Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Sensors (Basel) ; 24(17)2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-39275601

RESUMO

The detection of dimethyl sulphide (DMS) at levels between ppb and ppm is a significant area of research due to the necessity of monitoring the presence of this gas in a variety of environments. These include environmental protection, industrial safety and medical diagnostics. Issues related to certain uncertainties concerning the influence of high humidity on DMS measurements with resistive gas sensors, e.g., in the detection of this marker in exhaled air, of the still unsatisfactory lower detection limit of DMS are the subject of intensive research. This paper presents the results of modifying the composition of the ZnO-based sensor layer to develop a DMS sensor with higher sensitivity and lower detection limit (LOD). Improved performance was achieved by using ZnO in the form of hexagonal nano- and microplates doped with gold nanoparticles (0.75 wt.%) and by using a well-proven sepiolite-based passive filter. The modification of the layer composition with respect to the authors' previous studies contributed to the development of a sensor that is highly sensitive to 1 ppm DMS (S = 11.4) and achieves an LOD of up to 406 ppb, despite the presence of a high water vapour content (90% RH) in the analysed atmosphere.

2.
Sensors (Basel) ; 24(5)2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38475240

RESUMO

Frequency-selective surfaces (FSS) are two-dimensional geometric structures made of conductive materials that selectively transmit or reflect electromagnetic waves. In this paper, flexible FSS made on textile and film substrates is presented and compared to show the effect of the texture associated with the type of substrate on the shielding properties. Three geometries of patterns of squares in the border, inversion of squares in the border, and circles with a border were used, and the patterns were made by the silver paste screen printing technique. Microscopic analysis (SEM and optical) was performed to determine the degree of substrate coverage and the actual geometry of the pattern. The resistance per square of the obtained patterns was about 50 mΩ/□. The shielding properties of FSS were simulated in Comsol Multiphysics 6.2 software and then measured by the antenna method. Selective textile filters were obtained, depending on the pattern used, with one or two modals with a transmission attenuation of about 15 dB. The paper analyzes the effect of the substrate and the screen printing technique used on the shielding properties of the flexible FSS.

3.
Int J Mol Sci ; 24(6)2023 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-36982889

RESUMO

MicroRNAs (miRNAs) are currently investigated as crucial regulatory factors which may serve as a potential therapeutic target. Reports on the role of miRNA in patients with coronary artery aneurysmal disease (CAAD) are limited. The present analysis aims to confirm the differences in the expression of previously preselected miRNAs in larger study groups and evaluate their usefulness as potential markers of CAAD. The study cohort included 35 consecutive patients with CAAD (Group 1), and two groups of 35 patients matched Group 1 regarding sex and age from the overall cohort of 250 patients (Group 2 and Group 3). Group 2 included patients with angiographically documented coronary artery disease (CAD), while Group 3 enrolled patients with normal coronary arteries (NCA) assessed during coronary angiography. We applied the RT-qPCR method using the custom plates for the RT-qPCR array. We confirmed that the level of five preselected circulating miRNAs was different in patients with CAAD compared to Group 2 and Group 3. We found that miR-451a and miR-328 significantly improved the CAAD prediction. In conclusion, miR-451a is a significant marker of CAAD compared to patients with CAD. In turn, miR-328-3p is a significant marker of CAAD compared to patients with NCA.


Assuntos
MicroRNA Circulante , Doença da Artéria Coronariana , MicroRNAs , Humanos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/genética , MicroRNA Circulante/genética , MicroRNAs/genética , Angiografia Coronária , Biomarcadores
4.
Sensors (Basel) ; 22(3)2022 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-35161678

RESUMO

The electric properties and chemical and thermal stability of gallium oxide ß-Ga2O3 make it a promising material for a wide variety of electronic devices, including chemiresistive gas sensors. However, p-type doping of ß-Ga2O3 still remains a challenge. A ß-Ga2O3 epitaxial layer with a highly developed surface was synthesized on gold electrodes on a Al2O3 substrate via a Halide Vapor Phase Epitaxy (HVPE) method. The epitaxial layer was impregnated with an aqueous colloidal solution of gold nanoparticles with an average diameter of Au nanoparticle less than 5 nm. Electrical impedance of the layer was measured before and after modification with the Au nanoparticles in an ambient atmosphere, in dry nitrogen, and in air containing dimethyl sulfide C2H6S (DMS). After the impregnation of the ß-Ga2O3 epitaxial layer with Au nanoparticles, its conductance increased, and its electric response to air containing DMS had been inversed. The introduction of Au nanoparticles at the surface of the metal oxide was responsible for the formation of an internal depleted region and p-type conductivity at the surface.

5.
Sensors (Basel) ; 20(23)2020 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-33291379

RESUMO

In this article, we present results concerning the impact of structural and chemical properties of zinc oxide in various morphological forms and its gas-sensitive properties, tested in an atmosphere containing a very aggressive gas such as chlorine. The aim of this research was to understand the mechanism of chlorine detection using a resistive gas sensor with an active layer made of zinc oxide with a different structure and morphology. Two types of ZnO sensor layers obtained by two different technological methods were used in sensor construction. Their morphology, crystal structure, specific surface area, porosity, surface chemistry and structural defects were characterized, and then compared with gas-sensitive properties in a chlorine-containing atmosphere. To achieve this goal, scanning electron microscopy (SEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and photoluminescence spectroscopy (PL) methods were used. The sensing properties of obtained active layers were tested by the temperature stimulated conductance method (TSC). We have noticed that their response in a chlorine atmosphere is not determined by the size of the specific surface or porosity. The obtained results showed that the structural defects of ZnO crystals play the most important role in chlorine detection. We demonstrated that Cl2 adsorption is a concurrent process to oxygen adsorption. Both of them occur on the same active species (oxygen vacancies). Their concentration is higher on the side planes of the zinc oxide crystal than the others. Additionally, ZnO sublimation process plays an important role in the chlorine detection mechanism.

6.
Sensors (Basel) ; 16(11)2016 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-27834879

RESUMO

The article presents the results of the detection of low-concentration C1-C4 alcohols using a planar sensor, in which a sepiolite filter was applied next to the gas-sensitive layer based on tin dioxide. The sepiolite layer is composed of tubes that have a length of several microns, and the diameter of the single tube ranges from several to tens of nanometers. The sepiolite layer itself demonstrated no chemical activity in the presence of volatile organic compounds (VOC), and the passive filter made of this material did not modify the chemical composition of the gaseous atmosphere diffusing to the gas-sensitive layer. The test results revealed that the structural remodelling of the sepiolite that occurs under the influence of temperature, as well as the effect of the filter (a compound with ionic bonds) with molecules of water, has a significant impact on the improvement of the sensitivity of the sensor in relation to volatile organic compounds when compared to the sensor without a filter.

7.
Sensors (Basel) ; 14(11): 20480-99, 2014 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-25360578

RESUMO

The main objective of the paper was the analysis of the properties of SnO2|WO3 heterocontact as well as the determination of its response to 50 ppm of hydrogen sulphide. It was noticed that the sensitivity of the sensor being tested to hydrogen sulphide depended significantly on the polarization direction. When its parameters were compared with those of sensors the gas-sensitive layer of which was made only from one type of metal oxide, a high impact of the heterocontact on the electric charge transport was noticed. The value of the activation energy of the electric conductivity is clearly dependent on the polarization direction. A mechanism of physicochemical processes occurring in a planar sensor with a heterocontact was suggested, and three areas differing in the width of depleted layer, where the inter-phase boundary of SnO2|WO3 had the most essential impact on the parameters of the sensor being tested, were distinguished and described.

8.
Int J Cardiol ; 415: 132436, 2024 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-39153511

RESUMO

INTRODUCTION: Percutaneous coronary intervention (PCI) with drug-eluting stents (DES) in complex coronary artery disease (CAD) has been established as the standard of care, but stent-related events are not uncommon. Sirolimus-Coated Balloon (SCB)-based angioplasty is an emerging technology, although it needs to be thoroughly evaluated compared with DES in the complex PCI setting. This study aimed to investigate the safety and efficacy of SCB-based angioplasty compared with new-generation DES in complex PCI. METHODS: Net adverse cardiovascular events (NACE: all-cause death, target lesion revascularization, non-fatal myocardial infarction, and major bleedings according to BARC classification), as a primary study endpoint was compared between SCB and new-generation DES for complex coronary lesions. RESULTS: Among 1782 patients with complex CAD, 1076 were treated with a sirolimus-coated balloon (EASTBOURNE Registry) and 706 with new-generation DES (COMPLEX Registry). After propensity score matching, a total of 512 patients in both groups were analyzed. NACE occurred more significantly in the DES group during the 1-year follow-up (10.5% vs. 3.9%, p = 0.003), mainly due to a higher risk of bleeding (6.6% vs. 0.4%, p = 0.001). The Cox model adjusted for lesion length showed a significantly lower hazard of NACE (HR: 0.23, CI [0.10, 0.52], p < 0.001) and all-cause mortality (HR: 0.07, CI [0.01, 0.66], p = 0.020) in SCB compared to DES group. CONCLUSIONS: SCB angioplasty has an advantage over DES for the treatment of complex CAD regarding NACE, significantly reducing the incidence of major bleeding without increasing ischemic endpoints. SCB may be an alternative to DES in selected patients with complex coronary lesions.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Stents Farmacológicos , Pontuação de Propensão , Sirolimo , Humanos , Sirolimo/administração & dosagem , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/diagnóstico por imagem , Angioplastia Coronária com Balão/métodos , Angioplastia Coronária com Balão/instrumentação , Angioplastia Coronária com Balão/efeitos adversos , Sistema de Registros , Seguimentos , Resultado do Tratamento , Materiais Revestidos Biocompatíveis
9.
Przegl Lek ; 70(6): 386-91, 2013.
Artigo em Polonês | MEDLINE | ID: mdl-24052975

RESUMO

Synthetic beta-cathinone derivatives belong to the novel group of psychostimulant "designer drugs". They show significant structural similarity to catecholamines and exogenous central nervous system (CNS) stimulating agents such as amphetamine, methamphetamine, ephedrine, 3,4-methylenedioxy-N-methylamphetamine (MDMA, ecstasy), and act as dopamine, noradrenaline and serotonin reuptake inhibitors. Popular synthetic beta-cathinones include e.g. mephedrone (4-methylmethcathinone, 4-MMC), naphyrone (naphthylpyrovalerone) and MDPV (3,4-methylenedioxypyrovalerone). Ingestion of synthetic cathinones produces effects of CNS stimulation, often comparable to those evoked by cocaine, amphetamine and MDMA. Chronic abuse of beta-cathinone derivatives leads to the development of tolerance, psychic and physical dependence. This paper discusses pharmacological properties of the most commonly used beta-cathinone derivatives as well as risks associated with their abuse. Special emphasis is given to neurological, psychiatric, cardiovascular and hematologic disturbances. Authors also present cases of fatalities caused by acute beta-cathinone intoxication or resulting from the drug-related accidents and crimes.


Assuntos
Alcaloides/química , Alcaloides/intoxicação , Estimulantes do Sistema Nervoso Central/intoxicação , Drogas Desenhadas/intoxicação , Psicotrópicos/intoxicação , Transtornos Relacionados ao Uso de Substâncias/etiologia , Alcaloides/síntese química , Doenças Cardiovasculares/induzido quimicamente , Estimulantes do Sistema Nervoso Central/síntese química , Estimulantes do Sistema Nervoso Central/química , Drogas Desenhadas/síntese química , Drogas Desenhadas/química , Doenças Hematológicas/induzido quimicamente , Humanos , Transtornos Mentais/induzido quimicamente , Doenças do Sistema Nervoso/induzido quimicamente , Psicotrópicos/síntese química , Transtornos Relacionados ao Uso de Substâncias/mortalidade
10.
J Clin Med ; 12(5)2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36902751

RESUMO

The authors present a new paper examining the disturbances in ocular circulation and electrophysiological changes in the presence of neuro-ophthalmic manifestations in a patient with cerebral autosomal dominant arteriopathy with subcortical infracts and leucoencephalopathy (CADASIL). Symptoms reported by the patient included: transient vision loss (TVL), migraines, diplopia, bilateral peripheral visual field loss and convergence insufficiency. CADASIL was confirmed by the presence of NOTCH3 gene mutation (p.Cys212Gly), the presence of granular osmiophilic material (GOM) in cutaneous vessels in an immunohistochemistry test (IHC) and bilateral focal vasogenic lesions in the white matter of the cerebral hemisphere, with micro-focal infarct in the left external capsule on a magnetic resonance imaging test (MRI). Color Doppler imaging (CDI) confirmed decreased blood flow and increased vascular resistance in the retinal and posterior ciliary arteries, with reduced P50 wave amplitude on a pattern electroretinogram (PERG). An eye fundus examination and fluorescein angiography (FA) revealed the constriction of retinal vessels and a peripheral retinal pigment epithelium (RPE) atrophy with focal drusen. The authors suggest that the cause of TVL may be changes in the hemodynamics of the retinochoroid vessels associated with the narrowing of small vessels and the presence of druses in the retina-which is supported by a decrease in the amplitude of the P50 wave in PERG, changes in OCT correlating simultaneously with changes in MRI imaging and other neurological symptoms.

11.
J Pers Med ; 13(6)2023 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-37373885

RESUMO

Cardiological and oncological patients comprise the majority of patients admitted to the emergency unit with chronic or acute conditions that are the dominant cause of death worldwide. However, electrotherapy and implantable devices (pacemakers and cardioverters) improve the prognosis of cardiological patients. We present the case report of a patient who, in the past, had a pacemaker implanted due to symptomatic sick sinus syndrome (SSS) without removing the two remaining leads. Echocardiography revealed severe tricuspid valve regurgitation. The tricuspid valve septal cusp was in a restricting position due to the two ventricular leads passing through the valve. A few years later, she was diagnosed with breast cancer. We present a 65-year-old female admitted to the department due to right ventricular failure. The patient manifested symptoms of right heart failure, predominated by ascites and lower extremity edema, despite increasing doses of diuretics. The patient underwent a mastectomy two years ago due to breast cancer and was qualified for thorax radiotherapy. A new pacemaker system was implanted in the right subclavian area as the pacemaker generator occupied the radiotherapy field. In the case of right ventricular lead removal and the need for pacing and resynchronization therapy, guidelines allow a coronary sinus for LV pacing to avoid passing the leads through the tricuspid valve. We facilitated this approach in our patient, suggesting that the percentage of ventricular pacing was very low.

12.
J Clin Med ; 12(20)2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-37892644

RESUMO

Lymphomas are a group of malignant tumors that originate in the lymphatic system. It is the most common type of blood cancer. It affects the lymph nodes, spleen, bone marrow, blood, and other organs. They can be aggressive or chronic. Hodgkin lymphoma survival rate is 2 in 100,000 people. Young adults aged 20-30 and people over 50 are most often affected. The prognosis of Hodgkin's lymphoma is good, with a survival rate of up to 80 percent. Nevertheless, in 20-30 percent of patients who initially respond to treatment, the disease has a tendency to progress. The positive effect of radiotherapy (RT) on patients' survival rates has been proven in many randomized clinical trials. Although the dose of chest RT has significantly reduced over the years, we still struggle with the long-term complications of post-RT repercussions, mainly because there is no established safe dose of RT affecting the heart. Other complications include earlier onset of coronary artery disease, early and late onset of pericarditis, valve degeneration (predominantly of the left heart), calcification of the aorta and its branches, heart failure, and arrhythmias. One patient can manifest each of the abovementioned complications, as in the present case. That is why choosing the right treatment strategy is crucial.

13.
Pharmaceuticals (Basel) ; 16(9)2023 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-37765060

RESUMO

Pulmonary hypertension (PH) is a severe vascular complication of connective tissue diseases (CTD). Patients with CTD may develop PH belonging to diverse groups: (1) pulmonary arterial hypertension (PAH), (2) PH due to left heart disease, (3) secondary PH due to lung disease and/or hypoxia and (4) chronic thromboembolic pulmonary hypertension (CTEPH). PAH most often develops in systemic scleroderma (SSc), mostly in its limited variant. PAH-CTD is a progressive disease characterized by poor prognosis. Therefore, early diagnosis should be established. A specific treatment for PAH-CTD is currently available and recommended: prostacyclin derivative (treprostinil, epoprostenol, iloprost, selexipag), nitric oxide and natriuretic pathway: stimulators of soluble guanylate cyclase (sGC: riociguat) and phosphodiesterase-five inhibitors (PDE5i: sildenafil, tadalafil), endothelin receptor antagonists (ERA: bosentan, macitentan, ambrisentan). Moreover, novel drugs, e.g., sotatercept, have been intensively investigated in clinical trials. We aim to review the literature on recent advances in the treatment strategy and prognosis of patients with PAH-CTD. In this manuscript, we discuss the mechanism of action of PAH-specific drugs and new agents and the latest research conducted on PAH-CTD patients.

14.
High Blood Press Cardiovasc Prev ; 30(1): 29-36, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36396904

RESUMO

INTRODUCTION: 2018 ESC/ESH guidelines have recommended 24-h ambulatory blood pressure monitoring to assess hypotensive therapy in many circumstances. Recommended target blood pressure in office blood pressure measurements is between 120/70 and 130/80 mmHg. Such targets for 24-h ambulatory blood pressure monitoring lacks. AIM: We aimed to define target values of blood pressure in 24-h ambulatory blood pressure monitoring in hypertensive patients. METHODS: Office blood pressure measurements and 24-h ambulatory blood pressure monitoring data were collected from 1313 hypertensive patients and sorted following increasing systolic (SBP)/diastolic (DBP) blood pressure in office blood pressure measurements. The corresponding 24-h ambulatory blood pressure monitoring to office blood pressure measurements values were calculated. RESULTS: Values 130/80 mmHg in office blood pressure measurements correspond in 24-h ambulatory blood pressure monitoring: night-time SBP/DBP mean: 113.74/66.95 mmHg; daytime SBP/DBP mean: 135.02/81.78 mmHg and 24-h SBP/DBP mean: 130.24/78.73 mmHg. Values 120/70 mmHg in office blood pressure measurements correspond in 24-h ambulatory blood pressure monitoring: night-time SBP/DBP mean: 109.50/63.43 mmHg; daytime SBP/DBP mean: 131.01/78.47 mmHg and 24-h SBP/DBP mean: 126.36/75.31 mmHg. CONCLUSIONS: The proposed blood pressure target values in 24-h ambulatory blood pressure monitoring complement the therapeutic target indicated in the ESC/ESH recommendations and improves 24-h ambulatory blood pressure monitoring usefulness in clinical practice.


Assuntos
Monitorização Ambulatorial da Pressão Arterial , Hipertensão , Humanos , Pressão Sanguínea , Hipertensão/diagnóstico , Hipertensão/tratamento farmacológico , Determinação da Pressão Arterial
15.
J Pers Med ; 13(5)2023 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-37241008

RESUMO

Transcatheter aortic valve implantation (TAVI) is currently becoming the method of choice in high-risk patients with severe aortic valve stenosis. Post-TAVI complications are more common owing to the increasing use of the method. The majority of TAVI complications derive from concomitant aortic stenosis with moderate/severe aortic insufficiency, paravalvular leak, and atrioventricular block. The contemporary TAVI qualification process includes a thorough echocardiography and angio-CT of the aorta, which is crucial in assessing valve measurements, determining the position of the coronary arteries branching from the aorta, and choosing the optimal valve size. We present the case report of an 81-year-old patient admitted to our hospital because of exacerbation of the clinical condition and development of pulmonary edema a few days after TAVI. Despite the reduction of the initial leak, an echocardiographic examination revealed the remaining severe paravalvular aortic leakage. We performed open-heart cardio-thoracic surgery, explanted the TAVI valve, and implanted the biological prosthesis (Edwards Perimount Magna size 25). Introduction of new interventional treatment approaches and the availability of imaging tools have substantially reduced the incidence of significant paravalvular leak and offered a better prognosis for patients undergoing TAVI.

16.
J Clin Med ; 12(11)2023 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-37298033

RESUMO

Although the treatment and prognosis of patients after heart transplantation have significantly improved, late graft dysfunction remains a critical problem. Two main subtypes of late graft dysfunction are currently described: acute allograft rejection and cardiac allograft vasculopathy, and microvascular dysfunction appears to be the first stage of both. Studies revealed that coronary microcirculation dysfunction, assessed by invasive methods in the early post-transplant period, correlates with a higher risk of late graft dysfunction and death during long-term follow-up. The index of microcirculatory resistance, measured early after heart transplantation, might identify the patients at higher risk of acute cellular rejection and major adverse cardiovascular events. It may also allow optimization and enhancement of post-transplantation management. Moreover, cardiac allograft vasculopathy is an independent prognostic factor for transplant rejection and survival rate. The studies showed that the index of microcirculatory resistance correlates with anatomic changes and reflects the deteriorating physiology of the epicardial arteries. In conclusion, invasive assessment of the coronary microcirculation, including the measurement of the microcirculatory resistance index, is a promising approach to predict graft dysfunction, especially the acute allograft rejection subtype, during the first year after heart transplantation. However, further advanced studies are needed to fully grasp the importance of microcirculatory dysfunction in patients after heart transplantation.

17.
Postepy Kardiol Interwencyjnej ; 18(3): 192-200, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36751279

RESUMO

Myocardial infarction with non-obstructive coronary arteries (MINOCA) is a working diagnosis and requires identification of the underlying causes to optimize treatment, improve prognosis, and prevent the recurrence of myocardial infarction. According to the literature, the prognosis of patients diagnosed with MINOCA is comparable to the group of patients with myocardial infarction (MI) and significant stenosis of the coronary arteries. Intracoronary imaging is a crucial diagnostic tool used in identifying epicardial causes of MINOCA that are not visible in coronary angiography. Optical coherence tomography (OCT) provides the highest spatial resolution, simultaneously allowing detailed visualization of plaque pathology in individuals with MINOCA and identifying the cause of MI in up to 80% of patients. Common causes of a MINOCA may include plaque disruption, spontaneous coronary artery dissection (SCAD), coronary artery spasm, and coronary thromboembolism. The optimization of pharmacological treatment in this group of patients, especially dual antiplatelet therapy and statins, improves the prognosis. Data on the indications for invasive treatment of patients with MINOCA based on OCT findings are insufficient. There is a strong need for research comparing treatment strategies, especially in high-risk lesions visualized in OCT. The main aim of this review is to demonstrate the usefulness of OCT in determining the mechanism of MINOCA.

18.
Ginekol Pol ; 93(11): 922-929, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35325456

RESUMO

OBJECTIVES: The aim of the study was to compare the perinatal outcome between the normal weight, overweight and obese pregnant women who delivered in the third-level center of reference. Moreover, the objective was to analyze the usefulness of predelivery body mass index (BMI) in prediction of preterm delivery, prolonged second stage of labor, instrumental vaginal delivery, cesarean section, fetal macrosomia, dystocia and newborn acidosis. MATERIAL AND METHODS: The retrospective study included 2104 patients, divided into three groups, with BMI between 18.5 and 24.9; 25.0 and 29.9; higher than or equal 30.0 kg/m2, respectively. The data were assessed from the medical history. RESULTS: The predelivery obesity increases the risk of cesarean section (aOR 1.63), macrosomia (aOR 8.89) and dystocia (aOR 3.40) in comparison to normal weight women. Moreover, the obese females had three times greater risk of having a macrosomic child (aOR 3.57) and 1.5 times greater risk of cesarean section (aOR 1.52) than overweight group. The role of predelivery BMI in the prediction of cesarean delivery (AUC 0.550; sensitivity 0.39; specificity 0.71, p < 0.001, cut-off value 28.7 kg/m2), macrosomia (AUC 0.714; sensitivity 0.66; specificity 0.70; p < 0.001, cut-off value 29.0 kg/m2) and dystocia (AUC 0.658; sensitivity 0.77; specificity 0.53, p < 0.001, cut-off value 27.0 kg/m2) was significant. CONCLUSIONS: The predelivery obesity increases the risk of cesarean section, macrosomia and shoulder dystocia and is a useful parameter in the prediction of perinatal outcomes. The establishing cut-off value for predelivery BMI was the lowest in prediction of shoulder dystocia.


Assuntos
Distocia , Trabalho de Parto , Distocia do Ombro , Recém-Nascido , Criança , Gravidez , Feminino , Humanos , Macrossomia Fetal/diagnóstico , Cesárea , Índice de Massa Corporal , Sobrepeso , Estudos Retrospectivos , Obesidade/complicações , Aumento de Peso , Distocia/diagnóstico
19.
Animals (Basel) ; 12(1)2021 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-35011175

RESUMO

Poland is the only European country where the Osprey population is declining due to the mortality of adult birds from poaching, which impacts not only single breeding attempts but also the Lifetime Reproductive Success (LRS) of specimens. However, what if there came an extra mortality factor in the moment of the lowest numbers of Osprey, already vulnerable in the country? In the years 2018-2020, we installed 22 trail cameras and five digital cameras (live online video feeds) on the nests. The total failure level observed in cameras (18.5%) was high. We observed, using these cameras, the extra mortality of chicks (10.7% of potentially fledged chicks) and even adult birds by unexpected predation by Northern Goshawk and White-tailed Eagle. This phenomenon is also common in the national population, as we found a total of ten cases of total losses by predators (eight or nine of them were birds of prey), including nests not covered by camera monitoring. The extra adult-predation by Goshawks means an extra drop in LRS. Those adult and chick predations are an example of exceptional catastrophic phenomena, which have been described as the direct cause of the extinction of animal populations throughout history. Only active conservation and stop poaching of the Polish population could stop the decline and save the Polish Ospreys.

20.
Nanomaterials (Basel) ; 11(2)2021 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-33670141

RESUMO

Gas sensitive structures made of nanowires exhibit extremally large specific surface area, and a great number of chemically active centres that can react with the ambient atmosphere. This makes the use of nanomaterials promising for super sensitive gas sensor applications. Monoclinic ß-Ga2O3 nanowires (NWs) were synthesized from metallic gallium at atmospheric pressure in the presence of nitrogen and water vapor. The nanowires were grown directly on interdigitated gold electrodes screen printed on Al2O3 substrates, which constituted the gas sensor structure. The observations made with transmission electron microscope (TEM) have shown that the nanowires are monocrystalline and their diameters vary from 80 to 300 nm with the average value of approximately 170 nm. Au droplets were found to be anchored at the tips of the nanowires which may indicate that the nanowires followed the Vapor-Liquid-Solid (VLS) mechanism of growth. The conductivity of ß-Ga2O3 NWs increases in the presence of volatile organic compounds (VOC) even in the temperature below 600 °C. The gas sensor based on the synthesized ß-Ga2O3 NWs shows peak sensitivity to 100 ppm of ethanol of 75.1 at 760 °C, while peak sensitivity to 100 ppm of acetone is 27.5 at 690 °C.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA