Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Am J Otolaryngol ; 42(4): 102970, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33667797

RESUMO

INTRODUCTION: The highly contagious COVID-19 has resulted in millions of deaths worldwide. Physicians performing orbital procedures may be at increased risk of occupational exposure to the virus due to exposure to secretions. The goal of this study is to measure the droplet and aerosol production during repair of the inferior orbital rim and trial a smoke-evacuating electrocautery handpiece as a mitigation device. MATERIAL AND METHODS: The inferior rim of 6 cadaveric orbits was approached transconjunctivally using either standard or smoke-evacuator electrocautery and plated using a high-speed drill. Following fluorescein inoculation, droplet generation was measured by counting under ultraviolet-A (UV-A) light against a blue background. Aerosol generation from 0.300-10.000 µm was measured using an optical particle sizer. Droplet and aerosol generation was compared against retraction of the orbital soft tissue as a negative control. RESULTS: No droplets were observed following the orbital approach using electrocautery. Visible droplets were observed after plating with a high-speed drill for 3 of 6 orbits. Total aerosol generation was significantly higher than negative control following the use of standard electrocautery. Use of smoke-evacuator electrocautery was associated with significantly lower aerosol generation in 2 of 3 size groups and in total. There was no significant increase in total aerosols associated with high-speed drilling. DISCUSSION AND CONCLUSIONS: Droplet generation for orbital repair was present only following plating with high-speed drill. Aerosol generation during standard electrocautery was significantly reduced using a smoke-evacuating electrocautery handpiece. Aerosols were not significantly increased by high-speed drilling.


Assuntos
COVID-19/transmissão , Eletrocoagulação/efeitos adversos , Transmissão de Doença Infecciosa do Paciente para o Profissional , Exposição Ocupacional/efeitos adversos , Órbita/cirurgia , SARS-CoV-2/patogenicidade , Aerossóis , COVID-19/prevenção & controle , Cadáver , Humanos , Medição de Risco
2.
J Pediatr Ophthalmol Strabismus ; : 1-4, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38482801

RESUMO

PURPOSE: To compare a single surgeon's surgical outcomes for treating intermittent exotropia using bilateral lateral rectus recession (BLR), unilateral lateral rectus recession and medial rectus resection (RR), and unilateral lateral rectus recession and medial rectus plication (RP). METHODS: A retrospective review of all surgeries for basic intermittent exotropia between 2015 and 2023 was performed. Only patients with initial correction using BLR, RR, or RP were included. Exclusion criteria included age older than 18 years, vertical deviation, any nonrefractive ocular diagnoses, prior ocular surgery, and inadequate follow-up. RESULTS: There were 460 patients identified; 123 met inclusion criteria with 54 in the BLR group, 41 in the RR group, and 28 in the RP group. The average preoperative distance alignment (and standard error) values for the BLR, RR, and RP groups were 25.07 (7.35), 22.44 (5.95), and 23.84 (6.42) prism diopters (PD), respectively. At 1 year, the postoperative distance alignment values for the BLR, RR, and RP groups were 8.72 (7.89), 7.46 (6.31), and 12.83 (6.82) PD, respectively (P = .03). A subanalysis found a significant difference between the BLR and RP (P = .02) and RR and RP (P = .02) groups. There was no difference between the BLR and RR groups (P = .57). CONCLUSIONS: This study of three surgical approaches for intermittent exotropia found RP had a significantly larger angle of exodeviation compared to BLR and RR at 1 year of follow-up. Both BLR and RR were equally effective approaches for treating intermittent exotropia. [J Pediatr Ophthalmol Strabismus. 20XX;XX(X):XX-XX.].

3.
Artigo em Inglês | MEDLINE | ID: mdl-34964656

RESUMO

Introduction: The coronavirus disease 2019 pandemic has led to concerns over transmission risk from head and neck operations including facial cosmetic surgeries. Objectives: To quantify droplet and aerosol generation from rhinoplasty techniques in a human anatomic specimen model using fluorescein staining and an optical particle sizer. Methods: Noses of human anatomic specimens were infiltrated using 0.1% fluorescein. Droplets and aerosols were measured during rhinoplasty techniques including opening the skin-soft tissue envelope, monopolar electrocautery, endonasal rasping, endonasal osteotomy, and percutaneous osteotomy. Results: No visible droplet contamination was observed for any rhinoplasty techniques investigated. Compared with the negative control of anterior rhinoscopy, total 0.300-10.000 µm aerosols were increased after monopolar electrocautery (p < 0.001) and endonasal rasp (p = 0.003). Opening the skin-soft tissue envelope, endonasal osteotomies, and percutaneous osteotomies did not generate a detectable increase in aerosols (p > 0.15). Discussion and Conclusions: In this investigation, droplets were not observed under ultraviolet light, and aerosol generation was noted only with cautery and endonasal rasping.

4.
Digit J Ophthalmol ; 25(4): 59-64, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32076389

RESUMO

A 4-year-old girl with a history of Pearson marrow-pancreas syndrome presenting with severe, progressive photophobia was found to have bilateral, diffuse corneal thickening and peripheral pigmentary retinopathy. She underwent Descemet stripping automated endothelial keratoplasty (DSAEK) surgery in both eyes using a modified suture pull-through technique. Postoperatively there was no evidence of cataract formation or graft detachment; her corneas thinned, and her photophobia improved dramatically.


Assuntos
Doenças da Córnea/cirurgia , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/métodos , Endotélio Corneano/fisiopatologia , Fotofobia/cirurgia , Técnicas de Sutura/instrumentação , Suturas , Acuidade Visual , Acil-CoA Desidrogenase de Cadeia Longa/deficiência , Pré-Escolar , Síndrome Congênita de Insuficiência da Medula Óssea , Doenças da Córnea/complicações , Doenças da Córnea/fisiopatologia , Paquimetria Corneana/métodos , Endotélio Corneano/patologia , Feminino , Humanos , Erros Inatos do Metabolismo Lipídico , Doenças Mitocondriais , Doenças Musculares , Fotofobia/etiologia , Fotofobia/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA