Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Neuroimage ; 299: 120796, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39153523

RESUMO

PURPOSE: In this study, the objectification of the subjective perception of loudness was investigated using electroencephalography (EEG). In particular, the emergence of objective markers in the domain of the acoustic discomfort threshold was examined. METHODS: A cohort of 27 adults with normal hearing, aged between 18 and 30, participated in the study. The participants were presented with 500 ms long noise stimuli via in-ear headphones. The acoustic signals were presented with sound levels of [55, 65, 75, 85, 95 dB]. After each stimulus, the subjects provided their subjective assessment of the perceived loudness using a colored scale on a touchscreen. EEG signals were recorded, and afterward, event-related potentials (ERPs) locked to sound onset were analyzed. RESULTS: Our findings reveal a linear dependency between the N100 component and both the sound level and the subjective loudness categorization of the sound. Additionally, the data demonstrated a nonlinear relationship between the P300 potential and the sound level as well as for the subjective loudness rating. The P300 potential was elicited exclusively when the stimuli had been subjectively rated as "very loud" or "too loud". CONCLUSION: The findings of the present study suggest the possibility of the identification of the subjective uncomfortable loudness level by objective neural parameters.


Assuntos
Eletroencefalografia , Percepção Sonora , Humanos , Adulto , Masculino , Feminino , Eletroencefalografia/métodos , Adulto Jovem , Percepção Sonora/fisiologia , Adolescente , Potenciais Evocados P300/fisiologia , Estimulação Acústica , Potenciais Evocados Auditivos/fisiologia , Encéfalo/fisiologia , Potenciais Evocados/fisiologia
2.
Artigo em Inglês | MEDLINE | ID: mdl-39179912

RESUMO

OBJECTIVE: The goal of the study was to determine the short- and long-term outcome of health-related quality of life (HRQoL) in adults implanted with a Vibrant Soundbridge (VSB). METHODS: Twenty-one adults (8 females, 13 males; mean age at implantation: 57 ±10 years) who received a unilateral VSB for combined or conductive hearing loss, were administered two questionnaires: the Nijmegen Cochlear Implant Questionnaire (NCIQ) as a measure of hearing-specific HRQoL, and the Health Utility Index 3 (HUI 3) as a measure of generic HRQoL. The questionnaires were administered before implantation and three, six, 12 and 24 months after processor activation. RESULTS: The NCIQ total score raised significantly from 62 points before implantation to 76 points at three months after processor activation (p < 0.005). Thereafter, no significant increases occurred anymore. The HUI 3 multi-attribute score (MAUS) increased from 0.59 before implantation to 0.70 at three months and at six months after processor activation and then declined slightly to 0.68 at 24 months after processor activation. Similar values were observed with the HUI 3 single-attribute score (SAUS) of Hearing. The increases of the HUI 3 scores were not statistically significant, but all pre-post-implantation differences were clinically relevant. DISCUSSION: VSB recipients experienced a quick improvement of their HRQoL. After just three months of device use, a significant improvement of hearing-specific HRQoL and a clinically relevant improvement of generic HRQoL were seen. After three months, no essential changes of HRQoL occurred in our sample, suggesting that the achieved level of HRQoL may remain stable in the long term.

3.
Eur Arch Otorhinolaryngol ; 281(1): 141-151, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37442819

RESUMO

PURPOSE: The Vibrant Soundbridge (VSB) is an established active-middle-ear-implant for patients with moderate-to-profound hearing-loss. This surgery is referred to as "Vibroplasty". Sufficient transfer of the VSB's floating-mass-transducers (FMT) energy to the inner ear is a crucial factor influencing the coupling-quality (CQ). However, assessing CQ is hamper by two issues: the method of CQ-assessment itself and the method of FMT-fixation during Vibroplasty. METHODS: This prospective study explored the influence of intraoperative auditory-brainstem-response (+ ABR) measurements and various fixation methods on postoperative CQ after Vibroplasty as compared to matched-patients after Vibroplasty without intraoperative ABR (-ABR). Propensity-score-matching was performed based on preoperative bone-conduction-pure-tone-average-3 (BC-PTA3) at 1-, 2- and 4 kHz. Primary outcome parameters were postoperative CQ-PTA3, intraoperative ABR threshold for various fixation methods and postoperative BC-PTA3. RESULTS: A total of 28 patients were included, of which 14 were + ABR. Preoperative BC-PTA3, sex, age, and number of previous surgeries did not differ significantly between groups (all p > 0.301). Mean postoperative CQ-PTA3 was significantly better for + ABR (1.8 vs. 12.3 dB-HL; p = 0.006). Mean intraoperative ABR threshold was superior for cartilage-counter-bearing and cartilage-housing compared to additional fixation with injectable-platelet-rich- fibrin (53 vs. 56 & 57 dB-HL, respectively; p = 0.04; η2 = 0.33). Mean postoperative BC-PTA3 did not significantly differ between patients (41.4 vs. 41.8 dB-HL; p = 0.77). A total of 7% of the patients required intraoperative readjustment of the FMT based on unsatisfactory intraoperative ABR threshold. CONCLUSION: Intraoperative ABR measurement resulted in significantly better postoperative CQ. Cartilage-counter-bearing and cartilage-housing were observed to have superior CQ. A total of 7% of the patients could be spared revision-Vibroplasty due to intraoperative ABR measurement.


Assuntos
Perda Auditiva Condutiva-Neurossensorial Mista , Prótese Ossicular , Humanos , Perda Auditiva Condutiva-Neurossensorial Mista/cirurgia , Estudos Prospectivos , Potenciais Evocados Auditivos do Tronco Encefálico , Limiar Auditivo/fisiologia , Resultado do Tratamento
4.
Artigo em Inglês | MEDLINE | ID: mdl-39078472

RESUMO

PURPOSE: To evaluate the diagnostic performance (DP) of the high-resolution contrast computed tomography (HR-contrast-CT) based Neck-Persistency-Net in distinguishing vital from non-vital persistent cervical lymph nodes (pcLNs) in patients with advanced head and neck squamous cell carcinoma (HNSCC) following primary concurrent chemoradiotherapy (CRT) with [18F]-fluorodeoxyglucose positron emission tomography and high-resolution contrast-enhanced computed tomography ([18F]FDG-PET-CT). Furthermore, the Neck-Persistency-Net's potential to justify omitting post-CRT neck dissection (ND) without risking treatment delays or preventing unnecessary surgery was explored. METHODS: All HNSCC patients undergoing primary CRT followed by post-CRT-ND for pcLNs recorded in the institutional HNSCC registry were analyzed. The Neck-Persistency-Net DP was explored for three scenarios: balanced performance (BalPerf), optimized sensitivity (OptSens), and optimized specificity (OptSpec). Histopathology of post-CRT-ND served as a reference. RESULTS: Among 68 included patients, 11 were female and 32 had vital pcLNs. The Neck-Persistency-Net demonstrated good DP with an area under the curve of 0.82. For BalPerf, both sensitivity and specificity were 78%; for OptSens (90%), specificity was 62%; for OptSpec (95%), sensitivity was 54%. Limiting post-CRT-ND to negative results would have delayed treatment in 27%, 40%, and 7% for BalPerf, OptSens and OptSpec, respectively, versus 23% for [18F]FDG-PET-CT. Conversely, restricting post-CRT-ND to positive results would have prevented unnecessary post-CRT-ND in 78%, 60%, and 95% for BalPerf, OptSens and OptSpec, respectively, versus 55% for [18F]FDG-PET-CT. CONCLUSION: The DP of the Neck-Persistency-Net was comparable to [18F]-FDG-PET-CT. Depending on the chosen decision boundary, the potential to justify the omission of post-CRT-ND without risking treatment delays in false negative findings or reliably prevent unnecessary surgery in false positive findings outperforms the [18F]-FDG-PET-CT.

5.
Eur Arch Otorhinolaryngol ; 280(4): 1565-1579, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36625869

RESUMO

AIM: This European multicentric study aimed to prove safety and performance of the Bonebridge BCI 602 in children and adults suffering from either conductive hearing loss (CHL), mixed hearing loss (MHL), or single-sided sensorineural deafness (SSD). METHODS: 33 patients (13 adults and 10 children with either CHL or MHL and 10 patients with SSD) in three study groups were included. Patients were their own controls (single-subject repeated measures), comparing the unaided or pre-operative to the 3-month post-operative outcomes. Performance was evaluated by sound field thresholds (SF), word recognition scores (WRS) and/or speech reception thresholds in quiet (SRT) and in noise (SNR). Safety was demonstrated with a device-specific surgical questionnaire, adverse event reporting and stable pure-tone measurements. RESULTS: The Bonebridge BCI 602 significantly improved SF thresholds (+ 25.5 dB CHL/MHL/SSD), speech intelligibility in WRS (+ 68.0% CHL/MHL) and SRT in quiet (- 16.5 dB C/MHL) and in noise (- 3.51 dB SNR SSD). Air conduction (AC) and bone conduction (BC) thresholds remained stable over time. All adverse events were resolved, with none unanticipated. Mean audio processor wearing times in hours [h] per day for the CHL/MHL group were ~ 13 h for adults, ~ 11 h for paediatrics and ~ 6 h for the SSD group. The average surgical length was 57 min for the CHL/MHL group and 42 min for the SSD group. The versatility of the BCI 602 (reduced drilling depth and ability to bend the transition for optimal placement) allows for treatment of normal, pre-operated and malformed anatomies. All audiological endpoints were reached. CONCLUSIONS: The Bonebridge BCI 602 significantly improved hearing thresholds and speech understanding. Since implant placement follows the patient's anatomy instead of the shape of the device and the duration of surgery is shorter than with its predecessor, implantation is easier with the BCI 602. Performance and safety were proven for adults and children as well as for the CHL/MHL and SSD indications 3 months post-operatively.


Assuntos
Interfaces Cérebro-Computador , Surdez , Auxiliares de Audição , Perda Auditiva Condutiva-Neurossensorial Mista , Perda Auditiva Neurossensorial , Perda Auditiva , Percepção da Fala , Adulto , Humanos , Criança , Condução Óssea , Audição , Perda Auditiva Condutiva-Neurossensorial Mista/cirurgia , Perda Auditiva Condutiva/cirurgia , Surdez/cirurgia , Perda Auditiva/cirurgia , Perda Auditiva Neurossensorial/cirurgia , Resultado do Tratamento , Estudos Multicêntricos como Assunto
6.
Int J Audiol ; : 1-8, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37656611

RESUMO

OBJECTIVE: The goal of this study was to determine open field stapedius reflex thresholds (oSRTs) in CI patients with fittings based on subjective loudness ratings. A further objective was to compare these oSRTs and those of eSRT-based fittings that are similar to the oSRTs of normal hearing. DESIGN: Impedance measurements of the ear drum were taken while subjects were wearing their audio processors. The stapedius reflex was elicited by electrical stimulation transmitted through the activated CI system in response to an acoustic stimulus presented in the free sound field. STUDY SAMPLE: Subjects were 50 experienced CI users (n = 57 ears) with CI fittings based on subjective loudness scaling. RESULTS: A reference range for the oSRTs was defined that was identified in CI patients with eSRT-based fittings. Sound levels for stapedius reflex detection were inside the reference target range in 70% of the cases, below the reference range (i.e. down to 40 dB HL) in 20% of the cases, and above the reference range in 10% of the cases. CONCLUSION: Stapedius reflex detection in a free sound field may help detect fittings with too high or too low stimulation levels that might reduce audiological performance.

7.
Transpl Int ; 35: 10355, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35651880

RESUMO

Normothermic machine perfusion (NMP) allows for ex vivo viability and functional assessment prior to liver transplantation (LT). Hyperspectral imaging represents a suitable, non-invasive method to evaluate tissue morphology and organ perfusion during NMP. Liver allografts were subjected to NMP prior to LT. Serial image acquisition of oxygen saturation levels (StO2), organ hemoglobin (THI), near-infrared perfusion (NIR) and tissue water indices (TWI) through hyperspectral imaging was performed during static cold storage, at 1h, 6h, 12h and at the end of NMP. The readouts were correlated with perfusate parameters at equivalent time points. Twenty-one deceased donor livers were included in the study. Seven (33.0%) were discarded due to poor organ function during NMP. StO2 (p < 0.001), THI (p < 0.001) and NIR (p = 0.002) significantly augmented, from static cold storage (pre-NMP) to NMP end, while TWI dropped (p = 0.005) during the observational period. At 12-24h, a significantly higher hemoglobin concentration (THI) in the superficial tissue layers was seen in discarded, compared to transplanted livers (p = 0.036). Lactate values at 12h NMP correlated negatively with NIR perfusion index between 12 and 24h NMP and with the delta NIR perfusion index between 1 and 24h (rs = -0.883, p = 0.008 for both). Furthermore, NIR and TWI correlated with lactate clearance and pH. This study provides first evidence of feasibility of hyperspectral imaging as a potentially helpful contact-free organ viability assessment tool during liver NMP.


Assuntos
Imageamento Hiperespectral , Preservação de Órgãos , Hemoglobinas , Humanos , Lactatos , Fígado/diagnóstico por imagem , Preservação de Órgãos/métodos , Perfusão/métodos , Projetos Piloto
8.
Nano Lett ; 21(21): 9247-9255, 2021 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-34709845

RESUMO

T-cells engage with antigen-presenting cells in search for antigenic peptides and form transient interfaces termed immunological synapses. Synapse topography affects receptor binding rates and the mutual segregation of proteins due to size exclusion effects. It is hence important to determine the 3D topography of the immunological synapse at high precision. Current methods provide only rather coarse images of the protein distribution within the synapse. Here, we applied supercritical angle fluorescence microscopy combined with defocused imaging, which allows three-dimensional single molecule localization microscopy (3D-SMLM) at an isotropic localization precision below 15 nm. Experiments were performed on hybrid synapses between primary T-cells and functionalized glass-supported lipid bilayers. We used 3D-SMLM to quantify the cleft size within the synapse by mapping the position of the T-cell receptor (TCR) with respect to the supported lipid bilayer, yielding average distances of 18 nm up to 31 nm for activating and nonactivating bilayers, respectively.


Assuntos
Sinapses Imunológicas , Imagem Individual de Molécula , Sinapses Imunológicas/metabolismo , Microscopia de Fluorescência/métodos , Receptores de Antígenos de Linfócitos T , Imagem Individual de Molécula/métodos , Linfócitos T
11.
Opt Express ; 25(24): 29847-29855, 2017 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-29221020

RESUMO

We present a modified configuration of a tunable Alvarez lens with a refocusing frequency of 1 kHz or more. In contrast to the classic Alvarez lens, the approach does not utilize a translational motion of two sub-lenses with respect to each other, but uses a 4f-setup to image two diffractive sub-lenses onto each other. Hereby focus tuning is achieved by rotating a galvo-mirror which affects the overlap of the two sub-lenses which together form an effective lens of refractive power which depends on the rotation angle of the galvo-mirror. We have demonstrated tuning of the optical power in a system where the diffractive Alvarez lens is realized by an LCOS-SLM. We consider our Alvarez setup especially suitable for applications where high refocusing rates are important, as for example in 3D life cell monitoring or tracking.

12.
Acta Otolaryngol ; : 1-5, 2024 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-39250174

RESUMO

BACKGROUND: Previous studies found that in patients with profound hearing loss the NEO- personality factor Openness-to-experience is lowered. OBJECTIVE: Assuming that lowered Openness-to-experience may be due to limited access to sounds, we hypothesized that levels of Openness-to-experience would increase in these patients after cochlear implantation. MATERIAL AND METHODS: Twenty adults (mean age: 61 years; active CI users) with bilateral profound hearing loss were assessed with the NEO-Five-Factor-Inventory before cochlear implantation (pre) and five years later (post). RESULTS: No significant pre-post changes in personality were seen. Both before and five years after cochlear implantation, the sample had normal age- and gender-specific mean values on the factors Extraversion, Neuroticism, Agreeableness, and Conscientiousness (T ≈ 50), but significantly lowered mean values on Openness-to-experience (T ≈ 42, p < 0.001). CONCLUSIONS AND SIGNIFICANCE: Cochlear implantation apparently has no (or at best very little) effect on Openness-to-experience in profoundly hearing impaired patients. While this study demonstrates once again, that high-grade hearing loss may be associated with less openness to new experiences, the reason for this association remains unclear.

13.
Otol Neurotol ; 45(3): e228-e233, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38238908

RESUMO

BACKGROUND AND OBJECTIVES: The ability to localize sounds is partly recovered in patients using a cochlear implant (CI) in one ear and a hearing aid (HA) on the contralateral side. Binaural processing seems effective at least to some extent, despite the difference between electric and acoustic stimulation in each ear. To obtain further insights into the mechanisms of binaural hearing in these listeners, localization of low- and high-frequency sounds was tested. STUDY DESIGN: The study used a within-subject design, where participants were tasked with localizing sound sources in the horizontal plane. The experiment was conducted in an anechoic chamber, where an array of seven loudspeakers was mounted along the 24 azimuthal angle span from -90° to +90°. Stimuli were applied with different frequencies: broadband noise and high- and low-frequency noise. SUBJECTS: Ten CI recipients participated in the study. All had an asymmetric hearing loss with a CI in the poorer ear and an HA on the contralateral side. MAIN OUTCOME MEASURES: Accuracy of sound localization in terms of angular error and percentage of correct localization scores. RESULTS: The median angular error was 40° in bimodal conditions for both broadband noise and high-frequency noise stimuli. The angular error increased to 47° for low-frequency noise stimuli. In the unilaterally aided condition with an HA, only a median angular error of 78° was observed. CONCLUSIONS: Irrespective of the frequency composition of the stimuli, this group of bimodal listeners showed some ability to localize sounds. Angular errors were larger than those reported in the literature for bilateral CI users or single-sided deaf listeners with a CI. In the unilateral listening condition with HA, only localization of sounds was not possible for most subjects.


Assuntos
Implante Coclear , Implantes Cocleares , Auxiliares de Audição , Localização de Som , Percepção da Fala , Humanos , Audição
14.
Diagnostics (Basel) ; 14(5)2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38473040

RESUMO

In vivo high-resolution peripheral quantitative computed tomography (HR-pQCT) studies on bone characteristics are limited, partly due to the lack of standardized and objective techniques to describe motion artifacts responsible for lower-quality images. This study investigates the ability of such deep-learning techniques to assess image quality in HR-pQCT datasets of human scaphoids. In total, 1451 stacks of 482 scaphoid images from 53 patients, each with up to six follow-ups within one year, and each with one non-displaced fractured and one contralateral intact scaphoid, were independently graded by three observers using a visual grading scale for motion artifacts. A 3D-CNN was used to assess image quality. The accuracy of the 3D-CNN to assess the image quality compared to the mean results of three skilled operators was between 92% and 96%. The 3D-CNN classifier reached an ROC-AUC score of 0.94. The average assessment time for one scaphoid was 2.5 s. This study demonstrates that a deep-learning approach for rating radiological image quality provides objective assessments of motion grading for the scaphoid with a high accuracy and a short assessment time. In the future, such a 3D-CNN approach can be used as a resource-saving and cost-effective tool to classify the image quality of HR-pQCT datasets in a reliable, reproducible and objective way.

15.
J Vis Exp ; (208)2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38975780

RESUMO

Measuring the electrically evoked stapedius reflex during the fitting of cochlear implants (CIs) provides a reliable estimation of maximum comfort levels, resulting in the programming of the CI with high hearing comfort and good speech understanding. Detection of the stapedius reflex and the required stimulation level on each implant channel is already being performed during surgery, whereby intraoperative stapedius reflexes are observed through the surgical microscope. Intraoperative stapedius reflex detection is both an indicator that the auditory nerve is responding to electrical stimulation up to the brainstem and a test for the ability to perform postoperative stapedius reflex measurements. Postoperative stapedius reflex thresholds can be used to estimate upper stimulation levels in the CI fitting process. In particular, in children or patients unable to provide feedback on loudness perception, this method avoids inadequate stimulation with the CI, which can result in poor hearing performance. In addition, overstimulation can be avoided, which could even lead to refusal to use the device.


Assuntos
Implante Coclear , Estimulação Elétrica , Estapédio , Humanos , Estapédio/fisiologia , Implante Coclear/métodos , Estimulação Elétrica/métodos , Implantes Cocleares , Reflexo Acústico/fisiologia
16.
Transplantation ; 108(2): 506-515, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37592397

RESUMO

BACKGROUND: Biliary complications (BCs) negatively impact the outcome after liver transplantation. We herein tested whether hyperspectral imaging (HSI) generated data from bile ducts (BD) on reperfusion and machine learning techniques for data readout may serve as a novel approach for predicting BC. METHODS: Tissue-specific data from 136 HSI liver images were integrated into a convolutional neural network (CNN). Fourteen patients undergoing liver transplantation after normothermic machine preservation served as a validation cohort. Assessment of oxygen saturation, organ hemoglobin, and tissue water levels through HSI was performed after completing the biliary anastomosis. Resected BD segments were analyzed by immunohistochemistry and real-time confocal microscopy. RESULTS: Immunohistochemistry and real-time confocal microscopy revealed mild (grade I: 1%-40%) BD damage in 8 patients and moderate (grade II: 40%-80%) injury in 1 patient. Donor and recipient data alone had no predictive capacity toward BC. Deep learning-based analysis of HSI data resulted in >90% accuracy of automated detection of BD. The CNN-based analysis yielded a correct classification in 72% and 69% for BC/no BC. The combination of HSI with donor and recipient factors showed 94% accuracy in predicting BC. CONCLUSIONS: Deep learning-based modeling using CNN of HSI-based tissue property data represents a noninvasive technique for predicting postoperative BC.


Assuntos
Transplante de Fígado , Humanos , Transplante de Fígado/efeitos adversos , Transplante de Fígado/métodos , Imageamento Hiperespectral , Redes Neurais de Computação , Ductos Biliares/cirurgia , Fígado/diagnóstico por imagem , Fígado/cirurgia
17.
Heliyon ; 10(4): e25844, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38375262

RESUMO

In forensic medicine, estimating human skeletal remains' post-mortem interval (PMI) can be challenging. Following death, bones undergo a series of chemical and physical transformations due to their interactions with the surrounding environment. Post-mortem changes have been assessed using various methods, but estimating the PMI of skeletal remains could still be improved. We propose a new methodology with handheld hyperspectral imaging (HSI) system based on the first results from 104 human skeletal remains with PMIs ranging between 1 day and 2000 years. To differentiate between forensic and archaeological bone material, the Convolutional Neural Network analyzed 65.000 distinct diagnostic spectra: the classification accuracy was 0.58, 0.62, 0.73, 0.81, and 0.98 for PMIs of 0 week-2 weeks, 2 weeks-6 months, 6 months-1 year, 1 year-10 years, and >100 years, respectively. In conclusion, HSI can be used in forensic medicine to distinguish bone materials >100 years old from those <10 years old with an accuracy of 98%. The model has adequate predictive performance, and handheld HSI could serve as a novel approach to objectively and accurately determine the PMI of human skeletal remains.

18.
Otol Neurotol ; 44(3): e155-e159, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36649486

RESUMO

BACKGROUND: Only few studies assessed health-related quality of life (HRQoL) in cochlear implant (CI) patients for a period of more than 2 years. Some of these studies indicated that HRQoL might decrease after that period. The goal of our study was to see whether HRQoL indeed decreases or remains stable beyond 2 years after implant activation. METHODS: Twenty-five adults (11 women, 14 men; mean age at implantation: 60 ± 19 yr) with a unilateral CI for profound hearing loss were administered two questionnaires: the Nimjegen Cochlear Implant Questionnaire and the Health Utility Index 3 (HUI 3). The Nimjegen Cochlear Implant Questionnaire total score and the HUI single-attribute utility score of Hearing are measures of hearing-specific HRQoL, whereas the HUI multiattribute utility score is a measure of generic HRQoL. The questionnaires were administered before cochlear implantation and 1, 2, and 5 years after implant activation. RESULTS: Hearing-specific HRQoL was significantly improved at 1 year after implant activation and did not significantly change thereafter. Generic HRQoL also showed significant improvement at 1 year after implant activation, but deteriorated to a clinically relevant degree thereafter. CONCLUSIONS: The significant improvement of hearing-specific HRQoL obtained from cochlear implantation was fully maintained for up to 5 years after implantation. Generic HRQoL of our CI patients, however, fluctuated over time. The decrease of generic HRQoL is supposed to reflect general age-associated health declines.


Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Percepção da Fala , Adulto , Masculino , Humanos , Feminino , Qualidade de Vida , Surdez/cirurgia , Audição , Inquéritos e Questionários , Resultado do Tratamento
19.
J Biophotonics ; 16(10): e202300189, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37494000

RESUMO

Estimating postmortem intervals (PMI) is crucial in forensic investigations, providing insights into criminal cases and determining the time of death. PMI estimation relies on expert experience and a combination of thanatological data and environmental factors but is prone to errors. The lack of reliable methods for assessing PMI in bones and soft tissues necessitates a better understanding of bone decomposition. Several research groups have shown promise in PMI estimation in skeletal remains but lack valid data for forensic cases. Current methods are costly, time-consuming, and unreliable for PMIs over 5 years. Raman spectroscopy (RS) can potentially estimate PMI by studying chemical modifications in bones and teeth correlated with burial time. This review summarizes RS applications, highlighting its potential as an innovative, nondestructive, and fast technique for PMI estimation in forensic medicine.


Assuntos
Restos Mortais , Mudanças Depois da Morte , Humanos , Análise Espectral Raman , Osso e Ossos , Sepultamento
20.
Bioengineering (Basel) ; 10(9)2023 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-37760120

RESUMO

Bone analyses using mid-infrared spectroscopy are gaining popularity, especially with handheld spectrometers that enable on-site testing as long as the data quality meets standards. In order to diagnose Staphylococcus epidermidis in human bone grafts, this study was carried out to compare the effectiveness of the Agilent 4300 Handheld Fourier-transform infrared with the Perkin Elmer Spectrum 100 attenuated-total-reflectance infrared spectroscopy benchtop instrument. The study analyzed 40 non-infected and 10 infected human bone samples with Staphylococcus epidermidis, collecting reflectance data between 650 cm-1 and 4000 cm-1, with a spectral resolution of 2 cm-1 (Agilent 4300 Handheld) and 0.5 cm-1 (Perkin Elmer Spectrum 100). The acquired spectral information was used for spectral and unsupervised classification, such as a principal component analysis. Both methods yielded significant results when using the recommended settings and data analysis strategies, detecting a loss in bone quality due to the infection. MIR spectroscopy provides a valuable diagnostic tool when there is a tissue shortage and time is of the essence. However, it is essential to conduct further research with larger sample sizes to verify its pros and cons thoroughly.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA