Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Arch Orthop Trauma Surg ; 137(3): 311-320, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28091739

RESUMO

INTRODUCTION: Total hip arthroplasty (THA) with uncemented implants has been a relatively common procedure in Finland during the recent decades. The most common brand of uncemented implants was chosen for further analysis to study the survivorship of this uncemented cup design in comparison to cemented references. PATIENTS, MATERIALS AND METHODS: Since 1980, The Finnish Arthroplasty Register has collected information on THAs on a national level. This study was based on information of THAs recorded in the Finnish Arthroplasty Register from 1985 to 2013. If patient had undergone bilateral THA, only the first one was included. Altogether, 49,289 THAs were included. RESULTS: The overall 10-year implant survivorship of uncemented implants was 84.3% (95% CI 83.5-85.0%) and of cemented implants 90.6% (90.2-90.0%). The 10-year survival of the contemporary uncemented implants was 90.8% (94.0-95.5%) and 88.5% (84.2-91.7%). The most recently introduced uncemented cup designs had good survivorship rates at 5 years; 10-year survival data are not yet available. CONCLUSIONS: We found that modern uncemented cup designs may provide good long-term survivorship rates comparable with the gold standard of cemented cups. However, polyethylene wear, liner problems and periosthetic osteolysis may still occur, also with modern uncemented acetabular components.


Assuntos
Artroplastia de Quadril/métodos , Prótese de Quadril , Desenho de Prótese , Falha de Prótese , Sistema de Registros , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Finlândia/epidemiologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Osteólise/epidemiologia , Polietileno , Complicações Pós-Operatórias/epidemiologia , Modelos de Riscos Proporcionais , Reoperação/estatística & dados numéricos , Resultado do Tratamento , Adulto Jovem
2.
Scand J Public Health ; 44(1): 106-15, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26355119

RESUMO

AIMS: The aim of the narrative review was to describe and analyze lower extremity musculoskeletal disorders (MSDs) in nurses and to identify factors associated with these disorders. The ultimate goal was to promote lower extremity health in nurses by recognizing factors that could improve their well-being at work. METHODS: A systematic search on the Medline, CINAHL, and PsychInfo databases was conducted, producing altogether 945 citations, of which 35 were selected for this review. The studies were analyzed by content analysis. RESULTS: Nurses have different MSDs in their lower extremities, with which the knee, foot, and ankle being most commonly affected. These problems are often correlated, and problems in the ankle can first appear as knee problems. CONCLUSIONS: Musculoskeletal disorders in lower extremities and their resulting disability are common within the nursing workforce worldwide, representing a major cause of sick leave absence and often leading to long-term absence.


Assuntos
Extremidade Inferior/fisiopatologia , Doenças Musculoesqueléticas/epidemiologia , Enfermeiras e Enfermeiros , Doenças Profissionais/epidemiologia , Humanos , Narração , Fatores de Risco
3.
Acta Orthop ; 87(6): 554-559, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27759474

RESUMO

Background and purpose - In a previous registry report, short-term implant survival of hip resurfacing arthroplasty (HRA) in Finland was found to be comparable to that of total hip arthroplasty (THA). Since then, it has become evident that adverse reactions to metal debris (ARMDs) may also be associated with HRA, not only with large-diameter head metal-on-metal THA. The aim of the study was to assess medium- to long-term survivorship of HRA based on the Finnish Arthroplasty Register (FAR). Patients and methods - 5,068 HRAs performed during the period 2001-2013 in Finland were included. Kaplan-Meier survival analysis was used to calculate survival probabilities and their 95% confidence intervals (CIs). Cox multiple regression, with adjustment for age, sex, diagnosis, femoral head size, and hospital volume was used to analyze implant survival of HRA devices with revision for any reason as endpoint. The reference group consisted of 6,485 uncemented Vision/Bimetric and ABG II THAs performed in Finland over the same time period. Results - The 8-year survival, with any revision as an endpoint, was 93% (CI: 92-94) for Birmingham Hip Resurfacing (BHR), 86% (CI: 78-94) for Corin, 91% (CI: 89-94) for ReCap, 92% (CI: 89-96) for Durom, and was 72% (CI: 69-76) for the Articular Surface Replacement (ASR). The 10-year survival, with any revision as an endpoint, for reference THAs was 92% (CI: 91-92) and for all HRAs it was 86% (CI: 84-87%). Female HRA patients had about twice the revision risk of male patients. ASR had an inferior outcome: the revision risk was 4-fold higher than for BHR, the reference implant. Interpretation - The 10-year implant survival of HRAs is 86% in Finland. According to new recommendations from NICE (The National Institute for Health and Care Excellence), an HRA/THA should have a revision rate of 5% or less at 10 years. None of the HRAs studied achieved this goal.


Assuntos
Artroplastia de Quadril/efeitos adversos , Cabeça do Fêmur/cirurgia , Previsões , Prótese de Quadril/efeitos adversos , Osteoartrite do Quadril/cirurgia , Sistema de Registros , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Finlândia/epidemiologia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/mortalidade , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Adulto Jovem
4.
Knee Surg Sports Traumatol Arthrosc ; 23(2): 567-72, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23996071

RESUMO

PURPOSE: The aim of this study was to evaluate the relationship between the tear size and the short-term clinical outcome of rotator cuff reconstruction. The hypothesis was that the size of the rotator cuff tear has a direct negative correlation with post-operative clinical outcome. METHODS: Five hundred and seventy-six consecutive shoulders with a primarily arthroscopically treated full-thickness rotator cuff tear were followed up. Rotator cuff tear size (anteroposterior dimension) was measured intraoperatively with an arthroscopic measuring probe. The Constant score was used as an outcome measure and was measured pre-operatively and 1-year post-operatively. RESULTS: Five hundred and sixty-nine patients (99 %) were available for 1-year follow-up. The mean age of patients was 59.6 (SD 9.6) years. There were 225 (40 %) female and 344 (60 %) male patients. The mean size of the rotator cuff tear was 25 mm (SD 18). The mean pre- and post-operative Constant score was 52.3 (SD 17.4) and 74.2 (SD 15.5), respectively (p < 0.0001). The intraoperatively detected tear size correlated significantly with the pre-operative Constant score (r = -0.20, p < 0.0001). Furthermore, there was even stronger and significant correlation between the tear size and the final post-operative Constant score (r = -0.36, p < 0.0001). The correlation was similar between the genders, but the Constant scores were significantly lower in women (p < 0.0001). The lowest scores were detected in tears with infraspinatus tendon involvement. CONCLUSIONS: The size of the rotator cuff tear linearly correlates with the Constant scores both pre- and post-operatively. The outcome of rotator cuff reconstruction is strongly related to the intraoperatively detected tear size. LEVEL OF EVIDENCE: Retrospective comparative register study, Level III.


Assuntos
Manguito Rotador/cirurgia , Traumatismos dos Tendões/cirurgia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos , Manguito Rotador/patologia , Lesões do Manguito Rotador , Ruptura , Traumatismos dos Tendões/patologia , Resultado do Tratamento
5.
Acta Orthop ; 86(3): 345-50, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25582189

RESUMO

BACKGROUND AND PURPOSE: Concern has emerged about local soft-tissue reactions after hip resurfacing arthroplasty (HRA). The Birmingham Hip Resurfacing (BHR) was the most commonly used HRA device at our institution. We assessed the prevalence and risk factors for adverse reaction to metal debris (ARMD) with this device. PATIENTS AND METHODS: From 2003 to 2011, BHR was the most commonly used HRA device at our institution, with 249 implantations. We included 32 patients (24 of them men) who were operated with a BHR HRA during the period April 2004 to March 2007 (42 hips; 31 in men). The mean age of the patients was 59 (26-77) years. These patients underwent magnetic resonance imaging (MRI), serum metal ion measurements, the Oxford hip score questionnaire, and physical examination. The prevalence of ARMD was recorded, and risk factors for ARMD were assessed using logistic regression models. The mean follow-up time was 6.7 (2.4-8.8) years. RESULTS: 6 patients had a definite ARMD (involving 9 of the 42 hips). 8 other patients (8 hips) had a probable ARMD. Thus, there was definite or probable ARMD in 17 of the 42 hips. 4 of 42 hips were revised for ARMD. Gender, bilateral metal-on-metal hip replacement and head size were not factors associated with ARMD. INTERPRETATION: We found that HRA with the Birmingham Hip Resurfacing may be more dangerous than previously believed. We advise systematic follow-up of these patients using metal ion levels, MRI/ultrasound, and patient-reported outcome measures.


Assuntos
Artroplastia de Quadril/instrumentação , Articulação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Próteses Articulares Metal-Metal/efeitos adversos , Metais/efeitos adversos , Adulto , Idoso , Feminino , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/patologia , Humanos , Modelos Logísticos , Imageamento por Ressonância Magnética , Masculino , Metais/sangue , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Prevalência , Radiografia , Estudos Retrospectivos , Fatores de Risco
7.
Acta Orthop ; 85(1): 32-8, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24397743

RESUMO

BACKGROUND AND PURPOSE: Metal-on-metal hip implants have been widely used, especially in the USA, Australia, England and Wales, and Finland. We assessed risk of death and updated data on the risk of cancer related to metal-on-metal hip replacements. PATIENTS AND METHODS: A cohort of 10,728 metal-on-metal hip replacement patients and a reference cohort of 18,235 conventional total hip replacement patients were extracted from the Finnish Arthroplasty Register for the years 2001-2010. Data on incident cancer cases and causes of death until 2011 were obtained from the Finnish Cancer Registry and Statistics Finland. The relative risk of cancer and death were expressed as standardized incidence ratio (SIR) and standardized mortality ratio (SMR). SIR/SIR ratios and SMR/SMR ratios, and Poisson regression were used to compare the cancer risk and the risk of death between cohorts. RESULTS: The overall risk of cancer in the metal-on-metal cohort was not higher than that in the non-metal-on-metal cohort (RR = 0.91, 95% CI: 0.82-1.02). The risk of soft-tissue sarcoma and basalioma in the metal-on-metal cohort was higher than in the non-metal-on-metal cohort (SIR/SIR ratio = 2.6, CI: 1.02-6.4 for soft-tissue sarcoma; SIR/SIR ratio = 1.3, CI: 1.1-1.5 for basalioma). The overall risk of death in the metal-on-metal cohort was less than that in the non-metal-on-metal cohort (RR = 0.78, CI: 0.69-0.88). INTERPRETATION: The overall risk of cancer or risk of death because of cancer is not increased after metal-on-metal hip replacement. The well-patient effect and selection bias contribute substantially to the findings concerning mortality. Arthrocobaltism does not increase mortality in patients with metal-on-metal hip implants in the short term. However, metal-on-metal hip implants should not be considered safe until data with longer follow-up time are available.


Assuntos
Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Neoplasias/epidemiologia , Neoplasias/etiologia , Adulto , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/mortalidade , Artroplastia de Quadril/estatística & dados numéricos , Causas de Morte , Feminino , Finlândia/epidemiologia , Seguimentos , Humanos , Incidência , Masculino , Metais/efeitos adversos , Pessoa de Meia-Idade , Desenho de Prótese , Medição de Risco/métodos , Adulto Jovem
8.
Acta Orthop Belg ; 80(2): 222-7, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25090796

RESUMO

The aim of this retrospective study was to evaluate short- to mid-term results of three different metal-on-metal hip devices from the same manufacturer. A total of 329 hip operations were performed in a single academic unit between 2004 and 2010 using either Birmingham hip resurfacing or Synergy--Birmingham and Synergy--R3 total hip arthroplasty. The overall survival rate at the end of the follow-up time for Birmingham hip resurfacing was 88%, for Synergy--Birmingham total hip arthroplasty 95%, and for Synergy--R3 total hip arthroplasty 81% (p = 0.036). Five revision operations were performed due to adverse reaction to metal debris. Head sizes > 50 mm had lower revision rates compared to smaller ones. Synergy--R3 had a poor survival already at short-term. The mid-term survival of Birmingham hip resurfacing arthroplasty was inferior compared to previous studies.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Próteses Articulares Metal-Metal , Falha de Prótese , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo
10.
Acta Orthop ; 84(4): 342-7, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23799348

RESUMO

BACKGROUND AND PURPOSE: Previous population-based registry studies have shown that larger femoral head size is associated with reduced risk of revision for dislocation. However, the previous data have not included large numbers of hip resurfacing arthroplasties or large metal-on-metal (> 36-mm) femoral head arthroplasties. We evaluated the association between femoral component head size and the risk of revision for dislocation after THA by using Finnish Arthroplasty Register data. PATIENTS AND METHODS: 42,379 patients who were operated during 1996-2010 fulfilled our criteria. 18 different cup/stem combinations were included. The head-size groups studied (numbers of cases) were 28 mm (23,800), 32 mm (4,815), 36 mm (3,320), and > 36 mm (10,444). Other risk factors studied were sex, age group (18-49 years, 50-59 years, 60-69 years, 70-79 years, and > 80 years), and time period of operation (1996-2000, 2001-2005, 2006-2010). RESULTS: The adjusted risk ratio in the Cox model for a revision operation due to dislocation was 0.40 (95% CI: 0.26-0.62) for 32-mm head size, 0.41 (0.24-0.70) for 36-mm head size, and 0.09 (0.05-0.17) for > 36-mm head size compared to implants with a head size of 28 mm. INTERPRETATION: Larger femoral heads clearly reduce the risk of dislocation. The difference in using heads of > 36 mm as opposed to 28-mm heads for the overall revision rate at 10 years follow-up is about 2%. Thus, although attractive from a mechanical point of view, based on recent less favorable clinical outcome data on these large heads, consisting mainly of metal-on-metal prostheses, one should be cautious using these implants.


Assuntos
Artroplastia de Quadril/estatística & dados numéricos , Cabeça do Fêmur/cirurgia , Luxação do Quadril/cirurgia , Falha de Prótese , Reoperação/estatística & dados numéricos , Medição de Risco/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Feminino , Cabeça do Fêmur/anatomia & histologia , Finlândia , Humanos , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Sistema de Registros , Fatores de Risco , Análise de Sobrevida , Adulto Jovem
11.
Acta Orthop ; 84(6): 549-54, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24171688

RESUMO

BACKGROUND AND PURPOSE: The clinical findings of adverse reaction to metal debris (ARMD) following large-diameter-head metal-on-metal total hip arthroplasty (LDH MoM THA) may include periarticular fluid collections, soft tissue masses, and gluteal muscle necrosis. The ReCap-M2a-Magnum LDH MoM THA was the most commonly used hip device at our institution from 2005 to 2012. We assessed the prevalence of and risk factors for ARMD with this device. METHODS: 74 patients (80 hips) had a ReCap-M2a-Magnum LDH MoM THA during the period August 2005 to December 2006. These patients were studied with hip MRI, serum chromium and cobalt ion measurements, the Oxford hip score questionnaire, and by clinical examination. The prevalence of ARMD was recorded and risk factors for ARMD were assessed using logistic regression models. The mean follow-up time was 6.0 (5.5-6.7) years. RESULTS: A revision operation due to ARMD was needed by 3 of 74 patients (3 of 80 hips). 8 additional patients (8 hips) had definite ARMD, but revision was not performed. 29 patients (32 hips) were considered to have a probable or possible ARMD. Altogether, 43 of 80 hips had a definite, probable, or possible ARMD and 34 patients (37 hips) were considered not to have ARMD. In 46 of 78 hips, MRI revealed a soft tissue mass or a collection of fluid (of any size). The symptoms clicking in the hip, local hip swelling, and a feeling of subluxation were associated with ARMD. INTERPRETATION: ARMD is common after ReCap-M2a-Magnum total hip arthroplasty, and we discourage the use of this device. Asymptomatic patients with a small fluid collection on MRI may not need instant revision surgery but must be followed up closely.


Assuntos
Artroplastia de Quadril/efeitos adversos , Reação a Corpo Estranho/etiologia , Prótese de Quadril/efeitos adversos , Metais/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/instrumentação , Cromo/sangue , Cobalto/sangue , Feminino , Seguimentos , Reação a Corpo Estranho/sangue , Reação a Corpo Estranho/diagnóstico , Articulação do Quadril/patologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Reoperação , Fatores de Risco
12.
Duodecim ; 129(14): 1440-8, 2013.
Artigo em Fi | MEDLINE | ID: mdl-23961602

RESUMO

Most commonly, shoulder instability results from a traumatic dislocation of the shoulder joint, usually happening to men under the age of 30. The first uncomplicated dislocation is treated conservatively. Instability refers to symptomatic instability of the shoulder joint, i.e. recurrent dislocations or fear of dislocation. Clinical examination and X-ray are usually sufficient for diagnosis. While mechanical instability of the shoulder joint is an indication for surgery, the operative technique should be selected in a patient-specific manner.


Assuntos
Instabilidade Articular/cirurgia , Luxação do Ombro/cirurgia , Lesões do Ombro , Humanos , Instabilidade Articular/diagnóstico , Instabilidade Articular/etiologia , Luxação do Ombro/diagnóstico , Luxação do Ombro/etiologia
13.
Acta Orthop ; 83(3): 207-13, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22616745

RESUMO

BACKGROUND AND PURPOSE: Population-based registry data from the Nordic Arthroplasty Register Association (NARA) and from the National Joint Register of England and Wales have revealed that the outcome after hip resurfacing arthroplasty (HRA) is inferior to that of conventional total hip arthroplasty (THA). We analyzed the short-term survival of 4,401 HRAs in the Finnish Arthroplasty Register. METHODS: We compared the revision risk of the 4,401 HRAs from the Register to that of 48,409 THAs performed during the same time period. The median follow-up time was 3.5 (0-9) years for HRAs and 3.9 (0-9) years for THAs. RESULTS: There was no statistically significant difference in revision risk between HRAs and THAs (RR = 0.93, 95% CI: 0.78-1.10). Female patients had about double the revision risk of male patients (RR = 2.0, CI: 1.4-2.7). Hospitals that had performed 100 or more HRA procedures had a lower revision risk than those with less than 100 HRAs (RR = 0.6, CI: 0.4-0.9). Articular Surface Replacement (ASR, DePuy) had inferior outcome with higher revision risk than the Birmingham Hip Resurfacing implant (BHR, Smith & Nephew), the reference implant (RR = 1.8, CI: 1.2-2.7). INTERPRETATION: We found that HRA had comparable short-term survivorship to THA at a nationwide level. Implant design had an influence on revision rates. ASR had higher revision risk. Low hospital procedure volume worsened the outcome of HRA. Female patients had twice the revision risk of male patients.


Assuntos
Artroplastia de Quadril/estatística & dados numéricos , Prótese de Quadril/normas , Osteoartrite do Quadril/cirurgia , Adolescente , Adulto , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/normas , Criança , Feminino , Tamanho das Instituições de Saúde/estatística & dados numéricos , Prótese de Quadril/estatística & dados numéricos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Noruega/epidemiologia , Desenho de Prótese/estatística & dados numéricos , Falha de Prótese , Sistema de Registros , Reoperação/estatística & dados numéricos , Fatores de Risco , Disfunções Sexuais Fisiológicas , Adulto Jovem
14.
J Orthop Surg Res ; 16(1): 35, 2021 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-33422084

RESUMO

BACKGROUND: Whilst bony fixation of hip replacement has stable solutions, there remains controversy over which bearing best optimizes longevity and function. Ceramic-on-ceramic (CoC) bearing combinations are associated with lower risk of revision due to aseptic loosening and dislocation. Evidence for long-term functional outcomes of modern, 4th generation CoC bearings is limited. The aim of this study was to analyze outcomes and complications of the R3™ Acetabular System (Smith & Nephew, Inc., Cordova, TN, USA) in combination with BIOLOX® Delta ceramic femoral head in patients undergoing primary total hip arthroplasty (THA). METHODS: Between June 2009 and May 2011, 175 patients (178 hips) were enrolled into a prospective, study at 6 sites in Europe and prospectively followed-up at 3 months and 1, 3, 5, and 7 years postoperative. RESULTS: Total WOMAC score improved from 63 (range, 22-91) preoperative to 8 (range, 0-8) at 1-year follow-up and remained unchanged at 7-year follow-up. Modified Harris hip score improved from 45 (range, 10-87) preoperative to 83 (range, 25-100) at 3 months, 91 (range, 42-100) at 1 year, and 92 (range, 46, 100) at 7 years. UCLA Activity Rating Scale score improved from 3.3 (range, 1-8) preoperative to 6.2 (range, 2-8) at 1 year; it marginally declined to 5.8 (range, 3-8) at 7-year follow-up. There were 4 trochanteric fractures and 5 patients died of unrelated reasons. Three hips were revised (2 periprosthetic fractures and 1 subluxation). The 7-year cumulative survival rate was 98.3%. CONCLUSION: Clinical and functional improvements of THA with CoC bearing are maintained at 7 years postoperative. TRIAL REGISTRATION: ClinicalTrials.Gov, NCT03566082 , Registered 10 January 2018-retrospectively registered.


Assuntos
Artroplastia de Quadril/métodos , Cerâmica , Prótese de Quadril , Desenho de Prótese , Acetábulo , Adolescente , Adulto , Idoso , Feminino , Cabeça do Fêmur , Seguimentos , Articulação do Quadril/cirurgia , Humanos , Artropatias/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Falha de Prótese , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
15.
Patient Educ Couns ; 103(4): 777-787, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31767243

RESUMO

OBJECTIVE: The purpose of this systematic review was to identify generic instruments measuring patient empowerment and related concepts and analyse the main content and psychometric properties of these instruments. METHODS: A systematic search was conducted using empowerment and related concepts (enablement, activation, engagement, perceived control) as search terms. The main content of the instruments was analysed by classifying the subscales and items of the elements of empowerment into patient's capacities, patient's knowledge, patient's behaviour and support by others. Psychometric properties were analysed with the criteria of Terwee and colleagues (2007). RESULTS: Thirteen instruments were identified; and out of them, five instruments covered all the four elements used to define of empowerment. Psychometric properties were variable; none of the instruments contained all the evaluated psychometric properties. CONCLUSION: There are generic instruments measuring empowerment and its related concepts. The instruments were heterogeneous in structure and psychometric properties. Empowerment is more wide-ranging and multidimensional than its related concepts. PRACTICE IMPLICATIONS: This review provides knowledge for healthcare professionals and researchers who want to support or evaluate patients' empowerment. With a generic instrument, it is possible to obtain comparable information from diverse patient groups. Further testing of psychometric properties of each instrument is recommended.


Assuntos
Pessoal de Saúde , Participação do Paciente , Humanos , Psicometria , Inquéritos e Questionários
16.
Hip Int ; 30(6): 711-717, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31296057

RESUMO

BACKGROUND: Surgeons are increasingly using larger femoral head sizes in total hip arthroplasty (THA) to improve stability and reduce the rate of dislocation, 1 of the leading causes of revision surgery. Large ceramic head sizes up to 48 mm can now be used with monoblock acetabular components. National registries have shown promising results at short-term with large diameter ceramic-on-ceramic THA, with very low revision rates.This study reports on the average 3-year follow up of a press-fit monoblock large diameter acetabular shell with a pre-assembled ceramic liner, with emphasis on the radiographic outcome, complications related to the implantation of the cup, and the patient's clinical outcome. METHODS: 170 hips in 169 patients were reviewed at an average 38 ± 5.8 months following surgery. RESULTS: The radiographic review revealed no acetabular cup loosening, no osteolysis and no cup migration. 1 acetabular cup was revised for malposition. The patient clinical outcome and the satisfaction rate were excellent. At 3 years, 7.1% of patients complained of groin pain and 3.5% spontaneously reported hip joint generated noise. 1 patient sustained a non-recurrent traumatic hip dislocation 2 years post surgery. CONCLUSIONS: New technology should be introduced cautiously on the market. This is especially true for the large diameter ceramic monoblock acetabular component used in this study since it involves a new acetabular component design. At short term, we have not identified new modes of failure with this implant. Longer follow-up is still needed to assess the safety of large ceramic bearing in THA.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Cerâmica , Cabeça do Fêmur/cirurgia , Luxação do Quadril/cirurgia , Prótese de Quadril , Adulto , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Reoperação/efeitos adversos , Fatores de Tempo
18.
J Rehabil Med ; 50(5): 393-401, 2018 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-29392329

RESUMO

OBJECTIVE: To evaluate the evidence regarding the effectiveness of conservative treatment in reducing patellofemoral pain. DATA SOURCES: CENTRAL, MEDLINE, CINAHL, and PEDro databases. STUDY SELECTION: Adults with patellofemoral pain, randomized controlled trials only, any conservative treatment compared with placebo, sham, other conservative treatment, or no treatment. Two independent reviewers. DATA EXTRACTION: Data were extracted from the full-text of the articles, based on Cochrane Collaboration recommendations. The outcome of interest was the difference between groups regarding change in pain severity. DATA SYNTHESIS: The majority of studies were underpowered. More than 80% of the 37 trials did not show a clinically significant benefit. Clinically significant effects of different sizes were found for 7 trials (6 studies out of 7 had short follow-ups). These effects were found for: (i) pulsed electromagnetic fields combined with home exercise -33.0 (95% CI -45.2 to -20.8); (ii) hip muscle strengthening -65.0 (95% CI -87.7 to -48.3) and -32.0 (-37.0 to -27.0); (iii) weight-bearing exercise -40.0 (95% CI -49.4 to -30.6); (iv) neuromuscular facilitation combined with aerobic exercise and stretching -60.1 (95% CI -66.9 to -54.5); (v) postural stabilization -24.4 (95% CI -33.5 to -15.3); and (vi) patellar bracing -31.6 (95% CI -35.2 to -28.0). CONCLUSION: There is no evidence that a single treat-ment modality works for all patients with patellofemoral pain. There is limited evidence that some treatment modalities may be beneficial for some subgroups of patients with patellofemoral pain.


Assuntos
Tratamento Conservador/métodos , Terapia por Exercício/métodos , Síndrome da Dor Patelofemoral/terapia , Adulto , Feminino , Humanos
19.
J Shoulder Elbow Surg ; 16(5): 586-90, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17513136

RESUMO

Conservative therapy has been recommended for the treatment of a chronic cuff lesion with relatively good results. However, recent reports about operative treatment of cuff lesions have yielded more favorable results. Although the current literature seems to favor early treatment, there is an ongoing debate about the timing of the operation. During a 16-year period, 415 chronic full-thickness rotator cuff tears were operated on at our institution. The indication for operative treatment was persistent, severe or moderate pain at rest and impairment of shoulder function after initial conservative treatment. At follow-up, the symptoms were assessed by an interview, and all patients were clinically examined. Pain, function, range of active forward flexion, active abduction, strength (manual muscle testing), and patient satisfaction were recorded, and the results were evaluated by the University of California, Los Angeles shoulder rating scale. On the basis of our results, we recommend operative treatment of the rotator cuff for all cases in which the tear is full thickness, regardless of tear size, if patients have any symptoms, especially pain.


Assuntos
Artroscopia/métodos , Amplitude de Movimento Articular/fisiologia , Lesões do Manguito Rotador , Manguito Rotador/cirurgia , Adulto , Fatores Etários , Idoso , Análise de Variância , Artroscopia/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Satisfação do Paciente , Complicações Pós-Operatórias/fisiopatologia , Probabilidade , Prognóstico , Estudos Retrospectivos , Medição de Risco , Articulação do Ombro/fisiopatologia , Articulação do Ombro/cirurgia , Dor de Ombro/fisiopatologia , Estatísticas não Paramétricas , Resultado do Tratamento
20.
J Orthop Res ; 23(4): 795-801, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16022992

RESUMO

Use of combination adjuvant chemotherapies have improved the disease free survival rate of tumor patients significantly. However, studies have shown that chemotherapeutic agents have negative effects on bone graft incorporation and fixation of porous-coated prostheses needed for reconstruction of bone defects after wide resection of malignant tumors. Unilateral resection of a 6-cm segment of the femoral diaphysis and reconstruction with a porous-coated segmental prosthesis was performed in eight mixed-breed dogs under perioperative chemotherapy with doxorubicin, cisplatin, and ifosfamide. Eight strips of autogenous cortical bone were evenly placed around the junctions between the femur and the prosthetic surface. Autogenous cancellous bone was placed under and between the strips of cortical bone. Two cycles of the chemotherapy were given preoperatively, and three cycles postoperatively. The animals were followed for 12 weeks, with sequential assessments of weight-bearing and radiographic evaluation. Biomechanical, histological, and microradiographic analyses of the retrieved specimens were performed. Doxorubicin, cisplatin, and ifosfamide combination chemotherapy showed a significant effect on new bone formation as seen in reduced callus size and lower ultimate strength of extracortical fixation. However, the onlay corticocancellous grafting method provided better biologic fixation of the prosthesis compared with fixation without any bone grafting under non-chemotherapy condition in a previous study. Extracortical bone grafting is an effective modality for implant fixation even under intensive chemotherapy.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/farmacologia , Neoplasias Ósseas/tratamento farmacológico , Neoplasias Ósseas/cirurgia , Transplante Ósseo , Osseointegração/efeitos dos fármacos , Animais , Antibióticos Antineoplásicos/farmacologia , Antineoplásicos Alquilantes/farmacologia , Cisplatino/farmacologia , Cães , Doxorrubicina/farmacologia , Ifosfamida/farmacologia , Modelos Animais , Radiografia , Neoplasias de Tecidos Moles/tratamento farmacológico , Neoplasias de Tecidos Moles/cirurgia , Tíbia/diagnóstico por imagem , Tíbia/fisiologia , Tíbia/cirurgia , Anormalidade Torcional , Suporte de Carga
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA