Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 91
Filtrar
1.
Electrophoresis ; 44(1-2): 96-106, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36239141

RESUMO

Monoclonal antibodies (mAbs) have become an important class of biopharmaceuticals used for the treatment of various diseases. Their quantification during the manufacturing process is important. In this work, a capillary zone electrophoresis (CZE) method was developed for the monitoring of the mAb concentration during cell-culture processes. CZE method development rules are outlined, particularly discussing various capillary coatings, such as a neutral covalent polyvinyl alcohol coating, a dynamic successive multiple ionic-polymer coating, and dynamic coatings using background electrolyte additives such as triethanolamine (T-EthA) and triethylamine. The dynamic T-EthA coating resulted in most stable electro-osmotic flows and most efficient peak shapes. The method is validated over the range 0.1-10 mg/ml, with a linear range of 0.08-1.3 mg/ml and an extended range of 1-10 mg/ml by diluting samples in the latter concentration range 10-fold in water. The intraday precision and accuracy were 2%-12% and 88%-107%, respectively, and inter-day precision and accuracy were 4%-9% and 93%-104%, respectively. The precision and accuracy of the lowest concentration level (0.08 mg/ml) were slightly worse and still well in scope for monitoring purposes. The presented method proved applicable for analysing in-process cell-culture samples from different cell-culture processes and is possibly well suited as platform method.


Assuntos
Anticorpos Monoclonais , Produtos Biológicos , Anticorpos Monoclonais/análise , Eletroforese Capilar/métodos , Eletrólitos , Álcool de Polivinil
2.
Electrophoresis ; 44(19-20): 1548-1558, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37732546

RESUMO

Biopharmaceutical production takes place in complex processes which should be thoroughly understood. Therefore, the iConsensus project focuses on developing a monitoring platform integrating several process analytical technology tools for integrated, automated monitoring of the biopharmaceutical process. Water-soluble vitamin monitoring using (microchip) capillary electrophoresis (CE) is part of this platform. This work comprises the development of conventional CE methods as the first part towards integrated vitamin monitoring. The vitamins were divided based on their physical-chemical properties to develop two robust methods. Previously, a method for the analysis of cationic vitamins (pyridoxine, pyridoxal, pyridoxamine, thiamine and nicotinamide) in cell culture medium was developed. This work focused on the development of a micellar electrokinetic chromatography method for anionic and neutral vitamins (riboflavin, d-calcium pantothenate, biotin, folic acid, cyanocobalamin and ascorbic acid). By employing multivariate design of experiments, the background electrolyte (BGE) could be optimised within one experiment testing only 11 BGEs. The optimised BGE conditions were 200 mM borate with 77 mM sodium dodecyl sulphate at a pH of 8.6. Using this BGE, all above-mentioned cationic, anionic and neutral vitamins could be separated in clean samples. In cell culture medium, most anionic and neutral vitamins could be separated. Combining the two methods allows for analysis of cationic, anionic and neutral vitamins in cell culture medium samples. The next step towards integrated vitamin monitoring includes transfer to microchip CE. Due to the lack of fast and reliable methods for vitamin monitoring, the developed capillary methods could be valuable as stand-alone at-line process analytical technology solutions as well.

3.
Electrophoresis ; 44(13-14): 1114-1142, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37043774

RESUMO

The process of choosing the most proper technique for studying the molecular interactions is based on critical factors such as instrumentation complexity, automation, experimental procedures, analysis time, consumables, and cost-value. This review has tracked the use of affinity capillary electrophoresis (ACE) and microscale thermophoresis (MST) techniques in the evaluation of molecular binding among different molecules during the 5 years 2016-2021. ACE has proved to be an attractive technique for biomolecular characterization with high resolution efficiency where small variations in several controlling factors can much improve such efficiency compared to other analytical techniques. Meanwhile, MST has proved its higher sensitivity for smaller amounts of complex non-purified biosamples without affecting its robustness while providing high through output. However, the main motivation to review both techniques in the proposed review was their capability to carry out all experiments without the need for immobilizing one interacting partner, besides a great flexibility in the use of buffering systems. The proposed review demonstrates the importance of both techniques in different areas of life sciences. Moreover, the recent advances in exploiting ACE and MST in other research interests have been discussed.


Assuntos
Eletroforese Capilar , Eletroforese Capilar/métodos , Ligação Proteica
4.
Electrophoresis ; 44(17-18): 1279-1341, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37537327

RESUMO

This review is in support of the development of selective, precise, fast, and validated capillary electrophoresis (CE) methods. It follows up a similar article from 1998, Wätzig H, Degenhardt M, Kunkel A. "Strategies for capillary electrophoresis: method development and validation for pharmaceutical and biological applications," pointing out which fundamentals are still valid and at the same time showing the enormous achievements in the last 25 years. The structures of both reviews are widely similar, in order to facilitate their simultaneous use. Focusing on pharmaceutical and biological applications, the successful use of CE is now demonstrated by more than 600 carefully selected references. Many of those are recent reviews; therefore, a significant overview about the field is provided. There are extra sections about sample pretreatment related to CE and microchip CE, and a completely revised section about method development for protein analytes and biomolecules in general. The general strategies for method development are summed up with regard to selectivity, efficiency, precision, analysis time, limit of detection, sample pretreatment requirements, and validation.


Assuntos
Eletroforese Capilar , Eletroforese em Microchip , Eletroforese Capilar/métodos , Proteínas , Preparações Farmacêuticas
5.
Electrophoresis ; 44(15-16): 1247-1257, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37079448

RESUMO

Capillary zone electrophoresis ultraviolet (CZE-UV) has become increasingly popular for the charge heterogeneity determination of mAbs and vaccines. The ε-aminocaproic acid (eACA) CZE-UV method has been used as a rapid platform method. However, in the last years, several issues have been observed, for example, loss in electrophoretic resolution or baseline drifts. Evaluating the role of eACA on the reported issues, various laboratories were requested to provide their routinely used eACA CZE-UV methods, and background electrolyte compositions. Although every laboratory claimed to use the He et al. eACA CZE-UV method, most methods actually deviate from He's. Subsequently, a detailed interlaboratory study was designed wherein two commercially available mAbs (Waters' Mass Check Standard mAb [pI 7] and NISTmAb [pI 9]) were provided to each laboratory, along with two detailed eACA CZE-UV protocols for a short-end, high-speed, and a long-end, high-resolution method. Ten laboratories participated each using their own instruments, and commodities, showing excellence method performance (relative standard deviations [RSDs] of percent time-corrected main peak areas from 0.2% to 1.9%, and RSDs of migration times from 0.7% to 1.8% [n = 50 per laboratory], analysis times in some cases as short as 2.5 min). This study clarified that eACA is not the main reason for the abovementioned variations.


Assuntos
Ácido Aminocaproico , Anticorpos Monoclonais , Anticorpos Monoclonais/análise , Eletroforese Capilar/métodos , Eletrólitos
6.
J Sep Sci ; 46(24): e2300516, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37884462

RESUMO

A new capillary zone electrophoresis method for collagen quantitation was developed and validated according to the International Council for Harmonization guideline Q2 (R1). The Sircol collagen assay and ultraviolet spectrometry were employed as reference methods. Capillary zone electrophoresis enables specific, simple, and fast determination within 9 min. It is less user-dependent and more automated than the Sircol collagen assay. With a limit of detection of 18.0 µg/mL, the new method is less sensitive than the Sircol collagen assay, which has a limit of detection of 6.5 µg/mL. Nonetheless, capillary zone electrophoresis covers a wider linearity range (50-400 µg/mL) compared to the Sircol collagen assay (5-80 µg/mL), with similar precision. Additional advantages of capillary zone electrophoresis are the ability to gain information on collagen integrity and to simultaneously determine native and denatured collagens. This approach represents a modern and legitimate alternative to the Sircol collagen assay. The developed method has been successfully applied to the study of three collagen products and samples from forced degradation.


Assuntos
Colágeno , Eletroforese Capilar , Eletroforese Capilar/métodos , Espectrofotometria Ultravioleta
7.
Electrophoresis ; 43(16-17): 1724-1734, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35704222

RESUMO

In this study, two capillary electrophoresis-based ligand binding assays, namely, mobility shift affinity capillary electrophoresis (ms-ACE) and capillary electrophoresis-frontal analysis (CE-FA), were applied to determine binding parameters of human serum albumin toward small drugs under similar experimental conditions. The substances S-amlodipine (S-AML), lidocaine (LDC), l-tryptophan (l-TRP), carbamazepine (CBZ), ibuprofen (IBU), and R-verapamil (R-VPM) were used as the main binding partners. The scope of this comparative study was to estimate and compare both the assays in terms of their primary measure's precision and the reproducibility of the derived binding parameters. The effective mobility could be measured with pooled CV values between 0.55% and 7.6%. The precision of the r values was found in the range between 1.5% and 10%. Both assays were not universally applicable. The CE-FA assay could successfully be applied to measure the drugs IBU, CBZ, and LDC, and the interaction toward CBZ, S-AML, l-TRP, and R-VPM could be determined using ms-ACE. The average variabilities of the estimated binding constants were 64% and 67% for CE-FA and ms-ACE, respectively.


Assuntos
Isotacoforese , Leucemia Mieloide Aguda , Eletroforese Capilar/métodos , Humanos , Ibuprofeno , Ligação Proteica , Reprodutibilidade dos Testes , Albumina Sérica Humana/metabolismo , Triptofano
8.
Electrophoresis ; 43(20): 1971-1983, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36004399

RESUMO

Two imaged capillary isoelectric focusing methods were developed to provide insight into the quality and stability of messenger ribonucleic acid (mRNA) vaccines, specifically, mRNA encapsulated in lipid nanoparticles (LNPs). A variety of stressed and lipid composition-modified samples were measured and detected by their UV absorption. The results were supported by the data of an encapsulation assay and particle sizing. One method, using 9 M urea as an additive, shows two broad and jagged peaks in which the peak shape offers detailed information. The summed peak area of both peaks showed RSDs from 2% to 8% when one batch was measured in triplicate and apparently depends on the size of the LNPs. In the second method, a combination of 5.5 M urea and 2 M N-ethylurea was used. This method is characterized by a high repeatability of the isoelectric point (pI, <0.5%). The repeatable peak area (RSD of 2%-7%) correlates linearly with the mRNA content, which also applies to the first method, and added stress is evident by the change in pI and peak area. Furthermore, experiments with the addition of a fluorescent dye were performed (fluorescence detection), which tremendously increased the sensitivity of the methods. Both methods can be used to characterize the stability of mRNA-loaded LNPs, for example, when investigating various storage times at different temperatures and freeze-thaw cycles, as well as the ability of the methods to distinguish lipid compositions and measure batch-to-batch variability.


Assuntos
Corantes Fluorescentes , Vacinas Sintéticas , Lipídeos , Lipossomos , Nanopartículas , RNA Mensageiro , Ureia , Vacinas de mRNA
9.
Electrophoresis ; 43(23-24): 2402-2427, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36285667

RESUMO

Nucleic acids are the blueprint of life. They are not only the construction plan of the single cell or higher associations of them, but also necessary for function, communication and regulation. Due to the pandemic, the attention shifted in particular to their therapeutic potential as a vaccine. As pharmaceutical oligonucleotides are unique in terms of their stability and application, special delivery systems were also considered. Oligonucleotide production systems can vary and depend on the feasibility, availability, price and intended application. To achieve good purity, reliable results and match the strict specifications in the pharmaceutical industry, the separation of oligonucleotides is always essential. Besides the separation required for production, additional and specifically different separation techniques are needed for analysis to determine if the product complies with the designated specifications. After a short introduction to ribonucleic acids (RNAs), messenger RNA vaccines, and their production and delivery systems, an overview regarding separation techniques will be provided. This not only emphasises electrophoretic separations but also includes spin columns, extractions, precipitations, magnetic nanoparticles and several chromatographic separation principles, such as ion exchange chromatography, ion-pair reversed-phase, size exclusion and affinity.


Assuntos
Ácidos Nucleicos , Oligonucleotídeos , Oligonucleotídeos/análise , Cromatografia por Troca Iônica/métodos , Cromatografia Líquida de Alta Pressão/métodos , Preparações Farmacêuticas
10.
Electrophoresis ; 43(9-10): 922-929, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34510488

RESUMO

The rapidly growing, competitive biopharmaceutical market requires tight bioprocess monitoring. An integrated, automated platform for the routine online/at-line monitoring of key factors in the cell culture medium could greatly improve process monitoring. Mono- and disaccharides, as the main energy and carbon source, are one of these key factors. A CE-LIF method was developed for the analysis of several mono- and disaccharides, considering requirements and restrictions for analysis in an integrated, automated monitoring platform, such as the possibility for miniaturization to microchip electrophoresis. Analysis was performed after fluorescent derivatization with 8-aminopyrene-1,3,6-trisulfonic acid. The derivatisation reaction and the separation BGE were optimized using design of experiments. The developed method is applicable to the complex matrix of cell culture medium and proved transferable to microchip electrophoresis.


Assuntos
Eletroforese em Microchip , Técnicas de Cultura de Células , Meios de Cultura , Dissacarídeos , Eletroforese Capilar/métodos , Miniaturização
11.
Anal Bioanal Chem ; 414(4): 1699-1712, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34870722

RESUMO

Two-dimensional separations provide a simple way to increase the resolution and peak capacity of complex protein separations. The feasibility of a recently developed instrumental approach for two-dimensional separations of proteins was evaluated. The approach is based on the general principle of two-dimensional gel electrophoresis. In the first dimension, semi-preparative strong anion exchange high-performance liquid chromatography is utilized and fractions are collected by means of a fraction collector. They are subsequently analyzed in the second dimension with microchip capillary electrophoresis sodium dodecyl sulfate. Microchip capillary electrophoresis provides the necessary speed (approximately 1 min/fraction) for short analysis. In this study, three different samples were investigated. Different constructs of soluble guanylyl cyclase were expressed in Sf9-cells using the baculovirus expression system. Cell lysates were analyzed and the resulting separations were compared. In our experimental setup, the soluble guanylyl cyclase was identified among hundreds of other proteins in these cell lysates, indicating its potential for screening, process control, or analysis. The results were validated by immunoblotting. Samples from Chinese hamster ovary cell culture before and after a purification step were investigated and approximately 9% less impurities could be observed. The separation patterns obtained for human plasma are closely similar to patterns obtained with two-dimensional gel electrophoresis and a total of 218 peaks could be observed. Overall, the approach was well applicable to all samples and, based on these results, further directions for improvements were identified. .


Assuntos
Cromatografia por Troca Iônica/instrumentação , Eletroforese Capilar/instrumentação , Proteínas/isolamento & purificação , Animais , Ânions/química , Células CHO , Cromatografia Líquida de Alta Pressão/instrumentação , Cricetulus , Humanos , Dodecilsulfato de Sódio/química
12.
Molecules ; 27(14)2022 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-35889479

RESUMO

The microscale thermophoresis (MST) technique was utilized to investigate lactoferrin-drug interaction with the iron chelator, deferiprone, using label-free system. MST depends on the intrinsic fluorescence of one interacting partner. The results indicated a significant interaction between lactoferrin and deferiprone. The estimated binding constant for the lactoferrin-deferiprone interaction was 8.9 × 10-6 ± 1.6, SD, which is to be reported for the first time. Such significant binding between lactoferrin and deferiprone may indicate the potentiation of the drug secretion into a lactating mother's milk. The technique showed a fast and simple approach to study protein-drug interaction while avoiding complicated labeling procedures. Moreover, the binding behavior of deferiprone within the binding sites of lactoferrin was investigated through molecular docking which reflected that deferiprone mediates strong hydrogen bonding with ARG121 and ASP297 in pocket 1 and forms H-bond and ionic interaction with ASN640 and ASP395, respectively, in pocket 2 of lactoferrin. Meanwhile, iron ions provide ionic interaction with deferiprone in both of the pockets. The molecular dynamic simulation further confirmed that the binding of deferiprone with lactoferrin brings conformational changes in lactoferrin that is more energetically stable. It also confirmed that deferiprone causes positive correlation motion in the interacting residues of both pockets, with strong negative correlation motion in the loop regions, and thus changes the dynamics of lactoferrin. The MM-GBSA based binding free energy calculation revealed that deferiprone exhibits ∆G TOTAL of -63,163 kcal/mol in pocket 1 and -63,073 kcal/mol in pocket 2 with complex receptor-ligand difference in pocket 1 and pocket 2 of -117.38 kcal/mol and -111.54 kcal/mol, respectively, which in turn suggests that deferiprone binds more strongly in the pocket 1. The free energy landscape of the lactoferrin-deferiprone complex also showed that this complex remains in a high energy state that confirms the strong binding of deferiprone with the lactoferrin. The current research concluded that iron-chelating drugs (deferiprone) can be transported from the mother to the infant in the milk because of the strong attachment with the lactoferrin active pockets.


Assuntos
Lactoferrina , Leite Humano , Deferiprona , Feminino , Humanos , Lactação , Simulação de Acoplamento Molecular , Simulação de Dinâmica Molecular
13.
Electrophoresis ; 42(6): 687-692, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33533060

RESUMO

In order to contribute to the scientific research on the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), we have investigated the isoelectric points (pI) of several related proteins, which are commercially available: the receptor-binding domain (RBD) with His- and Fc-tag, the S1 subunit with His-tag, the S1/S2 subunits with His-tag and the human angiotensin-converting enzyme 2 (hACE2) with His-tag. First, the theoretical pI values, based on the amino acid (AA) sequences of the proteins, were calculated using the ProtParam tool from the Bioinformatics Resource Portal ExPASy. The proteins were then measured with the Maurice imaged CIEF system (native fluorescence detection), testing various measurement conditions, such as different ampholytes or ampholyte mixtures. Due to isoforms, we get sections with several peaks and not just one peak for each protein. The determined pI range for the RBD/Fc is 8.24-9.32 (theoretical pI: 8.55), for the RBD/His it is 7.36-9.88 (8.91) and for the S1/His it is 7.30-8.37 (7.80). The pI range of the S1/S2/His is 4.41-5.87 (no theoretical pI, AA sequence unknown) and for hACE2/His, the determined global range is 5.19-6.11 (5.60) for all experimental conditions chosen. All theoretically derived values were found within these ranges, usually close to the center. Therefore, we consider theoretical values as useful to make predictions about the isoelectric points of SARS-CoV-2 proteins. The experimental conditions had only a minor influence on the pI ranges obtained and mainly influenced the peak shapes.


Assuntos
Enzima de Conversão de Angiotensina 2/química , COVID-19/virologia , Focalização Isoelétrica/métodos , SARS-CoV-2/química , Glicoproteína da Espícula de Coronavírus/química , Enzima de Conversão de Angiotensina 2/metabolismo , Sítios de Ligação , COVID-19/metabolismo , Humanos , Ponto Isoelétrico , Domínios e Motivos de Interação entre Proteínas , Subunidades Proteicas/química , Subunidades Proteicas/metabolismo , SARS-CoV-2/metabolismo , Glicoproteína da Espícula de Coronavírus/metabolismo
14.
Electrophoresis ; 42(3): 206-218, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33185281

RESUMO

The development of capillary electrophoresis, especially CE-SDS devices, has led CE-SDS to become an established tool in a wide range of applications in the analysis of biopharmaceuticals and is increasingly replacing its method of origin, SDS-PAGE. The goal of this study was to evaluate the comparability of molecular weight (MW) determination especially by CE-SDS and SDS-PAGE. For ensuring comparability, model proteins that have little or no posttranslational modifications and an IgG antibody were used. Only a minor influence of sample preparation conditions, including sample buffer, temperature conditions, and different reducing agents on the MW determination were found. In contrast, the selection of the MW marker plays a decisive role in determining the accurate apparent MW of a protein. When using different MW markers, the deviation in MW determination can exceed 10%. Interestingly, CE-SDS and 10% SDS-PAGE hardly differ in their trueness of MW determination. The trueness in relation to the reference MW for each protein was calculated. Although the trueness values for the model proteins considered range between 1.00 and 1.11 using CE-SDS, they range between 0.93 and 1.03 on SDS-PAGE, depending on the experimental conditions chosen.


Assuntos
Western Blotting/métodos , Eletroforese Capilar/métodos , Eletroforese em Gel de Poliacrilamida/métodos , Proteínas/análise , Proteínas/química , Animais , Humanos , Imunoglobulina G/análise , Imunoglobulina G/química , Modelos Lineares , Peso Molecular , Processamento de Proteína Pós-Traducional
15.
Electrophoresis ; 42(14-15): 1521-1531, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33956358

RESUMO

SDS gel electrophoresis is a commonly used approach for monitoring purity and apparent molecular mass (Mr) of proteins, especially in the field of quality control of biopharmaceutical proteins. The technological installation of CE-SDS as the replacement of the slab gel technique (SDS-PAGE) is still in progress, leading to a continuous improvement of CE-SDS instruments. Various CE-SDS instruments, namely Maurice (CE-SDS/CE-SDS PLUS) and Wes by ProteinSimple as well as the microchip gel electrophoresis system LabChip® GXII Touch™ HT by PerkinElmer were tested for precision and repeatability compared to SDS-PAGE (Bio-Rad). For assessing these quality control parameters, standard model proteins with minor post-translational modifications were used. Overall, it can be concluded that the CE-SDS-based methods are similar to SDS-PAGE with respect to these parameters. Quality characteristics of test systems gain more significance by testing proteins that do not behave like model proteins. Therefore, glycosylated proteins were analyzed to comparatively investigate the influence of glycosylation on Mr determination in the different instruments. In some cases, high deviations were found both among the methods and with regard to reference values. This article provides possible explanations for these findings.


Assuntos
Eletroforese Capilar , Eletroforese em Gel de Poliacrilamida , Eletroforese em Microchip , Glicosilação , Peso Molecular , Proteínas
16.
Electrophoresis ; 41(13-14): 1137-1151, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32469436

RESUMO

The material properties of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and its proteins are discussed. We review the viral structure, size, rigidity, lipophilicity, isoelectric point, buoyant density and centrifugation conditions, stability against pH, temperature, UV light, gamma radiation, and susceptibility to various chemical agents including solvents and detergents. Possible inactivation, downstream, and formulation conditions are given including suitable buffers and some first ideas for quality-control methods. This information supports vaccine development and discussion with competent authorities during vaccine approval and is certainly related to drug-targeting strategies and hygienics. Several instructive tables are given, including the pI and grand average of hydropathicity (GRAVY) of SARS-CoV-1 and -2 proteins in comparison. SARS-CoV-1 and SARS-CoV-2 are similar in many regards, so information can often be derived. Both are unusually stable, but sensitive at their lipophilic membranes. However, since seemingly small differences can have strong effects, for example, on immunologically relevant epitope settings, unevaluated knowledge transfer from SARS-CoV-1 to SARS-CoV-2 cannot be advised. Published knowledge regarding downstream processes, formulations and quality assuring methods is, as yet, limited. However, standard approaches employed for other viruses and vaccines seem to be feasible including virus inactivation, centrifugation conditions, and the use of adjuvants.


Assuntos
Betacoronavirus/química , Proteínas Virais/química , Vacinas Virais/farmacologia , Animais , Betacoronavirus/efeitos dos fármacos , Betacoronavirus/efeitos da radiação , Desinfetantes/farmacologia , Eletroforese , Temperatura Alta , Humanos , Concentração de Íons de Hidrogênio , Ponto Isoelétrico , SARS-CoV-2 , Raios Ultravioleta , Vacinas Atenuadas/imunologia , Vacinas Atenuadas/farmacologia , Vacinas Virais/imunologia , Inativação de Vírus/efeitos da radiação
17.
J Nanobiotechnology ; 18(1): 159, 2020 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-33158450

RESUMO

Purification of recombinant proteins is often a challenging matter because high purity and high recovery are desired. If the expressed recombinant protein is also in a complex matrix, such as from the silkworm expression system, purification becomes more challenging. Even if purification from the silkworm expression system is troublesome, it benefits from a high capacity for the production of recombinant proteins. In this study, magnetic nanoparticles (MNPs) were investigated as a suitable tool for the purification of proteins from the complex matrix of the silkworm fat body. The MNPs were modified with nickel so that they have an affinity for His-tagged proteins, as the MNP purification protocol itself does not need special equipment except for a magnet. Among the three different kinds of investigated MNPs, MNPs with sizes of 100 nm to 200 nm and approximately 20 nm-thick nickel shells were the most suitable for our purpose. With them, the total protein amount was reduced by up to at least approximately 77.7%, with a protein recovery of around 50.8% from the silkworm fat body. The minimum binding capacity was estimated to be 83.3 µg protein/mg MNP. Therefore, these MNPs are a promising tool as a purification pretreatment of complex sample matrices.


Assuntos
Bombyx/metabolismo , Cromatografia de Afinidade/métodos , Corpo Adiposo/química , Nanopartículas de Magnetita/química , Animais , Escherichia coli/genética , Magnetismo , Níquel , Fenômenos Físicos , Proteínas Recombinantes
18.
J Sep Sci ; 43(20): 3960-3968, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32823373

RESUMO

Mobility shift-affinity capillary electrophoresis was employed for enantioseparation and simultaneous binding constant determination. Human serum albumin was used as a chiral selector in the background electrolyte composed of 20 mM phosphate buffer, pH 7.4. The applied setup supports a high mobility shift since albumin and the drug-albumin complex hold negative net charges, while model compounds of amlodipine and verapamil are positively charged. In order to have an accurate effective mobility determination, the Haarhoff-van der Linde function was utilized. Subsequently, the association constant was determined by nonlinear regression analysis of the dependence of effective mobilities on the total protein concentration. Differences in the apparent binding status between the enantiomers lead to mobility shifts of different extends (α). This resulted in enantioresolutions of Rs = 1.05-3.63 for both drug models. R-(+)-Verapamil (KA 1844 M-1 ) proved to bind stronger to human serum albumin compared to S-(-)-verapamil (KA 6.6 M-1 ). The association constant of S-(-)-amlodipine (KA 25 073 M-1 ) was found to be slightly higher compared to its antipode (KA 22 620 M-1 ) when applying the racemic mixture. The low measurement uncertainty of this approach was demonstrated by the close agreement of the association constant of the enantiopure S-(-)-form (KA 25 101 M-1 ).


Assuntos
Anlodipino/química , Albumina Sérica Humana/química , Verapamil/química , Eletroforese Capilar , Humanos , Estrutura Molecular , Estereoisomerismo
19.
Electrophoresis ; 40(18-19): 2382-2389, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31177564

RESUMO

Capillary isoelectric focusing is indispensable for characterizing charge heterogeneity and isoelectric points of biopharmaceuticals. However, there are many influencing parameters and therefore method development is challenging. This study was performed to obtain an in-depth understanding of the imaged CIEF methodology by applying a design of experiments approach. To describe the parameter's effects as objectively as possible, a polynomial regression model was derived for the most important responses. For this purpose, the reference monoclonal antibody suggested by the National Institute of Standards and Technology (NISTmAb) was used as test molecule. The total concentration and the mixing ratio of two types of carrier ampholytes and the added amounts of urea and l-arginine were selected as factors. The effects of these factors on 13 different responses such as resolution or pI values were investigated. In order to reduce the total number of experiments, a d-optimal design with 20 different parameter combinations and six replicates each was chosen. The most significant effects of the four factors were shown for the parameters related to separation efficiency and peak position. In addition, the extent of the factor's effect could be assessed. Depending on the selected factor combination, the pI value can differ up to approximately 0.15 pI units and the resolution value between main peak and adjacent basic peak can range from approximately 1.6 to 2.5, for example.


Assuntos
Anticorpos Monoclonais/análise , Produtos Biológicos/análise , Eletroforese Capilar/métodos , Focalização Isoelétrica/métodos , Misturas Anfolíticas/química , Projetos de Pesquisa
20.
Electrophoresis ; 40(7): 1041-1054, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30637796

RESUMO

In all life sciences ligand binding assays (LBAs) play a crucial role. Unfortunately these are very error prone. One part of this uncertainty results from the unavoidable random measurement uncertainty, another part can be attributed to the experimental design. To investigate the latter, uncertainty propagation was evaluated as a function of the given experimental design. A design space including the normalized maximum response range (nMRR), the data point position (DPP), the data point range (DPR) and the number of data points (NoDP) was defined. Based on ten measured ms ACE source data sets 20 specific parameter sets were selected by Design of Experiments. Monte Carlo simulations using 100 000 repeats for every parameter set were employed. The resulting measurement uncertainty propagation factors (measurement uncertainty multiplier: MUM) were used to describe the whole design space by polynomial regression. The resulting 5-dimensional response surface was investigated to evaluate the design parameter's influence and to find the minimal uncertainty propagation. It could be shown, that the nMRR is of highest importance, followed by DPP and DPR. Interestingly, the NoDP is less relevant. However, the interactions of the four parameters need to be carefully considered during design optimization. Using at least five data points which cover over 40% of the upper part of the binding hyperbola (DPP > 0.57) the MUM will be minimized (MUM approximately 1.5) when the nMRR is appropriate. It is possible to reduce the measurement uncertainty propagation more than one order of magnitude.


Assuntos
Eletroforese Capilar/métodos , Eletroforese Capilar/estatística & dados numéricos , Ligantes , Incerteza , Algoritmos , Modelos Estatísticos , Método de Monte Carlo , Projetos de Pesquisa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA