard reference materials (SRMs) representing different forms of saw palmetto (Serenoa repens), SRM 3250 Serenoa repens fruit and SRM 3251 Serenoa repens extract. Both of these SRMs have been characterized for their fatty acid and phytosterol content. The fatty acid concentration values are based on results from gas chromatography with flame ionization detection (GC-FID) and mass spectrometry (GC/MS) analysis while the sterol concentration values are based on results from GC-FID and liquid chromatography with mass spectrometry analysis. In addition, SRM 3250 has been characterized for lead content, and SRM 3251 has been characterized for the content of beta-carotene and tocopherols. SRM 3250 (fruit) has certified concentration values for three phytosterols, 14 fatty acids as triglycerides, and lead along with reference concentration values for four fatty acids as triglycerides and 16 free fatty acids. SRM 3251 (extract) has certified concentration values for three phytosterols, 17 fatty acids as triglycerides, beta-carotene, and gamma-tocopherol along with reference concentration values for three fatty acids as triglycerides, 17 fatty acids as free fatty acids, beta-carotene isomers, and delta-tocopherol and information values for two phytosterols. These SRMs will complement other reference materials currently available with concentrations for similar analytes and are part of a series of SRMs being developed for dietary supplements.


Assuntos
Frutas/química , Extratos Vegetais/análise , Extratos Vegetais/química , Serenoa/química , Ácidos Graxos/análise , Padrões de Referência , Esteróis/análise , Tocoferóis/química , beta Caroteno/análise
6.
J AOAC Int ; 90(4): 934-40, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17760330

RESUMO

The concentrations of caffeine and caffeine-related compounds in 2 ephedra-containing reference materials have been determined by 3 independent methods with measurements performed by the National Institute of Standards and Technology (NIST) and a collaborating laboratory. Results from the 3 methods were used for value assignment of caffeine, theobromine, and theophylline in these Standard Reference Materials (SRMs). The methods used at NIST to determine the concentration levels of caffeine, theobromine, and theophylline in SRM 3243 Ephedra-Containing Solid Oral Dosage Form and SRM 3244 Ephedra-Containing Protein Powder used reversed-phase liquid chromatography with absorbance detection and tandem mass spectrometry. These reference materials are part of the first suite in a series of NIST SRMs that provide concentration values for multiple components in dietary supplements. These SRMs are primarily intended for method validation and for use as control materials to support the analysis of dietary supplements and similar materials.


Assuntos
Cafeína/análise , Técnicas de Química Analítica/métodos , Química Farmacêutica/métodos , Cromatografia Líquida/métodos , Ephedra/química , Espectrometria de Massas/métodos , Administração Oral , Cafeína/farmacologia , Calibragem , Cromatografia Líquida de Alta Pressão , Suplementos Nutricionais/análise , Pós , Padrões de Referência , Reprodutibilidade dos Testes , Teobromina/análise , Teofilina/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA