Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Biomed Instrum Technol ; 55(2): 69-84, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34043008

RESUMO

To ensure patient safety, medical device manufacturers are required by the Food and Drug Administration and other regulatory bodies to perform biocompatibility evaluations on their devices per standards, such as the AAMI-approved ISO 10993-1:2018 (ANSI/AAMI/ISO 10993-1:2018).However, some of these biological tests (e.g., systemic toxicity studies) have long lead times and are costly, which may hinder the release of new medical devices. In recent years, an alternative method using a risk-based approach for evaluating the toxicity (or biocompatibility) profile of chemicals and materials used in medical devices has become more mainstream. This approach is used as a complement to or substitute for traditional testing methods (e.g., systemic toxicity endpoints). Regardless of the approach, the one test still used routinely in initial screening is the cytotoxicity test, which is based on an in vitro cell culture system to evaluate potential biocompatibility effects of the final finished form of a medical device. However, it is known that this sensitive test is not always compatible with specific materials and can lead to failing cytotoxicity scores and an incorrect assumption of potential biological or toxicological adverse effects. This article discusses the common culprits of in vitro cytotoxicity failures, as well as describes the regulatory-approved methodology for cytotoxicity testing and the approach of using toxicological risk assessment to address clinical relevance of cytotoxicity failures for medical devices. Further, discrepancies among test results from in vitro tests, use of published half-maximal inhibitory concentration data, and the derivation of their relationship to tolerable exposure limits, reference doses, or no observed adverse effect levels are highlighted to demonstrate that although cytotoxicity tests in general are regarded as a useful sensitive screening assays, specific medical device materials are not compatible with these cellular/in vitro systems. For these cases, the results should be analyzed using more clinically relevant approaches (e.g., through chemical analysis or written risk assessment).


Assuntos
United States Food and Drug Administration , Humanos , Estados Unidos
2.
Risk Anal ; 36(8): 1520-37, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27510619

RESUMO

The Society for Risk Analysis (SRA) has a history of bringing thought leadership to topics of emerging risk. In September 2014, the SRA Emerging Nanoscale Materials Specialty Group convened an international workshop to examine the use of alternative testing strategies (ATS) for manufactured nanomaterials (NM) from a risk analysis perspective. Experts in NM environmental health and safety, human health, ecotoxicology, regulatory compliance, risk analysis, and ATS evaluated and discussed the state of the science for in vitro and other alternatives to traditional toxicology testing for NM. Based on this review, experts recommended immediate and near-term actions that would advance ATS use in NM risk assessment. Three focal areas-human health, ecological health, and exposure considerations-shaped deliberations about information needs, priorities, and the next steps required to increase confidence in and use of ATS in NM risk assessment. The deliberations revealed that ATS are now being used for screening, and that, in the near term, ATS could be developed for use in read-across or categorization decision making within certain regulatory frameworks. Participants recognized that leadership is required from within the scientific community to address basic challenges, including standardizing materials, protocols, techniques and reporting, and designing experiments relevant to real-world conditions, as well as coordination and sharing of large-scale collaborations and data. Experts agreed that it will be critical to include experimental parameters that can support the development of adverse outcome pathways. Numerous other insightful ideas for investment in ATS emerged throughout the discussions and are further highlighted in this article.


Assuntos
Ecotoxicologia , Saúde Ambiental , Nanoestruturas/química , Nanotecnologia/legislação & jurisprudência , Humanos , Medição de Risco , Segurança
3.
Toxicol In Vitro ; 69: 104995, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32891721

RESUMO

The ISO 10993 standards on biocompatibility assessment of medical devices discourage the use of animal tests when reliable and validated in vitro methods are available. A round robin validation study of in vitro reconstructed human epidermis (RhE) assays was performed as potential replacements for rabbit skin irritation testing. The RhE assays were able to accurately identify strong irritants in dilute medical device extracts. However, there was some uncertainty about whether RhE tissues accurately predicted the results of the rabbit skin patch or intracutaneous irritation test. To address that question, this paper presents in vivo data from the round robin and subsequent follow-up studies. The follow-up studies included simultaneous in vitro RhE model and in vivo testing of round robin polymer samples and the results of dual in vitro/in vivo testing of currently marketed medical device components/materials. Our results show for the first time that for both pure chemicals and medical device extracts the intracutaneous rabbit test is more sensitive to detect irritant activity than the rabbit skin patch test. The studies showed that the RhE models produced results that were essentially equivalent to those from the intracutaneous rabbit skin irritation test. Therefore, it is concluded that RhE in vitro models are acceptable replacements for the in vivo rabbit intracutaneous irritation test for evaluating the irritant potential of medical devices.


Assuntos
Alternativas aos Testes com Animais , Epiderme/efeitos dos fármacos , Equipamentos e Provisões/efeitos adversos , Irritantes/toxicidade , Testes de Irritação da Pele/métodos , Administração Tópica , Animais , Feminino , Ácidos Heptanoicos/toxicidade , Humanos , Técnicas In Vitro , Injeções Intradérmicas , Ácido Láctico/toxicidade , Masculino , Coelhos , Reprodutibilidade dos Testes
4.
Toxicol In Vitro ; 50: 426-432, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29180040

RESUMO

Skin irritation is an important component of the biological safety evaluation of medical devices. This testing has typically been performed using in vivo models. However, in an effort to reduce the need for in vivo testing, alternative methods for assessing skin irritation potential in vitro have been developed using a Reconstructed Human Epidermis (RhE) model. During the development of the protocol for the round robin validation of in vitro irritation testing for medical device extracts, it became clear that there were three points in the procedure where different options may be validated within each laboratory for routine testing: sample exposure time (18 vs 24h), SDS positive control concentration, and cytokine (IL-1α) release testing. The goal of our study was to evaluate the effect of these variables. EpiDerm™ tissues were exposed to extracts of three plain polymer samples, and four polymers embedded with known irritant chemicals. Exposures were performed for 18 and 24h. Resulting tissue viability was assessed by MTT reduction and IL-1α release was assessed by ELISA. Testing was also performed using various concentrations of SDS ranging from 0.5 to 1% (w/v). Overall, results were similar for samples tested and 18 and 24h, but the 18h exposure time has the potential to have an impact on the results of some sample types. IL-1α testing was shown to be useful to clarify conflicting tissue viability results. Use of a lower concentration of SDS as a positive control can help prevent issues that arise from excessive tissue damage often caused by 1% SDS.


Assuntos
Misturas Complexas/toxicidade , Epiderme/efeitos dos fármacos , Equipamentos e Provisões , Testes de Irritação da Pele/métodos , Alternativas aos Testes com Animais , Sobrevivência Celular/efeitos dos fármacos , Epiderme/metabolismo , Humanos , Interleucina-1alfa/metabolismo
5.
J Biomed Mater Res B Appl Biomater ; 106(8): 2807-2814, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29226582

RESUMO

In vivo and in vitro irritation testing is important for evaluating the biological safety of medical devices. Here, the performance of positive reference materials for skin irritation testing was evaluated. Four reference standards, referred to as Y-series materials, were analyzed: a polyvinyl chloride (PVC) sheet spiked with 0 (Y-1), 1.0 (Y-2), 1.5 (Y-3), or 10 (Y-4) parts of Genapol X-080 per 100 parts of PVC by weight. Y-1, Y-2, and Y-3 did not induce skin irritation responses in an in vitro reconstructed human epidermis (RhE) tissue model, as measured by tissue viability or interleukin-1α release, or in an in vivo intracutaneous response test using rabbits. In contrast, Y-4 extracts prepared with saline or sesame oil at 37°C and 50°C clearly elicited positive irritation responses, including reduced viability (< 50%) and significantly higher interleukin-1α release compared with the solvent alone group, in the RhE tissue model and an intracutaneous response test, where substantial necrosis was observed by histopathology. The positive skin irritation responses induced in vitro under various extraction conditions, as well as those elicited in vivo, indicate that Y-4 is an effective extractable positive control material for in vivo and in vitro skin irritation tests of medical devices. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 2807-2814, 2018.


Assuntos
Epiderme/metabolismo , Modelos Biológicos , Cloreto de Polivinila/química , Testes de Irritação da Pele/métodos , Animais , Epiderme/patologia , Humanos , Interleucina-1alfa/metabolismo , Masculino , Estudo de Prova de Conceito , Coelhos , Padrões de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA