Sensors (Basel) ; 17(6)2017 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-28587221

RESUMO

An hourglass in-fiber air microcavity Fabry-Perot interferometer is proposed in this paper, and its second reflecting surface of in-fiber microcavity is designed to be a concave reflector with the best curvature radius in order to improve the spectral characteristics. Experimental results proved that the extinction ratio of Fabry-Perot interferometer with cavity length of 60 µm and concave reflector radius of 60 µm is higher than for a rectangular Fabry-Perot interferometer with cavity length of 60 µm (14 dB: 11 dB). Theory and numerical simulation results show that the strain sensitivity of sensor can be improved by reducing the microcavity wall thickness and microcavity diameter, and when the in-fiber microcavity length is 40 µm, the microcavity wall thickness is 10 µm, the microcavity diameter is 20 µm, and the curvature radius of reflective surface II is 50 µm, the interference fringe contrast of is greater than 0.97, an Axial-pull sensitivity of 20.46 nm/N and resolution of 1 mN can be achieved in the range of 0-1 N axial tension. The results show that the performance of hourglass in-fiber microcavity interferometer is far superior to that of the traditional Fabry-Perot interferometer.