Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Echocardiography ; 39(8): 1131-1137, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35768900

RESUMO

Fabry disease is a rare X-linked lysosomal storage disorder caused by a deficiency in the lysosomal enzyme, galactosidase A, that can result in a progressive increase in the left ventricle (LV) wall thickness from glycosphingolipid deposition leading to myocardial fibrosis, conduction abnormalities, arrhythmias, and heart failure. We present a case of a patient with advanced Fabry cardiomyopathy, in whom a small LV apical aneurysm was incidentally discovered on abdominal imaging, which could have easily evaded detection on standard transthoracic echocardiography. The LV apex should be thoroughly interrogated in patients with Fabry cardiomyopathy, as the finding of LV aneurysm could have important management implications with respect to the prevention of stroke and sudden cardiac death.


Assuntos
Cardiomiopatias , Doença de Fabry , Aneurisma Cardíaco , Arritmias Cardíacas , Ecocardiografia , Humanos , Miocárdio
2.
J Cardiovasc Electrophysiol ; 32(3): 729-734, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33476450

RESUMO

BACKGROUND: Transseptal access for large sheaths may be encumbered by tissue resistance against the sheath-dilator stepped interface. The ExpanSure Large Access Transseptal Dilator (Baylis Medical) is designed as a single introducer and dilation device with a smooth sheath-dilator transition to support transseptal puncture. It may facilitate ease and efficiency of interatrial crossing. METHODS: This study experimentally evaluated the crossing force of ExpanSure relative to a conventional 8.5 F Swartz SL1 transseptal sheath and dilator in a benchtop septum model. Its ability to reduce the subsequent crossing force of a 14 F WATCHMAN delivery sheath was also tested. The clinical use of ExpanSure, including procedure time, was then validated in a series of left atrial appendage closure (LAAC) procedures. RESULTS: In a benchtop septum model (N = 12), less peak force (1.90 ± 0.08 N vs. 2.36 ± 0.09 N; p < .001) and overall work (17.3 ± 1.2 mJ vs. 28.0 ± 1.9 mJ; p < .001) were required to advance ExpanSure relative to a conventional SL1 transseptal sheath and dilator system. Peak force (2.34 ± 0.24 N vs. 2.65 ± 0.21 N; p < .003) and overall work (28.5 ± 3.9 mJ vs. 35.4 ± 2.1 mJ; p < .001) to advance a WATCHMAN sheath were also significantly lower after using ExpanSure than after using a conventional transseptal system. In 19 LAAC procedures, ExpanSure crossed the septum smoothly and integrated readily, which enabled efficient procedure completion (mean total procedure time 37.6 ± 13.5 min), with 100% success and no procedure-related complications. CONCLUSION: Experimental force measurements, combined with early clinical experience using ExpanSure, suggest that the tapered design with smooth transition without dilator-sheath step-up and the larger diameter, both facilitated ease and efficiency of interatrial crossing.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/efeitos adversos , Átrios do Coração/cirurgia , Humanos , Punções , Resultado do Tratamento
3.
Can Fam Physician ; 67(3): 171-179, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33727376

RESUMO

OBJECTIVE: To keep health care providers, in response to the ongoing coronavirus disease 2019 (COVID-19) pandemic, informed about the medications that have been proposed to treat the disease and the evidence supporting their use. QUALITY OF EVIDENCE: A narrative review of medications most widely used to treat COVID-19 was conducted, outlining the best available evidence for each pharmacologic treatment to date. Searches were performed in PubMed, EMBASE, and MEDLINE using key words COVID-19 and treatment, as well as related terms. Relevant research studies conducted in human populations and cases specific to patients with COVID-19 were included, as were relevant hand-searched papers and reviews. Only articles in English and Chinese were included. MAIN MESSAGE: While current management of patients with COVID-19 largely involves supportive care, without a widely available vaccine, practitioners have also resorted to repurposing medications used for other indications. This has caused considerable controversy, as many of these treatments have limited clinical evidence supporting their use and therefore pose implications for patient safety, drug access, and public health. For instance, medications such as hydroxychloroquine and chloroquine, lopinavir-ritonavir, nonsteroidal anti-inflammatory drugs, angiotensin-converting enzyme inhibitors, and angiotensin receptor blockers gained widespread media attention owing to hype, misinformation, or misinterpretation of research evidence. CONCLUSION: Given the severity of the pandemic and the potential broad effects of implementing safe and effective treatment, this article provides a narrative review of the current evidence behind the most widely used medications to treat COVID-19 in order to enable health care practitioners to make informed decisions in the care of patients with this life-threatening disease.


Assuntos
Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Antivirais/uso terapêutico , Tratamento Farmacológico da COVID-19 , Medicina Baseada em Evidências , Imunoglobulinas/uso terapêutico , Cloroquina/uso terapêutico , Quimioterapia Combinada , Humanos , Hidroxicloroquina/uso terapêutico
4.
BMC Cardiovasc Disord ; 20(1): 274, 2020 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-32503490

RESUMO

BACKGROUND: Ventricular strain measurements vary depending on cardiac chamber (left ventricle [LV] or right ventricle [RV]), type of strain (longitudinal, circumferential, or radial), ventricular level (basal, mid, or apical), myocardial layer (endocardial or epicardial), and software used for analysis, among other demographic factors such as age and gender. Here, we present an analysis of ventricular strain taking all of these variables into account in a cohort of patients with no structural heart disease using a vendor-independent speckle-tracking software. METHODS: LV and RV full-thickness strain parameters were retrospectively measured in 102 patients (mean age 39 ± 15 years; 62% female). Within this cohort, we performed further layer-specific strain analysis in 20 subjects. Data were analyzed for global and segmental systolic strain, systolic strain rate, early diastolic strain rate, and their respective time-to-peak values. RESULTS: Mean LV global longitudinal, circumferential, and radial strain values for the entire cohort were - 18.4 ± 2.0%, - 22.1 ± 4.1%, and 43.9 ± 12.1% respectively, while mean RV global and free wall longitudinal strain values were - 24.2 ± 3.9% and - 26.1 ± 5.2% respectively. Women on average demonstrated higher longitudinal and circumferential strain and strain rate than men, and longer corresponding time-to-peak values. Longitudinal strain measurements were highest at the apex compared with the mid ventricle and base, and in the endocardium compared with the epicardium. Longitudinal strain was the most reproducible measure, followed closely by circumferential strain, while radial strain showed suboptimal reproducibility. CONCLUSIONS: We present an analysis of ventricular strain in patients with no structural heart disease using a vendor-independent speckle-tracking software.


Assuntos
Ecocardiografia , Ventrículos do Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador , Função Ventricular Esquerda , Função Ventricular Direita , Adulto , Bases de Dados Factuais , Diástole , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Software , Sístole , Adulto Jovem
5.
BMC Cardiovasc Disord ; 20(1): 33, 2020 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-32000672

RESUMO

BACKGROUND: Aortic stenosis (AS) causes left ventricular (LV) pressure overload, leading to adverse LV remodeling and dysfunction. Identifying early subclinical markers of LV dysfunction in patients with significant AS is critical as this could provide support for earlier intervention, which may result in improved long-term outcomes. We therefore examined the impact of severe AS and its consequent increase in LV afterload on myocardial deformation and rotational mechanics by 2-dimensional (2D) and 3-dimensional (3D) speckle-tracking echocardiography. METHODS: We prospectively measured various strain parameters in 168 patients (42% female, mean age 72 ± 12 years) with severe AS and LV ejection fraction (EF) ≥50%, and compared them to normal values found in literature. 2D and 3D images were analyzed for global longitudinal strain (GLS), global circumferential strain (GCS), global radial strain (GRS), basal rotation, apical rotation, and peak systolic twist. We further assessed the degree of concordance between 2D and 3D strain, and examined their association with measures of LV preload and afterload. RESULTS: Patients with severe AS exhibited significantly lower GLS and GRS but higher GCS, apical rotation, and twist by 2D and 3D echocardiography compared with published normal values (P = 0.003 for 3D twist, P < 0.001 for all others). Agreement between 2D- and 3D-GLS by concordance correlation coefficient was 0.49 (95% confidence interval: 0.39-0.57). GLS was correlated with valvulo-arterial impedance, a measure of LV afterload (r = 0.34, p < 0.001 and r = 0.23, p = 0.003, respectively). CONCLUSION: Patients with severe AS demonstrated lower-than-normal GLS and GRS but appear to compensate with higher-than-normal GCS, apical rotation, and twist in order to maintain a preserved LVEF. GLS showed a modest correlation with valvulo-arterial impedance.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Ecocardiografia Tridimensional , Contração Miocárdica , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/fisiopatologia , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Rotação , Índice de Gravidade de Doença , Disfunção Ventricular Esquerda/fisiopatologia
6.
Catheter Cardiovasc Interv ; 94(5): 702-705, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31033181

RESUMO

A 54-year-old woman with no prior coronary artery disease or cardiac risk factors was diagnosed with spontaneous coronary artery dissection (SCAD) after presenting with an acute coronary syndrome. Over the next 5 years, she experienced four more episodes of SCAD, involving different coronary artery distributions, with evidence of complete angiographic healing following conservative management with antiplatelet therapy and beta-blockade.


Assuntos
Anomalias dos Vasos Coronários/etiologia , Displasia Fibromuscular/complicações , Doenças Vasculares/congênito , Síndrome Coronariana Aguda/etiologia , Antagonistas Adrenérgicos beta/uso terapêutico , Anomalias dos Vasos Coronários/diagnóstico por imagem , Anomalias dos Vasos Coronários/tratamento farmacológico , Feminino , Displasia Fibromuscular/diagnóstico por imagem , Displasia Fibromuscular/tratamento farmacológico , Humanos , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/uso terapêutico , Recidiva , Resultado do Tratamento , Doenças Vasculares/diagnóstico por imagem , Doenças Vasculares/tratamento farmacológico , Doenças Vasculares/etiologia
7.
Echocardiography ; 35(1): 123-125, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29178279

RESUMO

Pulmonary artery sarcoma is a rare malignant neoplasm. Here, we describe a patient with a pulmonary artery sarcoma, which was only subtly visible and therefore not fully appreciated on initial transthoracic echocardiogram. Characterization of the tumor was aided by the use of multimodality imaging that included computed tomography, magnetic resonance imaging, and positron emission tomography. Familiarity with its appearance on multiple imaging modalities including echocardiography is important to ensure timely diagnosis, although the optimal treatment strategy is still unknown, and the prognosis remains poor.


Assuntos
Imagem Multimodal/métodos , Artéria Pulmonar/diagnóstico por imagem , Sarcoma/diagnóstico por imagem , Neoplasias Vasculares/diagnóstico por imagem , Adulto , Diagnóstico Diferencial , Ecocardiografia , Evolução Fatal , Humanos , Imageamento por Ressonância Magnética , Masculino , Tomografia por Emissão de Pósitrons , Artéria Pulmonar/cirurgia , Sarcoma/cirurgia , Tomografia Computadorizada por Raios X , Neoplasias Vasculares/cirurgia , Adulto Jovem
8.
Can Fam Physician ; 67(3): e69-e78, 2021 Mar.
Artigo em Francês | MEDLINE | ID: mdl-33727386

RESUMO

OBJECTIF: En réponse à la pandémie actuelle de maladie à coronavirus 2019 (COVID-19), garder les médecins au fait des médicaments qui ont été proposés pour combattre la maladie, et des données probantes à l'appui de leur utilisation. SOURCES D'INFORMATION: Une revue narrative des médicaments les plus fréquemment utilisés pour combattre la COVID-19 a été réalisée, afin de souligner les meilleures données probantes disponibles concernant chaque traitement pharmacologique jusqu'ici. Des recherches ont été effectuées sur PubMed, EMBASE et MEDLINE à l'aide des mots-clés anglais COVID-19 et treatment, ainsi que d'autres mots-clés connexes. Ont été inclus les études pertinentes menées auprès de populations humaines et des cas de patients atteints de la COVID-19, ainsi que les articles et revues relevés à la main. Seuls les articles rédigés en anglais et en chinois ont été retenus. MESSAGE PRINCIPAL: Alors que la prise en charge actuelle des patients atteints de la COVID-19 consiste principalement en soins de soutien, sans accès aux vaccins, les praticiens se sont tournés vers des médicaments utilisés dans d'autres indications. Cela a causé une grande controverse, puisque des données cliniques limitées étayaient l'utilisation de beaucoup de ces traitements, et cela pouvait se répercuter sur la sécurité du patient, l'accès aux médicaments et la santé publique. Par exemple, les médicaments tels que l'hydroxychloroquine et la chloroquine, le lopinavir-ritonavir, les anti-inflammatoires non stéroïdiens, les inhibiteurs de l'enzyme de conversion de l'angiotensine et les antagonistes des récepteurs de l'angiotensine ont capté l'attention des médias en raison de la médiatisation, de la mésinformation ou de la mauvaise interprétation des données de recherche. CONCLUSION: Vu la gravité de la pandémie et les vastes effets éventuels de l'adoption de traitements sûrs et efficaces, cet article se veut être une revue narrative des données probantes actuelles étayant les médicaments les plus utilisés pour le traitement de la COVID-19 afin de permettre aux professionnels de la santé de prendre des décisions éclairées en matière de soins pour les patients qui sont atteints de cette maladie potentiellement mortelle.


Assuntos
Tratamento Farmacológico da COVID-19 , COVID-19 , Tratamento Farmacológico , Preparações Farmacêuticas , COVID-19/epidemiologia , Humanos , SARS-CoV-2
10.
Artigo em Inglês | MEDLINE | ID: mdl-39126604

RESUMO

Left ventricular (LV) geometric patterns aid clinicians in the diagnosis and prognostication of various cardiomyopathies. The aim of this study is to assess the accuracy and reproducibility of LV dimensions and wall thickness using deep learning (DL) models. A total of 30,080 unique studies were included; 24,013 studies were used to train a convolutional neural network model to automatically assess, at end-diastole, LV internal diameter (LVID), interventricular septal wall thickness (IVS), posterior wall thickness (PWT), and LV mass. The model was trained to select end-diastolic frames with the largest LVID and to identify four landmarks, marking the dimensions of LVID, IVS, and PWT using manually labeled landmarks as reference. The model was validated with 3,014 echocardiographic cines and the accuracy of the model was evaluated with a test set of 3,053 echocardiographic cines. The model accurately measured LVID, IVS, PWT, and LV mass compared to study report values with a mean relative error of 5.40%, 11.73%, 12.76%, and 13.93%, respectively. The 𝑅2 of the model for the LVID, IVS, PWT, and the LV mass was 0.88, 0.63, 0.50, and 0.87, respectively. The novel DL model developed in this study was accurate for LV dimension assessment without the need to select end-diastolic frames manually. DL automated measurements of IVS and PWT were less accurate with greater wall thickness. Validation studies in larger and more diverse populations are ongoing.

11.
Diseases ; 12(2)2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38391782

RESUMO

BACKGROUND: Automated rhythm detection on echocardiography through artificial intelligence (AI) has yet to be fully realized. We propose an AI model trained to identify atrial fibrillation (AF) using apical 4-chamber (AP4) cines without requiring electrocardiogram (ECG) data. METHODS: Transthoracic echocardiography studies of consecutive patients ≥ 18 years old at our tertiary care centre were retrospectively reviewed for AF and sinus rhythm. The study was first interpreted by level III-trained echocardiography cardiologists as the gold standard for rhythm diagnosis based on ECG rhythm strip and imaging assessment, which was also verified with a 12-lead ECG around the time of the study. AP4 cines with three cardiac cycles were then extracted from these studies with the rhythm strip and Doppler information removed and introduced to the deep learning model ResNet(2+1)D with an 80:10:10 training-validation-test split ratio. RESULTS: 634 patient studies (1205 cines) were included. After training, the AI model achieved high accuracy on validation for detection of both AF and sinus rhythm (mean F1-score = 0.92; AUROC = 0.95). Performance was consistent on the test dataset (mean F1-score = 0.94, AUROC = 0.98) when using the cardiologist's assessment of the ECG rhythm strip as the gold standard, who had access to the full study and external ECG data, while the AI model did not. CONCLUSIONS: AF detection by AI on echocardiography without ECG appears accurate when compared to an echocardiography cardiologist's assessment of the ECG rhythm strip as the gold standard. This has potential clinical implications in point-of-care ultrasound and stroke risk stratification.

12.
Life (Basel) ; 14(2)2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38398708

RESUMO

Hypertrophic cardiomyopathy (HCM) is a common genetic disorder with a well described risk of sudden cardiac death; however, risk stratification has remained a challenge. Recently, novel parameters in cardiac magnetic resonance imaging (CMR) have shown promise in helping to improve upon current risk stratification paradigms. In this manuscript, we have reviewed novel CMR risk markers and their utility in HCM. The results of the review showed that T1, extracellular volume, CMR feature tracking, and other miscellaneous novel CMR variables have the potential to improve sudden death risk stratification and may have additional roles in diagnosis and prognosis. The strengths and weaknesses of these imaging techniques, and their potential utility and implementation in HCM risk stratification are discussed.

13.
Echo Res Pract ; 11(1): 9, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38539236

RESUMO

BACKGROUND: Machine learning (ML) algorithms can accurately estimate left ventricular ejection fraction (LVEF) from echocardiography, but their performance on cardiac point-of-care ultrasound (POCUS) is not well understood. OBJECTIVES: We evaluate the performance of an ML model for estimation of LVEF on cardiac POCUS compared with Level III echocardiographers' interpretation and formal echo reported LVEF. METHODS: Clinicians at a tertiary care heart failure clinic prospectively scanned 138 participants using hand-carried devices. Video data were analyzed offline by an ML model for LVEF. We compared the ML model's performance with Level III echocardiographers' interpretation and echo reported LVEF. RESULTS: There were 138 participants scanned, yielding 1257 videos. The ML model generated LVEF predictions on 341 videos. We observed a good intraclass correlation (ICC) between the ML model's predictions and the reference standards (ICC = 0.77-0.84). When comparing LVEF estimates for randomized single POCUS videos, the ICC between the ML model and Level III echocardiographers' estimates was 0.772, and it was 0.778 for videos where quantitative LVEF was feasible. When the Level III echocardiographer reviewed all POCUS videos for a participant, the ICC improved to 0.794 and 0.843 when only accounting for studies that could be segmented. The ML model's LVEF estimates also correlated well with LVEF derived from formal echocardiogram reports (ICC = 0.798). CONCLUSION: Our results suggest that clinician-driven cardiac POCUS produces ML model LVEF estimates that correlate well with expert interpretation and echo reported LVEF.

14.
BMC Cardiovasc Disord ; 13: 114, 2013 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-24325765

RESUMO

BACKGROUND: Canadians of Chinese descent, represent one of the fastest growing visible minority groups in Canada, (as well as the second largest), but relatively little is known about the clinical features of heart failure (HF) in Chinese-Canadian versus non-Chinese Canadian patients. METHODS: We conducted a population-based analysis of urban patients hospitalized in Ontario, Canada for the first time with a most responsible diagnosis of HF between April 1, 1995 and March 31, 2008. Among the 99,278 patients, 1,339 (1.3%) were classified as Chinese using a previously validated list of Chinese surnames. Through linkage to other administrative databases, we compared the clinical characteristics, pharmacological management, and outcomes of Chinese versus non-Chinese HF patients. RESULTS: Ischemic heart disease was identified as the possible etiology of HF in a greater proportion of non-Chinese patients (47.7% vs. 35.3%; p < 0.001) whereas hypertension (26.1% vs. 16.1%; p < 0.001) and valvular heart disease (11.6% vs. 7.2%; p < 0.001) were relatively more common in Chinese patients. Chinese patients were prescribed angiotensin-converting enzyme (ACE) inhibitors less frequently (57.5% vs. 66.4%, p < 0.001) and angiotensin receptor blockers (ARBs) more frequently (17.4% vs. 8.9%, p < 0.001) compared to non-Chinese patients. They were also less likely to be adherent to ACE inhibitors over a 1-year follow up period. However, the 1-year case-fatality rates were comparable between the Chinese (31.7%) and non-Chinese (30.2%) subjects (p = 0.24). CONCLUSION: There are important differences in the causes and medical management of HF in Chinese and non-Chinese patients residing in Canada. Despite these differences, the long-term outcomes of HF patients were similar.


Assuntos
Povo Asiático/etnologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etnologia , Hospitalização/tendências , Idoso , Idoso de 80 Anos ou mais , Canadá/etnologia , Estudos de Coortes , Feminino , Humanos , Masculino , Ontário/etnologia
15.
Int J Cardiovasc Imaging ; 39(7): 1313-1321, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37150757

RESUMO

We sought to determine the cardiac ultrasound view of greatest quality using a machine learning (ML) approach on a cohort of transthoracic echocardiograms (TTE) with abnormal left ventricular (LV) systolic function. We utilize an ML model to determine the TTE view of highest quality when scanned by sonographers. A random sample of TTEs with reported LV dysfunction from 09/25/2017-01/15/2019 were downloaded from the regional database. Component video files were analyzed using ML models that jointly classified view and image quality. The model consisted of convolutional layers for extracting spatial features and Long Short-term Memory units to temporally aggregate the frame-wise spatial embeddings. We report the view-specific quality scores for each TTE. Pair-wise comparisons amongst views were performed with Wilcoxon signed-rank test. Of 1,145 TTEs analyzed by the ML model, 74.5% were from males and mean LV ejection fraction was 43.1 ± 9.9%. Maximum quality score was best for the apical 4 chamber (AP4) view (70.6 ± 13.9%, p<0.001 compared to all other views) and worst for the apical 2 chamber (AP2) view (60.4 ± 15.4%, p<0.001 for all views except parasternal short-axis view at mitral/papillary muscle level, PSAX M/PM). In TTEs scanned by professional sonographers, the view with greatest ML-derived quality was the AP4 view.


Assuntos
Ecocardiografia , Disfunção Ventricular Esquerda , Masculino , Humanos , Valor Preditivo dos Testes , Ecocardiografia/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda/fisiologia , Volume Sistólico , Aprendizado de Máquina
16.
J Echocardiogr ; 21(1): 33-39, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35974215

RESUMO

PURPOSE: There is lack of validated methods for quantifying the size of pleural effusion from standard transthoracic (TTE) windows. The purpose of this study is to determine whether pleural effusion (Peff) measured from routine two-dimensional (2D) TTE views correlate with chest radiograph (CXR). MATERIALS AND METHODS: We retrospectively identified all inpatients who underwent a TTE and CXR within 2 days in a large tertiary care center. Peff was measured on TTE from parasternal long axis (PLAX), apical four-chamber (A4C), and subcostal views and on CXR. Logistic regression models were used determine optimal cut points to predict moderate or greater Peff. RESULTS: In 200 patients (mean age 69.3 ± 14.3 years, 49.5% female), we found statistically significant associations between Peff size assessed by all TTE views and CXR, with weak to moderate correlation (PLAX length: 0.21 (95% CI [0.05, 0.35]); PLAX depth: 0.21 (95% CI [0.05, 0.35]); A4C left: 0.31 (95% CI [0.13, 0.46]); A4C right: 0.39 (95% CI [0.17, 0.57]); subcostal: 0.38 (95% CI [0.07, 0.61]). The best TTE thresholds for predicting moderate or greater left-sided Peff on CXR was PLAX length left > = 8.6 cm (sensitivity 78%, specificity 54%, PPV 26%, and NPV 92%). The best TTE thresholds for predicting moderate or greater right-sided Peff on CXR was A4C right > = 2.6 cm (sensitivity 87%, specificity 60%, PPV 37%, and NPV 94%). CONCLUSIONS: We identified statistically significant associations with Peff size measured on TTE and CXR. The predictive ability of TTE to identify moderate or large pleural effusion is limited.


Assuntos
Ecocardiografia , Derrame Pleural , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Estudos Retrospectivos , Ecocardiografia/métodos , Reprodutibilidade dos Testes
17.
J Cardiovasc Imaging ; 31(3): 125-132, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37488916

RESUMO

BACKGROUND: There is limited data on the residual echocardiographic findings including strain analysis among post-coronavirus disease (COVID) patients. The aim of our study is to prospectively phenotype post-COVID patients. METHODS: All patients discharged following acute COVID infection were systematically followed in the post-COVID-19 Recovery Clinic at Vancouver General Hospital and St. Paul's Hospital. At 4-18 weeks post diagnosis, patients underwent comprehensive echocardiographic assessment. Left ventricular ejection fraction (LVEF) was assessed by 3D, 2D Biplane Simpson's, or visual estimate. LV global longitudinal strain (GLS) was measured using a vendor-independent 2D speckle-tracking software (TomTec). RESULTS: A total of 127 patients (53% female, mean age 58 years) were included in our analyses. At baseline, cardiac conditions were present in 58% of the patients (15% coronary artery disease, 4% heart failure, 44% hypertension, 10% atrial fibrillation) while the remainder were free of cardiac conditions. COVID-19 serious complications were present in 79% of the patients (76% pneumonia, 37% intensive care unit admission, 21% intubation, 1% myocarditis). Normal LVEF was seen in 96% of the cohort and 97% had normal right ventricular systolic function. A high proportion (53%) had abnormal LV GLS defined as < 18%. Average LV GLS of septal and inferior segments were lower compared to that of other segments. Among patients without pre-existing cardiac conditions, LVEF was abnormal in only 1.9%, but LV GLS was abnormal in 46% of the patients. CONCLUSIONS: Most post-COVID patients had normal LVEF at 4-18 weeks post diagnosis, but over half had abnormal LV GLS.

18.
J Biol Chem ; 286(32): 27959-70, 2011 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-21680743

RESUMO

Many tripartite motif (TRIM) proteins self-associate, forming dimers and higher order complexes. For example, dimers of TRIM5α, a host factor that restricts retrovirus infection, assemble into higher order arrays on the surface of the viral capsid, resulting in an increase in avidity. Here we show that the higher order association of different TRIM proteins exhibits a wide range of efficiencies. Homologous association (self-association) was more efficient than the heterologous association of different TRIM proteins, indicating that specificity determinants of higher order self-association exist. To investigate the structural determinants of higher order self-association, we studied TRIM mutants and chimeras. These studies revealed the following: 1) the RING domain contributes to the efficiency of higher order self-association, which enhances the binding of TRIM5α to the human immunodeficiency virus (HIV-1) capsid; 2) the RING and B-box 2 domains work together as a homologous unit to promote higher order association of dimers; 3) dimerization is probably required for efficient higher order self-association; 4) the Linker 2 region contributes to higher order self-association, independently of effects of Linker 2 changes on TRIM dimerization; and 5) for efficiently self-associating TRIM proteins, the B30.2(SPRY) domain is not required for higher order self-association. These results support a model in which both ends of the core TRIM dimer (RING-B-box 2 at one end and Linker 2 at the other) contribute to the formation of higher order arrays.


Assuntos
Capsídeo/metabolismo , Proteínas de Transporte/metabolismo , HIV-1/metabolismo , Multimerização Proteica , Animais , Fatores de Restrição Antivirais , Proteínas de Transporte/genética , Linhagem Celular , HIV-1/genética , Humanos , Macaca mulatta , Mutação , Ligação Proteica , Estrutura Terciária de Proteína , Proteínas Recombinantes de Fusão/genética , Proteínas Recombinantes de Fusão/metabolismo , Proteínas com Motivo Tripartido , Ubiquitina-Proteína Ligases
19.
CMAJ ; 184(14): E765-73, 2012 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-22908143

RESUMO

BACKGROUND: Heart failure is a leading cause of admission to hospital, but whether the incidence of heart failure is increasing or decreasing is uncertain. We examined temporal trends in the incidence and outcomes of heart failure in Ontario, Canada. METHODS: Using population-based administrative databases of hospital discharge abstracts and physician health insurance claims, we identified 419 551 incident cases of heart failure in Ontario between Apr. 1, 1997, and Mar. 31, 2008. All patients were classified as either inpatients or outpatients based on the patient's location at the time of the initial diagnosis. We tracked subsequent outcomes through linked administrative databases. RESULTS: The age- and sex-standardized incidence of heart failure decreased 32.7% from 454.7 per 100 000 people in 1997 to 306.1 per 100 000 people in 2007 (p < 0.001). A comparable decrease in incidence occurred in both inpatient and outpatient settings. The greatest relative decrease occurred in patients aged 85 and over. Over the study period, 1-year risk-adjusted mortality decreased from 17.7% in 1997 to 16.2% in 2007 (p = 0.02) for outpatients, with a nonsignificant decrease from 35.7% in 1997 to 33.8% in 2007 (p = 0.1) for inpatients. INTERPRETATION: The incidence of heart failure decreased substantially during the study period. Nevertheless, the prognosis for patients with heart failure remains poor and is associated with high mortality.


Assuntos
Insuficiência Cardíaca/epidemiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Insuficiência Cardíaca/mortalidade , Hospitalização/tendências , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Ontário/epidemiologia , Prognóstico , Adulto Jovem
20.
Eur Heart J Open ; 2(6): oeac074, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36540107

RESUMO

Aims: Aortic stenosis (AS) induces characteristic changes in left ventricular (LV) mechanics that can be reversed after aortic valve replacement (AVR). We aimed to comprehensively characterize LV mechanics before and after AVR in patients with severe AS and identify predictors of short-term functional recovery and long-term survival. Methods and results: We prospectively performed comprehensive strain analysis by 2D speckle-tracking echocardiography in 88 patients with severe AS and LV ejection fraction ≥50% (mean age 71 ± 12 years, 42% female) prior to and within 7 days after AVR. Patients were followed for up to 5.2 years until death from any cause or last encounter. Within days after AVR, we observed an absolute increase in global longitudinal strain (GLS) (-16.0 ± 2.0% vs. -18.5 ± 2.1%, P<0.0001) and a decrease in apical rotation (10.5 ± 4.0° vs. 8.3 ± 2.8°, P = 0.0002) and peak systolic twist (18.2 ± 5.0° vs. 15.5 ± 3.8°, P = 0.0008). A baseline GLS is less negative than -16.2% was 90% sensitive and 67% specific in predicting a ≥ 20% relative increase in GLS. During a median follow-up of 3.8 years, a global circumferential systolic strain rate (GCSRs) less negative than -1.9% independently predicted lower survival. Conclusion: In patients with severe AS, a reversal in GLS, apical rotation, and peak systolic twist abnormalities towards normal occurs within days of AVR. Baseline GLS is the strongest predictor of GLS recovery but neither was associated with long-term survival. In contrast, abnormal baseline GCSRs are associated with worse outcomes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA