Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
Medicina (Kaunas) ; 57(2)2021 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-33503841

RESUMO

The subject was a 66-year-old woman, suffering from the chest pain evoked by physical activity. Transthoracic echocardiography (TTE) revealed an abnormal structure, 41 × 29 mm. In MSCT, a hypodensic mobile tissue lesion that was infiltrating the whole thickness of left ventricle was confirmed. PET excluded the existence of other remote lesions. After surgical tumor removal, histopathological differential diagnosis revealed melanoma, myoepithelial cancer, and MPNST "high-grade" sarcoma. A control TTE detected a tumor that was 14 × 10 mm. After immunohistochemical results, immunotherapy with pembrolizumab was used, which resulted in complete tumor resolution. Presently, surgical resection and neoadjuvant targeted immunochemotherapy remain the treatment of choice for clinical stage III/IV melanoma.


Assuntos
Melanoma , Neoplasias Cutâneas , Idoso , Ecocardiografia , Feminino , Ventrículos do Coração , Humanos , Melanoma/diagnóstico , Melanoma/tratamento farmacológico , Neoplasias Cutâneas/diagnóstico , Neoplasias Cutâneas/tratamento farmacológico
2.
Pol J Radiol ; 83: e334-e339, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30627256

RESUMO

PURPOSE: Total anomalous pulmonary vein drainage (TAPVD) is a congenital cardiac defect in which there is no connection between pulmonary veins and the left atrium. Pulmonary veins form a confluence independent of the left atrium and drain to a systemic vein. TAPVD types are: supracardiac, cardiac, infracardiac, and mixed. TAPVD accounts for approximately 1.5-2.2% of all congenital heart diseases. This anomaly is usually diagnosed in the neonatal period, and it coexists with atrial septal defect. Adult cases of TAPVD are rarely reported. CASE REPORT: We report a rare case of a 60-year-old woman with incidentally found, uncorrected TAPVD in ECG-gated multidetector computed tomography. In previous echocardiographic examinations partial anomalous pulmonary venous return and atrial septal defect were diagnosed. CONCLUSIONS: ECG-gated multidetector computed tomography is a valuable diagnostic method for adults with congenital heart disease. It enables evaluation of coronary arteries and simultaneously provides detailed anatomy of great vessels.

3.
Europace ; 19(6): 1022-1030, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-27358071

RESUMO

AIMS: The presence of intracardiac lead vegetations (ILV) is one of the important criteria for diagnosis of lead-related infective endocarditis (LRIE). The objective of the present study was to evaluate risk factors of ILV and their impact on vegetation size. METHODS AND RESULTS: Clinical data of 500 patients with LRIE undergoing transvenous lead extraction in 2006-15 were retrospectively analysed. The study population consisted of 352 patients with the presence of vegetations (giant, >3 cm; large, 2.0-2.9 cm; moderate-sized, 1.0-1.9 cm; and small, <1 cm) and 148 patients without ILV. We identified risk factors for vegetation occurrence and ILV size. Intracardiac lead vegetations were found more frequently in younger patients (P < 0.05), slightly more often in women (P = 0.084), and less commonly in patients with atrial fibrillation (P < 0.05). Intracardiac lead vegetation occurred significantly more frequently in patients with intracardiac lead abrasion (OR 2.373; 95% CI [1.497-3.765]; P < 0.001) and much less frequently in the concomitant presence of pocket infection (PI) (OR 0.127; 95% CI [0.074-0.218]; P < 0.00). Large vegetations were significantly more common in patients with renal failure (RF) (P < 0.001), heart failure (P < 0.001), implantable cardioverter defibrillator (P < 0.05), and loops of the leads (P < 0.001). CONCLUSION: Intracardiac lead abrasion is one of the most common factors influencing the occurrence of ILV. Metabolic disorders in patients with RF, heart failure, defibrillation leads, and loops of the leads were found to contribute to the formation of large vegetations. In LRIE patients, ILVs were less frequently detected in the presence of concomitant PI, indicating a different mechanism of LRIE development in patients with and without vegetations.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Endocardite/etiologia , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/etiologia , Fatores Etários , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Distribuição de Qui-Quadrado , Comorbidade , Remoção de Dispositivo , Intervalo Livre de Doença , Ecocardiografia , Endocardite/diagnóstico , Endocardite/cirurgia , Humanos , Estimativa de Kaplan-Meier , Análise Multivariada , Razão de Chances , Desenho de Prótese , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/cirurgia , Estudos Retrospectivos , Fatores de Risco , Fatores Sexuais , Fatores de Tempo
4.
Artigo em Inglês | MEDLINE | ID: mdl-28213932

RESUMO

BACKGROUND: Electrocardiography (ECG) is still one of the first tests performed at admission, mostly in patients (pts) with chest pain or dyspnea. The aim of this study was to assess the correlation between electrocardiographic abnormalities and cardiac biomarkers as well as echocardiographic parameter in patients with acute pulmonary embolism. METHODS: We performed a retrospective analysis of 614 pts. (F/M 334/280; mean age of 67.9 ± 16.6 years) with confirmed acute pulmonary embolism (APE) who were enrolled to the ZATPOL-2 Registry between 2012 and 2014. RESULTS: Elevated cardiac biomarkers were observed in 358 pts (74.4%). In this group the presence of atrial fibrillation (p = .008), right axis deviation (p = .004), S1 Q3 T3 sign (p < .001), RBBB (p = .006), ST segment depression in leads V4 -V6 (p < .001), ST segment depression in lead I (p = .01), negative T waves in leads V1 -V3 (p < .001), negative T waves in leads V4 -V6 (p = .005), negative T waves in leads II, III and aVF (p = .005), ST segment elevation in lead aVR (p = .002), ST segment elevation in lead III (p = .0038) was significantly more frequent in comparison to subjects with normal serum level of cardiac biomarkers. In multivariate regression analysis, clinical predictors of "abnormal electrocardiogram" were as follows: increased heart rate (OR 1.09, 95% CI 1.02-1.17, p = .012), elevated troponin concentration (OR 3.33, 95% CI 1.94-5.72, p = .000), and right ventricular overload (OR 2.30, 95% CI 1.17-4.53, p = .016). CONCLUSIONS: Electrocardiographic signs of right ventricular strain are strongly related to elevated cardiac biomarkers and echocardiographic signs of right ventricular overload. ECG may be used in preliminary risk stratification of patient with intermediate- or high-risk forms of APE.


Assuntos
Eletrocardiografia/métodos , Eletrocardiografia/estatística & dados numéricos , Embolia Pulmonar/sangue , Embolia Pulmonar/diagnóstico , Sistema de Registros , Doença Aguda , Idoso , Biomarcadores/sangue , Feminino , Humanos , Masculino , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Troponina/sangue
5.
Acta Cardiol ; 69(3): 338-40, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25029887

RESUMO

We present a case of diaphragmatic fibrillation (with a frequency of 600/min) in a patient at the early post-operative stages. In view of the decreased oxygen saturation and confusion, the patient was sedated and mechanically ventilated. His declining physical condition was partially associated with diaphragmatic fibrillation superimposed on heart failure and lung disease. The transthoracic echocardiography was technically difficult. Consequently, transoesophageal echocardiography was undertaken. This is the first case report presenting diaphragmatic fibrillation as an incidental finding on transoesophageal echocardiography.


Assuntos
Diafragma/fisiopatologia , Insuficiência Cardíaca/complicações , Neoplasias Pulmonares , Isquemia Miocárdica/complicações , Complicações Pós-Operatórias , Progressão da Doença , Ecocardiografia Transesofagiana/métodos , Evolução Fatal , Humanos , Achados Incidentais , Neoplasias Pulmonares/complicações , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/cirurgia , Masculino , Pessoa de Meia-Idade , Pneumonectomia/efeitos adversos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Tomografia Computadorizada por Raios X
6.
J Clin Med ; 12(23)2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38068550

RESUMO

BACKGROUND: Patients with infectious complications related to the presence of cardiac implantable electronic devices (CIED) constitute a heterogeneous group, ranging from local pocket infection (PI) to lead-related infectious endocarditis (LRIE) infection spreading along the leads to the endocardium. The detection of isolated LRIE and the assessment of the spread of infection in a patient with PI is often difficult and requires complex imaging and microbiological tests. The aim of the current study is to evaluate the usefulness of new simple hematological parameters in detecting infectious complications in patients with CIED, differentiating vegetation and vegetation-like masses, and assessing the extent of infections in patients with PI. METHODS: A retrospective analysis of clinical data of 2909 patients (36.37% with CIED-related infections), undergoing transvenous lead extraction (TLE) procedures in three high-volume centres in the years 2006-2020, was conducted. Receiver operating characteristic (ROC) curve analysis was used to assess the sensitivity and specificity of neutrophil-to-lymphocyte ratio (NLR), neutrophil-to-platelet ratio (NPR), and lymphocyte-to-platelet ratio (LPR) in the diagnosis of CIED infections, evaluate the spread of the infectious process in patients with PI and differentiate additional structures related to the presence of lead. RESULTS: The values of NLR and NPR were significantly higher in infectious patients than non-infectious controls (3.07 vs. 2.59; p < 0.001, and 0.02 vs. 0.01; p = 0.008) and the area under the ROC curve (AUC) was 0.59; p < 0.001 and 0.56; p < 0.001, respectively. The high specificity of the new markers in detecting the infectious process was demonstrated: 72.82% for NLR (optimal cut-off value: 3.06) and 79.47% for NPR (optimal cut off value: 0.02). The values of NLR and NPR were significantly higher in patients with vegetations than in non-infectious patients with the presence of additional lead-related masses (3.37 vs. 2.61; p < 0.001 and 0.03 vs. 0.02; p = 0.008). The AUC of NLR and NPR for the prediction of vegetations was 0.65; p < 0.001 and 0.60; p < 0.001 with the highest specificity of NPR (82.78%) and an optimal cut-off value of 0.03. NLR and NPR were higher in patients with LRIE compared to isolated PI (4.11 vs. 2.56; p < 0.001 and 0.03 vs. 0.02; p < 0.001) and the ROC curve analysis for coexistence LRIE with PI showed the AUC for NLR: 0.57; p < 0.001 and AUC for NPR: 0.55; p = 0.001. High specificity in the detection of coexistence between PI and LRIE was demonstrated for NLR (87.33%), with an optimal cut-off value of 3.13. CONCLUSIONS: Novel hematological markers (NLR and NPR) are characterized by high specificity in the initial diagnosis of CIED infections, with optimal cut-off values of 3.06 and 0.02. NLR is also useful in the assessment of the spread of infection in patients with PI, with a calculated optimal cut-off value of 3.13. NPR may be helpful in the differentiation of vegetation and vegetation-like masses with an optimal cut-off value of 0.03.

7.
Med Sci Monit ; 18(3): CS26-30, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22367133

RESUMO

BACKGROUND: Takotsubo syndrome (TTS) is a transient cardiomyopathy of unknown origin, clinically manifesting as acute coronary syndrome (ACS). This syndrome mainly occurs in postmenopausal women and has a temporary relationship with emotional or physical stress. CASE REPORT: TTS occurred in 46-year-old female patient on the first day after renal transplantation. The predominant symptoms were connected with ACS, performed with low grade troponin elevation and characteristic shape of left ventricle depicted in echocardiography. Taking into consideration the risk of the development of contrast-induced nephropathy, coronary angiography (CA) was delayed; myocardial perfusion scintigraphy and iodine-123 metaiodobenzylguanidine (¹²³I-mIBG) myocardial uptake were performed to confirm the clinical suspicion. Myocardial perfusion scintigraphy (MPS) performed in rest condition showed normal perfusion but myocardial uptake of ¹²³I-mIBG was impaired. Within 6 months after surgery, full recovery of all biochemical and functional parameters of the left ventricle were observed. At that time CA was done, depicting normal coronary arteries. CONCLUSIONS: TTS could be diagnosed by the use of non-nephrotoxic tests - ¹²³I-mIBG myocardial scintigraphy, MPS and echocardiography.


Assuntos
Transplante de Rim/efeitos adversos , Cardiomiopatia de Takotsubo/etiologia , 3-Iodobenzilguanidina , Angiografia Coronária , Feminino , Humanos , Radioisótopos do Iodo , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio , Cardiomiopatia de Takotsubo/diagnóstico
8.
Artigo em Inglês | MEDLINE | ID: mdl-35627340

RESUMO

Background: Transvenous lead extraction (TLE) in patients with implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy (CRT) devices is considered as more risky. The aim of this study was to assess the safety and effectiveness of TLE in patients with infected CRT systems. Methods: Data of 3468 patients undergoing TLE in a single high-volume center in years 2006−2021 were analyzed. The clinical and procedural parameters as well as the efficacy and safety of TLE were compared between patients with infected CRT and pacemakers (PM) and ICD systems. Results: Infectious indications for TLE occurred in 1138 patients, including 150 infected CRT (112 CRT-D and 38 CRT-P). The general health condition of CRT patients was worse with higher Charlson's comorbidity index. The number of extracted leads was higher in the CRT group, but implant duration was significantly longer in the PM than in the ICD and CRT groups (98.93 vs. 55.26 vs. 55.43 months p < 0.01). The procedure was longer in duration, more difficult, and more complex in patients with pacemakers than in those in the CRT group. The occurrence of major complications and clinical and procedural success as well as procedure-related death did not show any relationship to the type of CIED device. Mortality at more than one-year follow-up after TLE was significantly higher among patients with CRT devices (22.7% vs. 8.7%) than among those in the PM group. Conclusion: Despite the greater burden of lead and comorbidities, the complexity and efficiency of removing infected CRT systems is no more dangerous than removing other infected systems. The duration of the implant seems to play a dominant role.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Comorbidade , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/métodos , Humanos , Chumbo
9.
Artigo em Inglês | MEDLINE | ID: mdl-36231579

RESUMO

BACKGROUND: Damage to the tricuspid valve (TVD) is now considered either a major or minor complication of the transvenous lead extraction procedure (TLE). As yet, the risk factors and long-term survival after TLE in patients with TVD have not been analyzed in detail. METHODS: This post hoc analysis used clinical data of 2631 patients (mean age 66.86 years, 39.64% females) who underwent TLE procedures performed in three high-volume centers. The risk factors and long-term survival of patients with worsening tricuspid valve (TV) function after TLE were analyzed. RESULTS: In most procedures (90.31%), TLE had no negative influence on TV function, but in 9.69% of patients, a worsening of tricuspid regurgitation (TR) to varying degrees was noted, including significant dysfunction in 2.54% of patients. Risk factors of TLE relating to severe TVD were: TLE of pacing leads (5.264; p = 0.029), dwell time of the oldest extracted lead (OR = 1.076; p = 0.032), strong connective scar tissue connecting a lead with tricuspid apparatus (OR = 5.720; p < 0.001), and strong connective scar tissue connecting a lead with the right ventricle wall (OR = 8.312; p < 0.001). Long-term survival (1650 ± 1201 [1-5519] days) of patients with severe TR was comparable to patients without tricuspid damage related to TLE. CONCLUSIONS: Severe tricuspid valve damage related to TLE is relatively rare (2.5%). The main risk factors for the worsening of TV function are associated with a longer lead dwell time (more often the pacing lead), causing stronger connective tissue scars connecting the lead to the tricuspid apparatus and right ventricle. TVD is unlikely to affect long-term survival after TLE.


Assuntos
Marca-Passo Artificial , Insuficiência da Valva Tricúspide , Idoso , Cicatriz/complicações , Feminino , Humanos , Chumbo , Masculino , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/etiologia
10.
J Clin Med ; 10(15)2021 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-34362015

RESUMO

Pulmonary arterial hypertension (PAH) is a rare, progressive disease in which there is a persistent, abnormal increase in pulmonary artery pressure. Symptoms of pulmonary hypertension are nonspecific and mainly associated with progressive right ventricular failure. The diagnosis of PAH is a multistep process and often requires the skillful use of several tests. The gold standard for the diagnosis of PAH is hemodynamic testing. Echocardiography currently plays an important role in the diagnostic algorithm of PAH as it is minimally invasive and readily available. Moreover, many echocardiographic parameters are closely related to pulmonary hemodynamics. It allows assessment of the right heart's structure and function, estimation of the pressure in the right ventricle, right atrium, and pulmonary trunk, and exclusion of other causes of elevated pulmonary bed pressure. Echocardiographic techniques are constantly evolving, and recently, measurements made using new techniques, especially 3D visualization, have become increasingly important. In echocardiographic assessment, it is crucial to know current guidelines and new reports that organize the methodology and allow standardization of the examination. This review aims to discuss the different echocardiographic techniques used to evaluate patients with PAH.

11.
J Clin Med ; 11(1)2021 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-35011829

RESUMO

BACKGROUND: Lead-related tricuspid valve dysfunction (LDTVD) has not been studied in a large population and its management remains controversial. METHODS: An analysis of the clinical data of 2678 patients undergoing transvenous lead extraction (TLE) in years 2008-2021 was conducted, with a separate group of 119 patients with LDTVD. Potential risk factors for LDTVD, improvement in valve function, and long-term prognosis after TLE were assessed. RESULTS: LDTVD was diagnosed in 4.44% of patients referred for lead extraction due to different reasons. The most common mechanism of LDTVD was propping upward or clamping down the leaflet by the lead (85.71%). The probability of LDTVD was higher in female sex, patients with valvular heart disease, atrial fibrillation, heart failure, large right ventricle and high pulmonary artery systolic pressure, the presence of only pacing lead, and in case of collision of the lead with tricuspid valve and adhesion of the lead to the heart structures. The prognosis of patients with LDTVD was worse, however, patients with improved valve function after TLE showed a significantly better long-term survival. CONCLUSIONS: Lead dependent tricuspid valve dysfunction is a potentially serious condition that requires thorough diagnostics and thoughtful management. The risk factors for LDTVD are primarily related to the course of the lead and its adhesion to the heart structures. Improvement of tricuspid valve function after TLE is observed in 35.29% of patients Patients with LDTVD have a worse long-term survival, but the improvement in valve function following TLE contributes to a significant reduction in mortality.

12.
Eur Radiol ; 20(7): 1615-20, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20069425

RESUMO

OBJECTIVES: Right ventricular dysfunction (RVD) may occur in the course of acute pulmonary embolism (PE). Patients with RVD need more intensive treatment, and the prognosis is more severe. The aim of this study was to evaluate the usefulness of the measurement of the coronary sinus in the assessment of RVD in patients with acute PE and to compare it with other indicators of RVD. METHODS: Retrospective assessment of 55 CT pulmonary angiography examinations with signs of acute PE was performed. Pulmonary artery systolic pressure (PASP) was echocardiographically assessed in all patients, and RVD was defined as PASP values greater than 30 mmHg. CT measurements included the size of the heart ventricles, mediastinal vessels and the width of the coronary sinus. RESULTS: Median width of the coronary sinus was 16 mm (range 12-24 mm) in patients with increased PASP and 10 mm (range 7-22 mm) in patients with normal PASP (p = 0.001). Best cut-off value was assessed to be 12.5 mm, with sensitivity 94% and specificity 75%. It was characterised by the largest area under ROC curve (0.82) among analysed parameters. CONCLUSION: Width of the coronary sinus seems to be a promising parameter for identification of RVD in patients with acute PE. A prospective study should be undertaken to further assess its clinical and prognostic applicability.


Assuntos
Seio Coronário/diagnóstico por imagem , Seio Coronário/fisiopatologia , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Disfunção Ventricular Direita/complicações , Disfunção Ventricular Direita/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X , Adulto Jovem
13.
Europace ; 12(3): 445-6, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20093254

RESUMO

We discuss a case of transvenous removal of endocardial leads in a patient with initial contraindication for such a procedure due to the size of the vegetation in his right atrium. Simultaneously, the patient's progressive general poor condition during the course of infective endocarditis prognosed that cardiosurgical intervention with the use of cardiopulmonary bypass would be unsuccessful. Using an innovative solution, that is placing the Dotter's basket in the right ventricular outlet as a protection against massive pulmonary embolism, the leads were removed. An asymptomatic pulmonary embolism caused by defragmented vegetation was revealed after the procedure.


Assuntos
Estimulação Cardíaca Artificial/efeitos adversos , Remoção de Dispositivo/métodos , Endocardite/cirurgia , Marca-Passo Artificial/efeitos adversos , Marca-Passo Artificial/microbiologia , Infecções Relacionadas à Prótese/cirurgia , Idoso , Endocardite/diagnóstico por imagem , Humanos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Embolia Pulmonar/prevenção & controle , Ultrassonografia
14.
J Clin Med ; 9(6)2020 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-32599687

RESUMO

Idiopathic pulmonary arterial hypertension (IPAH) is a rare but severe disease with the elevated blood pressure in the pulmonary arteries without a known trigger of vascular remodelling. It leads to the right heart failure with reduced survival. Changes in the immunological landscape of the lungs and the periphery are common in IPAH patients, suggesting an immune system dysfunction. A cohort of 25 IPAH patients was enrolled in our study to investigate a link between the patient's clinical status, immune parameters of the blood, and the Epstein-Barr virus (EBV) infection. We found significant alterations of the patients' peripheral blood parameters. Therein, T lymphocytes and NK cell counts were decreased in the IPAH patients' blood, while the proportion of regulatory T cells was increased. Additionally, levels of proinflammatory cytokines interleukin-6 (IL-6), IL-2, and interferon-gamma (IFN-γ) were elevated. We identified a weak correlation between EBV loads and IPAH patients' clinical state (r = 0.54) and between EBV loads and overexpression of PD-1 on helper T cells (r = 0.56). We speculate that a significant dysregulation of the immune system homeostasis observed in IPAH patients may contribute to increased susceptibility of those patients to EBV infection, yet further longitudinal studies are required to characterize this relation in detail.

15.
Int J Cardiovasc Imaging ; 36(3): 423-430, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31734932

RESUMO

Detection of residual fibrotic tissue, called ghosts, after lead extraction is a new phenomenon in cardiology. This paper aims at describing the phenomenon of ghosts and determining their characteristic features. The study group consisted of 580 consecutive patients who underwent transvenous lead extraction (TLE) due to local infection, endocarditis and a superfluous lead. Each patient was clinically examined with the application of transthoracic echocardiography and transesophageal echocardiography directly before and after TLE. In the study population ghosts were detected in 110 patients (19%), and in 470 cases (81%) fibrotic tissue residuals were not found. Ghosts were most often located along the originally implanted lead's route. Longer ghosts were found after the removal of cardiac resynchronization therapy (CRT) and dual chamber pacing (DDD) devices. The local infection and infective endocarditis are associated with a larger number of ghosts revealed after the removal procedure (p = 0.006). The type of the implanted device: CRT/ICD/double chamber pacemaker/single chamber pacemaker, similar to the number of leads, did not impact on the number of the detected ghosts. The relationship between abrasions of the leads and the presence of ghosts proved significant, however (p = 0.043). TLE is associated with the presence of fibrotic tissue residuals in approx. 19% of patients. Indications for lead extraction due to local infection and endocarditis yielded significantly more cases of ghosts than in the entire patient population. The presence of abrasions is a good predictor for the presence of ghosts on the leads.


Assuntos
Remoção de Dispositivo , Ecocardiografia Transesofagiana , Endocardite/cirurgia , Coração/diagnóstico por imagem , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Endocardite/diagnóstico por imagem , Desenho de Equipamento , Feminino , Fibrose , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Infecções Relacionadas à Prótese/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Adulto Jovem
16.
J Clin Med ; 9(5)2020 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-32397115

RESUMO

BACKGROUND: Transesophageal echocardiography (TEE) is a valuable tool for monitoring the patient during transvenous lead extraction (TLE), but the direct impact of TEE on the effectiveness and safety of TLE has not yet been documented. METHODS: The effectiveness of TLE and short-term survival were compared between two groups of patients: 2106 patients in whom TEE was performed before and after TLE and 1079 individuals in whom continuous TEE monitoring was used. The procedure-related risk of major complications was assessed using a predictive SAFeTY TLE score. RESULTS: The patients monitored by TEE were characterized by older age, more comorbidities and higher SAFeTY TLE scores (6.143 ± 4.395 vs. 5.593 ± 4.127; p = 0.004). Complete procedural success was significantly higher in the TEE-guided group (97.683% vs. 95.442%, p < 0.01). The rate of serious complications in the TEE-guided group was lower than the predictive SAFeTY TLE score-a reduction of 28.75% (p < 0.05). Periprocedural mortality in the TEE-guided and non-TEE-guided groups was zero vs. six deaths (p = 0.186). Short-term survival was comparable between the groups. CONCLUSIONS: Transesophageal echocardiography as a monitoring tool during transvenous lead extraction provides valuable results-higher rates of complete procedural success and a reduced risk of the most severe complications, thus preventing periprocedural deaths.

17.
Circ J ; 73(11): 2163-5, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19218740

RESUMO

Noncompaction of the ventricular myocardium is a recently recognized genetic cardiomyopathy. The left ventricle is the most affected site, but right ventricular involvement has been reported in some cases. Diagnosis is made with 2-dimensional echocardiography or cardiac magnetic resonance imaging. The major clinical manifestations are heart failure, arrhythmias and embolic events. A 20-year old man had left and right ventricular noncompaction complicated by severe pulmonary hypertension, which is one of the first cases of biventricular noncompaction associated with severe pulmonary hypertension. Pulmonary hypertension may be a consequence of increased pulmonary venous pressures caused by systolic and diastolic heart dysfunction secondary to noncompaction.


Assuntos
Hipertensão Pulmonar/etiologia , Miocárdio Ventricular não Compactado Isolado/complicações , Disfunção Ventricular Esquerda/etiologia , Diástole , Ecocardiografia Doppler em Cores , Humanos , Hipertensão Pulmonar/fisiopatologia , Miocárdio Ventricular não Compactado Isolado/diagnóstico , Miocárdio Ventricular não Compactado Isolado/fisiopatologia , Imageamento por Ressonância Magnética , Masculino , Pressão Propulsora Pulmonar , Sístole , Disfunção Ventricular Esquerda/fisiopatologia , Adulto Jovem
18.
Kardiol Pol ; 67(11): 1252-5, 2009 Nov.
Artigo em Polonês | MEDLINE | ID: mdl-20024853

RESUMO

A 77-year-old female in severe emotional distress was admitted to Coronary Care Unit with typical features of acute coronary syndrome, namely severe chest pain, high cardiac necrosis markers and ST-elevation in ECG. Due to the lack of significant changes in coronary arteries in coronary angiography the contractile function of the heart muscle was assessed in echocardiographic examination. That allowed to diagnose tako-tsubo cardiomyopathy. This condition is commonly triggered by stress. This case report puts emphasis on anamnesis, which is often underestimated when diagnosing tako-tsubo syndrome.


Assuntos
Cardiomiopatia de Takotsubo/diagnóstico , Síndrome Coronariana Aguda/diagnóstico , Idoso , Angiografia Coronária , Diagnóstico Diferencial , Ecocardiografia , Eletrocardiografia , Feminino , Humanos , Anamnese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA