Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
BMC Med Imaging ; 24(1): 36, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38321373

RESUMO

BACKGROUND: Ultrasound imaging is the most frequently performed for the patients with chronic hepatitis or liver cirrhosis. However, ultrasound imaging is highly operator dependent and interpretation of ultrasound images is subjective, thus well-trained radiologist is required for evaluation. Automated classification of liver fibrosis could alleviate the shortage of skilled radiologist especially in low-to-middle income countries. The purposed of this study is to evaluate deep convolutional neural networks (DCNNs) for classifying the degree of liver fibrosis according to the METAVIR score using US images. METHODS: We used ultrasound (US) images from two tertiary university hospitals. A total of 7920 US images from 933 patients were used for training/validation of DCNNs. All patient were underwent liver biopsy or hepatectomy, and liver fibrosis was categorized based on pathology results using the METAVIR score. Five well-established DCNNs (VGGNet, ResNet, DenseNet, EfficientNet and ViT) was implemented to predict the METAVIR score. The performance of DCNNs for five-level (F0/F1/F2/F3/F4) classification was evaluated through area under the receiver operating characteristic curve (AUC) with 95% confidential interval, accuracy, sensitivity, specificity, positive and negative likelihood ratio. RESULTS: Similar mean AUC values were achieved for five models; VGGNet (0.96), ResNet (0.96), DenseNet (0.95), EfficientNet (0.96), and ViT (0.95). The same mean accuracy (0.94) and specificity values (0.96) were yielded for all models. In terms of sensitivity, EffcientNet achieved highest mean value (0.85) while the other models produced slightly lower values range from 0.82 to 0.84. CONCLUSION: In this study, we demonstrated that DCNNs can classify the staging of liver fibrosis according to METAVIR score with high performance using conventional B-mode images. Among them, EfficientNET that have fewer parameters and computation cost produced highest performance. From the results, we believe that DCNNs based classification of liver fibrosis may allow fast and accurate diagnosis of liver fibrosis without needs of additional equipment for add-on test and may be powerful tool for supporting radiologists in clinical practice.


Assuntos
Técnicas de Imagem por Elasticidade , Humanos , Técnicas de Imagem por Elasticidade/métodos , Cirrose Hepática/patologia , Ultrassonografia , Curva ROC , Redes Neurais de Computação , Fígado/diagnóstico por imagem
2.
Pharm Res ; 38(8): 1455-1466, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34398405

RESUMO

PURPOSE: To develop an in vitro culture system for tissue engineering to mimic the in vivo environment and evaluate the applicability of ultrasound and PLGA particle system. METHODS: For tissue engineering, large molecules such as growth factors for cell differentiation should be supplied in a controlled manner into the culture system, and the in vivo microenvironment need to be reproduced in the system for the regulation of cellular function. In this study, portable prototype ultrasound with low intensity was devised and tested for protein release from bovine serum albumin (BSA)-loaded poly(lactic-co-glycolic acid) (PLGA) particles. RESULTS: BSA-loaded PLGA particles were prepared using various types of PLGA reagents and their physicochemical properties were characterized including particle size, shape, or aqueous wetting profiles. The BSA-loaded formulation showed nano-ranged size distribution with optimal physical stability during storage period, and protein release behaviors in a controlled manner. Notably, the application of prototype ultrasound with low intensity influenced protein release patterns in the culture system containing the BSA-loaded PLGA formulation. The results revealed that the portable ultrasound set controlled by the computer could contribute for the protein delivery in the culture medium. CONCLUSIONS: This study suggests that combined application with ultrasound and protein-loaded PLGA encapsulation system could be utilized to improve culture system for tissue engineering or cell regeneration therapy.


Assuntos
Copolímero de Ácido Poliláctico e Ácido Poliglicólico/química , Proteínas/administração & dosagem , Soroalbumina Bovina/química , Engenharia Tecidual/métodos , Composição de Medicamentos , Sistemas de Liberação de Medicamentos , Liberação Controlada de Fármacos , Nanopartículas/química , Soroalbumina Bovina/administração & dosagem , Ultrassom
3.
Sensors (Basel) ; 21(12)2021 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-34207534

RESUMO

Recent advances in sensor technology have allowed us to develop many interesting applications and enhance the quality of human life [...].

4.
Sensors (Basel) ; 21(7)2021 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-33805048

RESUMO

High-frequency ultrasound (HFUS) imaging has emerged as an essential tool for pre-clinical studies and clinical applications such as ophthalmic and dermatologic imaging. HFUS imaging systems based on array transducers capable of dynamic receive focusing have considerably improved the image quality in terms of spatial resolution and signal-to-noise ratio (SNR) compared to those by the single-element transducer-based one. However, the array system still suffers from low spatial resolution and SNR in out-of-focus regions, resulting in a blurred image and a limited penetration depth. In this paper, we present synthetic aperture imaging with a virtual source (SA-VS) for an ophthalmic application using a high-frequency convex array transducer. The performances of the SA-VS were evaluated with phantom and ex vivo experiments in comparison with the conventional dynamic receive focusing method. Pre-beamformed radio-frequency (RF) data from phantoms and excised bovine eye were acquired using a custom-built 64-channel imaging system. In the phantom experiments, the SA-VS method showed improved lateral resolution (>10%) and sidelobe level (>4.4 dB) compared to those by the conventional method. The SNR was also improved, resulting in an increased penetration depth: 16 mm and 23 mm for the conventional and SA-VS methods, respectively. Ex vivo images with the SA-VS showed improved image quality at the entire depth and visualized structures that were obscured by noise in conventional imaging.


Assuntos
Neuroimagem , Transdutores , Animais , Bovinos , Imagens de Fantasmas , Razão Sinal-Ruído , Ultrassonografia
5.
Hum Genet ; 139(5): 557-568, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32076829

RESUMO

We provide a Kazakh whole genome sequence (MJS) and analyses with the largest comparative Kazakh genomic data available to date. We found 102,240 novel SNVs and a high level of heterozygosity. ADMIXTURE analysis confirmed a significant proportion of variations in this individual coming from all continents except Africa and Oceania. A principal component analysis showed neighboring Kalmyk, Uzbek, and Kyrgyz populations to have the strongest resemblance to the MJS genome which reflects fairly recent Kazakh history. MJS's mitochondrial haplogroup, J1c2, probably represents an early European and Near Eastern influence to Central Asia. This was also supported by the heterozygous SNPs associated with European phenotypic features and strikingly similar Kazakh ancestral composition inferred by ADMIXTURE. Admixture (f3) analysis showed that MJS's genomic signature is best described as a cross between the Neolithic East Asian (Devil's Gate1) and the Bronze Age European (Halberstadt_LBA1) components rather than a contemporary admixture.


Assuntos
Etnicidade/genética , Genética Populacional , Genoma Humano , Polimorfismo de Nucleotídeo Único , População Branca/genética , China , DNA Mitocondrial , Feminino , Humanos , Cazaquistão , Análise de Componente Principal
6.
Sensors (Basel) ; 19(19)2019 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-31546705

RESUMO

This paper reports the feasibility of Nakagami imaging in monitoring the regeneration process of zebrafish hearts in a noninvasive manner. In addition, spectral Doppler waveforms that are typically used to access the diastolic function were measured to validate the performance of Nakagami imaging. A 30-MHz high-frequency ultrasound array transducer was used to acquire backscattered echo signal for spectral Doppler and Nakagami imaging. The performances of both methods were validated with flow and tissue-mimicking phantom experiments. For in vivo experiments, both spectral Doppler and Nakagami imaging were simultaneously obtained from adult zebrafish with amputated hearts. Longitudinal measurements were performed for five zebrafish. From the experiments, the E/A ratio measured using spectral Doppler imaging increased at 3 days post-amputation (3 dpa) and then decreased to the value before amputation, which were consistent with previous studies. Similar results were obtained from the Nakagami imaging where the Nakagami parameter value increased at 3 dpa and decreased to its original value. These results suggested that the Nakagami and spectral Doppler imaging would be useful techniques in monitoring the regeneration of heart or tissues.


Assuntos
Coração/fisiologia , Regeneração/fisiologia , Ultrassonografia/métodos , Animais , Aumento da Imagem , Peixe-Zebra
7.
Sensors (Basel) ; 18(10)2018 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-30279390

RESUMO

Software-based ultrasound imaging systems provide high flexibility that allows easy and fast adoption of newly developed algorithms. However, the extremely high data rate required for data transfer from sensors (e.g., transducers) to the ultrasound imaging systems is a major bottleneck in the software-based architecture, especially in the context of real-time imaging. To overcome this limitation, in this paper, we present a Binary cLuster (BL) code, which yields an improved compression ratio compared to the exponential Golomb code. Owing to the real-time encoding/decoding features without overheads, the universal code is a good solution to reduce the data transfer rate for software-based ultrasound imaging. The performance of the proposed method was evaluated using in vitro and in vivo data sets. It was demonstrated that the BL-beta code has a good stable lossless compression performance of 20%~30% while requiring no auxiliary memory or storage.

8.
Sensors (Basel) ; 17(4)2017 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-28375165

RESUMO

A power MOSFET linearizer is proposed for a high-voltage power amplifier (HVPA) used in high-frequency pulse-echo instrumentation. The power MOSFET linearizer is composed of a DC bias-controlled series power MOSFET shunt with parallel inductors and capacitors. The proposed scheme is designed to improve the gain deviation characteristics of the HVPA at higher input powers. By controlling the MOSFET bias voltage in the linearizer, the gain reduction into the HVPA was compensated, thereby reducing the echo harmonic distortion components generated by the ultrasonic transducers. In order to verify the performance improvement of the HVPA implementing the power MOSFET linearizer, we measured and found that the gain deviation of the power MOSFET linearizer integrated with HVPA under 10 V DC bias voltage was reduced (-1.8 and -0.96 dB, respectively) compared to that of the HVPA without the power MOSFET linearizer (-2.95 and -3.0 dB, respectively) when 70 and 80 MHz, three-cycle, and 26 dBm input pulse waveforms are applied, respectively. The input 1-dB compression point (an index of linearity) of the HVPA with power MOSFET linearizer (24.17 and 26.19 dBm at 70 and 80 MHz, respectively) at 10 V DC bias voltage was increased compared to that of HVPA without the power MOSFET linearizer (22.03 and 22.13 dBm at 70 and 80 MHz, respectively). To further verify the reduction of the echo harmonic distortion components generated by the ultrasonic transducers, the pulse-echo responses in the pulse-echo instrumentation were compared when using HVPA with and without the power MOSFET linearizer. When three-cycle 26 dBm input power was applied, the second, third, fourth, and fifth harmonic distortion components of a 75 MHz transducer driven by the HVPA with power MOSFET linearizer (-48.34, -44.21, -48.34, and -46.56 dB, respectively) were lower than that of the HVPA without the power MOSFET linearizer (-45.61, -41.57, -45.01, and -45.51 dB, respectively). When five-cycle 20 dBm input power was applied, the second, third, fourth, and fifth harmonic distortions of the HVPA with the power MOSFET linearizer (-41.54, -41.80, -48.86, and -46.27 dB, respectively) were also lower than that of the HVPA without the power MOSFET linearizer (-25.85, -43.56, -49.04, and -49.24 dB, respectively). Therefore, we conclude that the power MOSFET linearizer could reduce gain deviation of the HVPA, thus reducing the echo signal harmonic distortions generated by the high-frequency ultrasonic transducers in pulse-echo instrumentation.

10.
Opt Express ; 23(15): 19166-75, 2015 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-26367579

RESUMO

We demonstrate a jitter noise reduction technique for acoustic radiation force impulse microscopy via photoacoustic detection (PA-ARFI), which promises to be capable of measuring cell mechanics. To reduce the jitter noise induced by Q-switched pulsed laser operated at high repetition frequency, photoacoustic signals from the surface of an ultrasound transducer are aligned by cross-correlation and peak-to-peak detection, respectively. Each method is then employed to measure the displacements of a target sample in an agar phantom and a breast cancer cell due to ARFI application, followed by the quantitative comparison between their performances. The suggested methods for PA-ARFI significantly reduce jitter noises, thus allowing us to measure displacements of a target cell due to ARFI application by less than 3 µm.

11.
Sens Actuators A Phys ; 228: 16-22, 2015 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-25914443

RESUMO

A transducer with an angled and focused aperture for intravascular ultrasound imaging has been developed. The acoustic stack for the angled-focused transducer was made of PMN-PT single crystal with one matching layer, one protective coating layer, and a highly damped backing layer. It was then press-focused to a desired focal length and inserted into a thin needle housing with an angled tip. A transducer with an angled and unfocused aperture was also made, following the same fabrication procedure, to compare the performance of the two transducers. The focused and unfocused transducers were tested to measure their center frequencies, bandwidths, and spatial resolutions. Lateral resolution of the angled-focused transducer (AFT) improved more than two times compared to that of the angled-unfocused transducer (AUT). A tissue-mimicking phantom in water and a rabbit aorta tissue sample in rabbit blood were scanned using AFT and AUT. Imaging with AFT offered improved contrast, over imaging with AUT, of the tissue-mimicking phantom and the rabbit aorta tissue sample by 23 dB and 8 dB, respectively. The results show that AFT has strong potential to provide morphological and pathological information of coronary arteries with high resolution and high contrast.

12.
Gigascience ; 132024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38626723

RESUMO

BACKGROUND: Phenome-wide association studies (PheWASs) have been conducted on Asian populations, including Koreans, but many were based on chip or exome genotyping data. Such studies have limitations regarding whole genome-wide association analysis, making it crucial to have genome-to-phenome association information with the largest possible whole genome and matched phenome data to conduct further population-genome studies and develop health care services based on population genomics. RESULTS: Here, we present 4,157 whole genome sequences (Korea4K) coupled with 107 health check-up parameters as the largest genomic resource of the Korean Genome Project. It encompasses most of the variants with allele frequency >0.001 in Koreans, indicating that it sufficiently covered most of the common and rare genetic variants with commonly measured phenotypes for Koreans. Korea4K provides 45,537,252 variants, and half of them were not present in Korea1K (1,094 samples). We also identified 1,356 new genotype-phenotype associations that were not found by the Korea1K dataset. Phenomics analyses further revealed 24 significant genetic correlations, 14 pleiotropic associations, and 127 causal relationships based on Mendelian randomization among 37 traits. In addition, the Korea4K imputation reference panel, the largest Korean variants reference to date, showed a superior imputation performance to Korea1K across all allele frequency categories. CONCLUSIONS: Collectively, Korea4K provides not only the largest Korean genome data but also corresponding health check-up parameters and novel genome-phenome associations. The large-scale pathological whole genome-wide omics data will become a powerful set for genome-phenome level association studies to discover causal markers for the prediction and diagnosis of health conditions in future studies.


Assuntos
Estudo de Associação Genômica Ampla , Polimorfismo de Nucleotídeo Único , Humanos , Fenótipo , Estudos de Associação Genética , Frequência do Gene , República da Coreia , Genótipo
13.
Opt Express ; 20(3): 3082-90, 2012 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-22330545

RESUMO

Real-time photoacoustic (PA) imaging involves beamforming methods using an assumed fixed sound speed, typically 1540 m/s in soft tissue. This leads to degradation of PA image quality because the true sound speed changes as PA signal propagates through different types of soft tissues: the range from 1450 m/s to 1600 m/s. This paper proposes a new method for estimating an optimal sound speed to enhance the cross-sectional PA image quality. The optimal sound speed is determined when coherent factor with the sound speed is maximized. The proposed method was validated through simulation and ex vivo experiments with microcalcification-contained breast cancer specimen. The experimental results demonstrated that the best lateral resolution of PA images of microcalcifications can be achieved when the optimal sound speed is utilized.


Assuntos
Algoritmos , Doenças Mamárias/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Aumento da Imagem/métodos , Técnicas Fotoacústicas/métodos , Ultrassonografia Mamária/métodos , Humanos
14.
Artigo em Inglês | MEDLINE | ID: mdl-35436190

RESUMO

Implementation of a high-frequency ultrasound (HFUS) beamformer is computationally challenging because of its high sampling rate. This article introduces an efficient beamformer with sub-Nyquist sampling (or bandpass sampling) that is suitable for HFUS imaging. Our approach used channel radio frequency data sampled at bandpass sampling rate (i.e., 4/ 3fc ) and postfiltering-based interpolation to reduce the computational complexity. A polyphase structure for interpolation was used to further reduce the computational burden while maintaining an adequate delay resolution ( δ ). The performance of the proposed beamformer (i.e., 4/ 3fc sampling with sixfold interpolation, δ = 8fc ) was compared with that of the conventional method (i.e., 4fc sampling with fourfold interpolation, δ = 16fc ). Ultrafast coherent compounding imaging was used in simulation, in vitro and in vivo imaging experiments. Axial/lateral resolution and contrast-to-noise ratio (CNR) values were measured for quantitative evaluation. The number of transmit pulse cycles was varied from 1 to 3 using two transducers with different fractional bandwidths (67% and 98%). In the simulation, the proposed and conventional methods showed the similar -6-dB axial beam widths (63.5 and 61.5 µm , respectively) from the two-cycle transmit pulse using the transducer with a bandwidth of 67%. In vitro and in vivo imaging experiments were performed using a Verasonics ultrasound research platform equipped with a high-frequency array transducer (20-46 MHz). The in vitro imaging results using a wire target showed consistent results with the simulation study (i.e., disparity at -6-dB axial resolution). The in vivo feasibility study with a murine mouse model with breast cancer was also performed, and the proposed method yielded a similar image quality compared with the conventional method. From these studies, it was demonstrated that the proposed HFUS beamformer based on the bandpass sampling can substantially reduce the computational complexity while minimizing the loss of spatial resolution for HFUS imaging.


Assuntos
Transdutores , Animais , Simulação por Computador , Camundongos , Imagens de Fantasmas , Ultrassonografia/métodos
15.
IEEE Trans Biomed Eng ; 69(9): 2817-2825, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35226597

RESUMO

OBJECTIVE: Two-dimensional (2D) photoacoustic (PA) imaging based on array transducers provide high spatial resolution in the lateral direction by adopting receive dynamic focusing. However, the quality of PA image is often deteriorated by poor elevational resolution which is achieved by an acoustic lens. To overcome this limitation, we present a three-dimensional (3D) image reconstruction method using a commercial one-dimensional (1D) array transducer. METHODS: In the method, the elevational resolution is improved by applying synthetic aperture focusing (SAF) technique along the elevational direction. For this, a commercially available 1D array transducer with an acoustic lens is modeled and appropriate synthetic focusing delay that can minimize the effect of the acoustic lens is derived by mathematical analysis. RESULTS: From the simulation and experiment results, it was demonstrated that the proposed method can enhance the image quality of PA imaging, i.e., elevational resolution and signal-to-noise ratio (SNR). CONCLUSION: 3D PA images with improved elevational resolution were achieved using a clinical 1D array transducer. SIGNIFICANCE: The presented method may be useful for clinical application such as detecting microcalcification, imaging of tumor vasculature and guidance of biopsy in real time.


Assuntos
Técnicas Fotoacústicas , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Imagens de Fantasmas , Técnicas Fotoacústicas/métodos , Razão Sinal-Ruído , Transdutores
16.
ACS Appl Mater Interfaces ; 14(8): 9987-10000, 2022 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-35176852

RESUMO

Chemical reactions between homogeneous precursors are typically used to synthesize monodisperse nanoparticles with well-controlled size and morphology. It is difficult to predict the evolved nanostructures when using two heterogeneous precursors. In this study, three types of Mo-Te nanoparticles shaped like leaves, spindles, and rice grains (denoted respectively as nanoleaf, nanospindle, and nanorice) were obtained from dextrose-mediated proton-coupled electron transfer reaction between the solid polyoxomolybdate (POM) and the ionic tellurite anion as precursors. All produced nanoparticles had excellent optical absorption in the ultraviolet(UV)-visible(Vis)-near-infrared(NIR) regions, with only slight deviations among them. After confirming nanoparticles' photothermal conversion and photocatalytic activity at multiple wavelengths, the Mo-Te nanorice was tested as a potential agent for cancer treatment due to its minimum toxicity, excellent colloidal stability, and intrinsic anticancer effect. Excellent treatment efficacy and clearance were confirmed in vitro and in vivo. Due to their photoacoustic imaging capability, the injection of pristine nanoparticles could also realize phototheranostics without using additional drugs, probes, or photosensitizers.


Assuntos
Nanopartículas , Neoplasias , Técnicas Fotoacústicas , Humanos , Nanopartículas/química , Neoplasias/diagnóstico por imagem , Neoplasias/tratamento farmacológico , Técnicas Fotoacústicas/métodos , Fototerapia , Medicina de Precisão , Nanomedicina Teranóstica
17.
GigaByte ; 2022: gigabyte51, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36824523

RESUMO

We present LT1, the first high-quality human reference genome from the Baltic States. LT1 is a female de novo human reference genome assembly, constructed using 57× nanopore long reads and polished using 47× short paired-end reads. We utilized 72 GB of Hi-C chromosomal mapping data for scaffolding, to maximize assembly contiguity and accuracy. The contig assembly of LT1 was 2.73 Gbp in length, comprising 4490 contigs with an NG50 value of 12.0 Mbp. After scaffolding with Hi-C data and manual curation, the final assembly has an NG50 value of 137 Mbp and 4699 scaffolds. Assessment of gene prediction quality using Benchmarking Universal Single-Copy Orthologs (BUSCO) identified 89.3% of the single-copy orthologous genes included in the benchmark. Detailed characterization of LT1 suggests it has 73,744 predicted transcripts, 4.2 million autosomal SNPs, 974,616 short indels, and 12,079 large structural variants. These data may be used as a benchmark for further in-depth genomic analyses of Baltic populations.

18.
Mol Cells ; 44(9): 680-687, 2021 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-34588322

RESUMO

Coronavirus disease, COVID-19 (coronavirus disease 2019), caused by SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2), has a higher case fatality rate in European countries than in others, especially East Asian ones. One potential explanation for this regional difference is the diversity of the viral infection efficiency. Here, we analyzed the allele frequencies of a nonsynonymous variant rs12329760 (V197M) in the TMPRSS2 gene, a key enzyme essential for viral infection and found a significant association between the COVID-19 case fatality rate and the V197M allele frequencies, using over 200,000 present-day and ancient genomic samples. East Asian countries have higher V197M allele frequencies than other regions, including European countries which correlates to their lower case fatality rates. Structural and energy calculation analysis of the V197M amino acid change showed that it destabilizes the TMPRSS2 protein, possibly negatively affecting its ACE2 and viral spike protein processing.


Assuntos
COVID-19/genética , COVID-19/mortalidade , Serina Endopeptidases/genética , Povo Asiático , COVID-19/etnologia , Frequência do Gene , Humanos , Modelos Moleculares , Mortalidade , Polimorfismo de Nucleotídeo Único , República da Coreia , Serina Endopeptidases/química , População Branca
19.
Pharmaceutics ; 13(4)2021 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-33801692

RESUMO

Mesenchymal stem cells (MSCs) have been extensively used in the tissue regeneration therapy. Ex vivo therapy with well-differentiated osteogenic cells is known as an efficient treatment for musculoskeletal diseases, including rheumatoid diseases. However, along with its high cost, the current therapy has limitations in terms of restoring bone regeneration procedures. An efficient process for the cell differentiation to obtain a large number of functionalized osteogenic cells is necessary. Therefore, it is strongly recommended to develop strategies to produce sufficient numbers of well-differentiated osteogenic cells from the MSCs. In general, differentiation media with growth factors have been used to facilitate cell differentiation. In the present study, the poly (lactic-co-glycolic acid) (PLGA) nanoparticles incorporating the growth factors were included in the media, resulting in releasing growth factors (dexamethasone and ß-glycerophosphate) in the media in the controlled manner. Stable growth and early differentiation of osteogenic cells were achieved by the PLGA-based growth factor releasing system. Moreover, low intensity pulsed ultrasound was applied to this system to induce cell differentiation process. The results revealed that, as a biomarker at early stage of osteogenic cell differentiation, Lamin A/C nuclear protein was efficiently expressed in the cells growing in the presence of PLGA-based growth factor reservoirs and ultrasound. In conclusion, our results showed that the ultrasound stimulation combined with polymeric nanoparticles releasing growth factors could potentially induce osteogenic cell differentiation.

20.
Front Genet ; 12: 633731, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33633791

RESUMO

The Welfare Genome Project (WGP) provided 1,000 healthy Korean volunteers with detailed genetic and health reports to test the social perception of integrating personal genetic and healthcare data at a large-scale. WGP was launched in 2016 in the Ulsan Metropolitan City as the first large-scale genome project with public participation in Korea. The project produced a set of genetic materials, genotype information, clinical data, and lifestyle survey answers from participants aged 20-96. As compensation, the participants received a free general health check-up on 110 clinical traits, accompanied by a genetic report of their genotypes followed by genetic counseling. In a follow-up survey, 91.0% of the participants indicated that their genetic reports motivated them to improve their health. Overall, WGP expanded not only the general awareness of genomics, DNA sequencing technologies, bioinformatics, and bioethics regulations among all the parties involved, but also the general public's understanding of how genome projects can indirectly benefit their health and lifestyle management. WGP established a data construction framework for not only scientific research but also the welfare of participants. In the future, the WGP framework can help lay the groundwork for a new personalized healthcare system that is seamlessly integrated with existing public medical infrastructure.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA