Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Stroke ; 52(1): 344-347, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33272133

RESUMO

BACKGROUND AND PURPOSE: The purpose of this study was to assess nationwide incidence and outcomes of aneurysmal subarachnoid hemorrhage (aSAH). The Swiss SOS (Swiss Study on Subarachnoid Hemorrhage) was established in 2008 and offers the unique opportunity to provide this data from the point of care on a nationwide level. METHODS: All patients with confirmed aneurysmal subarachnoid hemorrhage admitted between January 1, 2009 and December 31, 2014, within Switzerland were recorded in a prospective registry. Incidence rates were calculated based on time-matched population data. Admission parameters and outcomes at discharge and at 1 year were recorded. RESULTS: We recorded data of 1787 consecutive patients. The incidence of aneurysmal subarachnoid hemorrhage in Switzerland was 3.7 per 100 000 persons/y. The number of female patients was 1170 (65.5%). With a follow-up rate of 91.3% at 1 year, 1042 patients (58.8%) led an independent life according to the modified Rankin Scale (0-2). About 1 in 10 patients survived in a dependent state (modified Rankin Scale, 3-5; n=185; 10.4%). Case fatality was 20.1% (n=356) at discharge and 22.1% (n=391) after 1 year. CONCLUSIONS: The current incidence of aneurysmal subarachnoid hemorrhage in Switzerland is lower than expected and an indication of a global trend toward decreasing admissions for ruptured intracranial aneurysms. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03245866.


Assuntos
Hemorragia Subaracnóidea/epidemiologia , Hemorragia Subaracnóidea/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma Roto/epidemiologia , Aneurisma Roto/mortalidade , Aneurisma Roto/terapia , Feminino , Seguimentos , Humanos , Incidência , Vida Independente , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Fatores Sexuais , Hemorragia Subaracnóidea/mortalidade , Análise de Sobrevida , Suíça/epidemiologia , Resultado do Tratamento
2.
World Neurosurg ; 182: e1-e4, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38097168

RESUMO

INTRODUCTION: In recent years, introduction of the exoscope system has been responsible for a new era of optics in surgery. Such a system has started to be widely used in neurosurgery. More recently, the exoscope has also been increasingly used for spinal procedures. Thus, we aimed to explore the potential for exoscope-assisted spinal procedures and define the advantages and drawbacks of implementing the system into our daily routine. METHODS: To achieve the aim of the study, we retrospectively reviewed the case series of patients treated by a senior surgeon and analyzed the results, complications, and operative time. The operating times were compared between the exoscope-assisted procedures and microscope-assisted procedures. RESULTS: A total of 24 spinal procedure were performed with the exoscope in a 2-month period. In this first patient series performed by a single surgeon without experience with the exoscope, the learning curve seemed to be relatively low, with mastery of the instrument achieved after the performance of only a few cases. Comparing the cases after the plateau of the learning curve had been reached with those performed during the still active phase of the learning curve, a significant difference was found in the operative times. No statistically significant difference was detected in terms of blood loss or intraoperative complications. CONCLUSIONS: Based on our first experience, use of the exoscope shows promising potential for opening up new frontiers in spinal microsurgery. In addition, it has a low learning curve for experienced surgeons.


Assuntos
Curva de Aprendizado , Procedimentos Neurocirúrgicos , Humanos , Estudos Retrospectivos , Procedimentos Neurocirúrgicos/métodos , Coluna Vertebral/cirurgia , Microscopia , Microcirurgia/métodos
3.
Interv Neuroradiol ; : 15910199231212519, 2023 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-37936414

RESUMO

BACKGROUND: Patients with acute ischemic stroke secondary to large vessel occlusions and good collaterals are frequently associated with favorable outcomes after mechanical thrombectomy, although poor outcomes are observed also in this subgroup. We aimed to investigate the factors associated with unfavorable outcomes (modified Rankin Scale3-6) in this specific subgroup of patients. METHODS: In total, 219 patients (117 females) with anterior circulation stroke and good collaterals (American Society for Interventional and Therapeutic Neuroradiology/Society of Interventional Radiology grades 3-4), treated by mechanical thrombectomy between 2016 and 2021 at our institution were included in this study. Clinical files and neuroimaging were retrospectively reviewed. Univariate and multivariate analyses were performed to identify the predictors of unfavorable outcomes in the overall population (primary endpoint). Secondary endpoints focused on the analysis of the predictors of unfavorable outcomes in the subgroup of successfully recanalized patients, mortality, and symptomatic intracerebral hemorrhages in the overall population. RESULTS: Poor outcome was observed in 47% of the patients despite the presence of good collaterals. Older age (p < 0.001), higher baseline National Institute of Health stroke scale (p < 0.001), no intravenous thrombolysis administration (p = 0.004), > 3 passes (p = 0.01), and secondary transfers (p < 0.001) were associated with the primary endpoint. The multivariate analysis showed a predictive effect of modified treatment in cerebral infarction 2b-3 and of first pass effect on symptomatic intracerebral hemorrhage. CONCLUSIONS: Despite good collaterals, defined through the American Society for Interventional and Therapeutic Neuroradiology/Society of Interventional Radiology scale, poor outcomes occurred in almost half of the patients. Patients with good collaterals not receiving intravenous thrombolysis were significantly associated with unfavorable outcomes, whereas first pass effect was not significantly correlated with clinical outcome in this specific cohort of patients. Different methods to assess collaterals should also be investigated.

4.
Front Oncol ; 12: 1067312, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36686774

RESUMO

Introduction: Effective strategies are required to ensure optimal management of the crucial closure step in endoscopic pituitary surgery. Many surgical techniques have been reported but no significant consensus has been defined. Methods: Between January 2006 and March 2022, 3015 adult patients with pituitary adenomas were operated on by a single expert neurosurgical team, using a mononostril endoscopic endonasal approach. Based of preoperative risk factors of and operative findings, a detailed closure strategy was used. Body mass index >40, sellar floor lysis, number of surgeries>2, large skull base destruction, prior radiotherapy were considered as preoperative risk factors for closure failure. All patients treated with an expanded endonasal approach were excluded. Results: Patients were mostly women (F/M ratio: 1.4) with a median age of 50 (range: 18 -89). Intraoperative CSF leak requiring specific surgical management was observed in 319/3015 (10.6%) of patients. If intraoperative leak occurred, patients with predictive risk factors were managed using a Foley balloon catheter in case of sellar floor lysis or BMI>40 and a multilayer repair strategy with a vascularized nasoseptal flap in other cases. Postoperative CSF leak occurred in 29/3015 (1%) of patients, while meningitis occurred in 24/3015 (0.8%) of patients. In patients with intraoperative leak, closure management failed in 11/319 (3.4%) of cases. Conclusion: Based on our significant 16-year experience, our surgical management is reliable and easy to follow. With a planned and stepwise strategy, the closure step can be optimized and tailored to each patient with a very low failure rate.

5.
World Neurosurg ; 148: e572-e580, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33482416

RESUMO

OBJECTIVE: To provide data about surgical workflow, accuracy, complications, radiation exposure, and learning curve effect in patients who underwent minimally invasive (MIS) transforaminal lumbar interbody fusion with navigation coupled with mobile intraoperative computed tomography. METHODS: A retrospective analysis was performed of data from consecutive patients who underwent single- or double-level MIS transforaminal lumbar interbody fusion at a single institution; mobile intraoperative computed tomography combined with a navigation system was used as the sole intraoperative imaging method to place pedicular screws; decompression and interbody fusion were performed through a 22-mm tubular retractor. Clinical data, perioperative complications, accuracy of pedicular screw placement, and radiation exposure were analyzed. A learning curve effect on surgical time and accuracy was assessed. RESULTS: A total of 408 screws in 100 patients were analyzed. In all cases, spinal navigation allowed for identification of pedicular trajectories and greatly facilitated nerve root decompression through the MIS approach. Overall accuracy according to Heary classification was 95.3%. Nineteen screws (4.7%) presented a minor lateral breach (<2 mm), not clinically significant. Surgical time, blood loss, and patient radiation exposure compared favorably with reported values from other series using three-dimensional navigation. A learning curve effect on surgical time, but not on screw accuracy, was identified. CONCLUSIONS: MIS transforaminal lumbar interbody fusion can now be performed without any radiation exposure to the surgeon and operating room staff, with almost absolute accuracy during screw positioning and tubular decompression. A learning curve effect on surgical time, but not on overall screw accuracy, may be expected.


Assuntos
Vértebras Lombares/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Monitorização Intraoperatória , Fusão Vertebral/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Perda Sanguínea Cirúrgica , Estudos de Coortes , Terapia Combinada , Descompressão Cirúrgica , Feminino , Humanos , Imageamento Tridimensional , Curva de Aprendizado , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Parafusos Pediculares , Estudos Retrospectivos , Raízes Nervosas Espinhais/cirurgia , Resultado do Tratamento
7.
World Neurosurg ; 88: 297-299, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26455768

RESUMO

BACKGROUND: Exposure to magnetic fields may alter the settings of programmable ventriculoperitoneal shunt valves or even cause permanent damages to these devices. There is little information about this topic, none on live patients. OBJECTIVE: To investigate the effects of 1.5-tesla magnetic resonance imaging (MRI) on Hakim-Codman (HC) pressure programmable valves implanted in our hospital. METHODS: A single-center prospective study to assess the rate of perturbations of HC programmable valve implanted. One hundred consecutive patients implanted for different clinical reasons between 2008 and 2012 were examined. A conventional skull x-ray before and after a standard MRI on 1.5 tesla. We evaluated before and after results, analyzed modification rate, and verified eventual damages to the implanted devices. RESULTS: Implanted HC valves are extremely handy and durable, even if they are likely to change often due to the exposure to magnetic fields. None of the patients complained of heating effects. Oscillations range from 10-30 mm H2O with a patient who reached 50 mm H2O and 1 who reached 60 mm H2O. Global alteration rate was 40%: 10 patients (10%) experienced a 10 mm H2O change; 14 patients (14%) had a 20 mm H2O change; 6 patients (6%) had a 30 mm H2O change; 8 patients (8%) had a 40 mm H2O change; 1 patient had a 50 mm H2O change; and 1 patient had a 60 mm H2O change. CONCLUSIONS: HC valves presented a variable perturbation rate, with an alteration rate of 40% with 1.5-telsa MRI. We have not observed malfunctioning hardware as a result of magnetic influence. We claim ​ a cranial x-ray immediately after the MRI because of a high risk (40%) of decalibration, especially in patients with low ventricles compliance.


Assuntos
Falha de Equipamento/estatística & dados numéricos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/estatística & dados numéricos , Terapia Assistida por Computador/estatística & dados numéricos , Derivação Ventriculoperitoneal/instrumentação , Derivação Ventriculoperitoneal/estatística & dados numéricos , Contraindicações , Desenho de Equipamento , Análise de Falha de Equipamento/estatística & dados numéricos , Humanos , Itália/epidemiologia , Terapia Assistida por Computador/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA