Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Foot Ankle Surg ; 54(4): 646-51, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25128304

RESUMO

The treatment of tibial plafond fractures is challenging to foot and ankle surgeons. Open reduction and internal fixation and limited internal fixation combined with an external fixator are 2 of the most commonly used methods of tibial plafond fracture repair. However, conclusions regarding the superior choice remain controversial. The present meta-analysis aimed to quantitatively compare the postoperative complications between open reduction and internal fixation and limited internal fixation combined with an external fixator for tibial plafond fractures. Nine studies with 498 fractures in 494 patients were included in the present study. The meta-analysis found no significant differences in bone healing complications (risk ratio [RR] 1.17, 95% confidence interval [CI] 0.68 to 2.01, p = .58], nonunion (RR 1.09, 95% CI 0.51 to 2.36, p = .82), malunion or delayed union (RR 1.24, 95% CI 0.57 to 2.69, p = .59), superficial (RR 1.56, 95% CI 0.43 to 5.61, p = .50) and deep (RR 1.89, 95% CI 0.62 to 5.80) infections, arthritis symptoms (RR 1.20, 95% CI 0.92 to 1.58, p = .18), or chronic osteomyelitis (RR 0.31, 95% CI 0.05 to 1.84, p = .20) between the 2 groups.


Assuntos
Fixadores Externos , Fixação Interna de Fraturas/métodos , Fraturas da Tíbia/cirurgia , Consolidação da Fratura , Fraturas Mal-Unidas/etiologia , Fraturas não Consolidadas/etiologia , Humanos , Osteomielite/etiologia , Complicações Pós-Operatórias
2.
Curr Med Sci ; 44(2): 391-398, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38517676

RESUMO

OBJECTIVE: The objective of this research was to explore the difference and correlation of the morphological and hemodynamic features between sidewall and bifurcation aneurysms in anterior circulation arteries, utilizing computational fluid dynamics as a tool for analysis. METHODS: In line with the designated inclusion criteria, this study covered 160 aneurysms identified in 131 patients who received treatment at Union Hospital of Tongji Medical College, Huazhong University of Science and Technology, China, from January 2021 to September 2022. Utilizing follow-up digital subtraction angiography (DSA) data, these cases were classified into two distinct groups: the sidewall aneurysm group and the bifurcation aneurysm group. Morphological and hemodynamic parameters in the immediate preoperative period were meticulously calculated and examined in both groups using a three-dimensional DSA reconstruction model. RESULTS: No significant differences were found in the morphological or hemodynamic parameters of bifurcation aneurysms at varied locations within the anterior circulation. However, pronounced differences were identified between sidewall and bifurcation aneurysms in terms of morphological parameters such as the diameter of the parent vessel (Dvessel), inflow angle (θF), and size ratio (SR), as well as the hemodynamic parameter of inflow concentration index (ICI) (P<0.001). Notably, only the SR exhibited a significant correlation with multiple hemodynamic parameters (P<0.001), while the ICI was closely related to several morphological parameters (R>0.5, P<0.001). CONCLUSIONS: The significant differences in certain morphological and hemodynamic parameters between sidewall and bifurcation aneurysms emphasize the importance to contemplate variances in threshold values for these parameters when evaluating the risk of rupture in anterior circulation aneurysms. Whether it is a bifurcation or sidewall aneurysm, these disparities should be considered. The morphological parameter SR has the potential to be a valuable clinical tool for promptly distinguishing the distinct rupture risks associated with sidewall and bifurcation aneurysms.


Assuntos
Aneurisma Roto , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/complicações , Aneurisma Roto/complicações , Hemodinâmica , China
3.
Front Neurol ; 15: 1268433, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38440116

RESUMO

Background and objective: Stent-assisted coil (SAC) embolization is a commonly used endovascular treatment for unruptured intracranial aneurysms (UIAs) but can be associated with symptomatic delayed intracerebral hemorrhage (DICH). Our study aimed to investigate the hemodynamic risk factors contributing to DICH following SAC embolization and to establish a classification for DICH predicated on hemodynamic profiles. Methods: This retrospective study included patients with UIAs located in the internal carotid artery (ICA) treated with SAC embolization at our institution from January 2021 to January 2022. We focused on eight patients who developed postoperative DICH and matched them with sixteen control patients without DICH. Using computational fluid dynamics, we evaluated the hemodynamic changes in distal arteries [terminal ICA, the anterior cerebral artery (ACA), and middle cerebral artery (MCA)] pre-and post-embolization. We distinguished DICH-related arteries from unrelated ones (ACA or MCA) and compared their hemodynamic alterations. An imbalance index, quantifying the differential in flow velocity changes between ACA and MCA post-embolization, was employed to gauge the flow distribution in distal arteries was used to assess distal arterial flow distribution. Results: We identified two types of DICH based on postoperative flow alterations. In type 1, there was a significant lower in the mean velocity increase rate of the DICH-related artery compared to the unrelated artery (-47.25 ± 3.88% vs. 42.85 ± 3.03%; p < 0.001), whereas, in type 2, there was a notable higher (110.58 ± 9.42% vs. 17.60 ± 4.69%; p < 0.001). Both DICH types demonstrated a higher imbalance index than the control group, suggesting an association between altered distal arterial blood flow distribution and DICH occurrence. Conclusion: DICH in SAC-treated UIAs can manifest as either a lower (type 1) or higher (type 2) in the rate of velocity in DICH-related arteries. An imbalance in distal arterial blood flow distribution appears to be a significant factor in DICH development.

4.
Front Neurol ; 14: 1095266, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37181546

RESUMO

Background: The shaping of an accurate and stable microcatheter plays a vital role in the successful embolization of intracranial aneurysms. Our study aimed to investigate the application and the role of AneuShape™ software in microcatheter shaping for intracranial aneurysm embolization. Methods: From January 2021 to June 2022, 105 patients with single unruptured intracranial aneurysms were retrospectively analyzed with or without AneuShape™ software to assist in microcatheter shaping. The rates of microcatheter accessibility, accurate positioning, and stability for shaping were analyzed. During the operation, fluoroscopy duration, radiation dose, immediate postoperative angiography, and procedure-related complications were evaluated. Results: Compared to the manual group, aneurysm-coiling procedures involving the AneuShape™ software exhibited superior results. The use of the software resulted in a lower rate of reshaping microcatheters (21.82 vs. 44.00%, p = 0.015) and higher rates of accessibility (81.82 vs. 58.00%, p = 0.008), better positioning (85.45 vs. 64.00%, p = 0.011), and higher stability (83.64 vs. 62.00%, p = 0.012). The software group also required more coils for both small (<7 mm) and large (≥7 mm) aneurysms compared to the manual group (3.50 ± 0.19 vs. 2.78 ± 0.11, p = 0.008 and 8.22 ± 0.36 vs. 6.00 ± 1.00, p = 0.081, respectively). In addition, the software group achieved better complete or approximately complete aneurysm obliteration (87.27 vs. 66.00%, p = 0.010) and had a lower procedure-related complication rate (3.60 vs. 12.00%, p = 0.107). Without this software, the operation had a longer intervention duration (34.31 ± 6.51 vs. 23.87 ± 6.98 min, p < 0.001) and a higher radiation dose (750.50 ± 177.81 vs. 563.53 ± 195.46 mGy, p < 0.001). Conclusions: Software-based microcatheter shaping techniques can assist in the precise shaping of microcatheters, reduce operating time and radiation dose, improve embolization density, and facilitate more stable and efficient intracranial aneurysm embolization.

5.
Orthop Surg ; 13(1): 306-313, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33403835

RESUMO

OBJECTIVE: To analyze the characteristics of menicus microstructure and to reconstruct a microstructure-mimicing 3D model of the menicus. METHODS: Human and sheep meniscus were collected and prepared for this study. Hematoxylin-eosin staining (HE) and Masson staining were conducted for histological analysis of the meniscus. For submicroscopic structure analysis, the meniscus was first freeze-dried and then scanned by scanning electron microscopy (SEM). The porosity of the meniscus was determined according to SEM images. A micro-MRI was used to scan each meniscus, immersed in distilled water, and a 3D digital model was reconstructed afterwards. A three-dimensional (3D) resin model was printed out based on the digital model. Before high-resolution micro-CT scanning, each meniscus was freeze-dried. Then, micro-scale two-dimensional (2D) CT projection images were obtained. The porosity of the meniscus was calculated according to micro-CT images. With micro-CT, multiple 2D projection images were collected. A 3D digital model based on 2D CT pictures was also reconstructed. The 3D digital model was exported as STL format. A 3D resin model was printed by 3D printer based on the 3D digital model. RESULTS: As revealed in the HE and Masson images, a meniscus is mostly composed of collagen, with a few cells disseminated between the collagen fiber bundles at the micro-scale. The SEM image clearly shows the path of highly cross-linked collagen fibers, and massive pores exist between the fibers. According to the SEM images, the porosity of the meniscus was 34.1% (34.1% ± 0.032%) and the diameters of the collagen fibers were varied. In addition, the cross-linking pattern of the fibers was irregular. The scanning accuracy of micro-MRI was 50 µm. The micro-MRI demonstrated the outline of the meniscus, but the microstructure was obscure. The micro-CT clearly displayed microfibers in the meniscus with a voxel size of 11.4 µm. The surface layer, lamellar layer, circumferential fibers, and radial fibers could be identified. The mean porosity of the meniscus according to micro-CT images was 33.92% (33.92% ± 0.03%). Moreover, a 3D model of the microstructure based on the micro-CT images was built. The microscale fibers could be displayed in the micro-CT image and the reconstructed 3D digital model. In addition, a 3D resin model was printed out based on the 3D digital model. CONCLUSION: It is extremely difficult to artificially simulate the microstructure of the meniscus because of the irregularity of the diameter and cross-linking pattern of fibers. The micro-MRI images failed to demonstrate the meniscus microstructure. Freeze-drying and micro-CT scanning are effective methods for 3D microstructure reconstruction of the meniscus, which is an important step towards mechanically functional 3D-printed meniscus grafts.


Assuntos
Imageamento Tridimensional , Meniscos Tibiais/diagnóstico por imagem , Meniscos Tibiais/fisiologia , Impressão Tridimensional , Animais , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Microscopia Eletrônica de Varredura , Pessoa de Meia-Idade , Ovinos , Tomografia Computadorizada por Raios X
7.
Neuropsychiatr Dis Treat ; 14: 1035-1046, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29713173

RESUMO

INTRODUCTION: Previously published articles have suggested that BDNF rs6265 G>A polymorphism is a potential risk factor for epilepsy. However, the results were not consistent. METHODS: We conducted a meta-analysis to explore the association between BDNF rs6265 G>A polymorphism and epilepsy risk. Four online databases were searched, and related studies were reviewed from their inception up to June 20, 2017. ORs and corresponding 95% CIs were used to calculate the associations of each genetic model. Overall, 10 case-control publications involving 9,512 subjects were included in this meta-analysis. RESULTS: Significant associations were found between BDNF rs6265 G>A polymorphism and epilepsy (A vs G: OR=0.88, 95% CI=0.83-0.94, P<0.01, I2=0%; GA vs GG: OR=0.88, 95% CI=0.79-0.97, P=0.01, I2=0%; AA vs GG: OR=0.79, 95% CI=0.70-0.90, P<0.01, I2=0%; GA+AA vs GG: OR=0.85, 95% CI=0.77-0.94, P<0.01, I2=0%; AA vs GG+GA: OR=0.85, 95% CI=0.76-0.95, P=0.01, I2=0%). Subgroup analysis also showed similar results in an Asian population. CONCLUSION: Our meta-analysis indicated that BDNF rs6265 G>A polymorphism might be involved in epilepsy susceptibility, especially in the Asian population.

8.
Neural Regen Res ; 11(11): 1845-1850, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28123431

RESUMO

Acellular nerve allografts can help preserve normal nerve structure and extracellular matrix composition. These allografts have low immunogenicity and are more readily available than autologous nerves for the repair of long-segment peripheral nerve defects. In this study, we repaired a 40-mm ulnar nerve defect in rhesus monkeys with tissue-engineered peripheral nerve, and compared the outcome with that of autograft. The graft was prepared using a chemical extract from adult rhesus monkeys and seeded with allogeneic Schwann cells. Pathomorphology, electromyogram and immunohistochemistry findings revealed the absence of palmar erosion or ulcers, and that the morphology and elasticity of the hypothenar eminence were normal 5 months postoperatively. There were no significant differences in the mean peak compound muscle action potential, the mean nerve conduction velocity, or the number of neurofilaments between the experimental and control groups. However, outcome was significantly better in the experimental group than in the blank group. These findings suggest that chemically extracted allogeneic nerve seeded with autologous Schwann cells can repair 40-mm ulnar nerve defects in the rhesus monkey. The outcomes are similar to those obtained with autologous nerve graft.

9.
Int J Clin Exp Med ; 8(8): 14424-31, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26550430

RESUMO

It has been suggested that the amount of calcium intake may influence hip fracture incidence. However, the results of the researches in this regard are inconsistent. We performed this meta-analysis to estimate the association between calcium intake and hip fracture risk. Prospective cohort studies on calcium intake and hip fracture risk were identified by searching databases from the period 1960 to 2014. Results from individual studies were synthetically combined using STATA 11 software. The results indicated that a total of 8 prospective cohort studies were included in our meta-analysis, involving 2,435 cases and 267,759 participants. The combined relative risk (RR) of hip fracture for highest compared with lowest amount calcium intake was 0.97 (95% confidence interval [CI]: 0.89-1.07). Little evidence of publication bias was found. In conclusion, this meta-analysis provides evidence of no association between calcium intake and hip fracture risk. However, this finding is based on only a limited number of included studies.

10.
Microsurgery ; 28(1): 17-20, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-17994595

RESUMO

The purpose of this study was to describe microsurgical anatomy of the dorsal root entry zone (DREZ) and provide an anatomic basis for the approach of DREZ lesion in treating radiculopathy of brachial plexus avulsion injuries. We studied 100 dorsal cervical roots and DREZ/posterior horn complexes in 20 adult cadavers. At each root level the following data were recorded: widths of laminectomy, numbers of posterior rootlets, angle of the inferior rootlets with the spinal cord, and distance from posterior median sulcus to posterolateral sulcus. On cross-sectional plane, the length and width of dorsal horn and the angle between longitudinal axis of dorsal horn and sagittal plane of spinal cord were measured. The results showed that the spinal cord segment and the entry of dorsal roots from C5 to T1 were exposed clearly after laminectomy from C4 to C7. The average number of roolets of C5-T1 roots was about 7.76 and C6 has the most. From up to down, the angle from the inferior rootlet to spinal cord of C5-T1 diminished gradually. The average distance from posterior median sulcus to posterolateral sulcus was 2.95 mm. The average length, width, and angle of posterior horn were 3.47 mm, 1.346 mm, and 35.9 degrees , respectively. Our study demonstrated that the spinous process and lamina of the C4 to C7 vertebrae should be resected to expose the C5-T1 when DREZ lesions are employed to treat pain after brachial plexus avulsion. The lesion-making apparatus should be inserted at an angle of 30 degrees -40 degrees , the width of lesion should be less than 1.2 mm and the lesion depth less than 3.1 mm.


Assuntos
Plexo Braquial/anatomia & histologia , Laminectomia/métodos , Microcirurgia/métodos , Raízes Nervosas Espinhais/anatomia & histologia , Plexo Braquial/cirurgia , Neuropatias do Plexo Braquial/cirurgia , Cadáver , Vértebras Cervicais/anatomia & histologia , Vértebras Cervicais/cirurgia , Dissecação , Humanos , Medula Espinal/anatomia & histologia , Medula Espinal/cirurgia , Raízes Nervosas Espinhais/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA