1.
Int Endod J ; 51(11): 1271-1278, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29637579

RESUMO

AIM: To evaluate the presence and propagation of defects and their effects on surfaces of nickel-titanium (NiTi) instruments using noncontact, three-dimensional optical profilometry, and to assess the accuracy of this method of investigation. METHODOLOGY: The flute surface areas of instruments from two commercial instrumentation systems, namely Reciproc R25 (n = 5) and WaveOne Primary (n = 5), were assessed and compared before and after performing two instrumentation cycles in simulated root canals in clear resin blocks. All the analyses were conducted on areas measuring 211 × 211 µm, located 3 mm from the tips of the instruments. A quantitative analysis was conducted before and after the first and second instrumentation cycles, using the Sa (average roughness over the measurement field), Sq (root mean square roughness) and Sz (average height over the measurement field) amplitude parameters. All the data were submitted to statistical analysis at a 5% level of significance. RESULTS: There was a significant increase (P = 0.007) in wear in both groups, especially between baseline and the second instrumentation cycle, with significantly higher wear values being observed on WaveOne instruments (Sz median values = 33.68 and 2.89 µm, respectively, for WO and RP groups). A significant increase in surface roughness (P = 0.016 and P = 0.008, respectively, for Sa and Sq) was observed in both groups from the first to the second instrumentation cycle, mostly in WaveOne specimens. Qualitative analysis revealed a greater number of defects on the flute topography of all the instruments after use. CONCLUSIONS: More defects were identified in WaveOne Primary instruments compared to Reciproc R25, irrespective of the evaluation stage. The investigation method provided an accurate, repeatable and reproducible assessment of NiTi instruments at different time-points.


Assuntos
Níquel/química , Preparo de Canal Radicular/instrumentação , Tratamento do Canal Radicular/instrumentação , Titânio/química , Ligas Dentárias/química , Instrumentos Odontológicos , Cavidade Pulpar , Endodontia/instrumentação , Desenho de Equipamento , Falha de Equipamento , Humanos , Imageamento Tridimensional/métodos , Teste de Materiais , Reprodutibilidade dos Testes , Rotação , Propriedades de Superfície , Fatores de Tempo
2.
Int Endod J ; 50(2): 143-152, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26825427

RESUMO

The aim of this review was to provide a detailed analysis of the literature concerning the correlation between different movement kinematics and the cyclic fatigue resistance of NiTi rotary endodontic instruments. From June 2014 to August 2015, four independent reviewers comprehensively and systematically searched the Medline (PubMed), EMBASE, Web of Science, Scopus and Google Scholar databases for works published since January 2005, using the following search terms: endodontics; nickel-titanium rotary files; continuous rotation; reciprocating motion; cyclic fatigue. In addition to the electronic searches, manual searches were performed to include articles listed in the reference sections of high-impact published articles that were not indexed in the databases. Laboratory studies in English language were considered for this review. The electronic and manual searches resulted in identification of 75 articles. Based on the inclusion criteria, 32 articles were selected for analysis of full-text copies. Specific analysis was then made of 20 articles that described the effects of reciprocating and continuous movements on cyclic fatigue of the instruments. A wide range of testing conditions and methodologies have been used to compare the cyclic fatigue resistance of rotary endodontic instruments. Most studies report that reciprocating motion improves the fatigue resistance of endodontic instruments, compared to continuous rotation, independent of other variables such as the speed of rotation, the angle or radius of curvature of simulated canals, geometry and taper, or the surface characteristics of the NiTi instruments.


Assuntos
Ligas , Endodontia/instrumentação , Movimento , Rotação
3.
Int Endod J ; 50(9): 902-909, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27696455

RESUMO

AIM: To describe a new method for the assessment of nanoscale alterations in the surface topography of nickel-titanium endodontic instruments using a high-resolution optical method and to verify the accuracy of the technique. METHODOLOGY: Noncontact three-dimensional optical profilometry was used to evaluate defects on a size 25, .08 taper reciprocating instrument (WaveOne® ), which was subjected to a cyclic fatigue test in a simulated root canal in a clear resin block. For the investigation, an original procedure was established for the analysis of similar areas located 3 mm from the tip of the instrument before and after canal preparation to enable the repeatability and reproducibility of the measurements with precision. All observations and analysis were taken in areas measuring 210 × 210 µm provided by the software of the equipment. RESULTS: The three-dimensional high-resolution image analysis showed clear alterations in the surface topography of the examined cutting blade and flute of the instrument, before and after use, with the presence of surface irregularities such as deformations, debris, grooves, cracks, steps and microcavities. CONCLUSIONS: Optical profilometry provided accurate qualitative nanoscale evaluation of similar surfaces before and after the fatigue test. The stability and repeatability of the technique enables a more comprehensive understanding of the effects of wear on the surface of endodontic instruments.


Assuntos
Ligas , Instrumentos Odontológicos , Teste de Materiais/métodos , Endodontia/instrumentação , Imageamento Tridimensional , Propriedades de Superfície
4.
Int Endod J ; 39(10): 779-84, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16948663

RESUMO

AIM: To compare automated and manual instrumentation techniques for removing filling material from root canal walls during root canal retreatment. METHODOLOGY: One hundred extracted human single-rooted teeth were root filled and stored. Specimens were divided into two groups: group A, Endofill plus gutta-percha; group B, Sealer 26 plus gutta-percha. The filling material was removed using the following techniques: group I - Gates-Glidden and K-type files; group II - ProFile; group III - ProTaper; group IV - K3; group V- Micro Mega Hero 642. The remaining filling debris on the root canal walls were assessed radiographically, images were digitized and analysed using Image ProPlus software. The roots were split for evaluation in a stereomicroscope by epiluminescence and photomicrographs were taken for further analysis. The area covered with filling debris was analysed by means of Student's t-test to compare the evaluation methods. The student's t-test was also used to compare the removal of filling materials. An anova test was applied to compare the different techniques (P < 0.05). RESULTS: A significant difference occurred between radiographic and photomicrographic evaluation methods (P < 0.05). No significant difference was observed between the filling materials on terms of their removal (P > 0.05). Manual instrumentation left more filling debris on the root canal walls when compared to K3 (P < 0.05) and ProTaper (P < 0.01). CONCLUSIONS: A photomicrographic method by epiluminescence was more effective than the radiographic method to evaluate filling debris. There was no significant difference between the filling materials in terms of their removal. K3 and ProTaper were more efficient than manual instrumentation.


Assuntos
Instrumentos Odontológicos , Preparo de Canal Radicular/instrumentação , Bismuto , Hidróxido de Cálcio , Guta-Percha , Humanos , Fotomicrografia , Radiografia Dentária , Retratamento , Materiais Restauradores do Canal Radicular