Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Inorg Chem ; 59(16): 11562-11576, 2020 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-32799505

RESUMO

Organelle-targeting fluorescence probes are valuable because they can provide spatiotemporal information about the trafficking of analytes of interest. The spatiotemporal resolution can be improved by using low-energy emission signals because they are barely contaminated by autofluorescence noises. In this study, we designed and synthesized a deep-red-fluorescent zinc probe (JJ) with a membrane-targeting cholesterol unit. This zinc probe consists of a boron-azadipyrromethene (aza-BODIPY) fluorophore and a zinc receptor that is tethered to a tri(ethylene glycol)-cholesterol chain. In aqueous solutions buffered to pH 7.4, JJ exhibits weak fluorescence with a peak wavelength of 663 nm upon excitation at 622 nm. The addition of ZnCl2 elicits an approximately 5-fold enhancement of the fluorescence emission with a fluorescence dynamic range of 141000. Our electrochemical and picosecond transient photoluminescence investigations indicate that the fluorescence turn-on response is due to the zinc-induced abrogation of the formation of a nonemissive intramolecularly charge-separated species, which occurs with a driving force of 0.98 eV. The fluorescence zinc response was found to be fully reversible and to be unaffected by pH changes or the presence of biological metal ions. These properties are due to tight zinc binding with a dissociation constant of 4 pM. JJ was found to be nontoxic to HeLa cells up to submicromolar concentrations, which enables cellular imaging. Colocalization experiments were performed with organelle-specific stains and revealed that JJ is rapidly internalized into intracellular organelles, including lysosomes and endoplasmic reticula. Unexpectedly, probe internalization was found to permeabilize the cell membrane, which facilitates the influx of exogens such as zinc ions. Such permeabilization does not arise for a control probe without the tri(ethylene glycol)-cholesterol chain (JJC). Our results show that the membrane-targeting cholesterol unit can disrupt membrane integrity.


Assuntos
Colesterol/química , Corantes Fluorescentes/química , Compostos de Boro/química , Membrana Celular/química , Quelantes/química , Células HeLa , Humanos , Espectrofotometria Ultravioleta , Zinco/química
2.
Inorg Chem ; 57(21): 13985-13997, 2018 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-30345759

RESUMO

The study of biological histamine (HA) requires probes capable of ratiometric photoluminescence detection of HA. We discovered that a monocycloplatinated complex having two solvento ligands ([Pt(2-(2-naphthyl)quinolinate)(NCCH3)2]ClO4) could produce ratiometric phosphorescence responses to HA in aerated aqueous solutions buffered to pH 7.4. The HA response was characterized with a hypsochromic shift of an emission peak wavelength from 635 to 567 nm. The corresponding phosphorescence intensity ratio (i.e., I567 nm/ I635 nm) increased from 0.26 to 1.90. Spectroscopic and spectrometric investigations indicated an occurrence of spontaneous displacement of the labile CH3CN ligands with HA. An independently prepared HA adduct supported this notion. The ratiometric phosphorescence responses to HA were highly tolerant to other biological stimuli, including changes in pH and the presence of biometals and biological Lewis bases such as amino acids, nucleosides, biothiols, neurotransmitters, and small molecular metabolites. Of note was the high selectivity toward HA over common biological ligands, including histidine, cysteine, and homocysteine, which was ascribed to tighter HA binding. Our phosphorescence measurements employing Boc-protected derivatives of HA suggested that the bis-chelate motif involving imidazolyl and terminal amino groups was crucial for eliciting the ratiometric phosphorescence signaling. Finally, the bioimaging utility of the HA probe was validated using RAW 264.7 macrophages that were exogenously supplemented with HA or stimulated with thapsigargin to enrich intracellular HA. Ratiometric phosphorescence imaging microscopy experiments demonstrated the ability of the probe for monitoring intracellular HA uptake. In addition, photoluminescence lifetime imaging microscopy techniques could be applied for visualization of HA within the RAW 264.7 cells, because the HA binding elongated the photoluminescence lifetime. Our study demonstrated the promising utility of inner-sphere interactions of phosphorescent Pt(II) complexes for detection of biological HA.

3.
Vet Med Sci ; 10(3): e1425, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38563757

RESUMO

BACKGROUND: Chronic sternal osteomyelitis is a rare condition in felines, with limited reported cases to date. OBJECTIVES: We report the case of a 2-year-old castrated male, domestic shorthair cat, weighing 4.68 kg, that presented with skin openings every 3-4 months, despite skin debridement and reconstruction. METHODS: A subcutaneous dead space larger than the skin defect was detected. Haematological analysis revealed elevated levels of inflammatory markers. Thoracic radiography revealed sternal deformation and suspected osteomyelitis. Computed tomography revealed a fistula extending from the third to the fourth sternebrae. RESULTS: Bone and soft tissue debridement and abscess flushing were performed along with long-term antibiotic therapy. The cat remained recurrence-free throughout an 18-month post-surgery follow-up period. CONCLUSION: To the best of our knowledge, this is the first report of chronic osteomyelitis occurring in a cat's sternebrae and represents the first successful case of its treatment. This case showcases the potential for improved treatment outcomes in similar cases. Understanding and successful treatment of such cases can pave the way for better management of feline osteomyelitis.


Assuntos
Doenças do Gato , Osteomielite , Masculino , Gatos , Animais , Osteomielite/etiologia , Osteomielite/cirurgia , Osteomielite/veterinária , Doenças do Gato/diagnóstico por imagem , Doenças do Gato/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA