Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Arq Bras Cardiol ; 120(10): e20220768, 2023 10.
Artigo em Inglês, Português | MEDLINE | ID: mdl-37909602

RESUMO

Heart Failure is a significant public health problem leading to a high burden of physical and psychological symptoms despite optimized therapy. To evaluate primarily the impact of a Stress Reduction, Meditation, and Mindfulness Program on stress reduction of patients with Heart Failure. A randomized and controlled clinical trial assessed the effect of a stress reduction program compared to conventional multidisciplinary care in two specialized centers in Brazil. The data collection period took place between April and October 2019. Thirty-eight patients were included and allocated to the intervention or control groups. The intervention took place over 8 weeks. The protocol assessed the scales of perceived stress, depression, quality of life, anxiety, mindfulness, quality of sleep, a 6-minute walk test, and biomarkers analyzed by a blinded team, considering a p-value <0.05 statistically significant. The intervention resulted in a significant reduction in perceived stress from 22.8 ± 4.3 to 14.3 ± 3.8 points in the perceived stress scale-14 items in the intervention group vs. 23.9 ± 4.3 to 25.8 ± 5.4 in the control group (p-value<0.001). A significant improvement in quality of life (p-value=0.013), mindfulness (p-value=0.041), quality of sleep (p-value<0.001), and the 6-minute walk test (p-value=0.004) was also observed in the group under intervention in comparison with the control. The Stress Reduction, Meditation, and Mindfulness Program effectively reduced perceived stress and improved clinical outcomes in patients with chronic Heart Failure.


A Insuficiência Cardíaca é um importante problema de saúde pública, que leva à alta carga de sintomas físicos e psicológicos, apesar da terapia otimizada. Avaliar primariamente o impacto de um Programa de Redução de Estresse, Meditação e Atenção plena na redução do estresse de pacientes com Insuficiência Cardíaca. Ensaio clínico randomizado e controlado que avaliou o impacto de um programa de redução de estresse comparado ao atendimento multidisciplinar convencional, em dois centros especializados no Brasil. O período de coleta de dados ocorreu entre abril e outubro de 2019. Um total de 38 pacientes foram alocados nos grupos de intervenção ou controle. A intervenção aconteceu ao longo de 8 semanas. O protocolo consistiu na avaliação das escalas de estresse percebido, depressão, qualidade de vida, ansiedade, atenção plena, qualidade do sono, teste de 6 minutos de caminhada e biomarcadores por um grupo cego, considerando um p-valor <0,05 como estatisticamente significativo. A intervenção resultou em redução significativa no estresse percebido de 22,8 ± 4,3 para 14,3 ± 3,8 pontos na escala de estresse percebido no grupo de intervenção vs. 23,9 ± 4,3 para 25,8 ± 5,4 no grupo controle (p-valor<0,001). Foi observada melhora significativa na qualidade de vida (p-valor=0,013), atenção plena (p-valor=0,041), qualidade do sono (p-valor<0,001) e no teste de 6 minutos de caminhada (p-valor=0,004) no grupo sob intervenção comparado com o controle. O Programa de Redução de Estresse, Meditação e Atenção plena reduziu efetivamente o estresse percebido e melhorou desfechos clínicos em pacientes com Insuficiência Cardíaca.


Assuntos
Insuficiência Cardíaca , Meditação , Atenção Plena , Humanos , Meditação/métodos , Meditação/psicologia , Estresse Psicológico/terapia , Atenção Plena/métodos , Qualidade de Vida , Insuficiência Cardíaca/terapia
2.
Arq. bras. cardiol ; 120(10): e20220768, 2023. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1520125

RESUMO

Resumo Fundamento A Insuficiência Cardíaca é um importante problema de saúde pública, que leva à alta carga de sintomas físicos e psicológicos, apesar da terapia otimizada. Objetivo Avaliar primariamente o impacto de um Programa de Redução de Estresse, Meditação e Atenção plena na redução do estresse de pacientes com Insuficiência Cardíaca. Métodos Ensaio clínico randomizado e controlado que avaliou o impacto de um programa de redução de estresse comparado ao atendimento multidisciplinar convencional, em dois centros especializados no Brasil. O período de coleta de dados ocorreu entre abril e outubro de 2019. Um total de 38 pacientes foram alocados nos grupos de intervenção ou controle. A intervenção aconteceu ao longo de 8 semanas. O protocolo consistiu na avaliação das escalas de estresse percebido, depressão, qualidade de vida, ansiedade, atenção plena, qualidade do sono, teste de 6 minutos de caminhada e biomarcadores por um grupo cego, considerando um p-valor <0,05 como estatisticamente significativo. Resultados A intervenção resultou em redução significativa no estresse percebido de 22,8 ± 4,3 para 14,3 ± 3,8 pontos na escala de estresse percebido no grupo de intervenção vs. 23,9 ± 4,3 para 25,8 ± 5,4 no grupo controle (p-valor<0,001). Foi observada melhora significativa na qualidade de vida (p-valor=0,013), atenção plena (p-valor=0,041), qualidade do sono (p-valor<0,001) e no teste de 6 minutos de caminhada (p-valor=0,004) no grupo sob intervenção comparado com o controle. Conclusão O Programa de Redução de Estresse, Meditação e Atenção plena reduziu efetivamente o estresse percebido e melhorou desfechos clínicos em pacientes com Insuficiência Cardíaca.


Abstract Background Heart Failure is a significant public health problem leading to a high burden of physical and psychological symptoms despite optimized therapy. Objective To evaluate primarily the impact of a Stress Reduction, Meditation, and Mindfulness Program on stress reduction of patients with Heart Failure. Methods A randomized and controlled clinical trial assessed the effect of a stress reduction program compared to conventional multidisciplinary care in two specialized centers in Brazil. The data collection period took place between April and October 2019. Thirty-eight patients were included and allocated to the intervention or control groups. The intervention took place over 8 weeks. The protocol assessed the scales of perceived stress, depression, quality of life, anxiety, mindfulness, quality of sleep, a 6-minute walk test, and biomarkers analyzed by a blinded team, considering a p-value <0.05 statistically significant. Results The intervention resulted in a significant reduction in perceived stress from 22.8 ± 4.3 to 14.3 ± 3.8 points in the perceived stress scale-14 items in the intervention group vs. 23.9 ± 4.3 to 25.8 ± 5.4 in the control group (p-value<0.001). A significant improvement in quality of life (p-value=0.013), mindfulness (p-value=0.041), quality of sleep (p-value<0.001), and the 6-minute walk test (p-value=0.004) was also observed in the group under intervention in comparison with the control. Conclusion The Stress Reduction, Meditation, and Mindfulness Program effectively reduced perceived stress and improved clinical outcomes in patients with chronic Heart Failure.

3.
Arq Neuropsiquiatr ; 63(2B): 427-9, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16059593

RESUMO

OBJECTIVE: Although its role is a matter of debate, some studies described a higher prevalence of patent foramen ovale (PFO) and atrial septal aneurysm (ASA) in young stroke patients, with higher risk with PFO / ASA association (OR 4.96). The aim of this study was determine the prevalence of PFO and ASA in a cohort of cryptogenic ischemic stroke (IS) patients younger than 55 years and to follow-up after surgical or percutaneous endovascular closure (PEC). METHOD: In 21 months we identified all patients less than 55 years old with IS who were admitted to our hospital. Cryptogenic IS was considered if there is not an identifiably cause to cerebral ischemia. Transesophageal echocardiography (TEE) was performed in all patients. After interatrial septal abnormalities diagnosis, percutaneous device closure was offered to all. Patients were followed monthly and keeped with oral AAS or Clopidogrel. RESULTS: We identified 189 patients with IS and 32 were less than 55 years old (16.9%). In 29 the IS was cryptogenic. TEE was performed in all patients and some form of interatrial septal abnormality was identified in 12 (12/29 - 41.3%); 5 had a PFO and in 7 there was PFO plus ASA. Ten patients were submitted to PEC and 2 were submitted to surgical closure. In mid-term follow-up (28 months) no ischemic events occurred and 2 patients related disappearance of migraine symptoms. CONCLUSION: Our small series description is in accordance with other studies and suggests a possible relation between interatrial septal abnormalities and IS in a cohort of young patient.


Assuntos
Isquemia Encefálica/etiologia , Comunicação Interatrial/epidemiologia , Aneurisma Intracraniano/epidemiologia , Adulto , Brasil/epidemiologia , Estudos de Coortes , Feminino , Comunicação Interatrial/complicações , Humanos , Aneurisma Intracraniano/complicações , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Prospectivos , Acidente Vascular Cerebral/etiologia
4.
Arq Bras Cardiol ; 85(3): 174-9, 2005 Sep.
Artigo em Português | MEDLINE | ID: mdl-16200263

RESUMO

OBJECTIVE: To assess the initial experiment with percutaneous closure of interventricular septal defects (IVSD), especially perimembranous IVSD (PMIVSD) with the new Amplatzer prosthesis. METHODS: Eleven patients were submitted to the procedure. Six of them had perimembranous IVSD (PMIVSD) and five with muscular IVSD (MIVSD). Two showed repeated respiratory tract infections and had low ponderal gain. One of them showed a previous history of infectious endocarditis. The others were asymptomatic and were selected through transthoracic echocardiography (TTE). RESULTS: In MIVSD group (n = 5), a patient had apical IVSD, two had medioseptal defects and two patients showed multiple defects. In this group, an interatrial septal defects (IASD) (Amplatzer Septal Occluder) and five prostheses for MIVSD (Amplatzer VSD-MUSC Occluder), and one patient received two devices. All implants were well-succeeded and went by without complications. In PMIVSD group (n = 6), two patients had membranous septal aneurysms. In five, we identified two orifices with selective angiography. We used arterial canal Amplatzer prostheses (ACP) (Amplatzer Duct Occluder) in 1 patient and specific prostheses for PMIVSD in the others (Amplatzer VSD-MEMB Occluder). A perimembranous occluder migrated immediately after released, being removed from the descending aorta. Another patient showed total atrioventricular block (TAVB), which reversed after corticotherapy. CONCLUSION: The procedure is technically complex and must be performed only in specialized centers. Despite of that, it showed safe and efficient in the selected cases, and it can be provided as an alternative to traditional surgical treatment.


Assuntos
Comunicação Interventricular/cirurgia , Próteses e Implantes , Implantação de Prótese/métodos , Adolescente , Adulto , Cateterismo Cardíaco , Criança , Pré-Escolar , Ecocardiografia , Feminino , Comunicação Interventricular/diagnóstico por imagem , Humanos , Lactente , Masculino , Resultado do Tratamento
5.
Arq Bras Cardiol ; 81(5): 435-52, 2003 Nov.
Artigo em Inglês, Português | MEDLINE | ID: mdl-14666265

RESUMO

OBJECTIVE: To evaluate the initial clinical experience with the Helex septal occluder for percutaneous closure of atrial septal defects. METHODS: Ten patients underwent the procedure, 7 patients with ostium secundum atrial septal defects (ASD) with hemodynamic repercussions and 3 patients with pervious foramen ovale (PFO) and a history of stroke. Mean age was 33.8 years and mean weight was 55.4 kg. Mean diameter by transesophageal echocardiography and mean stretched ASD diameter were 11.33 3.3mm, and 15.2 3.8mm, respectively. The Qp/Qs ratio was 1.9 0.3 in patients with ASD. RESULTS: Eleven occluders were placed because a patient with 2 holes needed 2 devices. It was necessary to retrieve and replace 4 devices in 3 patients. We observed immediate residual shunt (< 2mm) in 4 patients with ASD, and in those with patent foramen ovale total occlusion of the defect occurred. No complications were noted, and all patients were discharged on the following day. After 1 month, 2 patients with ASD experienced trivial residual shunts (1mm). In 1 patient, we observed mild prolapse in the proximal disk in the right atrium, without consequences. CONCLUSION: The Helex septal occluder was safe and effective for occluding small to moderate atrial septal defects. Because the implantation technique is demanding, it requires specific training of the operator. Even so, small technical failures may occur in the beginning of the learning curve, but they do not involve patient safety.


Assuntos
Cateterismo Cardíaco/instrumentação , Comunicação Interatrial/terapia , Próteses e Implantes , Adolescente , Adulto , Análise de Variância , Angiocardiografia , Brasil , Cateterismo Cardíaco/métodos , Criança , Pré-Escolar , Fluoroscopia , Seguimentos , Átrios do Coração/diagnóstico por imagem , Comunicação Interatrial/diagnóstico por imagem , Humanos
6.
Rev. bras. cardiol. invasiva ; 22(4): 382-385, Oct-Dec/2015. graf
Artigo em Português | LILACS, SES-SP | ID: lil-744578

RESUMO

A oclusão do apêndice atrial esquerdo tem sido realizada com sucesso para a prevenção de fenômenos embólicos em pacientes com fibrilação atrial, como alternativa à anticoagulação oral. O acesso atrial, através de forame oval ou comunicação interatrial tipo ostium secundum, tem sido evitado em função da crença de que o posicionamento do dispositivo é dificultado pela disposição mais alta do forame no septo interatrial. Neste manuscrito, relatamos um caso em que foram ocluídos, sequencialmente, o apêndice atrial esquerdo e o forame oval sem a necessidade de punção transeptal, que simplificou e tornou mais seguro o procedimento.


Left atrial appendage occlusion has been successfully employed to prevent embolic events in patients with atrial fibrillation as an alternative to oral anticoagulation. Left atrial access through the patent foramen ovale or ostium secundum atrial septal defect has been discouraged due to the fear that entering the septum in a higher position through the foramen would prevent adequate device positioning. In this manuscript we report a case in which the left atrial appendage and the foramen ovale were sequentially occluded avoiding transseptal puncture, making the procedure simpler and faster.


Assuntos
Humanos , Feminino , Idoso , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/terapia , Forame Oval Patente/fisiopatologia , Próteses e Implantes , Cateterismo Cardíaco , Comunicação Interatrial , Átrios do Coração/fisiopatologia
7.
Rev. bras. cardiol. invasiva ; 20(3): 309-314, 2012. ilus, tab
Artigo em Português | LILACS, SES-SP | ID: lil-656096

RESUMO

INTRODUÇÃO: Neste trabalho os autores visam a apresentar sua experiência inicial com o uso da nova prótese CARDIA UltraseptTM para fechamento percutâneo do forame oval. MÉTODOS: Foram selecionados por ecocardiograma transesofágico pacientes portadores de forame oval com eventos embólicos prévios, de qualquer idade e peso, ou enxaqueca de difícil controle clínico. Os critérios de eficácia incluíram ausência de shunt residual pelo ecocardiograma transesofágico com teste de microbolhas após seis meses e ausência de recidiva de eventos neurológicos. Não foram excluídos pacientes com base em dados morfológicos do forame oval. RESULTADOS: De abril de 2011 a maio de 2012 foram submetidos ao procedimento de oclusão 22 pacientes (6 do sexo masculino e 16 do sexo feminino) com idades entre 16 e 68 anos. Apenas uma paciente não tinha antecedente de acidente vascular cerebral ou ataque isquêmico transitório e sim enxaqueca de difícil controle clínico. Nenhum paciente apresentou aneurisma de septo atrial. Foi possível o implante em todos os casos, sendo utilizados 23 dispositivos. O dispositivo mais utilizado foi o de 25 mm. Apenas um paciente ficou com shunt residual ao ecocardiograma de um mês e continua em seguimento. Não houve recidivas de eventos até o momento. Houve duas complicações menores e não houve óbitos. CONCLUSÕES: O dispositivo CARDIA UltraseptTM é seguro, de fácil manuseio e eficaz. Ainda necessita ser mais bem avaliado em casos mais complexos, como os forames ovais maiores e com aneurisma do septo atrial.


BACKGROUND: The purpose of this study is to report the early experience with the use of the new CARDIA UltraseptTM device for percutaneous occlusion of patent foramen ovale. METHODS: Patients with patent foramen ovale with previous embolic events, of any age or weight, or migraine with poor clinical control, were selected by transesophageal echocardiography. Efficacy criteria included lack of residual shunt at the transesophageal echocardiogram with microbubble testing after 6 months and no recurrence of neurologic events. No patients were excluded based on morphological patent foramen ovale criteria. RESULTS: From April 2011 to May 2012, 22 patients (6 males and 16 females) with ages ranging from 16 to 68 years were submitted to the occlusion procedure. Only one patient had no history of stroke or transient ischemic attack, but migraine with poor clinical response. None of the patients had atrial septal aneurysms. The device was implanted in all cases, 23 devices were used and the 25 mm device was used most often. Only one patient presented residual shunt at the 1-month follow-up echocardiogram and remains under observation. There have been no recurrences to date. There were two minor complications and no deaths. CONCLUSIONS: The CARDIA UltraseptTM device is safe, effective and easy to use. It must be further evaluated in more complex cases, such as larger patent foramen ovales and with atrial septal aneurysms.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Próteses e Implantes , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco , Forame Oval Patente/complicações , Ecocardiografia/métodos , Ecocardiografia , Estudos Prospectivos
8.
Congenit Heart Dis ; 1(5): 239-43, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18377532

RESUMO

BACKGROUND: The new Amplatzer device has been used with success for occlusion of the perimembranous ventricular septal defects and the index of complications is very low. RESULTS: The reported case corresponds to a very rare severe acute tricuspid stenosis, caused by adherence of the prosthesis to the anterior tricuspid leaflet. CONCLUSION: Device release was achieved by manipulation on the tricuspid apparatus.


Assuntos
Oclusão com Balão/efeitos adversos , Comunicação Interventricular/terapia , Próteses e Implantes/efeitos adversos , Estenose da Valva Tricúspide/etiologia , Doença Aguda , Pré-Escolar , Remoção de Dispositivo , Ecocardiografia Transesofagiana , Humanos , Oxigênio/sangue
9.
Rev. bras. cardiol. invasiva ; 19(3): 308-316, set. 2011. ilus, tab
Artigo em Português | LILACS | ID: lil-607269

RESUMO

Introdução: A oclusão percutânea das comunicações interventriculares (CIVs) surgiu como uma alternativa ao tratamento cirúrgico ainda na década de 1980. Durante o implante da prótese por via anterógrada, a formação de uma alça arteriovenosa com a guia é tecnicamente difícil e demanda tempo. O objetivo deste estudo foi apresentar a experiência dos autores com a via retrógada e mostrar sua exequibilidade nos diversos tipos de CIV. Métodos: Foram incluídos pacientes portadores de defeitos do septo interventricular, que não apresentassem outros defeitos associados. Os casos foram selecionados por meio de ecocardiografia transtorácica. Resultados: No total, 8 pacientes foram submetidos ao procedimento, 4 portadores de CIV muscular e 4 portadores de CIV perimembranosa. Metade era do sexo masculino, as idades variaram de 7 anos a 32 anos (18,6 ± 7,8 anos) e os pesos, de 30 kg a 97 kg (66,12 ± 24,7 kg). Os diâmetros dos defeitos variaram de 2 mm a 8,6 mm (5 ± 2,4 mm). O implante foi possível em todos os casos, e a prótese mais utilizada foi a Lifetech CeraTM tipo I. As próteses AmplatzerTM Muscular VSD Occluder e Lifetech CeraTM tipo II também foram empregadas. Duas próteses embolizaram imediatamente após o implante e foram retiradas. Oclusão imediata ocorreu em 75%. Uma paciente apresentou bloqueio atrioventricular total na semana seguinte ao procedimento. Foi tratada com esteroides, obtendo a reversão para ritmo sinusal. Conclusões: A utilização da via retrógrada mostrou-se eficaz na oclusão de todos os tipos morfológicos de CIV com próteses de duplo disco. Os autores sugerem essa técnica como alternativa para a oclusão percutânea das CIVs de qualquer morfologia.


BACKGROUND: Transcatheter occlusion of ventricular septal defects (VSDs) was developed as an alternative to surgical treatment in the 80's. During anterograde device implantation, the formation of an arteriovenous loop with a guide-wire is technically difficult and time consuming. The aim of this study is to present the authors' experience with the retrograde approach and demonstrate its feasibility in different types of VSD. METHODS: Patients with VSD with no other associated defects were included in the study. Cases were selected by transthoracic echocardiograms. RESULTS: A total of eight patients were submitted to the procedure, 4 with muscular VSD and 4 with perimembranous VSD. Half of them were male, with ages ranging from 7 to 32 years (18.6 ± 7.8 years) and weight ranging from 30 to 97 kg (66.12 ± 24.7 kg). The defect diameter ranged from 2 to 8.6 mm (5 ± 2.4 mm). Implantation was possible in all patients and the most commonly used device was Lifetech CeraTM Type I. AmplatzerTM Muscular VSD Occluder, and Lifetech CeraTM Type II devices were also used. Two devices embolized immediately after implantation and were snared out. There was immediate occlusion in 75% of the cases. One patient had a complete atrioventricular block in the week following the procedure. The patient was treated with steroids, and was reverted to normal sinus rhythm. CONCLUSIONS: Retrograde transcatheter VSD occlusion with double disk devices proved to be effective in different types of VSD. The authors suggest this technique as an alternative to percutaneous occlusion of all types of VSD.


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Adulto , Próteses e Implantes , Cardiopatias Congênitas/cirurgia , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco , Comunicação Interventricular/cirurgia , Comunicação Interventricular/complicações , Ecocardiografia/métodos , Ecocardiografia , Fatores de Risco
10.
Rev. bras. cardiol. invasiva ; 18(4): 448-455, dez. 2010. ilus, tab
Artigo em Português | LILACS | ID: lil-582213

RESUMO

INTRODUÇÃO: Apesar do sucesso das intervenções por cateter nos defeitos congênitos em geral, a possibilidade de se dispor de um dispositivo percutaneamente implantável e que desapareça sem deixar vestígios é altamente desejável. Neste estudo apresentamos a experiência inicial dos autores com uma nova prótese parcialmente bioabsorvível. Método: Foram selecionados pacientes portadores de forame oval patente (FOP) com pelo menos um evento embólico prévio, sem defeitos associados, passíveis de correção cirúrgica. O diagnóstico foi feito por meio de ecocardiograma transesofágico (ETE) e teste de bolhas. Durante o procedimento as próteses foram escolhidas de acordo com as medidas de comprimento e abertura do FOP, ao ETE. O seguimento foi realizado por meio de avaliação clínica e ecocardiograma transtorácico com um mês e três meses de ETE aos seis meses após o implante. Os pacientes utilizaram a associação de ácido acetilsalicilico e clopidogrel por três meses a ácido acetilsalicilico isolado nos três meses subsequentes. A profilaxia antimicrobiana...


BACKGROUND: Despite the overall high success rate of per-cutaneous intervention in congenital defects, the possibility of having a percutaneous bioabsorbable implantable device is extremely desirable. The initial experience of the authors with a new partially bioabsorbable prosthesis is reported in this study. METHOD: Patients with patent foramen ovale (PFO), with at least one previous embolic event, without additional surgical defects were selected. Diagnosis was made by transesophageal echocardiography (TEE) and the bubble test. Devices were chosen according to length and opening of PFO at the TEE. Patients were followed-up by transthoracic echocardiogram at 1 and 3 months and TEE at 6 months post implantation. Patients received a combination of acetylsalicylic acid and clopidogrel for 3 months and acetylsalicylic acid for another 3 months. Patients were maintained on antimicrobial prophylaxis for infectious endocarditis for 6 months. RESULTS: Nine patients (5 male and 4 female) were treated from February to August 2010. Mean age was 43.4 ± 13.5 years and mean weight was 71.4 ± 16.3 kg. Pulmonary arterial pressure was normal in all of the patients. PFO tunnel lengths ranged from 6-11 mm and the opening ranged from 2-3 mm. Mean range from rest to stretched PFO opening was 2.1 ± 0.8 mm. Prosthesis implantation was possible in all of the cases. Thirteen devices were used in 9 patients, and one of them required a second device for an additional orifice. No major complications or procedure-related deaths were observed. CONCLUSION: The use of the BioSTAR TM device was safe and effective. It is an excellent alternative for PFO closure.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Próteses e Implantes , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco , Forame Oval Patente/complicações , Forame Oval Patente/diagnóstico , Ecocardiografia/métodos , Ecocardiografia , Estudos Prospectivos
11.
Rev. bras. cardiol. invasiva ; 17(1): 94-101, jan.-mar. 2009. ilus, tab
Artigo em Português | LILACS, SES-SP | ID: lil-521590

RESUMO

Neste trabalho, é apresentada a experiência inicial do grupo com a prótese atriasept-CARDIA para o fechamento de comunicação interatrial (CIA). É descrita a técnica de implante e são analisadas as características desse dispositivo. Escolhemos pacientes que apresentavam defeitos com diâmetro estático não maior que 15mm, sem hipertensão arterial pulmonar grave ou outros defeitos congênitos passíveis de correção cirúrgica...


Background: The authors's early experience with AtriaseptCARDIATM for the closure of atrial septal defects (ASD) is reported. Procedural implant technique is described and some technical aspects of this new device are analyzed. Methods: Selection criteria included defects with static diameter up to 15 mm on transesophageal echocardiography, without significant pulmonary hypertension, in absence of other congenital cardiac defects requiring surgical therapy...


Assuntos
Humanos , Masculino , Feminino , Criança , Cateterismo Cardíaco , Comunicação Interatrial/história , Aspirina/administração & dosagem , Seguimentos
12.
Rev. bras. cardiol. invasiva ; 17(3): 378-385, jul.-set. 2009. ilus, tab
Artigo em Português | LILACS | ID: lil-535098

RESUMO

Introdução: O fechamento percutâneo é, atualmente, o método terapêutico de escolha para o tratamento das comunicações interventriculares (CIVs) de tamanhos pequeno a moderado, na maioria dos serviços de cardiologia que dispõem de equipes treinadas em intervenção. Apesar da exequibilidade do método e dos excelentes resultados obtidos a curto e médio prazos, houve relato de bloqueio atrioventricular total em algumas séries, o que indicou a necessidade de novos tipos de dispositivo para essa finalidade. Neste trabalho, os autores apresentam sua experiência inicial com a prótese Nit-OccludTM Lê VSD Spiral Coil (PFM, Colônia, Alemanha). É descrita a técnica de implante e são feitas algumas considerações sobre o procedimento. Método: Foram selecionados pacientes com mais de dois anos de idade e/ou 15 kg de peso corporal, portadores de CIV perimembranosa diagnosticada e analisada morfologicamente pela ecocardiografia, no período de outubro de 2008 a maio de 2009. Resultados: O implante foi possível em cinco pacientes, sendo quatro do sexo masculino e apenas um do sexo feminino, com idades variando de 10 a 50 anos. Existia formação aneurismática em três casos. O orifíciode saída dos defeitos variou de 3 mm a 6 mm. Houve apenas um shunt residual imediato, que desapareceu no final do primeiro mês. Não houve distúrbios de condução ou bloqueioatrioventricular em nenhum caso...


ackground: Percutaneous closure is currently the therapeutic method of choice for the treatment of small to moderate sized ventricular septal defects (VSD), all over the world. Despite the ease of use and the excellent short and mid-term results described by most of the authors, third-degree atrioventricular block developed in a small number of cases, making a different kind of device desirable. In this paper the authors present their initial experience with the Nit-OccludTM Lê VSD Spiral Coil (PFM, Cologne, Germany). Implant technique is described and some other technical considerations are made. Methods: From October 2008 to May 2009 five patients older than two years of age and weighting over 15 kg were selected. They all had perimembranous VSDs diagnosed by transthoracic echocardiography. Results: Implant was possible in five patients. The male to female ratio was 4:1. Ages ranged from 10 to 50 years old. Aneurysms of the ventricular membranous septum were present in three cases. Right ventricular outlet diameter (effective orifice) ranged from 3 to 6 mm. There was only one immediate residual shunt that disappeared at the end of the first month. There was no bundle branch blocks or third-degree atrioventricular blocks. C..


Assuntos
Humanos , Masculino , Feminino , Criança , Adulto , Pessoa de Meia-Idade , Próteses e Implantes , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco , Comunicação Interventricular/cirurgia , Ecocardiografia/métodos , Ecocardiografia
13.
Rev. bras. cardiol. invasiva ; 16(1): 77-85, jan.-mar. 2008. tab, ilus
Artigo em Português | LILACS | ID: lil-489318

RESUMO

Introdução: O fechamento percutâneo das comunicações interatriais (CIAs) é uma alternativa à cirurgia, aceita em todo o mundo. O uso de mais de uma prótese tem sido descrito, mas ainda há poucos estudos sobre o assunto, especialmente no que diz respeito ao seguimento a longo prazo. Neste trabalho, apresentamos nossa experiência com o uso de mais de uma prótese para o fechamento dos defeitos atriais múltiplos, e discutimos as diferentes condições em que isso se faz necessário. Método: Este é um estudo retrospectivo, em que foram analisados todos os casos submetidos a fechamento percutâneo de CIAs, no período de abril de 1999 a dezembro de 2007. Do total de casos, selecionamos aqueles portadores de defeitos múltiplos, concentrando nosso relato nos que necessitaram de mais de uma prótese para sua oclusão. Incluímos, também, dois casos de pacientes com shunt residual após o implante prévio de uma primeira prótese e que necessitaram de um segundo dispositivo. Os casos foram todos selecionados por meio de ecocardiogramas transesofágicos (ETE). Resultados: No período mencionado, 211 pacientes foram submetidos a fechamento percutâneo de CIAs. Em 12 (5,6%) desses pacientes foi preciso utilizar duas próteses para oclusão de seus defeitos, como se segue: oito pacientes tinham dois orifícios; dois tinham três orifícios; e dois tinham quatro orifícios. A média das idades foi de 27,5 ± 14,6 anos. Dois casos apresentaram acidentes isquêmicos cerebrais prévios. Foram utilizadas 24 próteses, sendo 23 Amplatzer para CIAs e uma Amplatzer para forame oval (FOP). O implante foi possível em todos os casos. O diâmetro dos orifícios menores era de 10,5 ± 4,0 mm e dos maiores, de 20,6 ± 5,5 mm. O diâmetro central das próteses de CIA variou de 5 mm a 34 mm (16,8 ± 7,6 mm). Não houve complicações graves ou óbitos. Shunt residual imediato estava presente em dois (16,6%) pacientes. Foram acrescentados à casuística mais dois casos de shunt residual significativo, fechados, com suce...


Introduction: Transcatheter Atrial Septal Defect (ASD) closure is a worldwide accepted alternative to surgical repair. The use of more than one device has been described, however, there are just a limited number of studies available with a long term follow-up. In this study, the authors present their experience in transcatheter closure of multiple atrial septal defects utilizing more than one device, and discuss the different situations where this approach has become necessary. Methods: This is a retrospective study where all patients submitted to ASD device closure from April 1999 to December 2007 were analyzed. We selected those with multiple ASD and focused our study on those who had two devices implanted. We also included two patients who had significant residual shunts after the first procedure and were closed with a second device. All patients were selected based on transesophageal echocardiogram (TEE) results. Results: In the aforementioned period, 211 patients were submitted to transcatheter ASD closure. Twelve (5.6%) patients needed two devices to close their defects, described as follows: eight patients had 2 orifices, two had 3 orifices, and two had 4 orifices. Mean age was 27.5 ± 14.6 years. Two patients suffered ischemic cerebral events (stroke) prior to occlusion. Twenty-four devices were utilized: 23 Amplatzer ASD Occluder devices and one 25mm Amplatzer PFO Occluder device. The device implantation was possible in all cases. Average diameter for small defects was 10.5 ± 4.0 mm, and 20.6 ± 5.5 mm for larger defects. Mean central diameter of the devices varied from 5 to 34 mm (16.8 ± 7.6 mm). There were no major complications or deaths related to the procedure. Immediate post-procedural residual shunts were present in two (16.6%) patients. Two additional patients were included with significant residual shunt that required a second Amplatzer ASD device. Conclusion: Although technically more demanding, two device ASD closure is feasible, safe and...


Assuntos
Humanos , Masculino , Feminino , Adulto , Próteses e Implantes , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco , Comunicação Interatrial/cirurgia
14.
Arq. neuropsiquiatr ; 63(2b)jun. 2005. tab
Artigo em Inglês | BVSCARGA, FIOCRUZ | ID: car-626

RESUMO

OBJETIVO: A associação das anormalidades do septo interatrial - forame oval patente (FOP) e aneurisma de septo interatrial (ASA) - com acidente vascular cerebral isquêmico (AVCI) ainda é questão de incerteza para muitos autores. No entanto, vários estudo mostram que em pacientes jovens tais anormalidades podem estar relacionadas à gênese de eventos isquêmicos. Nosso objetivo é descrever a prevalência do FOP e ASA em uma coorte de pacientes jovens (< 55 anos) com AVCI e acompanhar estes pacientes após fechamento cirúrgico ou por prótese endovascular. MÉTODO: Em 21 meses de estudo, identificamos todos os pacientes com menos de 55 anos de idade admitidos em nosso hospital por AVCI. Consideramos AVCI como criptogenético quando não havia uma causa provável para AVCI. Todos os pacientes foram submetidos ao ecocardiograma transesofágico. O fechamento por prótese endovascular foi o procedimento oferecido àqueles com alguma anormalidade do septo interatrial. Os pacientes foram acompanhados mensalmente e submetidos a antiagregação plaquetária com AAS ou clopidogrel. RESULTADOS: Foram admitidos 32 pacientes jovens com AVCI. Após ampla investigação, 29 receberam o diagnóstico de AVCI criptogênico. Destes, 12 (12/29 - 41,3%) apresentaram alguma anormalidade do septo interatrial; sendo que em 7 havia a associação de FOP e ASA. Dez pacientes foram submetidos a fechamento endovascular percutâneo e 2 foram submetidos a fechamento cirúrgico. Até o momento, nenhum paciente relatou recorrência do evento isquêmico e 2 pacientes relataram melhora das crises de enxaqueca (14 meses de seguimento). CONCLUSÃO: Nossa pequena série de casos está de acordo com outros estudos e sugere uma possível relação entre anormalidades do septo interatrial e AVCI em pacientes jovens. Maiores estudos são necessários para comprovar esta associação e para definir a melhor conduta terapêutica. (AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Isquemia Encefálica/etiologia , Comunicação Interatrial/epidemiologia , Aneurisma Intracraniano/epidemiologia , Brasil/epidemiologia , Estudos de Coortes , Comunicação Interatrial/complicações , Aneurisma Intracraniano/complicações , Prevalência , Estudos Prospectivos , Acidente Vascular Cerebral/etiologia
15.
Artigo em Inglês | ARCA | ID: arc-33622

RESUMO

Objetivo: A associação das anormalidades do septo interatrial - forame oval patente (FOP) e aneurisma de septo interatrial (ASA) - com acidente vascular cerebral isquêmico (AVCI) ainda é questão de incerteza para muitos autores. No entanto, vários estudo mostram que em pacientes jovens tais anormalidades podem estar relacionadas à gênese de eventos isquêmicos. Nosso objetivo é descrever a prevalência do FOP e ASA em uma coorte de pacientes jovens (< 55 anos) com AVCI e acompanhar estes pacientes após fechamento cirúrgico ou por prótese endovascular. Método: Em 21 meses de estudo, identificamos todos os pacientes com menos de 55 anos de idade admitidos em nosso hospital por AVCI. Consideramos AVCI como criptogenético quando não havia uma causa provável para AVCI. Todos os pacientes foram submetidos ao ecocardiograma transesofágico. O fechamento por prótese endovascular foi o procedimento oferecido àqueles com alguma anormalidade do septo interatrial. Os pacientes foram acompanhados mensalmente e submetidos a antiagregação plaquetária com AAS ou clopidogre l . R e s u l t a d o s : Foram admitidos 32 pacientes jovens com AVCI. Após ampla investigação, 29 receberam o diagnóstico de AVCI criptogênico. Destes, 12 (12/29 - 41,3%) apresentaram alguma anormalidade do septo interatrial; sendo que em 7 havia a associação de FOP e ASA. Dez pacientes foram submetidos a fechamento endovascular percutâneo e 2 foram submetidos a fechamento cirúrgico. Até o momento, nenhum paciente relatou recorrência do evento isquêmico e 2 pacientes relataram melhora das crises de enxaqueca (14 meses de seguimento). Conclusão: Nossa pequena série de casos está de acordo com outros estudos e sugere uma possível relação entre anormalidades do septo interatrial e AVCI em pacientes jovens. Maiores estudos são necessários para comprovar esta associação e para definir a melhor conduta terapêutica.

16.
Arq. neuropsiquiatr ; 63(2b)jun. 2005. tab
Artigo em Inglês | LILACS | ID: lil-404589

RESUMO

OBJETIVO: A associação das anormalidades do septo interatrial - forame oval patente (FOP) e aneurisma de septo interatrial (ASA) - com acidente vascular cerebral isquêmico (AVCI) ainda é questão de incerteza para muitos autores. No entanto, vários estudo mostram que em pacientes jovens tais anormalidades podem estar relacionadas à gênese de eventos isquêmicos. Nosso objetivo é descrever a prevalência do FOP e ASA em uma coorte de pacientes jovens (< 55 anos) com AVCI e acompanhar estes pacientes após fechamento cirúrgico ou por prótese endovascular. MÉTODO: Em 21 meses de estudo, identificamos todos os pacientes com menos de 55 anos de idade admitidos em nosso hospital por AVCI. Consideramos AVCI como criptogenético quando não havia uma causa provável para AVCI. Todos os pacientes foram submetidos ao ecocardiograma transesofágico. O fechamento por prótese endovascular foi o procedimento oferecido àqueles com alguma anormalidade do septo interatrial. Os pacientes foram acompanhados mensalmente e submetidos a antiagregação plaquetária com AAS ou clopidogrel. RESULTADOS: Foram admitidos 32 pacientes jovens com AVCI. Após ampla investigação, 29 receberam o diagnóstico de AVCI criptogênico. Destes, 12 (12/29 - 41,3%) apresentaram alguma anormalidade do septo interatrial; sendo que em 7 havia a associação de FOP e ASA. Dez pacientes foram submetidos a fechamento endovascular percutâneo e 2 foram submetidos a fechamento cirúrgico. Até o momento, nenhum paciente relatou recorrência do evento isquêmico e 2 pacientes relataram melhora das crises de enxaqueca (14 meses de seguimento). CONCLUSÃO: Nossa pequena série de casos está de acordo com outros estudos e sugere uma possível relação entre anormalidades do septo interatrial e AVCI em pacientes jovens. Maiores estudos são necessários para comprovar esta associação e para definir a melhor conduta terapêutica.


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Encefálica/etiologia , Comunicação Interatrial/epidemiologia , Aneurisma Intracraniano/epidemiologia , Brasil/epidemiologia , Estudos de Coortes , Comunicação Interatrial/complicações , Aneurisma Intracraniano/complicações , Prevalência , Estudos Prospectivos , Acidente Vascular Cerebral/etiologia
17.
Arq. bras. cardiol ; 85(3): 174-179, set. 2005.
Artigo em Português | LILACS, SES-SP | ID: lil-414344

RESUMO

OBJETIVO: Avaliar a experiência inicial com o fechamento percutâneo das comunicações interventriculares (CIV), em especial, das CIV perimembranosas (CIVPM) com a nova prótese de Amplatzer. MÉTODOS: Foram submetidos ao procedimento onze pacientes, seis com CIV perimembranosas (CIVPM) e cinco com CIV musculares (CIVM). Dois apresentavam infecções repetidas do trato respiratório e tinham baixo ganho ponderal. Um apresentou história prévia de endocardite infecciosa. Os demais eram assintomáticos e foram selecionados pela ecocardiografia transtorácica (ETT). RESULTADOS: No grupo das CIVM (n=5), um paciente tinha uma CIV apical, dois tinham defeitos médio-septais e dois pacientes apresentavam defeitos múltiplos. Neste grupo, foi utilizada uma prótese de comunicação interatrial (CIA) (Amplatzer Septal Occluder®) e cinco próteses para CIVM (Amplatzer VSD-MUSC Occluder®), sendo que uma mesma paciente recebeu dois dispositivos. Todos os implantes foram bem sucedidos e transcorreram sem complicações. No grupo das CIVPM (n=6), dois tinham aneurismas de septo membranoso. Em 5, identificamos dois pertuitos com angiografia seletiva. Utilizamos próteses de Amplatzer para canal arterial (PCA) (Amplatzer Duct Occluder®) em 1 paciente e próteses específicas para CIVPM nos demais (Amplatzer VSD-MEMB Occluder®). Um oclusor perimembranoso migrou imediatamente depois de liberado, sendo retirado da aorta descendente. Outro paciente apresentou bloqueio atrioventricular total (BAVT), que reverteu após corticoterapia. CONCLUSAO: O procedimento é tecnicamente complexo e deve ser executado apenas em centros especializados. Apesar disso, mostrou-se seguro e eficaz nos casos selecionados, e pode ser oferecido como alternativa ao tratamento cirúrgico tradicional.


Assuntos
Lactente , Pré-Escolar , Criança , Adolescente , Adulto , Humanos , Masculino , Feminino , Comunicação Interventricular/cirurgia , Próteses e Implantes , Implantação de Prótese/métodos , Ecocardiografia , Cateterismo Cardíaco , Comunicação Interventricular , Resultado do Tratamento
18.
Rev. bras. cardiol. invasiva ; 17(3): 378-385, 2009.
Artigo em Português | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1066946

RESUMO

O fechamento percutâneo é, atualmente, o método terapêutico de escolha para o tratamento das comunicações interventriculares (CIVs) de tamanhos pequeno a moderado, na maioria dos serviços de cardiologia que dispõem de equipes treinadas em intervenção. Apesar da exequibilidade do método e dos excelentes resultados obtidos a curto e médio prazos, houve relato de bloqueio atrioventricular total em algumas séries, o que indicou anecessidade de novos tipos de dispositivo para essa finalidade.Neste trabalho, os autores apresentam sua experiência inicial com a prótese Nit-OccludTM Lê VSD Spiral Coil (PFM, Colônia, Alemanha). É descrita a técnica de implante e são feitas algumas considerações sobre o procedimento.Método: Foram selecionados pacientes com mais de dois anos de idade e/ou 15 kg de peso corporal, portadores de CIV perimembranosa diagnosticada e analisada morfologicamente pela ecocardiografia, no período de outubro de 2008 a maio de 2009. Resultados: O implante foi possível em cinco pacientes, sendo quatro do sexo masculino e apenas um do sexo feminino, comidades variando de 10 a 50 anos. Existia formação aneurismática em três casos. O orifício de saída dos defeitosvariou de 3 mm a 6 mm. Houve apenas um shunt residual imediato, que desapareceu no final do primeiromês. Não houve distúrbios de condução ou bloqueio atrioventricular em nenhum caso. Conclusão: Ressalvando-se o pequeno número de casos e o curto tempo de seguimento, o uso do dispositivo Nit-OccludTM Lê VSD Spiral Coil mostrou-se seguro e eficaz na oclusão de CIVs perimembranosas restritivas.


Assuntos
Cateterismo Cardíaco , Comunicação Interventricular , Ecocardiografia , Próteses e Implantes
19.
Arq. bras. cardiol ; 81(5): 435-452, nov. 2003. ilus, tab
Artigo em Inglês, Português | LILACS, SES-SP | ID: lil-351136

RESUMO

OBJECTIVE: To evaluate the initial clinical experience with the Helex septal occluder for percutaneous closure of atrial septal defects. METHODS: Ten patients underwent the procedure, 7 patients with ostium secundum atrial septal defects (ASD) with hemodynamic repercussions and 3 patients with pervious foramen ovale (PFO) and a history of stroke. Mean age was 33.8 years and mean weight was 55.4 kg. Mean diameter by transesophageal echocardiography and mean stretched ASD diameter were 11.33 ± 3.3mm, and 15.2 ± 3.8mm, respectively. The Qp/Qs ratio was 1.9 ± 0.3 in patients with ASD. RESULTS: Eleven occluders were placed because a patient with 2 holes needed 2 devices. It was necessary to retrieve and replace 4 devices in 3 patients. We observed immediate residual shunt (< 2mm) in 4 patients with ASD, and in those with patent foramen ovale total occlusion of the defect occurred. No complications were noted, and all patients were discharged on the following day. After 1 month, 2 patients with ASD experienced trivial residual shunts (1mm). In 1 patient, we observed mild prolapse in the proximal disk in the right atrium, without consequences. CONCLUSION: The Helex septal occluder was safe and effective for occluding small to moderate atrial septal defects. Because the implantation technique is demanding, it requires specific training of the operator. Even so, small technical failures may occur in the beginning of the learning curve, but they do not involve patient safety


Assuntos
Humanos , Pré-Escolar , Criança , Adolescente , Adulto , Cateterismo Cardíaco/instrumentação , Comunicação Interatrial/terapia , Próteses e Implantes , Análise de Variância , Angiocardiografia , Brasil , Fluoroscopia , Seguimentos , Átrios do Coração , Cateterismo Cardíaco/métodos , Comunicação Interatrial
20.
Rev. SOCERJ ; 18(1): 77-81, Jan-Mar. 2005. tab
Artigo em Português | LILACS | ID: lil-407481

RESUMO

Objetivo: Dados encontrados na literatura sugerem que a terapia de reposição hormonal (TRH) pode promover alteração de repolarização e taquicardia ventricular. Como consequência houve um interesse na terapia com raloxifeno (R), um modulador seletivo do receptor do estrogênio, em função do seu potencial em apresentar a maioria dos efeitos benefícios do estrogênio, enquanto evita a maioria dos seus efeitos adversos.Métodos: Este estudo randomizado, duplo-cego e cruzado teve o objetivo de comparar o efeito do R com o TRH, no intervalo QT no eletrocardiograma, em 30 mulheres hipertensas, com idade média de 69 anos após um período run-in com hidroclorothiazida 12,5 mg uma vez ao dia. O intervalo QT foi corrigido(QTc) para a frequência cardíaca e a dispersão do QT(QTd) foi definida como a diferença entre os intervalos QT máximo e mínimo em quaisquer 2 derivações. As medidas foram realizadas no período basal, após 8 semanas de TRH (estradiol transdérmico+noretisterona) e após 8 semanas de R (60mg), com um período de wash-out entre as duas terapias.Resultados: verificou-se que R e TRH aumentaram QTc numa mesma extensão quando comparado aos níveis basais (p menor 0,05), embora não haja diferença significativa entre eles apesar dos valores de QTd.Conclusão: Os resultados encontrados neste estudo sugerem que o R e o TRH exercem os mesmos efeitos no intervalo QTc em mulheres hipertensas, em pós menopausa, não demonstrando qualquer efeito no QTd. Tal resultado deve encorajar futuros estudos para avaliar o impacto em eventos clínicos


Assuntos
Feminino , Idoso , Pressão Arterial/fisiologia , Cloridrato de Raloxifeno/farmacologia , Cloridrato de Raloxifeno/síntese química , Cloridrato de Raloxifeno/uso terapêutico , Terapia de Reposição Hormonal/métodos , Terapia de Reposição Hormonal/tendências , Terapia de Reposição Hormonal , Menopausa/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA