Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Radiology ; 249(3): 1002-9, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18941159

RESUMO

PURPOSE: To compare radiation exposure and effective dose in children who underwent voiding cystourethrography (VCUG) performed with grid-controlled variable-rate pulsed fluoroscopy (GCPFL) with radiation exposure and effective dose in children who underwent VCUG performed with continuous fluoroscopy (CFL) and to compare these effective doses with those estimated with radionuclide cystography (RNC). MATERIALS AND METHODS: Institutional review board approval was obtained, and the informed consent requirement was waived for this HIPAA-compliant retrospective study. Radiation exposure and fluoroscopy time during VCUG were reviewed in 145 children (75 girls, 70 boys; age range, 3 days to 8 years) who underwent GCPFL or CFL between 2001 and 2002. Children were grouped on the basis of the fluoroscopy unit used and their supine anteroposterior abdominal diameter (group 1, 8.0-8.5-cm diameter; group 2, 10-11-cm diameter; group 3, 12-13-cm diameter). Analysis of variance was used to compare radiation exposure and fluoroscopy time between fluoroscopy units and patient diameter groups. Effective doses were calculated and compared for both fluoroscopes and for estimated RNC dose values. RESULTS: GCPFL resulted in a significant reduction in total radiation exposure, which was at least eight times lower than that with CFL in all three groups (P < .001 for all). There was no significant difference in fluoroscopy time (P > .50). Effective radiation doses from GCPFL were approximately one order of magnitude lower than those from CFL but one order of magnitude higher than those from RNC. CONCLUSION: In children, VCUG can be performed with a GCPFL unit that delivers radiation exposures that are at least eight times lower than those delivered by a conventional CFL unit. SUPPLEMENTAL MATERIAL: http://radiology.rsnajnls.org/cgi/content/full/2492062066/DC1.


Assuntos
Doses de Radiação , Urografia/métodos , Criança , Pré-Escolar , Feminino , Fluoroscopia/métodos , Humanos , Lactente , Recém-Nascido , Masculino , Cintilografia , Estudos Retrospectivos , Bexiga Urinária/diagnóstico por imagem , Doenças Urológicas/diagnóstico por imagem
2.
Radiology ; 238(1): 96-106, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16373761

RESUMO

PURPOSE: To compare grid-controlled variable-rate pulsed fluoroscopy (GCPFL) and continuous fluoroscopy (CFL) for the reduction of radiation exposure during voiding cystourethrography (VCUG) in a pediatric porcine model of vesicoureteral reflux. MATERIALS AND METHODS: Institutional animal care and use committee approval was obtained. Vesicoureteral reflux was simulated in four pigs, and 48 VCUG studies were performed (24 with GCPFL, 24 with CFL). VCUG was performed at abdominal girths of 8-10 cm (group 1, simulates human newborn to 6-month-old infant), 12-13 cm (group 2, simulates 2-3-year-old child), and 15-17 cm (group 3, simulates 10-year-old child). An electronic device calculated total radiation exposure during fluoroscopy and image recording. With five-point ordinal scales, VCUG images were scored independently for anatomic conspicuity and overall diagnostic quality by two radiologists (radiologists A and B). An analysis of variance was used to compare radiation exposures and fluoroscopy times between GCPFL and CFL and to determine whether radiation exposure and fluoroscopy time were dependent on the pig's abdominal girth. The Pearson product-moment correlation coefficient was used to assess whether fluoroscopy time was correlated with radiation exposure. Anatomic conspicuity and diagnostic quality scores were compared by means of the Wilcoxon signed rank test. RESULTS: Results of analysis of variance revealed that GCPFL resulted in a significant reduction in total radiation exposure compared with CFL for each of the three groups (P < .05 for each comparison), and this reduction was most marked in the larger animals. There were no significant differences in diagnostic quality of the recorded VCUG images (P > .05). Anatomic conspicuity was not significantly different for groups 2 and 3, but there was a significantly higher score for GCPFL in group 1 for radiologist A (P = .04). CONCLUSION: By using GCPFL in the performance of VCUG in a pediatric porcine model of vesicoureteral reflux, total radiation exposure can be reduced by a factor of 4.6-7.5 lower than with CFL, and diagnostic-quality images can be obtained.


Assuntos
Fluoroscopia/instrumentação , Proteção Radiológica/métodos , Refluxo Vesicoureteral/diagnóstico por imagem , Análise de Variância , Animais , Meios de Contraste , Doses de Radiação , Intensificação de Imagem Radiográfica , Estatísticas não Paramétricas , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA