Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
1.
Circ J ; 87(12): 1711-1719, 2023 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-37258224

RESUMO

BACKGROUND: Pulmonary vein stenosis (PVS) after PV isolation (PVI) for atrial fibrillation (AF) is a severe complication that requires angioplasty. This study aimed to compare the reduction of the cross-sectional PV area (PVA) and the incidence of PVS after cryoballoon (CB)-PVI, hot balloon (HB)-PVI, or laser balloon (LB)-PVI.Methods and Results: A total of 320 patients who underwent an initial catheter ablation procedure for AF using a CB, HB, or LB in 2 hospitals were included. They underwent contrast-enhanced multidetector CT before and 3 months after the procedure. In all 4 PVs, the reduction in PVA was more significant in the LB group than in the CB or HB groups, respectively. Moderate (50-75%) and severe (>75%) PVS were observed in 5.3% and 0.5% of the PVs, respectively. Although moderate PVS was more frequently observed in the LB group than in the CB or HB groups (8.2%, 3.8%, and 5.0%; P=0.03), the incidence of severe PVS was similar in the LB, CB, and HB groups (0.3%, 0.5%, and 1.0%; P=0.46). Symptomatic PVS requiring intervention occurred in 1 (0.3%) patient. CONCLUSIONS: Although the reduction in cross-sectional PVA and the incidence of moderate PVS after LB-PVI was more significant than after CB-PVI or HB-PVI, it rarely led to severe PVS. Symptomatic PVS requiring intervention was rare after the balloon ablation of AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Estenose de Veia Pulmonar , Humanos , Estenose de Veia Pulmonar/diagnóstico por imagem , Estenose de Veia Pulmonar/etiologia , Estudos Transversais , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Lasers
2.
Circ J ; 87(7): 939-946, 2023 06 23.
Artigo em Inglês | MEDLINE | ID: mdl-36464278

RESUMO

BACKGROUND: A recent randomized trial demonstrated that catheter ablation for atrial fibrillation (AF) in patients with heart failure with reduced ejection fraction (EF) is associated with a reduction in death or heart failure. However, the effect of catheter ablation for AF in patients with heart failure with mid-range or preserved EF is unclear.Methods and Results: We screened 899 AF patients (72.4% male, mean age 68.4 years) with heart failure and left ventricular EF ≥40% from 2 Japanese multicenter AF registries: the Atrial Fibrillation registry to Follow the long-teRm Outcomes and use of aNTIcoagulants aftER Ablation (AF Frontier Ablation Registry) as the ablation group (525 patients who underwent ablation) and the Hokuriku-Plus AF Registry as the medical therapy group (374 patients who did not undergo ablation). Propensity score matching was performed in these 2 registries to yield 106 matched patient pairs. The primary endpoint was a composite of cardiovascular death and hospitalization for heart failure. At 24.6 months, the ablation group had a significantly lower incidence of the primary endpoint (hazard ratio 0.32; 95% confidence interval 0.13-0.70; P=0.004) than the medical therapy group. CONCLUSIONS: Compared with medical therapy, catheter ablation for AF in patients with heart failure and mid-range or preserved EF was associated with a significantly lower incidence of cardiovascular death or hospitalization for heart failure.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Humanos , Masculino , Idoso , Feminino , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Volume Sistólico , Resultado do Tratamento , Insuficiência Cardíaca/terapia , Ablação por Cateter/efeitos adversos , Sistema de Registros
3.
Heart Vessels ; 38(3): 413-421, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36194289

RESUMO

The "pre-freezing" technique was a method in which a fully inflated balloon after the start of freezing was pressed against the pulmonary vein (PV) during cryoballoon ablation and has been applied especially in large-size PVs. Of 556 patients who underwent cryoballoon ablation for atrial fibrillation (AF), the pre-freezing technique was applied to 48 patients. The resulting 2:1 propensity score-matched data set included 120 patients. Using the pre-freezing technique, all left-superior PVs, all left-inferior PVs, and 95% of right-superior PVs were successfully isolated. In most right-inferior PVs, complete sealing using the pre-freezing technique was challenging, and this technique was not applied. Procedure time was similar between the two groups. In the pre-freezing group, the percentage of the left atrial posterior wall isolated was larger (47.6 ± 10.3 vs. 42.8 ± 15.7%, P = 0.006), and the postoperative reduction of diaphragmatic compound motor action potentials tended to occur less frequently (2.5 vs. 12.5%, P = 0.07), and the reduction of the cross-sectional LSPV area was smaller (17.5 ± 12.2 vs. 27.2 ± 19.8%, P = 0.03) than the conventional group. The AF-free rate of the two groups was similar between the two groups (P = 0.15). The pre-freezing technique was a simple method that can isolate a wider surface area during cryoballoon PV isolation. While the postoperative AF recurrence was comparable, the postoperative reduction in the cross-sectional PV area was less than that of the conventional method, which may reduce the risk of PV stenosis.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Congelamento , Estudos Transversais , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento
4.
J Cardiovasc Electrophysiol ; 33(9): 2100-2103, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35842800

RESUMO

INTRODUCTION: Catheter ablation for atrial fibrillation (AF) in patients with tachycardia-bradycardia syndrome (TBS) can be a major therapeutic option to replace permanent pacemaker implantation (PMI). However, the very long-term outcome of more than 15 years in these patients has not been elucidated. METHODS: From 2002 to 2008, 25 consecutive TBS patients (62 ± 7.9 years old, 68% male) with both AF and symptomatic sinus pauses (>3.0 s) were performed radiofrequency AF ablation. These patients were followed for 15 ± 2.7 years. RESULTS: The median longest sinus pause before the ablation procedure was 6.0 s (4.4-8.0). Following 1.6± 0.8 ablation procedures, 18 (72%) patients remained free from AF. Three (12%) patients died due to noncardiovascular causes, and seven (28%) patients underwent PMI due to symptomatic sinus pause after recurrent AF in five patients and progression of sinus node dysfunction in two patients. The median duration from the first AF ablation to PMI was 6.3 years (range: 9 days to 11.0 years). Five and two patients required PMI more than 5 and 10 years after the first ablation procedure, respectively. CONCLUSION: AF ablation prevented PMI in 72% of TBS patients for a 15-year follow-up. However, in consideration of the long duration of PMI, a continuous careful long-term follow-up was warranted.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Bradicardia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Síndrome do Nó Sinusal/terapia , Taquicardia/diagnóstico , Taquicardia/cirurgia , Resultado do Tratamento
5.
Circ J ; 86(2): 233-242, 2022 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-34219078

RESUMO

BACKGROUND: It is unclear whether there are differences in the clinical factors between atrial fibrillation (AF) recurrence and adverse clinical events (AEs), including stroke/transient ischemic attack (TIA), major bleeding, and death, after AF ablation.Methods and Results:We examined the data from a retrospective multicenter Japanese registry conducted at 24 cardiovascular centers between 2011 and 2017. Of the 3,451 patients (74.1% men; 63.3±10.3 years) who underwent AF ablation, 1,046 (30.3%) had AF recurrence and 224 (6.5%) suffered AEs (51 strokes/TIAs, 71 major bleeding events, and 36 deaths) over a median follow-up of 20.7 months. After multivariate adjustment, female sex, persistent and long-lasting persistent AF (vs. paroxysmal AF), and stepwise increased left atrial diameter (LAd) quartiles were significantly associated with post-ablation recurrences. A multivariate analysis revealed that an age ≥75 years (vs. <65 years), body weight <50 kg, diabetes, vascular disease, left ventricular (LV) ejection fraction <40% (vs. ≥50%), Lad ≥44 mm (vs. <36 mm), and creatinine clearance <50 mL/min were independently associated with AE incidences, but not with recurrences. CONCLUSIONS: This study disclosed different determinants of post-ablation recurrence and AEs. Female sex, persistent AF, and enlarged LAd were determinants of post-ablation recurrence, whereas an old age, comorbidities, and LV and renal dysfunction rather than post-ablation recurrence were AEs determinants. These findings will help determine ablation indications and post-ablation management.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Ataque Isquêmico Transitório , Acidente Vascular Cerebral , Idoso , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Hemorragia/etiologia , Humanos , Ataque Isquêmico Transitório/etiologia , Masculino , Recidiva , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
6.
Heart Vessels ; 37(1): 110-114, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34216250

RESUMO

The temporal changes in ambulatory monitoring findings after cryoballoon (CB) ablation of atrial fibrillation (AF) have not been well elucidated. This study aims to compare the details of ambulatory monitoring after CB and radiofrequency catheter (RFC) ablation for AF. Of 724 consecutive AF patients who underwent initial ablation using a CB or RFC, 508 (254 pairs) were selected using propensity score matching. Ambulatory monitoring was performed at 1, 3, 6, 12, 24 and 36 months after the procedure. After 1, 3 and 6 months, the number of total heart beats (THBs) was larger in the CB group than in the RFC group. It gradually decreased and became significantly similar by 12 months after ablation. THBs significantly increased 1, 3, 6 and 12 months after ablation in both the RFC and CB groups and became statistically similar by 24 months after ablation. The atrial premature contraction burden was higher in the RFC group than in the CB group at 3 months after ablation. THB and APC burden after AF ablation were significantly different between the RF and CB groups. THBs returned to statistically similarity by 2 years after ablation in both groups.


Assuntos
Fibrilação Atrial , Complexos Atriais Prematuros , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Complexos Atriais Prematuros/diagnóstico , Criocirurgia/efeitos adversos , Frequência Cardíaca , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
7.
Heart Vessels ; 37(2): 327-336, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34524497

RESUMO

The impact of catheter ablation for atrial fibrillation (AF) on cardiovascular events and mortality is controversial. We investigated the impact of sinus rhythm maintenance on major adverse cardiac and cerebrovascular events after AF ablation from a Japanese multicenter cohort of AF ablation. We investigated 3326 consecutive patients (25.8% female, mean age 63.3 ± 10.3 years) who underwent catheter ablation for AF from the atrial fibrillation registry to follow the long-term outcomes and use of anti coagulants after ablation (AF frontier ablation registry). The primary endpoint was a composite of stroke, transient ischemic attack, cardiovascular events, and all-cause death. During a mean follow-up of 24.0 months, 2339 (70.3%) patients were free from AF after catheter ablation, and the primary composite endpoint occurred in 144 (4.3%) patients. The AF nonrecurrence group had a significantly lower incidence of the primary endpoint (1.8 per 100 person-years) compared with the AF recurrence group (3.0 per 100 person-years, p = 0.003). The multivariate analysis revealed that freedom from AF (hazard ratio 0.61, 95% confidence interval 0.44-0.86, p = 0.005) was independently associated with the incidence of the composite event. In the multicenter cohort of AF ablation, sinus rhythm maintenance after catheter ablation was independently associated with lower rates of major adverse cardiac and cerebrovascular events.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Acidente Vascular Cerebral , Idoso , Fibrilação Atrial/complicações , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Sistema de Registros , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
8.
Heart Vessels ; 36(4): 549-560, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33236221

RESUMO

Whether ablation for atrial fibrillation (AF) is, in terms of clinical outcomes, beneficial for Japanese patients has not been clarified. Drawing data from 2 Japanese AF registries (AF Frontier Ablation Registry and SAKURA AF Registry), we compared the incidence of clinically relevant events (CREs), including stroke/transient ischemic attack (TIA), major bleeding, cardiovascular events, and death, between patients who underwent ablation (n = 3451) and those who did not (n = 2930). We also compared propensity-score matched patients (n = 1414 in each group). In propensity-scored patients who underwent ablation and those who did not, mean follow-up times were 27.2 and 35.8 months, respectively. Annualized rates for stroke/TIA (1.04 vs. 1.06%), major bleeding (1.44 vs. 1.20%), cardiovascular events (2.15 vs. 2.49%) were similar (P = 0.96, 0.39, and 0.35, respectively), but annualized death rates were lower in the ablation group than in the non-ablation group (0.75 vs.1.28%, P = 0.028). After multivariate adjustment, the risk of CREs was statistically equivalent between the ablation and non-ablation groups (hazard ratio [HR] 0.89, 95% confidence interval [CI] 0.71-1.11), but it was significantly low among patients who underwent ablation for paroxysmal AF (HR 0.68 [vs. persistent AF], 95% CI 0.49-0.94) and had a CHA2DS2-VASc score < 3 (HR 0.66 [vs. CHA2DS2-VASc score ≥ 3], 95% CI 0.43-0.98]). The 2-year risk reduction achieved by ablation may be small among Japanese patients, but AF ablation may benefit those with paroxysmal AF and a CHA2DS2-VASc score < 3.


Assuntos
Anticoagulantes/uso terapêutico , Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Pontuação de Propensão , Sistema de Registros , Medição de Risco/métodos , Acidente Vascular Cerebral/prevenção & controle , Idoso , Fibrilação Atrial/complicações , Feminino , Seguimentos , Humanos , Incidência , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Recidiva , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 31(8): 2222-2225, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32608049

RESUMO

We present a case of a 67-year-old female with a previous history of pulmonary vein isolation for paroxysmal atrial fibrillation who presented with supraventricular bigeminy with a constant coupling interval. The supraventricular bigeminy originated from the anterior mitral annulus with initial mapping suggestive of a focal mechanism. However detailed mapping using an ultrahigh resolution mapping system (with the manual shifting of the annotation window) revealed very low amplitude potentials connecting the previous sinus beat with continuous activation along the mitral annulus. Our observations were indicative of a re-entry mechanism underlying the supraventricular bigeminy.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Feminino , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Veias Pulmonares/cirurgia
10.
Int Heart J ; 61(6): 1165-1173, 2020 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-33191353

RESUMO

Direct oral anticoagulants (DOACs) are sometimes prescribed at off-label under-doses for patients who have undergone ablation for atrial fibrillation (AF). This practice may be an attempt to balance the risk of bleeding against that of stroke or AF recurrence.We examined outcomes of 1163 patients who continued use of a DOAC after ablation. The patients were enrolled in a large (3530 patients) multicenter registry in Japan. The study patients were classified as 749 (64.4%) appropriate standard-dose DOAC users, 216 (18.6%) off-label under-dose DOAC users, and 198 (17.0%) appropriate low-dose DOAC users.Age and CHA2DS2-VASc scores differed significantly between DOAC dosing regimens, with patients given an appropriate standard-dose being significantly younger (63.3 ± 9.4 versus 64.8 ± 9.5 versus 73.2 ± 6.8 years, P < 0.0001) and lower (2.1 ± 1.5 versus 2.4 ± 1.6 versus 3.4 ± 1.4, P < 0.0001) than those given an off-label under-dose or an appropriate low-dose. During the median 19.0-month follow-up period, the AF recurrence rate was similar between the appropriate standard-dose and off-label under-dose groups but relatively low in the appropriate low-dose group (42.5% versus 41.2% versus 35.4%, P = 0.08). Annualized rates of thromboembolic events, major bleeding, and death from any cause were 0.47%, 0.70%, and 0.23% in the off-label under-dose group, while those rates were 0.74%, 0.73%, and 0.65% in the appropriate standard-dose, and 1.58%, 2.12%, and 1.57% in the appropriate low-dose groups.In conclusion, the clinical adverse event rates for patients on an off-label under-dose DOAC regimen after ablation, predicated on careful patient evaluations, was not high as seen with that of patients on a standard DOAC dosing regimen.


Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter , Inibidores do Fator Xa/administração & dosagem , Hemorragia/induzido quimicamente , Acidente Vascular Cerebral/prevenção & controle , Tromboembolia/prevenção & controle , Idoso , Fibrilação Atrial/complicações , Feminino , Hemorragia/epidemiologia , Humanos , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Mortalidade , Uso Off-Label , Cuidados Pós-Operatórios , Recidiva , Sistema de Registros , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Tromboembolia/epidemiologia , Tromboembolia/etiologia
11.
J Cardiovasc Electrophysiol ; 30(11): 2310-2318, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31452290

RESUMO

BACKGROUND: The presence of heart failure (HF) has been associated with poorer outcomes in patients undergoing catheter ablation (CA) for atrial fibrillation (AF). However, the effectiveness of CA amongst the subset of patients with tachycardia-induced cardiomyopathy (TIC) remains poorly defined. METHODS AND RESULTS: In a retrospective analysis we compared outcomes of first-time CA for persistent AF in a cohort of patients with previously diagnosed TIC (n = 45; age 58 ± 8 years; 91% male) to those with structurally normal hearts (non-TIC; n = 440; age 55 ± 9 years; 95% male). TIC was defined as an impaired ventricular function (left ventricular ejection function [LVEF] <50%), which was reversed after the treatment of HF. We compared atrial arrhythmias (AAs) recurrence after the CA in the TIC and non-TIC cohorts. In the TIC group, LVEF improved from 35.8% ± 8.1% to 57.5% ± 8.3% after treatment of HF. During 3.3 ± 1.5 years follow-up, AAs-free survival after CA was significantly higher in the TIC group as compared with the non-TIC group (69% vs 42%; P = .001), despite a comparable CA strategy between the two groups. In multivariable analysis, absence of HF with TIC, longer AF duration, and complex fractionated atrial electrogram ablation were independent predictors of arrhythmia recurrence (OR, 1.02; 95% CI, 1.01-1.03; P < .01; OR, 0.40; 95% CI, 0.20-0.79; P < .01 and OR, 2.29; 95%CI; 1.27-4.11; P < .01, respectively). In addition, the outcome after the last procedure was superior in the TIC cohort (89% vs 72%; P = .03) with fewer CA procedures as compared with the non-TIC cohort (1.3 ± 0.5 vs 1.5 ± 0.7; P = .01). CONCLUSIONS: Persistent patients with AF with TIC have a more favorable outcome after the CA as compared with those without.


Assuntos
Fibrilação Atrial/cirurgia , Cardiomiopatias/etiologia , Ablação por Cateter , Potenciais de Ação , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Recidiva , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
12.
Europace ; 21(7): 1039-1047, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-30891597

RESUMO

AIMS: The circuit of pulmonary vein-gap re-entrant atrial tachycardia (PV-gap RAT) after atrial fibrillation ablation is sometimes difficult to identify by conventional mapping. We analysed the detailed circuit and electrophysiological features of PV-gap RATs using a novel high-resolution mapping system. METHODS AND RESULTS: This multicentre study investigated 27 (7%) PV-gap RATs in 26 patients among 378 atrial tachycardias (ATs) mapped with Rhythmia™ system in 281 patients. The tachycardia cycle length (TCL) was 258 ± 52 ms with P-wave duration of 116 ± 28 ms. Three types of PV-gap RAT circuits were identified: (A) two gaps in one pulmonary vein (PV) (unilateral circuit) (n = 17); (B) two gaps in the ipsilateral superior and inferior PVs (unilateral circuit) (n = 6); and (C) two gaps in one PV with a large circuit around contralateral PVs (bilateral circuit) (n = 4). Rhythmia™ mapping demonstrated two distinctive entrance and exit gaps of 7.6 ± 2.5 and 7.9 ± 4.1 mm in width, respectively, the local signals of which showed slow conduction (0.14 ± 0.18 and 0.11 ± 0.10m/s) with fragmentation (duration 86 ± 27 and 78 ± 23 ms) and low-voltage (0.17 ± 0.13 and 0.17 ± 0.21 mV). Twenty-two ATs were terminated (mechanical bump in one) and five were changed by the first radiofrequency application at the entrance or exit gap. Moreover, the conduction time inside the PVs (entrance-to-exit) was 138 ± 60 ms (54 ± 22% of TCL); in all cases, this resulted in demonstrating P-wave with an isoelectric line in all leads. CONCLUSION: This is the first report to demonstrate the detailed mechanisms of PV-gap re-entry that showed evident entrance and exit gaps using a high-resolution mapping system. The circuits were variable and Rhythmia™-guided ablation targeting the PV-gap can be curative.


Assuntos
Fibrilação Atrial/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/cirurgia , Veias Pulmonares/fisiopatologia , Veias Pulmonares/cirurgia , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/cirurgia , Ablação por Cateter/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
13.
Circ J ; 83(12): 2418-2427, 2019 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-31619591

RESUMO

BACKGROUND: The safety of discontinuing oral anticoagulant (OAC) after ablation for atrial fibrillation (AF) in Japanese patients has not been clarified.Methods and Results:A study based on the Atrial Fibrillation registry to Follow the long-teRm Outcomes and use of aNTIcoagulants aftER Ablation (AF Frontier Ablation Registry) was conducted. Data were collected from 3,451 consecutive patients (74.1% men; age, 63.3±10.3 years) who had undergone AF ablation at any of 24 cardiovascular centers in Japan between August 2011 and July 2017. During a 20.7-month follow-up period, OAC therapy was discontinued in 1,836 (53.2%) patients; 51 patients (1.5%) suffered a stroke/transient ischemic attack (TIA), 71 (2.1%) suffered major bleeding, and 36 (1.0%) died. Patients in whom OAC therapy was discontinued were significantly younger than those in whom OACs were continued, and their CHA2DS2-VASc scores were significantly lower. The incidences of stroke/TIA, major bleeding, and death were significantly lower among these patients. Upon multivariate adjustment, stroke events were independently associated with relatively high baseline CHA2DS2-VASc scores but not with OAC status. CONCLUSIONS: Although the incidences of stroke/TIA, major bleeding, and death were relatively low among patients for whom OAC therapy was discontinued, stroke/TIA occurrence was strongly associated with a high baseline stroke risk rather than with OAC status. Thus, discontinuation of OAC therapy requires careful consideration, especially in patients with a high baseline stroke risk.


Assuntos
Anticoagulantes/administração & dosagem , Fibrilação Atrial/terapia , Ablação por Cateter , Ataque Isquêmico Transitório/prevenção & controle , Acidente Vascular Cerebral/prevenção & controle , Administração Oral , Idoso , Anticoagulantes/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Ablação por Cateter/efeitos adversos , Ablação por Cateter/mortalidade , Esquema de Medicação , Feminino , Hemorragia/induzido quimicamente , Humanos , Incidência , Ataque Isquêmico Transitório/diagnóstico , Ataque Isquêmico Transitório/mortalidade , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Resultado do Tratamento
14.
Europace ; 20(6): 943-948, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29016768

RESUMO

Aims: Establishment of pulmonary vein isolation (PVI) during cryoballoon (CB) ablation is generally confirmed by use of an octapolar inner-lumen mapping catheter (Achieve®). The aim of this study is to evaluate the residual PV potential (PVP) using the conventional circular catheter after CB-PVI. Methods and results: A total of 105 consecutive patients (418 PVs) with paroxysmal AF who underwent the initial CB-PVI were prospectively included in this study. Of those, 305 (73%) PVs with real-time recordings of PVP elimination by Achieve® catheter during successful PVI were included. After isolation of all 4 PVs, PV antral remapping by conventional circular mapping catheter was performed. After CB-PVI, residual PVP was detected in 4.3% (13/305) of PVs (1.2% of left-superior PV, 2.5% of left-inferior PV, none of right-superior PV, and 20% of right-inferior PV). Almost 60% of residual PV potential was located around the bottom portion of the right-inferior PV. In PVs with residual potential, PV trunk was shorter (12.7 ± 5.7 mm vs. 18.7 ± 7.9, P = 0.001), minimal balloon temperature was higher (-46.6 ± 5.9 °C vs. -50.9 ± 8.2, P = 0.02), and balloon warming time was shorter (35.6 ± 17.8 s vs. 50.0 ± 22.8, P = 0.006) than those without. All residual potentials were eliminated by additional touch up ablation. After the initial ablation procedure, 1-year AF-free rate was 79.5%. Conclusion: PV remapping after CB-PVI revealed residual antral PVP in 4.3% of PVs and in 20% of RIPVs in particular. The Achieve® catheter sometimes fails to detect complete PV antral isolation.


Assuntos
Fibrilação Atrial , Cateteres Cardíacos , Criocirurgia , Técnicas Eletrofisiológicas Cardíacas , Cuidados Pós-Operatórios , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/instrumentação , Criocirurgia/métodos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Técnicas Eletrofisiológicas Cardíacas/métodos , Desenho de Equipamento , Feminino , Sistema de Condução Cardíaco/diagnóstico por imagem , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Cuidados Pós-Operatórios/instrumentação , Cuidados Pós-Operatórios/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Reprodutibilidade dos Testes , Resultado do Tratamento
15.
Heart Vessels ; 33(5): 529-536, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29147788

RESUMO

Cryoballoons (CBs) have proven to be effective for achieving pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). Dissociated PV activity (DPVA) after successful radiofrequency PVI is sometimes observed inside the PV and has been found to prove the achievement of electrical disconnection from the left atrium. However, little is known about the incidence or characteristics of DPVA after CB-PVI. The aim of this study was to compare the incidence and characteristics of DPVA in patients undergoing CB and radiofrequency (RF) ablation for AF. Two hundred and ninety-four propensity score-matched patients from 440 consecutive patients who underwent initial catheter ablation for paroxysmal AF were included in the present study (CB-PVI 147, RF-PVI 147). DPVA was more frequently observed after CB-PVI than after RF-PVI (32 vs. 19% of the PVs, P < 0.001), especially in the left superior PV (52 vs. 29%, P < 0.001) and left inferior PV (22 vs. 7%, P < 0.001). The AF-free rate after the initial ablation in the patients with and without DPVA was similar in both the CB (P = 0.23) and RF (P = 0.39) groups. During repeat ablation procedures for recurrent AF, PV reconnection was similarly observed in PVs with and without DPVA during the initial procedure, both in the CB (30 vs. 44%, P = 0.29) and RF (65 vs. 58%, P = 0.41) groups. DPVA was more frequently observed after CB-PVI than after RF-PVI. The presence of DPVA was not related to the ablation outcome or chronic PV reconnection following CB-PVI.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/fisiopatologia , Pontuação de Propensão , Veias Pulmonares/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Sistema de Condução Cardíaco/cirurgia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/cirurgia , Resultado do Tratamento
16.
Heart Vessels ; 33(10): 1238-1244, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29637262

RESUMO

Atrial fibrillation (AF) ablation requires transseptal puncture to access the left atrium. Recently, a radiofrequency (RF) needle was developed. The purpose of this study was to compare the incidence of MRI-confirmed acute cerebral embolism (ACE) during AF ablation procedures performed with RF needle versus mechanical needle transseptal puncture. This study consisted of 383 consecutive patients who underwent catheter ablation for AF that required transseptal puncture with mechanical or radiofrequency transseptal needles. Of those, 232 propensity score-matched patients (116 with each needle type) were included in the analysis. All patients had cerebral MRI performed 1 or 2 days after the procedure. Baseline characteristics were similar between the two groups. Total procedure time was significantly shorter in Group RF than Group non-RF (167 ± 50 vs. 181 ± 52 min, P = 0.01). ACE was detected by MRI in 59 (25%) patients. All patients with ACE were asymptomatic. Incidence of ACE was lower in Group RF than Group non-RF (19 vs. 32%, P = 0.02). B-type natriuretic peptide level was higher in the patients with ACE as compared to those without ACE (65.2 ± 68.7 vs. 44.7 ± 55.1 pg/ml, P = 0.02). In multivariable analysis, the use of RF needle and BNP level was related to the incidence of ACE (OR = 0.499, 95% CI 0.270-0.922, P = 0.03 and OR = 1.005, 95% CI 1.000-1.010, P = 0.03). Use of RF needle for transseptal puncture was associated with lower total procedure time and risk of ACE during catheter ablation of AF.


Assuntos
Fibrilação Atrial/cirurgia , Septo Interatrial/cirurgia , Ablação por Cateter/instrumentação , Complicações Intraoperatórias/epidemiologia , Agulhas , Punções/instrumentação , Tromboembolia/epidemiologia , Fibrilação Atrial/diagnóstico , Septo Interatrial/diagnóstico por imagem , Ecocardiografia Transesofagiana , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Incidência , Complicações Intraoperatórias/prevenção & controle , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Estudos Retrospectivos , Tromboembolia/diagnóstico , Tromboembolia/etiologia , Tomografia Computadorizada por Raios X
17.
Heart Vessels ; 33(7): 770-776, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29357093

RESUMO

Atrial fibrillation (AF), especially asymptomatic cases, is often detected by medical checkups. We investigated the outcome of AF ablation in cases detected by medical checkups. We reviewed the data of 735 patients with AF (56 ± 10 years, paroxysmal: 441 patients) who underwent initial catheter ablation. All patients were divided into two groups based on their AF being diagnosed either by a medical checkup (group M) or not (group NM). AF was diagnosed by medical checkups in 263 (36%) patients. In Group M, the age was younger, time from the diagnosis to ablation shorter, left atrium dimension larger, and left ventricular ejection fraction lower than in Group NM. Male gender, persistent AF, and asymptomatic AF were more frequently seen in Group M than in Group NM. A mean of 13 ± 11 months after the initial ablation procedure, AF recurrence was more frequently observed in group M compared to group NM (P = 0.018). While the AF recurrence rate was similar in both groups in persistent AF patients (P = 0.87), it was more frequently observed in Group M than in Group NM in paroxysmal AF patients (P = 0.005). AF diagnosed by medical checkups was often associated with a worse outcome of catheter ablation, especially in paroxysmal AF patients.


Assuntos
Fibrilação Atrial/diagnóstico , Ablação por Cateter , Taquicardia Paroxística/diagnóstico , Angiografia , Fibrilação Atrial/cirurgia , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquicardia Paroxística/cirurgia , Resultado do Tratamento
18.
Heart Vessels ; 32(4): 501-505, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28054100

RESUMO

We herein present a case (72 years, male) with total absence of pulmonary veins (PVs) potentials at the beginning of the first procedure for paroxysmal atrial fibrillation (AF), demonstrating dormant conduction between the left atrium and all PVs revealed by adenosine triphosphate provocation with relation to the incidence of AF. He was free from atrial arrhythmias during 1 year follow-up after complete PV isolation with the elimination of multiple transient dormant conductions by circular mapping catheter guide ablation.


Assuntos
Trifosfato de Adenosina/administração & dosagem , Fibrilação Atrial/cirurgia , Ablação por Cateter , Veias Pulmonares/cirurgia , Idoso , Humanos , Masculino , Veias Pulmonares/fisiopatologia , Resultado do Tratamento
19.
J Cardiovasc Electrophysiol ; 27(1): 88-94, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26519347

RESUMO

BACKGROUND: Optimal procedure endpoints of catheter ablation for ventricular tachycardia (VT) are not defined and multiple repeat procedures are sometimes required. However, there are few studies to compare the details of repeat procedures to the initial procedure. The aim of this study is to compare the characteristics of clinical and induced VT throughout multiple procedures and clarify their relations. METHODS AND RESULTS: Of 425 consecutive patients with structural heart disease who underwent catheter VT ablation, second, third and fourth procedures were performed in 101, 23, and 5 patients, respectively. Of 227 VTs that were induced during the second procedure, 68 (30%) VTs had previously been induced at the first procedure. In multivariable analysis, identification of an exit/isthmus site (HR = 0.29, P = 0.047), early termination of VT during radiofrequency application (HR 0.11, P = 0.037) and elimination of target VT at the end of first procedure (HR = 0.43, P = 0.036) were independently associated with noninducibility of the same VT at the second procedure. Over the course of multiple procedures the mean VT cycle length gradually lengthened (381 ± 107, 413 ± 111, 460 ± 124, 507 ± 99 milliseconds in first, second, third, and fourth procedure, respectively, P < 0.001) and more induced VTs became mappable (32%, 40%, 62%, and 70% in first, second, third, and fourth procedure, respectively, P < 0.001). CONCLUSIONS: Identification and ablation of VT exit/isthmus, early termination of VT during radiofrequency application and elimination of targeted VT are associated with absence of that VT during a repeat procedure, and recurrences are then mostly due to new VTs or other VTs that were not induced at the first procedure.


Assuntos
Ablação por Cateter , Frequência Cardíaca , Ventrículos do Coração/cirurgia , Taquicardia Ventricular/cirurgia , Potenciais de Ação , Idoso , Estimulação Cardíaca Artificial , Ablação por Cateter/efeitos adversos , Distribuição de Qui-Quadrado , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Reoperação , Fatores de Risco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
20.
Heart Vessels ; 31(2): 261-4, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25213428

RESUMO

A 57-year-old male with persistent atrial fibrillation (AF) was referred for catheter ablation. Multidetector computed tomography (MDCT) revealed that a membrane divided the left atrium into two chambers, thus indicating the presence of cor triatriatum sinister. A 3D image reconstructed by MDCT showed that the accessory atrium received the left common and the right side PVs, as if it were a total common trunk, and this then flowed into the main atrium. After isolation of the pulmonary vein and posterior wall from the left atrium, AF could not be induced by any programmed pacing. The patient has remained free from AF during the 1 year of follow-up.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Coração Triatriado/complicações , Veias Pulmonares/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Estimulação Cardíaca Artificial , Coração Triatriado/diagnóstico , Técnicas Eletrofisiológicas Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Flebografia , Veias Pulmonares/anormalidades , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA