1.
MAGMA ; 36(3): 347-354, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37191776

RESUMO

Although there has been a resurgence of interest in low field magnetic resonance imaging (MRI) systems in recent years, low field MRI is not a new concept. FDA has a long history of evaluating the safety and effectiveness of MRI systems encompassing a wide range of field strengths. Many systems seeking marketing authorization today include new technological features (such as artificial intelligence), but this does not fundamentally change the regulatory paradigm for MR systems. In this review, we discuss some of the US regulatory considerations for low field magnetic resonance imaging (MRI) systems, including applicability of existing laws and regulations and how the U.S. Food and Drug Administration (FDA) evaluates low field MRI systems for market authorization. We also discuss regulatory considerations in the review of low field MRI systems incorporating novel AI technology. We foresee that MRI systems of all field strengths intended for general diagnostic use will continue to be evaluated for marketing clearance by the metric of substantial equivalence set forth in the premarket notification pathway.


Assuntos
Inteligência Artificial , Imageamento por Ressonância Magnética , Estados Unidos , United States Food and Drug Administration
2.
J Test Eval ; 48(1)2019 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-36147246

RESUMO

Personal protective equipment (PPE), such as gowns used in the latest Ebola outbreak in Western Africa, are critical in preventing the spread of deadly diseases. Appropriate test systems and test soils are needed to adequately evaluate PPE. ASTM F903, Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Liquid, has been used for decades to test fabrics' resistance to liquid penetration. However, this test apparatus requires at least 60 mL of test solutions, is labor intensive, and has problems with leakage around the gaskets. We compared the F903 test apparatus to a modified dot-blot apparatus to evaluate the visual penetration of a blood test soil. A series of commercially available gowns and drapes were tested in each apparatus. Using blood test soil at 2 psi, there was no statistically significant difference between the two methods except for in one gown. By comparing this gown in the ASTM test apparatus with and without a screen, the particular screen selected did not account for the difference between the dot-blot and F903 apparatuses; however, it is conceivable that a particular screen/fabric combination could account for this difference. The modified dot-blot apparatus was evaluated using three different test solutions: blood, vomit, and a labeled protein (goat anti-rabbit immunoglobulin G-horseradish peroxidase [GaR IgG-HRP]) in a blood test soil solution. This testing revealed significant difference in penetration for some of the PPE garments. The modified dot-blot had several large advantages over the ASTM apparatus-over six times less specimen volume and no edge or gasket leakage. In addition, nitrocellulose can be easily incorporated into the modified dot-blot apparatus, enabling the trapping of viruses and proteins that penetrate PPE-thus permitting the use of antibodies to quickly and sensitively detect penetration.

3.
Radiology ; 279(3): 906-9, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26599665

RESUMO

The U.S. Food and Drug Administration (FDA) continually works toward the goal of safety. For patients with magnetic resonance (MR) Conditional devices, safety is achieved when MR Conditional labeling is clear and accessible and can be unambiguously interpreted and applied. The FDA supports the three facets of standardization listed by the American College of Radiology (ACR) Subcommittee on MR Safety in their special report: (a) standardization in terminology and reporting of spatial gradient magnetic fields associated with MR systems; (b) standardization in reporting of ferromagnetic testing results for implants and devices; and (c) standardization, consistency, and clarity in radiofrequency power deposition guidelines and terminology. While the FDA is in agreement with the ACR Subcommittee on MR Safety that patient safety is of primary concern, the authors disagree with the Subcommittee on several important points and offer a point-by-point response to the Subcommittee's four recommendations. (©) RSNA, 2015.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Próteses e Implantes , Humanos , Imãs , Segurança do Paciente , Padrões de Referência , Estados Unidos
6.
J Magn Reson Imaging ; 37(3): 501-30, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23345200

RESUMO

Because there are many potential risks in the MR environment and reports of adverse incidents involving patients, equipment and personnel, the need for a guidance document on MR safe practices emerged. Initially published in 2002, the ACR MR Safe Practices Guidelines established de facto industry standards for safe and responsible practices in clinical and research MR environments. As the MR industry changes the document is reviewed, modified and updated. The most recent version will reflect these changes.


Assuntos
Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Radiologia/normas , Gestão da Segurança/normas , Adolescente , Criança , Meios de Contraste/efeitos adversos , Campos Eletromagnéticos , Feminino , Humanos , Masculino , Saúde Ocupacional , Segurança do Paciente , Gravidez , Complicações na Gravidez/prevenção & controle , Radiologia/métodos , Risco , Temperatura , Estados Unidos
8.
J Biomed Mater Res B Appl Biomater ; 106(2): 854-862, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28419752

RESUMO

INTRODUCTION: Current mechanical testing of surgical mesh focuses primarily on tensile properties even though implanted devices are not subjected to pure tensile loads. Our objective was to determine the flexural (bending) properties of surgical mesh and determine if they correlate with mesh tensile properties. METHODS: The flexural rigidity values of 11 different surgical mesh designs were determined along three textile directions (machine, cross-machine, and 45° to machine; n = 5 for each) using ASTM D1388-14 while tracking surface orientation. Tensile testing was also performed on the same specimens using ASTM D882-12. Linear regressions were performed to compare mesh flexural rigidity to mesh thickness, areal mass density, filament diameter, ultimate tensile strength, and maximum extension. RESULTS: Of 33 mesh specimen groups, 30 had significant differences in flexural rigidity values when comparing surface orientations (top and bottom). Flexural rigidity and mesh tensile properties also varied with textile direction (machine and cross-machine). There was no strong correlation between the flexural and tensile properties, with mesh thickness having the best overall correlation with flexural rigidity. CONCLUSIONS: Currently, surface orientation is not indicated on marketed surgical mesh, and a single mesh may behave differently depending on the direction of loading. The lack of correlation between flexural stiffness and tensile properties indicates the need to examine mesh bending stiffness to provide a more comprehensive understanding of surgical mesh mechanical behaviors. Further investigation is needed to determine if these flexural properties result in the surgical mesh behaving mechanically different depending on implantation direction. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 854-862, 2018.


Assuntos
Teste de Materiais , Telas Cirúrgicas , Resistência à Tração , Propriedades de Superfície
9.
J Biomed Mater Res B Appl Biomater ; 72(1): 186-90, 2005 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-15449256

RESUMO

It has been recommended by the World Health Organization (WHO) and Centers for Disease Control and Prevention (CDC) that rigorous decontamination protocols be used on surgical instruments that have been exposed to tissue possibly contaminated with Creutzfeldt-Jakob disease (CJD). This study was designed to examine the effects of these protocols on various types of surgical instruments. The most important conclusions are: (1) autoclaving in 1N NaOH will cause darkening of some instruments; (2) soaking in 1N NaOH at room temperature damages carbon steel but not stainless steel or titanium; (3) soaking in chlorine bleach will badly corrode gold-plated instruments and will damage some, but not all, stainless-steel instruments, especially welded and soldered joints. Damage became apparent after the first exposure and therefore long tests are not necessary to establish which instruments will be damaged.


Assuntos
Descontaminação/métodos , Descontaminação/normas , Doenças Priônicas/prevenção & controle , Organização Mundial da Saúde , Animais , Bovinos , Corrosão , Descontaminação/legislação & jurisprudência , Eletrodos , Humanos , Doenças Priônicas/transmissão , Ovinos , Instrumentos Cirúrgicos/normas
11.
J Biomed Mater Res B Appl Biomater ; 66(2): 548-52, 2003 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-12861606

RESUMO

Ethylene oxide (EO) gas is commonly used to sterilize medical devices. The amount of residual EO remaining in a device depends partly on the type and size of polymeric material. A major concern is the amount of residue that may be available in the body. With the use of the method described by AAMI for headspace analysis of EO residues, different polymers and medical devices subjected to different numbers of sterilization cycles were examined. Next, the effect of various extraction conditions and extraction solutions on these polymers and medical devices was evaluated. The results showed different polymers desorb EO differently. One polyurethane (PU 75D) had much higher EO residue than a different polyurethane (PU 80A). Repeated extraction of the PU 75D was necessary to quantify total EO residue levels. Different extraction solutions influence the amount and reproducibility of EO detected, whereas multiple resterilizations showed no difference in amount of residual EO. Bioavailability of EO was estimated by extracting the devices and polymers in water. Comparison of total EO residues to EO that was bioavailable showed no difference for some polymers and devices, while others had an almost eightfold difference. Some standard biocompatibility tests were run on extracts and devices, but no significant effects were observed.


Assuntos
Desinfetantes/análise , Equipamentos e Provisões , Óxido de Etileno/análise , Polímeros/química , Poliuretanos/química , Materiais Biocompatíveis , Disponibilidade Biológica , Contaminação de Equipamentos , Reutilização de Equipamento , Óxido de Etileno/toxicidade , Humanos , Teste de Materiais , Esterilização/métodos
12.
Biomed Instrum Technol ; 36(1): 23-7, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-11831098

RESUMO

Driven by economic and time constraints, some medical centers and third parties are resterilizing single-use devices (SUDs) for reuse. The steam autoclave is quick, but most plastics used in SUDs cannot survive the temperature. Thus, a number of new methods of cleaning, disinfecting, and sterilizing these complex devices are being introduced on the market. The present study investigated the effects of a range of methods on the tensile strength of latex rubber, silicone elastomer, 2 different formulations of polyurethane, nylon, and high-density polyethylene (HDPE) specimens. The methods used were sodium hypochlorite bleach (Clorox), peracetic acid + hydrogen peroxide (Steris), formaldehyde gas (Chemiclave), low-temperature peracetic acid and gas plasma (Plazlyte), and low-temperature hydrogen peroxide gas plasma (Sterrad). The results showed that silicone elastomer was minimally affected, whereas the strengths of nylon, polyethylene, and latex were reduced by some of the methods. Depending on the formulation, the strength of polyurethane either increased or decreased. The data demonstrated that disinfection and sterilization can affect the tensile strength of certain materials used in medical devices.


Assuntos
Desinfecção/métodos , Equipamentos Descartáveis , Teste de Materiais/métodos , Plásticos/química , Esterilização/métodos , Desinfecção/tendências , Elastômeros/química , Análise de Falha de Equipamento , Gases/química , Humanos , Hipoclorito de Sódio/química , Esterilização/tendências , Resistência à Tração , Fatores de Tempo
13.
J Magn Reson Imaging ; 26(5): 1186-9, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17969160

RESUMO

The purpose of this review is to define the current standards addressing safety of medical devices in MRI and to describe ongoing standards development efforts. The American Society for Testing and Materials (ASTM International) began developing standard test methods for determining the MR safety of medical devices in MRI in 1997. To date, five ASTM standards addressing testing and marking medical devices and other items for use in the MR environment have been published. International Standards Organization (ISO) 14630, the general requirements standard for nonactive surgical implants, is currently being revised to include information about MR safety of passive implants and to reference the ASTM standards. To address the unique safety issues of active implants, and in particular, active implants with leads, like pacemakers and neurostimulators, a joint working group between ISO TC150/SC6 on active implants and International Electrotechnical Commission (IEC) SC 62B MT40 on magnetic resonance equipment for medical diagnosis is working to develop a technical specification for active implantable medical devices (AIMDs) in MRI. While much progress has been made, work still needs to continue to develop a complete body of test methods to allow the evaluation of the safety of medical devices in the MR environment.


Assuntos
Análise de Falha de Equipamento/normas , Segurança de Equipamentos/normas , Segurança de Equipamentos/tendências , Equipamentos e Provisões/normas , Guias como Assunto , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/normas , Previsões , Internacionalidade , Padrões de Referência , Estados Unidos