Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
J Magn Reson Imaging ; 53(5): 1311-1317, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32808391

RESUMO

Historically, the presence of cardiac implantable electronic devices (CIEDs), including pacemakers and implantable cardioverter defibrillators (ICDs), was widely considered an absolute contraindication to magnetic resonance imaging (MRI). The recent development of CIEDs with MR Conditional labeling, as well as encouraging results from retrospective studies and a prospective trial on the safety of MRI performed in patients with CIEDs without MR Conditional labeling, have led to a reevaluation of this practice. The purpose of this report is to provide a concise summary of recent developments, including practical guidelines that an institution could adopt for radiologists who choose to image patients with CIEDs that do not have MR Conditional labeling. This report was written on behalf of and approved by the International Society for Magnetic Resonance in Medicine (ISMRM) Safety Committee. LEVEL OF EVIDENCE: 3. TECHNICAL EFFICACY STAGE: 1.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Eletrônica , Humanos , Imageamento por Ressonância Magnética , Estudos Prospectivos , Estudos Retrospectivos
2.
Magn Reson Med ; 72(2): 510-21, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24006275

RESUMO

PURPOSE: To propose a novel approach to water/fat separation using a unique smoothness constraint. THEORY AND METHODS: Chemical-shift based water/fat separation is an established noninvasive imaging tool for the visualization of body fat in various anatomies. Nevertheless, B0 magnetic field inhomogeneities can hamper the water/fat separation process. In this work, B0 variations are mapped using a convex-relaxed labeling model which produces a coarse estimate of the field map, while considering T2* decay during the labeling process. Fat and water components are subsequently resolved using T2*-IDEAL. An adaptive spatial filtering (ASF) was introduced to improve the robustness of the estimate. The method was tested on cardiac and abdominal datasets from healthy volunteers and nonalcoholic fatty liver disease (NAFLD) patients. RESULTS: Out of 168 cardiac and abdominal images, only 1 case has shown water/fat swaps that can hinder the clinical interpretation of the underlying anatomy. CONCLUSION: This work demonstrates a new water/fat separation approach that prevents the occurrence of water/fat swaps, by means of a unique smoothness constraint. Incorporating T2* effect in the labeling procedure and including the ASF processing enhance the robustness of the proposed approach and permit the procedure to handle abrupt B0 variations within the field of view.


Assuntos
Gordura Abdominal/patologia , Tecido Adiposo/patologia , Algoritmos , Água Corporal , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Hepatopatia Gordurosa não Alcoólica/patologia , Humanos , Aumento da Imagem/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Magn Reson Med ; 72(3): 718-25, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24186810

RESUMO

PURPOSE: To develop and evaluate a free-breathing chemical-shift-encoded (CSE) spoiled gradient-recalled echo (SPGR) technique for whole-heart water-fat imaging at 3 Tesla (T). METHODS: We developed a three-dimensional (3D) multi-echo SPGR pulse sequence with electrocardiographic gating and navigator echoes and evaluated its performance at 3T in healthy volunteers (N = 6) and patients (N = 20). CSE-SPGR, 3D SPGR, and 3D balanced-SSFP with chemical fat saturation were compared in six healthy subjects with images evaluated for overall image quality, level of residual artifacts, and quality of fat suppression. A similar scoring system was used for the patient datasets. RESULTS: Images of diagnostic quality were acquired in all but one subject. CSE-SPGR performed similarly to SPGR with fat saturation, although it provided a more uniform fat suppression over the whole field of view. Balanced-SSFP performed worse than SPGR-based methods. In patients, CSE-SPGR produced excellent fat suppression near metal. Overall image quality was either good (7/20) or excellent (12/20) in all but one patient. There were significant artifacts in 5/20 clinical cases. CONCLUSION: CSE-SPGR is a promising technique for whole-heart water-fat imaging during free-breathing. The robust fat suppression in the water-only image could improve assessment of complex morphology at 3T and in the presence of off-resonance, with additional information contained in the fat-only image.


Assuntos
Doenças Cardiovasculares/diagnóstico , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Tecido Adiposo , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Artefatos , Técnicas de Imagem de Sincronização Cardíaca , Meios de Contraste , Feminino , Voluntários Saudáveis , Humanos , Imageamento Tridimensional/métodos , Masculino , Meglumina/análogos & derivados , Pessoa de Meia-Idade , Compostos Organometálicos , Estudos Prospectivos , Água
4.
J Magn Reson Imaging ; 38(4): 914-25, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23553735

RESUMO

PURPOSE: To determine the effectiveness of MR angiography for pulmonary embolism (MRA-PE) in symptomatic patients. MATERIALS AND METHODS: We retrospectively reviewed all patients whom were evaluated for possible pulmonary embolism (PE) using MRA-PE. A 3-month and 1-year from MRA-PE electronic medical record (EMR) review was performed. Evidence for venous thromboembolism (VTE) (or death from PE) within the year of follow-up was the outcome surrogate for this study. RESULTS: There were 190 MRA-PE exams performed with 97.4% (185/190) of diagnostic quality. There were 148 patients (120 F: 28 M) that had both a diagnostic MRA-PE exam and 1 complete year of EMR follow-up. There were 167 patients (137 F: 30 M) with 3 months or greater follow-up. We found 83% (139/167) and 81% (120/148) MRA-PE exams negative for PE at 3 months and 1 year, respectively. Positive exams for PE were seen in 14% (23/167). During the 1-year follow-up period, five patients (false negative) were diagnosed with DVT (5/148 = 3.4 %), and one of these patients also experienced a non-life-threatening PE. The negative predictive value (NPV) for MRA-PE was 97% (92-99; 95% CI) at 3 months and 96% (90-98; 95% CI) with 1 year of follow-up. CONCLUSION: The NPV of MRA-PE, when used for the primary diagnosis of pulmonary embolism in symptomatic patients, were found to be similar to the published values for CTA-PE. In addition, the technical success rate and safety of MRA-PE were excellent.


Assuntos
Angiografia por Ressonância Magnética , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/patologia , Doença Aguda , Adulto , Registros Eletrônicos de Saúde , Reações Falso-Negativas , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Artéria Pulmonar/patologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Tromboembolia Venosa/diagnóstico , Tromboembolia Venosa/patologia , Adulto Jovem
5.
Magn Reson Med ; 68(3): 830-40, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22161866

RESUMO

R2 mapping has important applications in MRI, including functional imaging, tracking of super-paramagnetic particles, and measurement of tissue iron levels. However, R2 measurements can be confounded by several effects, particularly the presence of fat and macroscopic B0 field variations. Fat introduces additional modulations in the signal. Macroscopic field variations introduce additional dephasing that results in accelerated signal decay. These effects produce systematic errors in the resulting R2 maps and make the estimated R2 values dependent on the acquisition parameters. In this study, we develop a complex-reconstruction, confounder-corrected R2 mapping technique, which addresses the presence of fat and macroscopic field variations for both 2D and 3D acquisitions. This technique extends previous chemical shift-encoded methods for R2, fat and water mapping by measuring and correcting for the effect of macroscopic field variations in the acquired signal. The proposed method is tested on several 2D and 3D phantom and in vivo liver, cardiac, and brain datasets.


Assuntos
Algoritmos , Artefatos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Fígado/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Catheter Cardiovasc Interv ; 80(7): 1090-8, 2012 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-23097307

RESUMO

OBJECTIVES: To demonstrate the feasibility of magnetic resonance imaging (MRI) to X-ray fluoroscopy (XRF) image fusion to guide peripheral artery chronic total occlusion (CTO) recanalization. BACKGROUND: Endovascular peripheral artery CTO revascularization is minimally invasive, but challenging, because the occlusion is poorly visualized under XRF. Devices may steer out of the artery, which can lead to severe perforation. Merging preacquired MRI of the CTO to the live XRF display may permit upfront use of aggressive devices and improve procedural outcomes. METHODS: Swine carotid artery CTOs were created using a balloon injury model. Up to 8 weeks later, MRI of the carotid arteries was acquired and segmented to create three-dimensional surface models, which were then registered onto live XRF. CTO recanalization was performed using incrementally aggressive CTO devices (group A) or an upfront aggressive directed laser approach (group B). Procedural success was defined as luminal or subintimal device position without severe perforation. RESULTS: In this swine model, MRI to XRF fusion guidance resulted in a procedural success of 57% in group A and 100% in group B, which compared favorably to 33% using XRF alone. Fluoroscopy time was significantly less for group B (8.5 ± 2.6 min) compared to group A (48.7 ± 23.9 min), P < 0.01. Contrast dose used was similar between groups A and B. CONCLUSIONS: MRI to XRF fusion-guided peripheral artery CTO recanalization is feasible. Multimodality image fusion may permit upfront use of aggressive CTO devices with improved procedural outcomes compared to XRF-guided procedures.


Assuntos
Lesões das Artérias Carótidas/terapia , Estenose das Carótidas/terapia , Cateterismo Periférico , Procedimentos Endovasculares , Imagem por Ressonância Magnética Intervencionista , Radiografia Intervencionista , Terapia Assistida por Computador , Animais , Lesões das Artérias Carótidas/diagnóstico por imagem , Lesões das Artérias Carótidas/patologia , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/patologia , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/instrumentação , Doença Crônica , Modelos Animais de Doenças , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Desenho de Equipamento , Estudos de Viabilidade , Fluoroscopia , Imagem por Ressonância Magnética Intervencionista/efeitos adversos , Imagem por Ressonância Magnética Intervencionista/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Intervencionista/efeitos adversos , Radiografia Intervencionista/instrumentação , Suínos , Terapia Assistida por Computador/instrumentação , Dispositivos de Acesso Vascular , Lesões do Sistema Vascular/etiologia , Lesões do Sistema Vascular/prevenção & controle
7.
J Magn Reson Imaging ; 34(3): 585-94, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21751288

RESUMO

PURPOSE: To evaluate the signal to noise ratio (SNR) and contrast to noise ratio (CNR) performance of 0.05 mmol/kg gadoxetic acid and 0.1 mmol/kg gadobenate dimeglumine for dynamic and hepatobiliary phase imaging. In addition, flip angles (FA) that maximize relative contrast-to-noise performance for hepatobiliary phase imaging were determined. MATERIALS AND METHODS: A cross-over study in 10 volunteers was performed using each agent. Imaging was performed at 3 Tesla (T) with a 32-channel phased-array coil using breathheld 3D spoiled gradient echo sequences for SNR and CNR analysis, and for FA optimization of hepatobiliary phase imaging. RESULTS: Gadobenate dimeglumine (0.1 mmol/kg) had superior SNR performance during the dynamic phase, statistically significant for portal vein and hepatic vein in the portal venous and venous phase (for all, P < 0.05) despite twice the approved dose of gadoxetic acid (0.05 mmol/kg), while gadoxetic acid had superior SNR performance during the hepatobiliary phase. Optimal FAs for hepatobiliary phase imaging using gadoxetic acid and gadobenate dimeglumine were 25-30° and 20-30° for relative contrast liver versus muscle (surrogate for nonhepatocellular tissues), and 45° and 20° (relative contrast liver versus biliary structures), respectively. CONCLUSION: Gadobenate dimeglumine may be preferable for applications that require dynamic phase imaging only, while gadoxetic acid may be preferable when the hepatobiliary phase is clinically important. Hepatobiliary phase imaging with both agents benefits from flip angle optimization.


Assuntos
Sistema Biliar/anatomia & histologia , Gadolínio DTPA , Aumento da Imagem/métodos , Fígado/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Meglumina/análogos & derivados , Compostos Organometálicos , Adulto , Meios de Contraste , Estudos Cross-Over , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído , Adulto Jovem
8.
J Magn Reson Imaging ; 33(4): 873-81, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21448952

RESUMO

PURPOSE: To determine the precision and accuracy of hepatic fat-fraction measured with a chemical shift-based MRI fat-water separation method, using single-voxel MR spectroscopy (MRS) as a reference standard. MATERIALS AND METHODS: In 42 patients, two repeated measurements were made using a T(1) -independent, T 2*-corrected chemical shift-based fat-water separation method with multi-peak spectral modeling of fat, and T(2) -corrected single voxel MR spectroscopy. Precision was assessed through calculation of Bland-Altman plots and concordance correlation intervals. Accuracy was assessed through linear regression between MRI and MRS. Sensitivity and specificity of MRI fat-fractions for diagnosis of steatosis using MRS as a reference standard were also calculated. RESULTS: Statistical analysis demonstrated excellent precision of MRI and MRS fat-fractions, indicated by 95% confidence intervals (units of absolute percent) of [-2.66%,2.64%] for single MRI ROI measurements, [-0.81%,0.80%] for averaged MRI ROI, and [-2.70%,2.87%] for single-voxel MRS. Linear regression between MRI and MRS indicated that the MRI method is highly accurate. Sensitivity and specificity for detection of steatosis using averaged MRI ROI were 100% and 94%, respectively. The relationship between hepatic fat-fraction and body mass index was examined. CONCLUSION: Fat-fraction measured with T(1) -independent T 2*-corrected MRI and multi-peak spectral modeling of fat is a highly precise and accurate method of quantifying hepatic steatosis.


Assuntos
Tecido Adiposo/patologia , Água Corporal/química , Fígado Gorduroso/patologia , Espectroscopia de Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Análise de Regressão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Catheter Cardiovasc Interv ; 78(3): 468-78, 2011 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-21413125

RESUMO

OBJECTIVES: To validate a multi-modality image fusion approach to guide catheter-based, targeted transendocardial therapeutic delivery in a swine myocardial infarction (MI) model. BACKGROUND: Biologic agents such as stem cells may curb post MI adverse ventricular remodeling if delivered by a transendocardial catheter directly into the infarct border. 3D visualization of the infarct and other cardiac surfaces is required to perform this task. We propose registering and overlaying magnetic resonance imaging (MRI) roadmaps onto live x-ray fluoroscopy (XRF) to guide targeted transendocardial delivery. METHODS: Custom software was used to register and overlay MRI models of the endocardium and infarct on live XRF by aligning common endocardial border features. In a swine MI model, transendocardial injections of co-localizing imaging labels were performed, targeting a 20 mm perimeter around the infarct. Directed targeting error (DTE) was defined as the difference between the predicted injection site-to-infarct distance calculated by the image fusion system, to the actual distance determined by postprocedure in vivo MRI. The mobile image fusion system was designed to be vendor-independent for imaging systems and transendocardial catheters. RESULTS: Transendocardial injections were performed in all animals without complications. Mean DTE was 0.9 ± 5.0 mm (n = 8 swine). Time to register the images and establish a high quality roadmap was less than 12 min in all animals. Custom imaging tools to display injection sites and distribution were useful adjuncts during targeted injection procedures. CONCLUSIONS: Multi-modality image fusion is a feasible and accurate platform technology to guide transendocardial injections precisely to the discrete infarct border.


Assuntos
Cateterismo Cardíaco , Endocárdio/diagnóstico por imagem , Endocárdio/patologia , Interpretação de Imagem Assistida por Computador , Imagem por Ressonância Magnética Intervencionista , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/patologia , Radiografia Intervencionista , Animais , Meios de Contraste/administração & dosagem , Dextranos/administração & dosagem , Modelos Animais de Doenças , Estudos de Viabilidade , Fluoroscopia , Injeções , Iohexol/administração & dosagem , Nanopartículas de Magnetita/administração & dosagem , Modelos Animais , Infarto do Miocárdio/terapia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Software , Suínos
10.
Hum Gene Ther ; 18(3): 257-68, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17376006

RESUMO

The purpose of this work is to investigate the use of magnetic resonance imaging (MRI) to monitor the effects of high-pressure naked plasmid DNA (pDNA) intravascular injections in primate limbs, studying both the distribution of the injected solution in the muscle space, as well as the effects on the vascular system. The distal portion of the four limbs of each of six rhesus monkeys were hydrodynamically injected with naked pDNA, which expressed the luciferase reporter gene. Three-dimensional (3D) T1-weighted gradient echo and 2D multislice T2-weighted fast spin echo (FSE) series were acquired before and immediately after the injection to confirm the volume of solution injected into the limb, and to study the distribution of the injected solution in the individual muscle groups. Time-resolved contrast-enhanced 3D magnetic resonance angiography (MRA) was performed several days before, immediately after, and in a follow-up examination after the pDNA injection to study the effects of the procedure on the primate peripheral vascular system. T1-weighted gradient echo imaging confirmed the delivery of the majority of the solution after successful pDNA injections. T2-weighted FSE imaging demonstrated the distribution of the saline solution in individual muscles in the target limbs, with enhancement showing a weak but significant correlation with the level of gene expression. Time-resolved contrast-enhanced MRA demonstrated effects of the injection procedure on the arterial and venous vascular systems, and the intramuscular compartments; and these effects largely returned to normal on short-term follow-up.


Assuntos
DNA/farmacocinética , Luciferases/análise , Imageamento por Ressonância Magnética , Músculo Esquelético/metabolismo , Plasmídeos/farmacocinética , Transdução Genética , Animais , DNA/administração & dosagem , Injeções Intravenosas , Luciferases/genética , Macaca mulatta , Angiografia por Ressonância Magnética , Masculino , Plasmídeos/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA