Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(13)2022 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-35808431

RESUMO

Building Information Modeling (BIM) has been increasingly used in coordinating the different mechanical, electrical, and plumbing (MEP) services in the construction industries. As the construction industries are slowly adapting to BIM, the use of 2D software may become obsolete in the future as MEP services are technically more complicated to coordinate, due to respective services' codes of practice to follow and limit ceiling height. The 3D MEP designs are easy to visualize before installing the respective MEP services on the construction site to prevent delay in the construction process. The aid of current advanced technology has brought BIM to the next level to reduce manual work through automation. Combining both innovative technology and suitable management methods not only improves the workflow in design coordination, but also decreases conflict on the construction site and lowers labor costs. Therefore, this paper tries to explore possible advance technology in BIM and management strategies that could help MEP services to increase productivity, accuracy, and efficiency with a lower cost of finalizing the design of the building. This will assist the contractors to complete construction works before the targeted schedule and meet the client's expectations.


Assuntos
Indústria da Construção , Engenharia Sanitária , Automação , Humanos , Tecnologia da Informação , Software
2.
Med Biol Eng Comput ; 46(7): 689-99, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18301936

RESUMO

As hemodynamics is widely believed to correlate with anastomotic stenosis in coronary bypass surgery, this paper investigates the flow characteristics and distributions of the hemodynamic parameters (HPs) in a coronary bypass model (which includes both proximal and distal anastomoses), under physiological flow conditions. Disturbed flows (flow separation/reattachment, vertical and secondary flows) as well as regions of high oscillatory shear index (OSI) with low wall shear stress (WSS), i.e., high-OSI-and-low-WSS and low-OSI-and-high-WSS were found in the proximal and distal anastomoses, especially at the toe and heel regions of distal anastomosis, which indicate highly suspected sites for the onset of the atherosclerotic lesions. The flow patterns found in the graft and distal anastomoses of our model at deceleration phases are different from those of the isolated distal anastomosis model. In addition, a huge significant difference in segmental averages of HPs was found between the distal and proximal anastomoses. These findings further suggest that intimal hyperplasia would be more prone to form in the distal anastomosis than in the proximal anastomosis, particularly along the suture line at the toe and heel of distal anastomosis.


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana/etiologia , Oclusão de Enxerto Vascular/etiologia , Modelos Cardiovasculares , Anastomose Cirúrgica , Velocidade do Fluxo Sanguíneo , Humanos , Fluxo Pulsátil
3.
Artif Organs ; 29(8): 620-8, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16048478

RESUMO

The centrifugal blood pump with a magnetically suspended impeller has shown its superiority as compared to other artificial heart pumps. However, there is still insufficient understanding of fluid mechanics related issues in the clearance gap. The design nature of the pump requires sufficient washout in the clearance between the impeller and the stationary pump housing inner surface. In this study, numerical simulations were carried out to investigate the flow fields in the gap of the Kyoto-NTN centrifugal blood pump. The flow patterns in the gap region of the blood pump were presented and regions of high and low velocity were identified. It was found that the radial velocity of the blood in the gap was closely related to the pressure distribution at the exit of the impeller, both the highest pressure gradient and the highest radial velocity in the gap occurred at an angular position of 170 degrees . The mass flow rate in the gap was estimated to be 25.2% of the pump outflow, which is close to the measurement results of a five times enlarged test pump. The wall shear stresses on the gap surface were found to be over 21 Pa and below 300 Pa, which is correspondingly higher than the threshold of thrombi formation and is lower than the shearing threshold of red blood cells. Comparison of the 1 : 1 simulation model with the measurement results on a five times enlarged test pump indicates that there are some differences in the resulting radial velocity distributions in the gap and thus the washout mechanism. Two symmetrical high washout regions at both the cutwater and splitter plate were observed in the simulation instead of a single washout region at the splitter plate found in the experimental study. This may be due to the scaling effect of the enlarged test pump; also the medium used in the experiment is different from the simulation.


Assuntos
Coração Artificial , Hemorreologia/instrumentação , Fenômenos Biomecânicos , Centrifugação , Simulação por Computador , Desenho de Equipamento , Humanos , Magnetismo , Modelos Cardiovasculares
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA