RESUMO
Non-healing wounds are a major threat to public health throughout the United States. Tissue healing is complex multifactorial process that requires synchronicity of several cell types. Endolysosomal trafficking, which contributes to various cell functions from protein degradation to plasma membrane repair, is an understudied process in the context of wound healing. The lysosomal trafficking regulator protein (LYST) is an essential protein of the endolysosomal system through an indeterminate mechanism. In this study, we examine the impact of impaired LYST function both in vitro with primary LYST mutant fibroblasts as well as in vivo with an excisional wound model. The wound model shows that LYST mutant mice have impaired wound healing in the form of delayed epithelialization and collagen deposition, independent of macrophage infiltration and polarisation. We show that LYST mutation confers a deficit in MCP-1, IGF-1, and IGFBP-2 secretion in beige fibroblasts, which are critical factors in normal wound healing. Identifying the mechanism of LYST function is important for understanding normal wound biology, which may facilitate the development of strategies to address problem wound healing.
Assuntos
Lisossomos , Cicatrização , Animais , Colágeno , Fibroblastos , Camundongos , ReepitelizaçãoRESUMO
Lysosomes and lysosome related organelles (LROs) are dynamic organelles at the intersection of various pathways involved in maintaining cellular hemostasis and regulating cellular functions. Vesicle trafficking of lysosomes and LROs are critical to maintain their functions. The lysosomal trafficking regulator (LYST) is an elusive protein important for the regulation of membrane dynamics and intracellular trafficking of lysosomes and LROs. Mutations to the LYST gene result in Chédiak-Higashi syndrome, an autosomal recessive immunodeficiency characterized by defective granule exocytosis, cytotoxicity, etc. Despite eight decades passing since its initial discovery, a comprehensive understanding of LYST's function in cellular biology remains unresolved. Accumulating evidence suggests that dysregulation of LYST function also manifests in other disease states. Here, we review the available literature to consolidate available scientific endeavors in relation to LYST and discuss its relevance for immunomodulatory therapies, regenerative medicine and cancer applications.
Assuntos
Lisossomos , Proteínas de Transporte Vesicular , Humanos , Lisossomos/metabolismo , Proteínas de Transporte Vesicular/metabolismo , Proteínas de Transporte Vesicular/genética , Animais , Síndrome de Chediak-Higashi/genética , Transporte Proteico , MutaçãoRESUMO
Capsular contracture as a result of the foreign body response (FBR) is a common issue after implant-based breast reconstruction, affecting up to 20% of patients. New evidence suggests that tamoxifen may mitigate the FBR. C57BL/6 female mice were treated with daily tamoxifen or control injections and implanted with bilateral silicone implants in the submammary glandular plane. Implants were removed en bloc after 2 weeks and the implant capsules were evaluated histologically. Tamoxifen treatment decreased capsule thickness, decreased the number of αSMA+ cells (477 ± 156 cells/mm control vs 295 ± 121 cells/mm tamoxifen, p = 0.005 unpaired t test), and decreased CD31+ cells (173.9 ± 96.1 cells/mm2 control vs 106.3 ± 51.8 cells/mm2 tamoxifen, p = 0.043 unpaired t test). There were similar amounts of pro- and anti-inflammatory macrophages (iNOS 336.1 ± 226.3 cells/mm control vs 290.6 ± 104.2 cells/mm tamoxifen, p > 0.999 Mann-Whitney test and CD163 136.6 ± 76.4 cells/mm control vs 94.1 ± 45.9 cells/mm tamoxifen, p = 0.108 unpaired t test). Tamoxifen treatment in the mouse silicone breast implant model decreased capsule formation through modulation of myofibroblasts, neovascularization, and collagen deposition. Tamoxifen may be useful for reducing or preventing capsule formation in clinical breast implantations.
RESUMO
Background: Tissue-engineered vascular grafts (TEVGs) have the potential to advance the surgical management of infants and children requiring congenital heart surgery by creating functional vascular conduits with growth capacity. Methods: Herein, we used an integrative computational-experimental approach to elucidate the natural history of neovessel formation in a large animal preclinical model; combining an in vitro accelerated degradation study with mechanical testing, large animal implantation studies with in vivo imaging and histology, and data-informed computational growth and remodeling models. Results: Our findings demonstrate that the structural integrity of the polymeric scaffold is lost over the first 26 weeks in vivo, while polymeric fragments persist for up to 52 weeks. Our models predict that early neotissue accumulation is driven primarily by inflammatory processes in response to the implanted polymeric scaffold, but that turnover becomes progressively mechano-mediated as the scaffold degrades. Using a lamb model, we confirm that early neotissue formation results primarily from the foreign body reaction induced by the scaffold, resulting in an early period of dynamic remodeling characterized by transient TEVG narrowing. As the scaffold degrades, mechano-mediated neotissue remodeling becomes dominant around 26 weeks. After the scaffold degrades completely, the resulting neovessel undergoes growth and remodeling that mimicks native vessel behavior, including biological growth capacity, further supported by fluid-structure interaction simulations providing detailed hemodynamic and wall stress information. Conclusions: These findings provide insights into TEVG remodeling, and have important implications for clinical use and future development of TEVGs for children with congenital heart disease.
RESUMO
Tissue engineered vascular grafts hold promise for the creation of functional blood vessels from biodegradable scaffolds. Because the precise mechanisms regulating this process are still under investigation, inducible genetic mouse models are an important and widely used research tool. However, here we describe the importance of challenging the baseline assumption that tamoxifen is inert when used as a small molecule inducer in the context of cardiovascular tissue engineering. Employing a standard inferior vena cava vascular interposition graft model in C57BL/6 mice, we discovered differences in the immunologic response between control and tamoxifen-treated animals, including occlusion rate, macrophage infiltration and phenotype, the extent of foreign body giant cell development, and collagen deposition. Further, differences were noted between untreated males and females. Our findings demonstrate that the host-response to materials commonly used in cardiovascular tissue engineering is sex-specific and critically impacted by exposure to tamoxifen, necessitating careful model selection and interpretation of results.
Assuntos
Tamoxifeno , Engenharia Tecidual , Animais , Prótese Vascular , Células da Medula Óssea , Feminino , Camundongos , Camundongos Endogâmicos C57BL , Alicerces TeciduaisRESUMO
Wall stress is often lower in tissue-engineered constructs than in comparable native tissues due to the use of stiff polymeric materials having thicker walls. In this work, we sought to design a murine arterial graft having a more favorable local mechanical environment for the infiltrating cells; we used electrospinning to enclose a compliant inner core of poly(glycerol sebacate) with a stiffer sheath of poly(caprolactone) to reduce the potential for rupture. Two scaffolds were designed that differed in the thickness of the core as previous computational simulations found that circumferential wall stresses could be increased in the core toward native values by increasing the ratio of the core:sheath. Our modified electrospinning protocols reduced swelling of the core upon implantation and eliminated residual stresses in the sheath, both of which had contributed to the occlusion of implanted grafts during pilot studies. For both designs, a subset of implanted grafts occluded due to thrombosis or ruptured due to suspected point defects in the sheath. However, there were design-based differences in collagen content and mechanical behavior during early remodeling of the patent samples, with the thinner-core scaffolds having more collagen and a stiffer behavior after 12 weeks of implantation than the thicker-core scaffolds. By 24 weeks, the thicker-core scaffolds also became stiff, with similar amounts of collagen but increased smooth muscle cell and elastin content. These data suggest that increasing wall stress toward native values may provide a more favorable environment for normal arterial constituents to form despite the overall stiffness of the construct remaining elevated due to the absolute increase in load-bearing constituents.
Assuntos
Engenharia Tecidual , Alicerces Teciduais , Animais , Artérias , Prótese Vascular , Colágeno , Elastina , Camundongos , PoliésteresRESUMO
In the field of congenital heart surgery, tissue-engineered vascular grafts (TEVGs) are a promising alternative to traditionally used synthetic grafts. Our group has pioneered the use of TEVGs as a conduit between the inferior vena cava and the pulmonary arteries in the Fontan operation. The natural history of graft remodeling and its effect on hemodynamic performance has not been well characterized. In this study, we provide a detailed analysis of the first U.S. clinical trial evaluating TEVGs in the treatment of congenital heart disease. We show two distinct phases of graft remodeling: an early phase distinguished by rapid changes in graft geometry and a second phase of sustained growth and decreased graft stiffness. Using clinically informed and patient-specific computational fluid dynamics (CFD) simulations, we demonstrate how changes to TEVG geometry, thickness, and stiffness affect patient hemodynamics. We show that metrics of patient hemodynamics remain within normal ranges despite clinically observed levels of graft narrowing. These insights strengthen the continued clinical evaluation of this technology while supporting recent indications that reversible graft narrowing can be well tolerated, thus suggesting caution before intervening clinically.
RESUMO
Objective: Despite the development of a number of treatment modalities, scarring remains common postburn injury. To reduce burn scarring, pressure garment therapy has been widely utilized but is complicated by low patient adherence. To improve adherence, reduced hours of daily garment wear has been proposed. Approach: To examine the efficacy of pressure garment therapy at reduced durations of daily wear, a porcine burn-excise-autograft model was utilized. Grafted burns were treated with pressure garments (20 mmHg) for 8, 16, or 24 h of daily wear with untreated burns serving as controls. Scar area, thickness, biomechanical properties, and tissue structure were assessed over time. Results: All treatment groups reduced scar thickness and contraction versus controls and improved scar pliability and elasticity. Pressure garments worn 24 h per day significantly reduced contraction versus the 8- and 16-h groups and prevented alignment of collagen within the dermis. Innovation: Though pressure garment therapy is prescribed for use 23 h per day, the need for almost continuous use has not been previously examined. Adjustable, low-fatigue pressure garments were developed for this porcine study to examine the role of daily duration of wear without confounding factors such as garment fatigue and patient adherence. Conclusion: For maximum efficacy, pressure garments should be worn 23 to 24 h per day; however, garments worn as little as 8 h per day significantly improve scar outcomes versus no treatment.
Assuntos
Queimaduras/complicações , Queimaduras/terapia , Cicatriz Hipertrófica/etiologia , Cicatriz Hipertrófica/terapia , Vestuário , Bandagens Compressivas , Animais , Autoenxertos , Fenômenos Biomecânicos , Modelos Animais de Doenças , Cooperação do Paciente , Suínos , Transplante Autólogo , Resultado do TratamentoRESUMO
Tissue engineered vascular grafts (TEVGs) are a promising technology, but are hindered by occlusion. Seeding with bone-marrow derived mononuclear cells (BM-MNCs) mitigates occlusion, yet the precise mechanism remains unclear. Seeded cells disappear quickly and potentially mediate an anti-inflammatory effect through paracrine signaling. Here, a series of reciprocal genetic TEVG implantations plus recombinant protein treatment is reported to investigate what role interleukin-10, an anti-inflammatory cytokine, plays from both host and seeded cells. TEVGs seeded with BM-MNCs from wild-type and IL-10 KO mice, plus unseeded grafts, are implanted into wild-type and IL-10 KO mice. Wild-type mice with unseeded grafts also receive recombinant IL-10. Serial ultrasound evaluates occlusion and TEVGs are harvested at 14 d for immunohistochemical analysis. TEVGs in IL-10 KO mice have significantly higher occlusion incidence compared to wild-type mice attributed to acute (<3 d) thrombosis. Cell seeding rescues TEVGs in IL-10 KO mice comparable to wild-type patency. IL-10 from the host and seeded cells do not significantly influence graft inflammation and macrophage phenotype, yet IL-10 treatment shows interesting biologic effects including decreasing cell proliferation and increasing M2 macrophage polarization. IL-10 from the host is critical for preventing TEVG thrombosis and seeded BM-MNCs exert a significant anti-thrombotic effect in IL-10 KO mice.
Assuntos
Prótese Vascular , Trombose , Animais , Interleucina-10/genética , Camundongos , Trombose/prevenção & controle , Engenharia TecidualRESUMO
Tissue engineered vascular grafts (TEVGs) using scaffolds fabricated from braided poly(glycolic acid) (PGA) fibers coated with poly(glycerol sebacate) (PGS) are developed. The approach relies on in vivo tissue engineering by which neotissue forms solely within the body after a scaffold has been implanted. Herein, the impact of altering scaffold braid design and scaffold coating on neotissue formation is investigated. Several combinations of braiding parameters are manufactured and evaluated in a Beige mouse model in the infrarenal abdominal aorta. Animals are followed with 4D ultrasound analysis, and 12 week explanted vessels are evaluated for biaxial mechanical properties as well as histological composition. Results show that scaffold parameters (i.e., braiding angle, braiding density, and presence of a PGS coating) have interdependent effects on the resulting graft performance, namely, alteration of these parameters influences levels of inflammation, extracellular matrix production, graft dilation, neovessel distensibility, and overall survival. Coupling carefully designed in vivo experimentation with regression analysis, critical relationships between the scaffold design and the resulting neotissue that enable induction of favorable cellular and extracellular composition in a controlled manner are uncovered. Such an approach provides a potential for fabricating scaffolds with a broad range of features and the potential to manufacture optimized TEVGs.
Assuntos
Prótese Vascular , Engenharia Tecidual , Animais , Matriz Extracelular , Camundongos , Alicerces TeciduaisRESUMO
We developed a tissue-engineered vascular graft (TEVG) for use in children and present results of a U.S. Food and Drug Administration (FDA)-approved clinical trial evaluating this graft in patients with single-ventricle cardiac anomalies. The TEVG was used as a Fontan conduit to connect the inferior vena cava and pulmonary artery, but a high incidence of graft narrowing manifested within the first 6 months, which was treated successfully with angioplasty. To elucidate mechanisms underlying this early stenosis, we used a data-informed, computational model to perform in silico parametric studies of TEVG development. The simulations predicted early stenosis as observed in our clinical trial but suggested further that such narrowing could reverse spontaneously through an inflammation-driven, mechano-mediated mechanism. We tested this unexpected, model-generated hypothesis by implanting TEVGs in an ovine inferior vena cava interposition graft model, which confirmed the prediction that TEVG stenosis resolved spontaneously and was typically well tolerated. These findings have important implications for our translational research because they suggest that angioplasty may be safely avoided in patients with asymptomatic early stenosis, although there will remain a need for appropriate medical monitoring. The simulations further predicted that the degree of reversible narrowing can be mitigated by altering the scaffold design to attenuate early inflammation and increase mechano-sensing by the synthetic cells, thus suggesting a new paradigm for optimizing next-generation TEVGs. We submit that there is considerable translational advantage to combined computational-experimental studies when designing cutting-edge technologies and their clinical management.
Assuntos
Prótese Vascular , Constrição Patológica , Engenharia Tecidual , Animais , Criança , Constrição Patológica/terapia , Humanos , Ovinos , Estados UnidosRESUMO
BACKGROUND: Pressure garment therapy, used for reduction of postburn scarring, is commonly initiated after complete healing of the wound or autograft. Although some clinicians have suggested that earlier treatment may improve outcomes, the effect of early initiation of therapy has not been studied in a controlled environment. METHODS: Full-thickness burns were created on red Duroc pigs, burn eschar was excised, and the wound bed was grafted with split-thickness autografts. Grafts were treated with pressure garments immediately, 1 week (early), or 5 weeks (delayed) after grafting with nontreated grafts as controls. Scar morphology, biomechanics, and gene expression were measured at multiple time points up to 17 weeks after grafting. RESULTS: Grafts that received pressure within 1 week after grafting exhibited no reduction in engraftment rates. Immediate and early application of pressure resulted in scars with decreased contraction, reduced scar thickness, and improved biomechanics compared with controls. Pressure garment therapy did not alter expression of collagen I, collagen III, or transforming growth factor ß1 at the time points investigated; however, expression of matrix metalloproteinase 1 was significantly elevated in the immediate pressure garment therapy group at week 3, whereas the delayed pressure garment therapy and control groups approached baseline levels at this time point. CONCLUSIONS: Early application of pressure garments is safe and effective for reducing scar thickness and contraction and improving biomechanics. This preclinical study suggests that garments should be applied as soon as possible after grafting to achieve greatest benefit, although clinical studies are needed to validate the findings in humans.
Assuntos
Queimaduras/terapia , Cicatriz/prevenção & controle , Bandagens Compressivas , Transplante de Pele/métodos , Cicatrização/fisiologia , Animais , Fenômenos Biomecânicos , Biópsia por Agulha , Queimaduras/patologia , Cicatriz/patologia , Terapia Combinada , Modelos Animais de Doenças , Imuno-Histoquímica , Escala de Gravidade do Ferimento , Cuidados Pós-Operatórios/métodos , Distribuição Aleatória , Suínos , Fatores de Tempo , Transplante Autólogo/métodosRESUMO
Pressure garment therapy is often prescribed to improve scar properties following full-thickness burn injuries. Pressure garment therapy is generally recommended for long periods of time following injury (1-2 years), though it is plagued by extremely low patient compliance. The goal of this study was to examine the effects of early cessation of pressure garment therapy on scar properties. Full-thickness burn injuries were created along the dorsum of red Duroc pigs. The burn eschar was excised and wound sites autografted with split-thickness skin. Scars were treated with pressure garments within 1 week of injury and pressure was maintained for either 29 weeks (continuous pressure) or for 17 weeks followed by cessation of pressure for an additional 12 weeks (pressure released); scars receiving no treatment served as controls. Scars that underwent pressure garment therapy were significantly smoother and less contracted with decreased scar height compared to control scars at 17 weeks. These benefits were maintained in the continuous pressure group until week 29. In the pressure released group, grafts significantly contracted and became more raised, harder and rougher after the therapy was discontinued. Pressure cessation also resulted in large changes in collagen fiber orientation and increases in collagen fiber thickness. The results suggest that pressure garment therapy effectively improves scar properties following severe burn injury; however, early cessation of the therapy results in substantial loss of these improvements.