Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Life (Basel) ; 14(1)2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38255747

RESUMO

BACKGROUND: Safety, efficacy, and patient comfort are the expectations during pulmonary vein isolation (PVI). We aimed to validate the combined advantages of pre- and periprocedural anticoagulation with non-vitamin K anticoagulants (NOACs) and rigorous left atrial appendage thrombus (LAAT) exclusion with computed tomography (CT). METHODS: This study included a population of consecutive patients, between March 2018 and June 2020, who underwent cardiac CT within 24 h before PVI to guide the ablation and rule out LAAT. NOAC was omitted 24 h before the ablation. RESULTS: A total of 187 patients (63% male) underwent CT before PVI. None of the patients experienced stroke during or after the procedure. The complication rate was low, with no thromboembolic events and 2.1% of patients experiencing a major bleeding event. CONCLUSIONS: Omitting NOAC 24 h before the ablation might be safe if combined with left atrial thrombus exclusion with computed tomography.

2.
J Interv Card Electrophysiol ; 66(4): 847-855, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33723694

RESUMO

PURPOSE: The use of cardiac implantable electronic devices (CIEDs) has increased significantly over the last decades. With the development of transvenous lead extraction (TLE), procedural success rates also improved; however, data regarding long-term outcomes are still limited. The aim of our study was to analyze the outcomes after TLE, including reimplantation data, all-cause and cause-specific mortality. METHODS: Data from consecutive patients undergoing TLE in our institution between 2012 and 2020 were retrospectively analyzed. Periprocedural, 30-day, long-term, and cause-specific mortalities were calculated. We examined the original and the revised CIED indications and survival rate of patients with or without reimplantation. RESULTS: A total of 150 patients (age 66 ± 14 years) with 308 leads (dwelling time 7.8 ± 6.3 years) underwent TLE due to pocket infection (n = 105, 70%), endocarditis (n = 35, 23%), or non-infectious indications (n = 10, 7%). All-cause mortality data were available for all patients, detailed reimplantation data in 98 cases. Procedural death rate was 2% (n = 3), 30-day mortality rate 2.6% (n = 4). During the 3.5 ± 2.4 years of follow-up, 44 patients died. Arrhythmia, as the direct cause of death, was absent. Cardiovascular cause was responsible for mortality in 25%. There was no significant survival difference between groups with or without reimplantation (p = 0.136). CONCLUSIONS: Despite the high number of pocket and systemic infection and long dwelling times in our cohort, the short- and long-term mortality after TLE proved to be favorable. Moreover, survival without a new device was not worse compared to patients who underwent a reimplantation procedure. Our study underlines the importance of individual reassessment of the original CIED indication, to avoid unnecessary reimplantation.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Arritmias Cardíacas/terapia , Taxa de Sobrevida , Remoção de Dispositivo/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA