Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Phys Rev Lett ; 120(20): 207601, 2018 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-29864371

RESUMO

Here, we photoinduce and directly observe with x-ray scattering an ultrafast enhancement of the structural long-range order in the archetypal Mott system V_{2}O_{3}. Despite the ultrafast increase in crystal symmetry, the change of unit cell volume occurs an order of magnitude slower and coincides with the insulator-to-metal transition. The decoupling between the two structural responses in the time domain highlights the existence of a transient photoinduced precursor phase, which is distinct from the two structural phases present in equilibrium. X-ray nanoscopy reveals that acoustic phonons trapped in nanoscale twin domains govern the dynamics of the ultrafast transition into the precursor phase, while nucleation and growth of metallic domains dictate the duration of the slower transition into the metallic phase. The enhancement of the long-range order before completion of the electronic transition demonstrates the critical role the nonequilibrium structural phases play during electronic phase transitions in correlated electrons systems.

2.
Nanoscale ; 13(9): 4985-4994, 2021 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-33634814

RESUMO

We investigate the local nanoscale changes of the magnetic anisotropy of a Ni film subject to an inverse magnetostrictive effect by proximity to a V2O3 layer. Using temperature-dependent photoemission electron microscopy (PEEM) combined with X-ray magnetic circular dichroism (XMCD), direct images of the Ni spin alignment across the first-order structural phase transition (SPT) of V2O3 were obtained. We find an abrupt temperature-driven reorientation of the Ni magnetic domains across the SPT, which is associated with a large increase of the coercive field. Moreover, angular dependent ferromagnetic resonance (FMR) shows a remarkable change in the magnetic anisotropy of the Ni film across the SPT of V2O3. Micromagnetic simulations based on these results are in quantitative agreement with the PEEM data. Direct measurements of the lateral correlation length of the Ni domains from XMCD images show an increase of almost one order of magnitude at the SPT compared to room temperature, as well as a broad spatial distribution of the local transition temperatures, thus corroborating the phase coexistence of Ni anisotropies caused by the V2O3 SPT. We show that the rearrangement of the Ni domains is due to strain induced by the oxide layers' structural domains across the SPT. Our results illustrate the use of alternative hybrid systems to manipulate magnetic domains at the nanoscale, which allows for engineering of coercive fields for novel data storage architectures.

3.
J Neurophysiol ; 104(3): 1803-11, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20610792

RESUMO

The on-line identification of labeled cells and vessels is a rate-limiting step in scanning microscopy. We use supervised learning to formulate an algorithm that rapidly and automatically tags fluorescently labeled somata in full-field images of cortex and constructs an optimized scan path through these cells. A single classifier works across multiple subjects, regions of the cortex of similar depth, and different magnification and contrast levels without the need to retrain the algorithm. Retraining only has to be performed when the morphological properties of the cells change significantly. In conjunction with two-photon laser scanning microscopy and bulk-labeling of cells in layers 2/3 of rat parietal cortex with a calcium indicator, we can automatically identify ∼ 50 cells within 1 min and sample them at ∼ 100 Hz with a signal-to-noise ratio of ∼ 10.


Assuntos
Corantes Fluorescentes/análise , Microscopia Confocal/métodos , Córtex Somatossensorial/química , Córtex Somatossensorial/citologia , Animais , Ratos , Ratos Sprague-Dawley , Córtex Somatossensorial/fisiologia , Fatores de Tempo
4.
Rev Sci Instrum ; 87(4): 043105, 2016 04.
Artigo em Inglês | MEDLINE | ID: mdl-27131652

RESUMO

Raman micro-spectroscopy is well suited for studying a variety of properties and has been applied to a wide range of areas. Combined with tuneable temperature, Raman spectra can offer even more insights into the properties of materials. However, previous designs of variable temperature Raman microscopes have made it extremely challenging to measure samples with low signal levels due to thermal and positional instabilities as well as low collection efficiencies. Thus contemporary Raman microscope has found limited applicability to probing the subtle physics involved in phase transitions and hysteresis. This paper describes a new design of a closed-cycle, Raman microscope with full polarization rotation. High collection efficiency, thermal stability, and mechanical stability are ensured by both deliberate optical, cryogenic, and mechanical design. Measurements on two samples, Bi2Se3 and V2O3, which are challenging due to low thermal conductivities, low signal levels, and/or hysteretic effects, are measured with previously undemonstrated temperature resolution.

5.
Rev Sci Instrum ; 85(3): 033701, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24689586

RESUMO

We present a software package called Microscopy Image Segmentation Tool (MIST). MIST is designed for analysis of microscopy images which contain large collections of small regions of interest (ROIs). Originally developed for analysis of porous anodic alumina scanning electron images, MIST capabilities have been expanded to allow use in a large variety of problems including analysis of biological tissue, inorganic and organic film grain structure, as well as nano- and meso-scopic structures. MIST provides a robust segmentation algorithm for the ROIs, includes many useful analysis capabilities, and is highly flexible allowing incorporation of specialized user developed analysis. We describe the unique advantages MIST has over existing analysis software. In addition, we present a number of diverse applications to scanning electron microscopy, atomic force microscopy, magnetic force microscopy, scanning tunneling microscopy, and fluorescent confocal laser scanning microscopy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA