Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Phys Chem Chem Phys ; 15(26): 10761-6, 2013 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-23689603

RESUMO

Metallic gold (Au) and platinum (Pt) thin films were deposited on silicon nanocones (Si-NCs) by sputtering to elucidate the effects of work function and conductivities on the field electron emission characteristics of surface-modified Si-NCs. The results showed that for Pt/Si-NCs and Au/Si-NCs, although the turn-on field defined at a corresponding current density of 10 µA cm(-2) only improved from 4.20 V µm(-1) for bare Si-NCs to 3.65 and 2.90 V µm(-1), respectively, the emission current density measured at 5.00 V µm(-1) was enhanced by orders of magnitude, reaching 1.82 mA cm(-2) for Au/Si-NCs. Compared to those obtained from various surface-modified Si-nanostructures, such as ZnO/Si-nanopillars and ferroelectrics/Si-nanotips, the current results represent an interesting alternative route for producing surface-modified Si-NCs that might be useful for optical and electronic applications.


Assuntos
Nanoestruturas/química , Silício/química , Ouro/química , Platina/química , Semicondutores , Propriedades de Superfície , Temperatura , Óxido de Zinco/química
2.
ACS Appl Mater Interfaces ; 14(17): 19795-19805, 2022 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-35417120

RESUMO

Highly sensitive X-ray detection is crucial in, for example, medical imaging and secure inspection. Halide perovskite X-ray detectors are promising candidates for detecting highly energetic radiation. In this report, we describe vacuum-deposited Cs-based perovskite X-ray detectors possessing a p-i-n architecture. Because of the built-in potential of the p-i-n structure, these perovskite X-ray detectors were capable of efficient charge collection and displayed an exceptionally high X-ray sensitivity (1.2 C Gyair-1 cm-3) under self-powered, zero-bias conditions. We ascribe the outstanding X-ray sensitivity of the vacuum-deposited CsPbI2Br devices to their prominent charge carrier mobility. Moreover, these devices functioned with a lowest detection limit of 25.69 nGyair s-1 and possessed excellent stability after exposure to over 3000 times the total dose of a chest X-ray image. For comparison, we also prepared traditional spin-coated CH3NH3-based perovskite devices having a similar device architecture. Their volume sensitivity was only one-fifth of that of the vacuum-deposited CsPbI2Br devices. Thus, all-vacuum deposition appears to be a new strategy for developing perovskite X-ray detectors; with a high practical deposition rate, a balance can be reached between the thickness of the absorbing layer and the fabrication time.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA