Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
1.
Br J Surg ; 106(8): 1026-1034, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31134619

RESUMO

BACKGROUND: Patients undergoing amputation of the lower extremity for the complications of peripheral artery disease and/or diabetes are at risk of treatment failure and the need for reamputation at a higher level. The aim of this study was to develop a patient-specific reamputation risk prediction model. METHODS: Patients with incident unilateral transmetatarsal, transtibial or transfemoral amputation between 2004 and 2014 secondary to diabetes and/or peripheral artery disease, and who survived 12 months after amputation, were identified using Veterans Health Administration databases. Procedure codes and natural language processing were used to define subsequent ipsilateral reamputation at the same or higher level. Stepdown logistic regression was used to develop the prediction model. It was then evaluated for calibration and discrimination by evaluating the goodness of fit, area under the receiver operating characteristic curve (AUC) and discrimination slope. RESULTS: Some 5260 patients were identified, of whom 1283 (24·4 per cent) underwent ipsilateral reamputation in the 12 months after initial amputation. Crude reamputation risks were 40·3, 25·9 and 9·7 per cent in the transmetatarsal, transtibial and transfemoral groups respectively. The final prediction model included 11 predictors (amputation level, sex, smoking, alcohol, rest pain, use of outpatient anticoagulants, diabetes, chronic obstructive pulmonary disease, white blood cell count, kidney failure and previous revascularization), along with four interaction terms. Evaluation of the prediction characteristics indicated good model calibration with goodness-of-fit testing, good discrimination (AUC 0·72) and a discrimination slope of 11·2 per cent. CONCLUSION: A prediction model was developed to calculate individual risk of primary healing failure and the need for reamputation surgery at each amputation level. This model may assist clinical decision-making regarding amputation-level selection.


Assuntos
Amputação Cirúrgica/estatística & dados numéricos , Angiopatias Diabéticas/epidemiologia , Perna (Membro)/cirurgia , Doença Arterial Periférica/complicações , Reoperação/estatística & dados numéricos , Medição de Risco , Idoso , Tomada de Decisão Clínica , Angiopatias Diabéticas/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Doença Arterial Periférica/epidemiologia , Fatores de Risco
2.
Br J Surg ; 106(7): 879-888, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30865292

RESUMO

BACKGROUND: Patients who undergo lower extremity amputation secondary to the complications of diabetes or peripheral artery disease have poor long-term survival. Providing patients and surgeons with individual-patient, rather than population, survival estimates provides them with important information to make individualized treatment decisions. METHODS: Patients with peripheral artery disease and/or diabetes undergoing their first unilateral transmetatarsal, transtibial or transfemoral amputation were identified in the Veterans Affairs Surgical Quality Improvement Program (VASQIP) database. Stepdown logistic regression was used to develop a 1-year mortality risk prediction model from a list of 33 candidate predictors using data from three of five Department of Veterans Affairs national geographical regions. External geographical validation was performed using data from the remaining two regions. Calibration and discrimination were assessed in the development and validation samples. RESULTS: The development sample included 5028 patients and the validation sample 2140. The final mortality prediction model (AMPREDICT-Mortality) included amputation level, age, BMI, race, functional status, congestive heart failure, dialysis, blood urea nitrogen level, and white blood cell and platelet counts. The model fit in the validation sample was good. The area under the receiver operating characteristic (ROC) curve for the validation sample was 0·76 and Cox calibration regression indicated excellent calibration (slope 0·96, 95 per cent c.i. 0·85 to 1·06; intercept 0·02, 95 per cent c.i. -0·12 to 0·17). Given the external validation characteristics, the development and validation samples were combined, giving a total sample of 7168. CONCLUSION: The AMPREDICT-Mortality prediction model is a validated parsimonious model that can be used to inform the 1-year mortality risk following non-traumatic lower extremity amputation of patients with peripheral artery disease or diabetes.


Assuntos
Amputação Cirúrgica/mortalidade , Técnicas de Apoio para a Decisão , Pé Diabético/cirurgia , Extremidade Inferior/cirurgia , Doença Arterial Periférica/cirurgia , Adulto , Idoso , Bases de Dados Factuais , Pé Diabético/complicações , Pé Diabético/mortalidade , Feminino , Humanos , Modelos Logísticos , Extremidade Inferior/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/complicações , Doença Arterial Periférica/mortalidade , Modelos de Riscos Proporcionais , Curva ROC , Medição de Risco , Fatores de Risco , Resultado do Tratamento
3.
J Nanosci Nanotechnol ; 14(9): 6646-52, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25924311

RESUMO

The selective detection of dopamine (DA) is of great importance in the modern medicine because dopamine is one of the main regulators in human behaviour. In this study, ZnO/CuO nanohybrid structures, grown on the gold coated glass substrate, have been investigated as a novel electrode material for the electrochemical detection of dopamine. Scanning electron microscopy (SEM), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS) techniques were used for the material characterization and the obtained results are in good agreement. The selective determination of dopamine was demonstrated by cyclic voltammetry (CV) and amperometric experiments. The amperometric response was linear for dopamine concentrations between 1.0 x 10(-3) and 8.0 mM with a sensitivity of 90.9 µA mM(-1) cm(-2). The proposed dopamine biosensor is very stable, selective over common interferents as glucose, uric acid and ascorbic acid, and also good reproducibility was observed for seven electrodes. Moreover, the dopamine sensor exhibited a fast response time of less than 10 s. The wide range and acceptable sensitivity of the presented dopamine sensor provide the possible application in analysing the dopamine from the real samples.


Assuntos
Cobre/química , Dopamina/análise , Técnicas Eletroquímicas/instrumentação , Nanocompostos/química , Óxido de Zinco/química , Técnicas Eletroquímicas/métodos , Eletrodos , Vidro , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Am J Transplant ; 13(2): 312-9, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23279640

RESUMO

Calcineurin inhibitors (CNI) and steroids are known to promote insulin resistance, and their avoidance after islet transplantation is preferred from a metabolic standpoint. Belatacept, a B7-specific mediator of costimulation blockade (CoB), is clinically indicated as a CNI alternative in renal transplantation, and we have endeavored to develop a clinically translatable, belatacept-based regimen that could obviate the need for both CNIs and steroids. Based on the known synergy between CoB and mTOR inhibition, we studied rhesus monkeys undergoing MHC-mismatched islet allotransplants treated with belatacept and the mTOR inhibitor, sirolimus. To extend prior work on CoB-resistant rejection, some animals also received CD2 blockade with alefacept (LFA3-Ig). Nine rhesus macaques were rendered diabetic with streptozotocin and underwent islet allotransplantation. All received belatacept and sirolimus; six also received alefacept. Belatacept and sirolimus significantly prolonged rejection-free graft survival (median 225 days compared to 8 days in controls receiving basiliximab and sirolimus; p = 0.022). The addition of alefacept provided no additional survival benefit, but was associated with Cytomegalovirus reactivation in four of six animals. No recipients produced donor-specific alloantibodies. The combination of belatacept and sirolimus successfully prevents islet allograft survival in rhesus monkeys, but induction with alefacept provides no survival benefit and increases the risk of viral reactivation.


Assuntos
Imunoconjugados/administração & dosagem , Transplante das Ilhotas Pancreáticas/métodos , Proteínas Recombinantes de Fusão/administração & dosagem , Sirolimo/administração & dosagem , Transplante Homólogo/métodos , Abatacepte , Alefacept , Animais , Anticorpos Monoclonais/administração & dosagem , Basiliximab , Peptídeo C/metabolismo , Diabetes Mellitus Experimental , Sobrevivência de Enxerto , Antígenos de Histocompatibilidade/imunologia , Imunossupressores/administração & dosagem , Ilhotas Pancreáticas/efeitos dos fármacos , Ilhotas Pancreáticas/imunologia , Macaca mulatta , Esteroides/administração & dosagem
5.
Am J Transplant ; 12(7): 1918-23, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22458552

RESUMO

Islet transplantation to treat type 1 diabetes has been limited in part by toxicities of current immunosuppression and recipient humoral sensitization. Blockade of the CD28/CD80/86 and CD40/CD154 pathways has shown promise to remedy both these limitations, but translation has been hampered by difficulties in translating CD154-directed therapies. Prior CD40-directed regimens have led to prolonged islet survival, but fail to prevent humoral allosensitization. We therefore evaluated the addition of CTLA4Ig to a CD40 blockade-based regimen in nonhuman primate (NHP) alloislet transplantation. Diabetic rhesus macaques were transplanted allogeneic islets using the CD40-specific antibody 3A8, basiliximab induction, and sirolimus with or without CTLA4Ig maintenance therapy. Allograft survival was determined by fasting blood glucose levels and flow cytometric techniques were used to test for donor-specific antibody (DSA) formation. CTLA4Ig plus 3A8, basiliximab and sirolimus was well tolerated and induced long-term islet allograft survival. The addition of CTLA4Ig prevented DSA formation, but did not facilitate withdrawal of the 3A8-based regimen. Thus, CTLA4Ig combines with a CD40-specific regimen to prevent DSA formation in NHPs, and offers a potentially translatable calcineurin inhibitor-free protocol inclusive of a single investigational agent for use in clinical islet transplantation without relying upon CD154 blockade.


Assuntos
Anticorpos Monoclonais/imunologia , Antígenos CD40/imunologia , Imunoconjugados/imunologia , Transplante das Ilhotas Pancreáticas , Isoanticorpos/biossíntese , Abatacepte , Animais , Sobrevivência de Enxerto/imunologia , Macaca mulatta
6.
Am J Transplant ; 12(1): 126-35, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21920020

RESUMO

Costimulation blockade of the CD40/CD154 pathway has been effective at preventing allograft rejection in numerous transplantation models. This strategy has largely depended on mAbs directed against CD154, limiting the potential for translation due to its association with thromboembolic events. Though targeting CD40 as an alternative to CD154 has been successful at preventing allograft rejection in preclinical models, there have been no reports on the effects of CD40-specific agents in human transplant recipients. This delay in clinical translation may in part be explained by the presence of cellular depletion with many CD40-specific mAbs. As such, the optimal biologic properties of CD40-directed immunotherapy remain to be determined. In this report, we have characterized 3A8, a human CD40-specific mAb and evaluated its efficacy in a rhesus macaque model of islet cell transplantation. Despite partially agonistic properties and the inability to block CD40 binding of soluble CD154 (sCD154) in vitro, 3A8-based therapy markedly prolonged islet allograft survival without depleting B cells. Our results indicate that the allograft-protective effects of CD40-directed costimulation blockade do not require sCD154 blockade, complete antagonism or cellular depletion, and serve to support and guide the continued development of CD40-specific agents for clinical translation.


Assuntos
Anticorpos Monoclonais/uso terapêutico , Antígenos CD40/antagonistas & inibidores , Ligante de CD40/imunologia , Sobrevivência de Enxerto/imunologia , Transplante das Ilhotas Pancreáticas , Animais , Anticorpos Monoclonais/imunologia , Antígenos CD40/imunologia , Citometria de Fluxo , Imunoterapia , Teste de Cultura Mista de Linfócitos , Macaca mulatta , Modelos Animais
7.
Am J Transplant ; 11(3): 613-8, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21342450

RESUMO

Sirolimus is a potent antiproliferative agent used clinically to prevent renal allograft rejection. However, little is known about the effects of maintenance immunosuppressive agents on the immune response to potentially protective vaccines. Here we show that sirolimus paradoxically increases the magnitude and quality of the CD8+ T-cell response to vaccinia vaccination in nonhuman primates, fostering more robust recall responses compared to untreated and tacrolimus-treated controls. Enhancement of both the central and effector memory compartments of the vaccinia-specific CD8+ T-cell response was observed. These data elucidate new mechanistic characteristics of sirolimus and suggest immune applications extending beyond its role as an immunosuppressant.


Assuntos
Linfócitos T CD8-Positivos/efeitos dos fármacos , Linfócitos T CD8-Positivos/imunologia , Memória Imunológica/imunologia , Sirolimo/uso terapêutico , Vacínia/prevenção & controle , Vacinas Virais/uso terapêutico , Animais , Linfócitos T CD8-Positivos/virologia , Citocinas/metabolismo , Citometria de Fluxo , Memória Imunológica/efeitos dos fármacos , Imunossupressores/imunologia , Imunossupressores/uso terapêutico , Macaca mulatta , Sirolimo/imunologia , Vacinação , Vacínia/imunologia , Vacínia/virologia , Vaccinia virus/imunologia , Vacinas Virais/imunologia
8.
Biosens Bioelectron ; 99: 464-470, 2018 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-28820988

RESUMO

Bioluminescence has been widely used for important biosensing applications such as the measurement of adenosine triphosphate (ATP), the energy unit in biological systems and an indicator of vital processes. The current technology for detection is mainly based on large equipment such as readers and imaging systems, which require intensive and time-consuming procedures. A miniaturised bioluminescence sensing system, which would allow sensitive and continuous monitoring of ATP, with an integrated and low-cost disposable microfluidic chamber for handling of biological samples, is highly desirable. Here, we report the design, fabrication and testing of 3D printed microfluidics chips coupled with silicon photomultipliers (SiPMs) for high sensitive real-time ATP detection. The 3D microfluidic chip reduces reactant consumption and facilitates solution delivery close to the SiPM to increase the detection efficiency. Our system detects ATP with a limit of detection (LoD) of 8nM and an analytical dynamic range between 15nM and 1µM, showing a stability error of 3%, and a reproducibility error below of 20%. We demonstrate the dynamic monitoring of ATP in a continuous-flow system exhibiting a fast response time, ~4s, and a full recovery to the baseline level within 17s. Moreover, the SiPM-based bioluminescence sensing system shows a similar analytical dynamic range for ATP detection to that of a full-size PerkinElmer laboratory luminescence reader.


Assuntos
Trifosfato de Adenosina/isolamento & purificação , Técnicas Biossensoriais , Técnicas Analíticas Microfluídicas/métodos , Trifosfato de Adenosina/química , Dispositivos Lab-On-A-Chip , Medições Luminescentes , Impressão , Silício/química
9.
J Appl Physiol (1985) ; 103(3): 812-22, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17540836

RESUMO

A recent bout of high-intensity exercise can alter the balance of aerobic and anaerobic energy provision during subsequent exercise above the lactate threshold (theta(L)). However, it remains uncertain whether such "priming" influences the tolerable duration of subsequent exercise through changes in the parameters of aerobic function [e.g., theta(L), maximum oxygen uptake (Vo(2max))] and/or the hyperbolic power-duration (P-t) relationship [critical power (CP) and the curvature constant (W')]. We therefore studied six men performing cycle ergometry to the limit of tolerance; gas exchange was measured breath-by-breath and arterialized capillary blood [lactate] was measured at designated intervals. On different days, each subject completed 1) an incremental test (15 W/min) for estimation of theta(L) and measurement of the functional gain (DeltaVo(2)/DeltaWR) and Vo(2peak) and 2) four constant-load tests at different work rates (WR) for estimation of CP, W', and Vo(2max). All tests were subsequently repeated with a preceding 6-min supra-CP priming bout and an intervening 2-min 20-W recovery. The hyperbolicity of the P-t relationship was retained postpriming, with no significant difference in CP (241 +/- 39 vs. 242 +/- 36 W, post- vs. prepriming), Vo(2max) (3.97 +/- 0.34 vs. 3.93 +/- 0.38 l/min), DeltaVo(2)/DeltaWR (10.7 +/- 0.3 vs. 11.1 +/- 0.4 ml.min(-1).W(-1)), or the fundamental Vo(2) time constant (25.6 +/- 3.5 vs. 28.3 +/- 5.4 s). W' (10.61 +/- 2.07 vs. 16.13 +/- 2.33 kJ) and the tolerable duration of supra-CP exercise (-33 +/- 11%) were each significantly reduced, despite a less-prominent Vo(2) slow component. These results suggest that, following supra-CP priming, there is either a reduced depletable energy resource or a residual fatigue-metabolite level that leads to the tolerable limit before this resource is fully depleted.


Assuntos
Tolerância ao Exercício/fisiologia , Exercício Físico/fisiologia , Ventilação Pulmonar/fisiologia , Adolescente , Adulto , Teste de Esforço , Humanos , Masculino
10.
Biosens Bioelectron ; 22(6): 1131-7, 2007 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-16891110

RESUMO

Molecular imprinting has proved to be an effective technique for the creation of recognition sites on a polymer scaffold. Protein imprinting has been a focus for many chemists working in the area of molecular recognition, since the creation of synthetic polymers that can specifically recognise proteins is a very challenging but potentially extremely rewarding objective. It is expected that molecularly imprinted polymers (MIPs) with specificity for proteins will find application in medicine, diagnostics, proteomics, environmental analysis, sensors and drug delivery. In this review, the authors provide an overview of the progress achieved in the decade between 1994 and 2005, with respect to the challenging area of MIPs for protein recognition. The discussion furnishes a comparative analysis of different approaches developed, underlining their relative advantages and disadvantages and highlighting trends and possible future directions.


Assuntos
Técnicas Biossensoriais/métodos , Cristalização/métodos , Nanoestruturas/química , Polímeros/química , Análise Serial de Proteínas/métodos , Proteínas/análise , Proteínas/química , Adsorção , Nanoestruturas/ultraestrutura , Ligação Proteica , Mapeamento de Interação de Proteínas/métodos , Proteínas/ultraestrutura , Propriedades de Superfície
11.
Biosens Bioelectron ; 77: 505-11, 2016 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-26457736

RESUMO

The use of a novel ammonium ion-specific copper-polyaniline nano-composite as transducer for hydrolase-based biosensors is proposed. In this work, a combination of creatinine deaminase and urease has been chosen as a model system to demonstrate the construction of urea and creatinine biosensors to illustrate the principle. Immobilisation of enzymes was shown to be a crucial step in the development of the biosensors; the use of glycerol and lactitol as stabilisers resulted in a significant improvement, especially in the case of the creatinine, of the operational stability of the biosensors (from few hours to at least 3 days). The developed biosensors exhibited high selectivity towards creatinine and urea. The sensitivity was found to be 85 ± 3.4 mAM(-1)cm(-2) for the creatinine biosensor and 112 ± 3.36 mAM(-1)cm(-2) for the urea biosensor, with apparent Michaelis-Menten constants (KM,app), obtained from the creatinine and urea calibration curves, of 0.163 mM for creatinine deaminase and 0.139 mM for urease, respectively. The biosensors responded linearly over the concentration range 1-125 µM, with a limit of detection of 0.5 µM and a response time of 15s. The performance of the biosensors in a real sample matrix, serum, was evaluated and a good correlation with standard spectrophotometric clinical laboratory techniques was found.


Assuntos
Compostos de Amônio/química , Compostos de Anilina/química , Condutometria/instrumentação , Creatinina/sangue , Nanocompostos/química , Ureia/sangue , Aminoidrolases/química , Biomarcadores/sangue , Técnicas Biossensoriais/instrumentação , Cobre/química , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Íons , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Urease/química
12.
Biosens Bioelectron ; 80: 194-200, 2016 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-26836649

RESUMO

The Gram-negative bacterium, Salmonella Typhimurium (S. Typhimurium) is a food borne pathogen responsible for numerous hospitalisations and deaths all over the world. Conventional detection methods for pathogens are time consuming and labour-intensive. Hence, there is considerable interest in faster and simpler detection methods. Polypyrrole-based polymers, due to their intrinsic chemical and electrical properties, have been demonstrated to be valuable candidates for the fabrication of chemo/biosensors and functional surfaces. Similarly aptamers have been shown to be good alternatives to antibodies in the development of affinity biosensors. In this study, we report on the combination of poly [pyrrole-co-3-carboxyl-pyrrole] copolymer and aptamer for the development of a label-less electrochemical biosensor suitable for the detection of S. Typhimurium. Impedimetric measurements were facilitated by the effect of the aptamer/target interaction on the intrinsic conjugation of the poly [pyrrole-co-3-carboxyl-pyrrole] copolymer and subsequently on its electrical properties. The aptasensor detected S. Typhimurium in the concentration range 10(2)-10(8) CFU mL(-1) with high selectivity over other model pathogens and with a limit of quantification (LOQ) of 100 CFU mL(-1) and a limit of detection (LOD) of 3 CFU mL(-1). The suitability of the aptasensor for real sample detection was demonstrated via recovery studies performed in spiked apple juice samples. We envisage this to be a viable approach for the inexpensive and rapid detection of pathogens in food, and possibly in other environmental samples.


Assuntos
Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais , Salmonella typhimurium/isolamento & purificação , Microbiologia de Alimentos , Limite de Detecção , Polímeros/química , Pirróis/química , Salmonella typhimurium/patogenicidade
13.
Biosens Bioelectron ; 20(10): 1939-45, 2005 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-15741061

RESUMO

A DNA-based surface plasmon resonance (SPR) biosensor has been developed for the detection of TP53 mutation using the inexpensive and commercially available instrument, SPREETA SPR-EVM-BT, from Texas Instruments. A direct immobilisation procedure, based on the coupling of thiol-derivatised oligonucleotide probes (Probe-C6-SH) to bare gold sensor surfaces, was optimized using synthetic oligonucleotides. Hybridisation reactions between the immobilised probe and a short sequence (26 mer) complementary, non-complementary and one-point mutation DNA were then investigated. The main analytical parameters of the sensor system were studied in detail including selectivity, sensitivity, reproducibility and analysis time. Finally, the sensor system was successfully applied to polymerase chain reaction (PCR)-amplified real samples, DNA extracted from both normal, wild-type, (Jurkat) and mutated (Molt 4), carrying the mutation at codon 248 of the TP53 cell lines. The results obtained demonstrate that the DNA-based SPR biosensor was able to distinguish sequences present in the various samples that differ only by one base; and hence, it appears to be a strong candidate technique for the detection of gene mutation.


Assuntos
Técnicas Biossensoriais/instrumentação , Análise Mutacional de DNA/instrumentação , DNA/análise , DNA/genética , Hibridização In Situ/instrumentação , Análise de Sequência de DNA/instrumentação , Ressonância de Plasmônio de Superfície/instrumentação , Proteína Supressora de Tumor p53/análise , Proteína Supressora de Tumor p53/genética , Técnicas Biossensoriais/métodos , Análise Mutacional de DNA/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Hibridização In Situ/métodos , Células Jurkat , Miniaturização , Análise de Sequência de DNA/métodos , Ressonância de Plasmônio de Superfície/métodos
14.
Biosens Bioelectron ; 20(11): 2310-3, 2005 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-15797331

RESUMO

The TP53 gene has been the subject of intense research since the realisation that inactivation of this gene is common to most cancer types. Numerous publications have linked TP53 mutations in general or at specific locations to patient prognosis and therapy response. The findings of many studies using general approaches such as immunohistochemistry or sequencing are contradictory. However, the detection of specific mutations, especially those occurring in the structurally important L2 and L3 zinc binding domains, which are the most common sites of TP53 mutations, have been linked to patient prognosis and more strongly to radiotherapy and chemotherapy resistance in several major cancers. In this study, the TI-SPR-1 surface plasmon resonance system and Texas Instruments Spreeta chips were used to develop a DNA biosensor based on thiolated probes complementary to these domains. The sensors were able to detect these mutations in both oligonucleotides and PCR products with normal and mutant TP53 DNA, but the difference in hybridisation signal was small. Preliminary experiments to enhance the signal using Escherichia coli mismatch repair proteins, MutS and single strand binding protein were carried out. It was found that MutS was unable to bind to mismatch oligonucleotides, but single strand binding protein was able to bind to single stranded probes, which had not hybridised to the target, resulting in a three-fold increase in the sensitivity of the biosensor. While further work needs to be carried out to optimise the system, these preliminary experiments indicate that the TI-SPR-1 can be used for the detection of clinically relevant mutations in the TP53 gene and that the sensitivity can be increased significantly using single strand binding protein. This system has a number of advantages over current mutation detection technologies, including lower cost, ease of sensor preparation and measurement procedures, technical simplicity and increased speed due to the lack of need for gel electrophoresis.


Assuntos
Técnicas Biossensoriais/instrumentação , Análise Mutacional de DNA/instrumentação , Análise de Sequência com Séries de Oligonucleotídeos/instrumentação , Óptica e Fotônica/instrumentação , Polimorfismo de Nucleotídeo Único/genética , Proteína Supressora de Tumor p53/genética , Análise Mutacional de DNA/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Testes Genéticos/métodos , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Integração de Sistemas
15.
Curr Opin Biotechnol ; 5(1): 49-53, 1994 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-7764643

RESUMO

Advances in biosensor technology over the past year have included developments in metalized electrodes, mediated electrochemistry, direct electron transfer, impedance measurement, optical immunosensors, optodes, biomimicry, piezoelectric biosensors, enzyme thermistors, in vivo biosensors, surface characterization, organic-phase biosensors and tissue-based biosensors. Increasingly, molecular biology and engineering are being used in sensor design.


Assuntos
Técnicas Biossensoriais , Engenharia Biomédica , Biotecnologia , Impedância Elétrica , Eletroquímica , Eletrodos , Transporte de Elétrons , Metais , Óptica e Fotônica , Temperatura
16.
Br J Health Psychol ; 10(Pt 4): 589-99, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16238867

RESUMO

OBJECTIVE: A previous study reported some improved outcomes at 4-month follow-up after attendance on a lay-led, chronic disease self-management course (CDSMC). The purpose of this study was to determine whether changes were maintained over time (i.e. at 12 months) and to describe participants' current use of self-management techniques. DESIGN: The study was a 12-month follow-up of a sample of 171 participants who attended a CDSMC in the UK. METHOD: Data were collected by self-administered questionnaires mailed to participants 12 months after they commenced a CDSMC and via telephone interviews with a sub-sample. RESULTS: The sample had a mean age of 54 years, mean disease duration of 16 years, 73% were women, and chronic diseases included endometriosis, depression, diabetes, myalgic encephalomyelitis, osteoporosis and polio. The significant improvements in outcomes identified at 4 months (i.e. cognitive symptom management, self-efficacy, communication with physician, fatigue, anxious and depressed moods and health distress) were sustained at 12 months. No significant changes between 4- and 12-month assessments were found on any study variables. Interview data confirmed that participants continued to use some of the self-management techniques learned on the course. CONCLUSION: Attendance on the CDSMC may lead to longer-term changes in key outcomes such as self-efficacy, use of some self-management behaviours and some aspects of health status (e.g. fatigue, depressed mood).


Assuntos
Doença Crônica/reabilitação , Educação de Pacientes como Assunto , Autocuidado/psicologia , Atividades Cotidianas/classificação , Atividades Cotidianas/psicologia , Adaptação Psicológica , Adulto , Idoso , Doença Crônica/psicologia , Feminino , Seguimentos , Processos Grupais , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida/psicologia , Autoeficácia , Papel do Doente , Inquéritos e Questionários
17.
Trends Biotechnol ; 19(1): 9-12, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11146096

RESUMO

Molecularly imprinted polymers (MIPs) represent a new class of materials that have artificially created receptor structures (1-3). Since their discovery in 1972, MIPs have attracted considerable interest from scientists and engineers involved with the development of chromatographic adsorbents, membranes, sensors and enzyme and receptor mimics.


Assuntos
Biotecnologia/tendências , Impressão Genômica , Biologia Molecular/tendências , Polímeros/química , Polímeros/isolamento & purificação , Fatores de Tempo
18.
J Immunol Methods ; 112(2): 153-61, 1988 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-3047261

RESUMO

Enzyme-amplified immunoassays have been adapted for electrochemical measurement, using an NAD+/NADH redox cycle coupled to an electrode via the active site of diaphorase. Two amperometric methods are described, the first employs an organic conducting salt electrode, NMP+/TCNQ-; the second a platinum wire with ferricyanide as electron transfer mediator. In an immunoenzymometric assay for human prostatic acid phosphatase the sensitivities of the electrochemical methods were comparable to that achieved with the existing optical technique, but the dynamic range of the electrochemical assays was increased by at least two orders of magnitude. It is proposed that electrochemical enzyme-amplified immunoassays may eventually replace their optical counterparts.


Assuntos
Eletroquímica , Técnicas Imunoenzimáticas , Fosfatase Ácida/análise , Eletrodos , Masculino , NAD/análise , Próstata/enzimologia
19.
Biotechnol Adv ; 13(1): 1-12, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-14537143

RESUMO

Increasing environmental legislation which controls the release and the levels of certain chemicals in the environment has created a need for reliable monitoring of these substances in air, soil and especially water. Conventional analytical techniques, although highly precise, suffer from the disadvantages of high cost, the need for trained personnel and the fact that they are mostly laboratory bound. Biosensors because of their specificity, fast response times, low cost, portability, ease of use and a continuous real time signal, can present distinct advantages in certain cases. Their biological base makes them ideal for toxicological measurements which are suited for health and safety applications. Over the last 3-4 years there has been an increase in the number of publications concerning biosensors for environmental monitoring, especially in the field of pesticide measurements. This paper reviews some of the more important developments over the past 3-4 years.

20.
Biomaterials ; 9(1): 66-70, 1988 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-3280040

RESUMO

There is a growing demand for the production of a DNA biosensor with applications in medicine, the food industry, agriculture, veterinary science and environmental science. In this paper we describe methods for the optical and electrochemical detection of DNA using the enzyme horseradish peroxidase (EC 1.11.1.7) and glucose oxidase (EC 1.1.3.4). We have used bis-methylacridinium nitrate and luminol for the optical detection of DNA using a purpose built, inexpensive luminometer. Using this system detection limits of 10(-11) g of plasmid DNA have been observed. Electrochemical detection of DNA was carried out by the use of a fluoride ion selective electrode and stripping voltammetry. DNA was detected down to 10(-9)-10(-10) g of DNA by the enzymatic release of halogen ions from organohalogen compounds.


Assuntos
DNA/análise , Eletroquímica , Óptica e Fotônica , Animais , Glucose Oxidase , Peroxidase do Rábano Silvestre , Óptica e Fotônica/instrumentação , Potenciometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA