Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Heart Rhythm ; 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38762819

RESUMO

BACKGROUND: Conduction system pacing (CSP) by His bundle pacing or left bundle branch area pacing (LBBAP) is incorporated into Heart Rhythm Society guidelines for the management of bradycardia and cardiac resynchronization therapy. Despite increasing adoption with both lumenless leads and stylet-driven leads, concerns regarding the feasibility and safety of the extraction of CSP leads remain. OBJECTIVE: The aim of the study was to report on the safety, feasibility, and clinical outcomes of the extraction of CSP leads. METHODS: Patients undergoing the extraction of CSP leads from 10 international centers were enrolled in this retrospective study. Data regarding indications, lead location, lead type, extraction tools, procedural success, complications, and reimplantation in the conduction system were collected. RESULTS: Overall, 341 patients (age 69 ± 15 years; female 34%; cardiomyopathy 46%; lead dwell time 22 ± 26 months) underwent the extraction of 224 His bundle pacing and 117 LBBAP leads (lumenless leads 321; stylet-driven leads 20). Complete procedural success was achieved in 338 (99%), while clinical success was 100% with retained distal fragments in 3 patients (1%). Among patients with a lead dwell time of >6 months (6-193 months; n = 226), manual extraction was successful in 198 (87%), mechanical tools in 22 (10%), and laser in 6 (3%). Femoral tools were necessary in 3 patients. Minor complications occurred in 7 patients (2.1%). CSP reimplantation was successful in 233 of 244 patients attempted (95%). CONCLUSION: The overall success rates of the extraction of CSP leads were very high (although the LBBAP lead dwell time was <3 years), with a low need for extraction tools and minimal complication. Reimplantation in the conduction system is feasible and safe.

2.
J Innov Card Rhythm Manag ; 14(3): 5393-5396, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36998413

RESUMO

The mechanisms of wide complex tachycardia can vary. We discuss the case of a wide complex tachycardia with multiple mechanisms due to a rare genetic abnormality in a 26-year-old Caucasian man with a past history of spontaneous pneumothorax and syncope.

3.
JACC Case Rep ; 16: 101887, 2023 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-37396319

RESUMO

An 88-year-old woman underwent atrioventricular node ablation and left bundle branch pacing for atrial fibrillation. She presented to the emergency room several hours after discharge with dyspnea. An echocardiogram revealed a giant interventricular septal hematoma. The patient was successfully treated with conservative medical therapy, with eventual complete resolution of the hematoma. (Level of Difficulty: Intermediate.).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA