Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Am J Hum Genet ; 104(2): 229-245, 2019 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-30665704

RESUMO

Primary ciliary dyskinesia (PCD) is a genetic disorder in which impaired ciliary function leads to chronic airway disease. Exome sequencing of a PCD subject identified an apparent homozygous frameshift variant, c.887_890delTAAG (p.Val296Glyfs∗13), in exon 5; this frameshift introduces a stop codon in amino acid 308 of the growth arrest-specific protein 2-like 2 (GAS2L2). Further genetic screening of unrelated PCD subjects identified a second proband with a compound heterozygous variant carrying the identical frameshift variant and a large deletion (c.867_∗343+1207del; p.?) starting in exon 5. Both individuals had clinical features of PCD but normal ciliary axoneme structure. In this research, using human nasal cells, mouse models, and X.laevis embryos, we show that GAS2L2 is abundant at the apical surface of ciliated cells, where it localizes with basal bodies, basal feet, rootlets, and actin filaments. Cultured GAS2L2-deficient nasal epithelial cells from one of the affected individuals showed defects in ciliary orientation and had an asynchronous and hyperkinetic (GAS2L2-deficient = 19.8 Hz versus control = 15.8 Hz) ciliary-beat pattern. These results were recapitulated in Gas2l2-/- mouse tracheal epithelial cell (mTEC) cultures and in X. laevis embryos treated with Gas2l2 morpholinos. In mice, the absence of Gas2l2 caused neonatal death, and the conditional deletion of Gas2l2 impaired mucociliary clearance (MCC) and led to mucus accumulation. These results show that a pathogenic variant in GAS2L2 causes a genetic defect in ciliary orientation and impairs MCC and results in PCD.


Assuntos
Cílios/patologia , Transtornos da Motilidade Ciliar/genética , Transtornos da Motilidade Ciliar/fisiopatologia , Proteínas dos Microfilamentos/deficiência , Proteínas Associadas aos Microtúbulos/deficiência , Proteínas de Xenopus/deficiência , Animais , Transtornos da Motilidade Ciliar/patologia , Modelos Animais de Doenças , Éxons/genética , Feminino , Deleção de Genes , Genes Letais , Humanos , Masculino , Camundongos , Camundongos Knockout , Proteínas dos Microfilamentos/genética , Proteínas Associadas aos Microtúbulos/genética , Fenótipo , Rotação , Xenopus/embriologia , Xenopus/genética , Proteínas de Xenopus/genética
2.
Am J Respir Crit Care Med ; 192(2): 182-90, 2015 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-25909230

RESUMO

RATIONALE: Chronic bronchitis (CB) is characterized by persistent cough and sputum production. Studies were performed to test whether mucus hyperconcentration and increased partial osmotic pressure, in part caused by abnormal purine nucleotide regulation of ion transport, contribute to the pathogenesis of CB. OBJECTIVES: We tested the hypothesis that CB is characterized by mucus hyperconcentration, increased mucus partial osmotic pressures, and reduced mucus clearance. METHODS: We measured in subjects with CB as compared with normal and asymptomatic smoking control subjects indices of mucus concentration (hydration; i.e., percentage solids) and sputum adenine nucleotide/nucleoside concentrations. In addition, sputum partial osmotic pressures and mucus transport rates were measured in subjects with CB. MEASUREMENTS AND RESULTS: CB secretions were hyperconcentrated as indexed by an increase in percentage solids and total mucins, in part reflecting decreased extracellular nucleotide/nucleoside concentrations. CB mucus generated concentration-dependent increases in partial osmotic pressures into ranges predicted to reduce mucus transport. Mucociliary clearance (MCC) in subjects with CB was negatively correlated with mucus concentration (percentage solids). As a test of relationships between mucus concentration and disease, mucus concentrations and MCC were compared with FEV1, and both were significantly correlated. CONCLUSIONS: Abnormal regulation of airway surface hydration may slow MCC in CB and contribute to disease pathogenesis.


Assuntos
Bronquite Crônica/fisiopatologia , Depuração Mucociliar/fisiologia , Muco/química , Muco/fisiologia , Pressão Osmótica/fisiologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
3.
Artigo em Inglês | MEDLINE | ID: mdl-38687136

RESUMO

Background: Recent studies show e-cigarette (EC) users have increased rates of chronic bronchitic symptoms that may be associated with depressed mucociliary clearance (MCC). Little is known about the acute or chronic effects of EC inhalation on in vivo MCC. Methods: In vivo MCC was measured in young adult vapers (n = 5 males, mean age = 21) after controlled inhalation of a radiolabeled (Tc99m sulfur colloid) aerosol. Whole-lung clearance of radiolabeled deposited particles was measured over a 90-minute period for baseline MCC and associated with controlled periodic vaping over the first 60 minutes of MCC measurements. The vaping challenge was administered from a fourth generation box mod EC containing unflavored e-liquid (65% propylene glycol/35% vegetable glycerin, 3 mg/mL freebase nicotine). The challenge was administered at the start of each 10-minute interval of MCC measurements and consisted of 1 puff every 30 seconds for 5 minutes (i.e., 10 puffs for each 10-minute period for a total of 60 puffs during the initial 60 minutes of MCC measurements). Results: Compared with baseline, peripheral lung average clearance (%) over the 90 minutes of MCC measures was enhanced, associated with EC challenge, 12 (±6) versus 24 (±6), respectively (p < 0.05 by Wilcoxon signed-rank test). Conclusions: Acute enhancement of in vivo MCC during EC challenge is contrary to recent studies showing nicotine-associated slowing of ciliary beat and mucus transport at higher nicotine levels than those used here. However, our findings are consistent with an acute increase in fluid volume and mucin secretion to the bronchial airway surface that is likely short lived. Research reported in this publication was supported by the National Institutes of Health R01HL139369 and registered with ClinicalTrials.gov (NCT03700892).

4.
J Cyst Fibros ; 23(3): 457-460, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38355350

RESUMO

Many people with CF (pwCF) desire a reduction in inhaled treatment burden after initiation of elexacaftor/tezacaftor/ivacaftor. The randomized, open-label SIMPLIFY study showed that discontinuing hypertonic saline (HS) or dornase alfa (DA) was non-inferior to continuation of each treatment with respect to change in lung function over a 6-week period. In this SIMPLIFY substudy, we used gamma scintigraphy to determine whether discontinuation of either HS or DA was associated with deterioration in the rate of in vivo mucociliary clearance (MCC) in participants ≥12 years of age. While no significant differences in MCC endpoints were associated with HS discontinuation, significant improvement in whole and peripheral lung MCC was observed after discontinuing DA. These results suggest that pwCF on ETI with mild lung disease do not experience a subclinical deterioration in MCC that could later impact health outcomes after discontinuing HS, and in fact may benefit from improved MCC after stopping DA treatment.


Assuntos
Aminofenóis , Benzodioxóis , Fibrose Cística , Desoxirribonuclease I , Indóis , Depuração Mucociliar , Pirazóis , Quinolonas , Humanos , Fibrose Cística/tratamento farmacológico , Fibrose Cística/fisiopatologia , Depuração Mucociliar/efeitos dos fármacos , Masculino , Benzodioxóis/uso terapêutico , Feminino , Solução Salina Hipertônica/administração & dosagem , Aminofenóis/uso terapêutico , Desoxirribonuclease I/uso terapêutico , Desoxirribonuclease I/administração & dosagem , Indóis/uso terapêutico , Quinolonas/uso terapêutico , Adulto , Adolescente , Pirazóis/uso terapêutico , Proteínas Recombinantes/administração & dosagem , Pirróis/administração & dosagem , Resultado do Tratamento , Piridinas/uso terapêutico , Adulto Jovem , Agonistas dos Canais de Cloreto/uso terapêutico , Combinação de Medicamentos , Criança , Testes de Função Respiratória , Pirrolidinas
5.
J Cyst Fibros ; 23(1): 155-160, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37845149

RESUMO

BACKGROUND: The cystic fibrosis transmembrane conductance regulator (CFTR) modulator elexacaftor/tezacaftor/ivacaftor (E/T/I) is highly effective clinically for those with at least one F508del-CFTR allele. The effects of E/T/I on mucociliary clearance (MCC) and sputum properties are unknown. We, therefore, sought to characterize the effects of E/T/I on in vivo MCC and sputum characteristics hypothesized to impact mucus transport. METHODS: Forty-four participants ≥12 years of age were enrolled into this prospective, observational trial prior to initiation of E/T/I and had baseline measurement of MCC and characterization of induced sputum and exhaled breath condensate (EBC) samples. Study procedures were repeated after 1 month of E/T/I treatment. RESULTS: Average age was 27.7 years with baseline forced expiratory volume in 1 second (FEV1) of 78.2 % predicted. 52 % of subjects had previously been treated with a 2-drug CFTR modulator combination. The average whole lung MCC rate measured over 60 min (WLAveClr60) significantly improved from baseline to post-E/T/I (14.8 vs. 22.8 %; p = 0.0002), as did other MCC indices. Sputum% solids also improved (modeled mean 3.4 vs. 2.2 %; p<0.0001), whereas non-significant reductions in sputum macrorheology (G', G") were observed. No meaningful changes in exhaled breath condensate endpoints (sialic acid:urea ratio, pH) were observed. CONCLUSIONS: E/T/I improved the hydration of respiratory secretions (% solids) and markedly accelerated MCC. These data confirm the link between CFTR function, mucus solid content, and MCC and help to define the utility of MCC and mucus-related bioassays in future efforts to restore CFTR function in all people with CF.


Assuntos
Fibrose Cística , Indóis , Pirazóis , Piridinas , Pirrolidinas , Quinolonas , Humanos , Adulto , Fibrose Cística/diagnóstico , Fibrose Cística/tratamento farmacológico , Fibrose Cística/genética , Regulador de Condutância Transmembrana em Fibrose Cística , Depuração Mucociliar , Estudos Prospectivos , Aminofenóis/uso terapêutico , Benzodioxóis/uso terapêutico , Muco , Mutação , Agonistas dos Canais de Cloreto/uso terapêutico
6.
FASEB J ; 26(2): 533-45, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21990373

RESUMO

Cigarette smoke (CS) exposure induces mucus obstruction and the development of chronic bronchitis (CB). While many of these responses are determined genetically, little is known about the effects CS can exert on pulmonary epithelia at the protein level. We, therefore, tested the hypothesis that CS exerts direct effects on the CFTR protein, which could impair airway hydration, leading to the mucus stasis characteristic of both cystic fibrosis and CB. In vivo and in vitro studies demonstrated that CS rapidly decreased CFTR activity, leading to airway surface liquid (ASL) volume depletion (i.e., dehydration). Further studies revealed that CS induced internalization of CFTR. Surprisingly, CS-internalized CFTR did not colocalize with lysosomal proteins. Instead, the bulk of CFTR shifted to a detergent-resistant fraction within the cell and colocalized with the intermediate filament vimentin, suggesting that CS induced CFTR movement into an aggresome-like, perinuclear compartment. To test whether airway dehydration could be reversed, we used hypertonic saline (HS) as an osmolyte to rehydrate ASL. HS restored ASL height in CS-exposed, dehydrated airway cultures. Similarly, inhaled HS restored mucus transport and increased clearance in patients with CB. Thus, we propose that CS exposure rapidly impairs CFTR function by internalizing CFTR, leading to ASL dehydration, which promotes mucus stasis and a failure of mucus clearance, leaving smokers at risk for developing CB. Furthermore, our data suggest that strategies to rehydrate airway surfaces may provide a novel form of therapy for patients with CB.


Assuntos
Regulador de Condutância Transmembrana em Fibrose Cística/metabolismo , Pulmão/metabolismo , Fumar/efeitos adversos , Fumar/metabolismo , Adulto , Idoso , Animais , Sequência de Bases , Transporte Biológico Ativo , Água Corporal/metabolismo , Bronquite Crônica/etiologia , Bronquite Crônica/metabolismo , Estudos de Casos e Controles , Células Cultivadas , Cricetinae , Fibrose Cística/etiologia , Fibrose Cística/metabolismo , Fibrose Cística/terapia , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Primers do DNA/genética , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Depuração Mucociliar , Mucosa Respiratória/metabolismo , Solução Salina Hipertônica/farmacologia , Fumaça/efeitos adversos , Solubilidade
7.
Part Fibre Toxicol ; 10(1): 58, 2013 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-24245863

RESUMO

BACKGROUND: Increased susceptibility of smokers to ambient PM may potentially promote development of COPD and accelerate already present disease. OBJECTIVES: To characterize the acute and subacute lung function response and inflammatory effects of controlled chamber exposure to concentrated ambient fine particles (CAFP) with MMAD ≤ 2.5 microns in ex-smokers and lifetime smokers. METHODS: Eleven subjects, aged 35-74 years, came to the laboratory 5 times; a training day and two exposure days separated by at least 3 weeks, each with a post-exposure visit 22 h later. Double-blind and counterbalanced exposures to "clean air" (mean 1.5 ± 0.6 µg/m3) or CAFP (mean 108.7 ± 24.8 µg/m3 ) lasted 2 h with subjects at rest. RESULTS: At 3 h post-exposure subjects' DTPA clearance half-time significantly increased by 6.3 min per 100 µg/m3 of CAFP relative to "clean air". At 22 h post-exposure they showed significant reduction of 4.3% per 100 µg/m3 in FEV1 and a significant DLCO decrease by 11.1% per 100 µg/m3 of CAFP relative to "clean air". At both 3 h and 22 h the HDL cholesterol level significantly decreased by 4.5% and 4.1%, respectively. Other blood chemistries and markers of lung injury, inflammation and procoagulant activity were within the normal range of values at any condition. CONCLUSIONS: The results suggest that an acute 2 h resting exposure of smokers and ex-smokers to fine ambient particulate matter may transiently affect pulmonary function (spirometry and DLCO) and increase DTPA clearance half-time. Except for a post exposure decrease in HDL no other markers of pulmonary inflammation, prothrombotic activity and lung injury were significantly affected under the conditions of exposure.


Assuntos
Poluentes Atmosféricos/farmacologia , Pulmão/fisiopatologia , Fumar/fisiopatologia , Adulto , Idoso , Feminino , Humanos , Exposição por Inalação , Masculino , Pessoa de Meia-Idade
8.
Infect Control Hosp Epidemiol ; 44(9): 1481-1484, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36912322

RESUMO

BACKGROUND: Face masks reduce disease transmission by protecting the wearer from inhaled pathogens and reducing the emission of infectious aerosols. Although methods quantifying efficiency for wearer protection are established, current methods for assessing face mask containment efficiency rely on measurement of a low concentration of aerosols emitted from an infected or noninfected individual. METHODS: A small port enabled the introduction of 0.05 µm sodium chloride particles at a constant rate behind the mask worn by a study participant. A condensation particle counter monitored ambient particle numbers 60 cm in front of the participant over 3-minute periods of rest, speaking, and coughing. The containment efficiency (%) for each mask and procedure was calculated as follows: 100 × (1 - average ambient concentration with face covering worn/average ambient concentration with a sham face covering in place). The protection efficiency (%) was also measured using previously published methods. The probability of transmission (%) from infected to uninfected (a function of both the containment efficiency and the protection efficiency) was calculated as follows: {1 - (containment efficiency/100)}×{1 - (protection efficiency/100)}×100. RESULTS: The average containment efficiencies for each mask over all procedures and repeated measures were 94.6%, 60.9%, 38.8%, and 43.2%, respectively, for the N95 mask, the KN95 mask, the procedure face mask, and the gaiter. The corresponding protection efficiencies for each mask were 99.0%, 63.7%, 45.3%, and 24.2%, respectively. For example, the transmission probability for 1 infected and 1 uninfected individual in close proximity was ∼14.2% for KN95 masks, compared to 36%-39% when only 1 individual wore a KN95 mask. CONCLUSION: Overall, we detected a good correlation between the protection and containment that a face covering afforded to a wearer.


Assuntos
Aerossóis e Gotículas Respiratórios , Dispositivos de Proteção Respiratória , Humanos , Respiradores N95 , Máscaras , Tosse
9.
PLoS One ; 17(5): e0268622, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35594286

RESUMO

BACKGROUND: Cystic fibrosis (CF) is an inherited disorder causing impaired mucociliary clearance within the respiratory tract, and is associated with bronchiectasis, chronic respiratory infections, and early death. Airway clearance therapies have long been a cornerstone of management of individuals with CF, although evidence supporting their use is lacking. We designed a randomized controlled trial to quantitatively compare the effects of different forms of airway clearance on mucociliary clearance. METHODS: Three different physiotherapy methods to augment cough-clearance were studied in addition to cough-clearance alone: high-frequency chest-wall oscillating vest, oscillatory positive expiratory pressure, and whole-body vibration. We used gamma scintigraphy after inhalation of radiolabeled particles to quantify mucus clearance before, during, and after physiotherapy. As secondary endpoints, we measured concentrations of small molecules in exhaled breath that may impact mucus clearance. RESULTS: Ten subjects were enrolled and completed study procedures. No differences were identified between any method of airway clearance, including cough clearance alone. We did identify changes in certain small molecule concentrations in exhaled breath following airway clearance. CONCLUSIONS: Due to the limitations of this study, we do not believe the negative results suggest a change in clinical practice with regard to airway clearance. Findings pertaining to small molecules in exhaled breath may serve as future opportunities for study.


Assuntos
Fibrose Cística , Depuração Mucociliar , Adulto , Tosse/complicações , Fibrose Cística/complicações , Volume Expiratório Forçado , Humanos , Muco
10.
Compr Physiol ; 12(4): 3823-3832, 2022 08 12.
Artigo em Inglês | MEDLINE | ID: mdl-35959754

RESUMO

Total and regional deposition of inhaled electronic cigarette (E-cig) particles in the respiratory tract (RT) depends on both physical properties of the inhaled particles and biological factors of users, for example, breathing pattern or puff profile, airway anatomy, and regional ventilation. Accurate particle sizing of E-cig aerosols is essential for predicting particle deposition in the RT. Studies using a variety of sizing methods have shown mass median aerodynamic diameters ranging from 0.2 to 1.2 um and secondary count diameters in the ultrafine range (<0.1 µm). Incorporating these particle sizes into a multiple-path particle dosimetry (MPPD) model shows 10% to 45% total lung deposition by mass and 30% to 80% for ultrafine particles depending on the breathing patterns. These predictions are consistent with experimental measures of deposition fraction of submicron and ultrafine particles. While box-mod-type E-cig devices allow for full "direct-lung" inhalations of aerosol, the more recent pod-based, and disposable E-cigs (e.g., JUUL, Puff Bar, Stig) deliver the aerosol as a "mouth-to-lung" puff, or bolus, that is inhaled early in the breath followed to various degrees by further inhalation of ambient air. Measurement of realistic ventilation patterns associated with these various devices may further improve deposition predictions. Finally, while in vivo measures of RT deposition present a challenge, a recent methodology to radiolabel E-cig particles may allow for such measurements by gamma scintigraphy. Supported by NIH/NHLBI R01HL139369. © 2022 American Physiological Society. Compr Physiol 12: 1-10, year.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Administração por Inalação , Aerossóis , Humanos , Pulmão/diagnóstico por imagem , Material Particulado , Sistema Respiratório/diagnóstico por imagem
11.
Am J Infect Control ; 49(9): 1206-1209, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33971283

RESUMO

Shortages of efficient filtering facepiece respirators leave the public vulnerable to transmission of infectious diseases in small particle aerosols. This study demonstrates that a high-filtration-efficiency facepiece capable of filtering out >95% of 0.05µm particles while being worn can be simply produced with available materials.


Assuntos
Exposição Ocupacional , Dispositivos de Proteção Respiratória , Aerossóis , Filtração , Humanos , Ventiladores Mecânicos
12.
J Expo Sci Environ Epidemiol ; 31(6): 953-960, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34006963

RESUMO

BACKGROUND: Globally, a large percentage of men keep a beard at least occasionally. Workplace regulations prohibit beards with N95 respirators, but there is little information on the effect of beards with face masks worn by the public for protection against SARS-CoV-2. METHODS AND FINDINGS: We examined the fitted filtration efficiency (FFE) of five commonly worn protective face masks as a function of beard length following the US Occupational Safety and Health Administration Quantitative Fit Test: N95 (respirator), KF94 and KN95, surgical/procedure, and cloth masks. A comparison using N95 respirators was carried out in shaven and bearded men. A detailed examination was conducted for beard lengths between 0 and 10 mm (0.5 mm increments). The effect of an exercise band covering the beard on FFE was also tested. Although N95 respirators showed considerable variability among bearded men, they had the highest FFE for beard lengths up to 10 mm. KF94 and KN95 masks lost up to 40% of their FFE. Procedure and cotton masks had poor performance even on bare skin (10-30% FFE) that did not change appreciably with beard length. Marked performance improvements were observed with an exercise band worn over the beard. CONCLUSIONS: Though variable, N95 respirators offer the best respiratory protection for bearded men. While KF94 and KN95 FFE is compromised considerably by increasing beard length, they proved better options than procedure and cotton face masks. A simple exercise band improves FFE for face masks commonly used by bearded men during the COVID-19 pandemic.


Assuntos
COVID-19 , Dispositivos de Proteção Respiratória , Humanos , Masculino , Máscaras , Pandemias/prevenção & controle , Equipamento de Proteção Individual , SARS-CoV-2
13.
JAMA Intern Med ; 181(4): 463-469, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33300948

RESUMO

Importance: During the coronavirus disease 2019 (COVID-19) pandemic, the general public has been advised to wear masks or improvised face coverings to limit transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). However, there has been considerable confusion and disagreement regarding the degree to which masks protect the wearer from airborne particles. Objectives: To evaluate the fitted filtration efficiency (FFE) of various consumer-grade and improvised face masks, as well as several popular modifications of medical procedure masks that are intended to improve mask fit or comfort. Design, Setting, and Participants: For this study conducted in a research laboratory between June and August 2020, 7 consumer-grade masks and 5 medical procedure mask modifications were fitted on an adult male volunteer, and FFE measurements were collected during a series of repeated movements of the torso, head, and facial muscles as outlined by the US Occupational Safety and Health Administration Quantitative Fit Testing Protocol. The consumer-grade masks tested included (1) a 2-layer nylon mask with ear loops that was tested with an optional aluminum nose bridge and filter insert in place, (2) a cotton bandana folded diagonally once (ie, "bandit" style) or in a (3) multilayer rectangle according to the instructions presented by the US Surgeon General, (4) a single-layer polyester/nylon mask with ties, (5) a polypropylene mask with fixed ear loops, (6) a single-layer polyester gaiter/neck cover balaclava bandana, and (7) a 3-layer cotton mask with ear loops. Medical procedure mask modifications included (1) tying the mask's ear loops and tucking in the side pleats, (2) fastening ear loops behind the head with 3-dimensional-printed ear guards, (3) fastening ear loops behind the head with a claw-type hair clip, (4) enhancing the mask/face seal with rubber bands over the mask, and (5) enhancing the mask/face seal with a band of nylon hosiery over the fitted mask. Main Outcomes and Measures: The primary study outcome was the measured FFE of common consumer-grade and improvised face masks, as well as several popular modifications of medical procedure masks. Results: The mean (SD) FFE of consumer grade masks tested on 1 adult male with no beard ranged from 79.0% (4.3%) to 26.5% (10.5%), with the 2-layer nylon mask having the highest FFE. Unmodified medical procedure masks with ear loops had a mean (SD) FFE of 38.5% (11.2%). All modifications evaluated in this study increased procedure mask FFE (range [SD], 60.3% [11.1%] to 80.2% [3.1%]), with a nylon hosiery sleeve placed over the procedure mask producing the greatest improvement. Conclusions and Relevance: While modifications to improve medical procedure mask fit can enhance the filtering capability and reduce inhalation of airborne particles, this study demonstrates that the FFEs of consumer-grade masks available to the public are, in many cases, nearly equivalent to or better than their non-N95 respirator medical mask counterparts.


Assuntos
COVID-19/prevenção & controle , COVID-19/transmissão , Máscaras , Adulto , Fibra de Algodão , Desenho de Equipamento , Filtração/instrumentação , Humanos , Masculino , Nylons , Poliésteres , Polipropilenos , Roupa de Proteção
14.
ERJ Open Res ; 6(3)2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32802823

RESUMO

BACKGROUND: Mucus dehydration and impaired mucus clearance are common features of cystic fibrosis (CF) and chronic obstructive pulmonary disease (COPD). In CF, inhaled hypertonic saline (HS) improves lung function and produces sustained increases in mucociliary clearance (MCC). We hypothesised that administration of HS (7% NaCl) twice daily for 2 weeks would improve clinical outcomes and produce sustained increases in MCC in COPD subjects with a chronic bronchitis (CB) phenotype. METHODS: Twenty-two CB subjects completed a double-blinded, crossover study comparing inhaled HS to a hypotonic control solution (0.12% saline) administered via nebuliser twice daily for 2 weeks. Treatment order was randomised. During each treatment period, symptoms and spirometry were measured. MCC was measured at baseline, shortly after initial study agent administration, and approximately 12 h after the final dose. RESULTS: HS was safe and well tolerated but overall produced no significant improvements in spirometry or patient-reported outcomes. CB subjects had slower baseline MCC than healthy subjects. The MCC rates over 60 min (Ave60Clr) in CB subjects following 2 weeks of HS were not different from 0.12% saline but were slower than baseline (Ave60Clr was 9.1±6.3% at baseline versus 5.3±6.9% after HS; p<0.05). Subgroup analyses determined that subjects with residual baseline central lung clearance (14 subjects) had improved spirometry and symptoms following treatment with HS, but not 0.12% saline, treatment. CONCLUSIONS: Inhaled HS appeared to be safe in a general CB population. A specific phenotypic subgroup may benefit from HS but requires additional study.

15.
JAMA Intern Med ; 180(12): 1607-1612, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-32780113

RESUMO

Importance: Procuring respiratory protection for clinicians and other health care workers has become a major challenge of the coronavirus disease 2019 (COVID-19) pandemic and has resulted in nonstandard practices such as the use of expired respirators and various decontamination processes to prolong the useful life of respirators in health care settings. In addition, imported, non-National Institute for Occupational Safety and Health (NIOSH)-approved respirators have been donated or acquired by hospitals as a potential replacement for limited NIOSH-approved N95 respirators. Objective: To assess fitted filtration efficiencies (FFEs) for face mask alternatives used during the COVID-19 pandemic. Design, Setting, and Participants: For this quality-improvement study conducted between April and June 2020, we used the Occupational Safety and Health Administration's Quantitative Fit Testing Protocol for Filtering Facepiece Respirators in a laboratory atmosphere supplemented with sodium chloride particles to assess the FFEs of a variety of respirators worn by a male volunteer and female volunteer. Main Outcomes and Measures: The FFEs of respirators commonly worn by clinicians and other health care workers and available respirator alternatives during the COVID-19 pandemic. Results: Of the 29 different fitted face mask alternatives tested on 1 man and 1 woman, expired N95 respirators with intact elastic straps and respirators subjected to ethylene oxide and hydrogen peroxide sterilization had unchanged FFE (>95%). The performance of N95 respirators in the wrong size had slightly decreased performance (90%-95% FFE). All of the respirators not listed as approved in this evaluation (n = 6) failed to achieve 95% FFE. Neither of the 2 imported respirators authorized for use by the Centers for Disease Control and Prevention that were not NIOSH-approved tested in this study achieved 95% FFE, and the more effective of the 2 functioned at approximately 80% FFE. Surgical and procedural face masks had filtering performance that was lower relative to that of N95 respirators (98.5% overall FFE), with procedural face masks secured with elastic ear loops showing the lowest efficiency (38.1% overall FFE). Conclusions and Relevance: This quality-improvement study evaluating 29 face mask alternatives for use by clinicians interacting with patients during the COVID-19 pandemic found that expired N95 respirators and sterilized, used N95 respirators can be used when new N95 respirators are not available. Other alternatives may provide less effective filtration.


Assuntos
COVID-19 , Reutilização de Equipamento/normas , Filtração/normas , Controle de Infecções/instrumentação , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Máscaras , Respiradores N95 , Esterilização , COVID-19/epidemiologia , COVID-19/prevenção & controle , COVID-19/transmissão , Desinfetantes , Contaminação de Equipamentos/prevenção & controle , Análise de Falha de Equipamento/métodos , Óxido de Etileno/farmacologia , Pessoal de Saúde , Humanos , Peróxido de Hidrogênio/farmacologia , Máscaras/classificação , Máscaras/normas , Máscaras/provisão & distribuição , Teste de Materiais/métodos , Respiradores N95/normas , Respiradores N95/provisão & distribuição , Melhoria de Qualidade , SARS-CoV-2 , Esterilização/métodos , Esterilização/normas
16.
J Cyst Fibros ; 19(6): 942-948, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32669217

RESUMO

BACKGROUND: Hypertonic saline (HS) is commonly prescribed for children with cystic fibrosis (CF) despite the absence of strong data indicating clinical efficacy in a population with mild lung disease. We hypothesized that HS treatment would result in a sustained improvement in mucociliary clearance (MCC) in children with CF who had minimal lung disease, thus providing evidence for a biologically relevant effect that also may be associated with clinical improvements. METHODS: We performed a randomized, placebo controlled, double blind study of 6% versus 0.12% sodium chloride, delivered three-times daily with an eFlow nebulizer for 4 weeks. MCC was measured using gamma scintigraphy at baseline, 2-hours after the first study treatment, and ~12-hours after the final dose (at day 28). Spirometry, respiratory symptoms (CFQ-R), and safety were also assessed. RESULTS: Study treatments were generally well tolerated and safe. HS (6% sodium chloride) resulted in a significant, sustained improvement from baseline in whole lung clearance after 4 weeks of therapy (p = 0.014), despite absence of a prolonged single-dose effect after the initial dose. This sustained change (12 hrs after prior dose) was significantly greater when compared to placebo (0.12% sodium chloride) treatment (p = 0.016). Improvements in spirometry with HS did not reach statistical significance but correlated with MCC changes. CONCLUSIONS: The observed sustained improvement in MCC with HS suggests that this treatment may yield health benefits, even in relatively mildly affected children with CF. Highlighting this physiologic finding is important due to the lack of meaningful, validated endpoints in this population.


Assuntos
Fibrose Cística/tratamento farmacológico , Depuração Mucociliar/efeitos dos fármacos , Solução Salina Hipertônica/administração & dosagem , Administração por Inalação , Criança , Método Duplo-Cego , Feminino , Humanos , Masculino , Nebulizadores e Vaporizadores
17.
N Engl J Med ; 354(3): 241-50, 2006 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-16421365

RESUMO

BACKGROUND: Abnormal homeostasis of the volume of airway surface liquid in patients with cystic fibrosis is thought to produce defects in mucus clearance and airway defense. Through osmotic forces, hypertonic saline may increase the volume of airway surface liquid, restore mucus clearance, and improve lung function. METHODS: A total of 24 patients with cystic fibrosis were randomly assigned to receive treatment with inhaled hypertonic saline (5 ml of 7 percent sodium chloride) four times daily with or without pretreatment with amiloride. Mucus clearance and lung function were measured during 14-day baseline and treatment periods. RESULTS: Long-term inhalation of hypertonic saline without pretreatment with amiloride (i.e., with placebo pretreatment) resulted in a sustained (> or =8 hours) increase in 1-hour rates of mucus clearance, as compared with those with amiloride pretreatment (14.0+/-2.0 vs. 7.0+/-1.5 percent, respectively; P=0.02) and increased 24-hour rates of mucus clearance over baseline. Furthermore, inhalation of hypertonic saline with placebo improved the forced expiratory volume in one second (FEV1) between the baseline period and the treatment period (mean difference, 6.62 percent; 95 percent confidence interval, 1.6 to 11.7; P=0.02), whereas hypertonic saline with amiloride did not improve FEV1 (mean difference, 2.9 percent; 95 percent confidence interval, -2.2 to 8.0; P=0.23). Forced vital capacity (FVC), the forced expiratory flow between 25 and 75 percent of FVC (FEF25-75), and respiratory symptoms also significantly improved in patients treated with hypertonic saline and placebo, whereas the residual volume as a proportion of total lung capacity (RV:TLC) did not change in either group. A comparison of the changes in lung function in the two groups showed no significant difference. In vitro data suggested that sustained hydration of airway surfaces was responsible for the sustained improvement in mucus clearance, whereas inhibition of osmotically driven water transport by amiloride accounted for the observed loss of clinical benefit. CONCLUSIONS: In patients with cystic fibrosis, inhalation of hypertonic saline produced a sustained acceleration of mucus clearance and improved lung function. This treatment may protect the lung from insults that reduce mucus clearance and produce lung disease.


Assuntos
Amilorida/uso terapêutico , Fibrose Cística/tratamento farmacológico , Depuração Mucociliar/efeitos dos fármacos , Pré-Medicação , Solução Salina Hipertônica/administração & dosagem , Bloqueadores dos Canais de Sódio/uso terapêutico , Administração por Inalação , Adolescente , Adulto , Amilorida/farmacologia , Transporte Biológico/efeitos dos fármacos , Fibrose Cística/fisiopatologia , Feminino , Volume Expiratório Forçado/efeitos dos fármacos , Humanos , Masculino , Fluxo Máximo Médio Expiratório/efeitos dos fármacos , Permeabilidade/efeitos dos fármacos , Solução Salina Hipertônica/efeitos adversos , Solução Salina Hipertônica/farmacologia , Bloqueadores dos Canais de Sódio/farmacologia , Capacidade Vital/efeitos dos fármacos , Água/fisiologia
19.
J Aerosol Med Pulm Drug Deliv ; 32(1): 47-53, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30376396

RESUMO

BACKGROUND: Electronic cigarettes (ECIGs) are widely used, but their health effects are not well known. ECIG exposure is difficult to quantify, and a direct measurement of deposition would be beneficial to in vivo and in vitro toxicity studies. The aim of this study was to demonstrate effective radiolabeling of an ECIG. METHODS: A technetium-99m-labeled carbon ultrafine (TCU) aerosol was generated and introduced to a fourth-generation ECIG before nucleation and aerosol formation. The aerosolized e-liquid was a commercially available strawberry flavor containing 1.2% nicotine in a 55% propylene glycol and 45% vegetable glycerine base. An ECIG power setting of 100 W was selected. Mass and radioactivity were measured on each stage within a Sierra Cascade Impactor at 14 L/min to verify the labeling technique using the calculated aerodynamic diameters. A strong positive correlation (R2 > 0.95) between the percent activity and percent mass deposition on each stage provides a reliable validation of colocation. RESULTS: Unlabeled ECIG aerosol from the chosen e-liquid produced a mass median aerodynamic diameter (MMAD) of 0.85 µm. An ECIG labeled with TCU produced an aerosol with an activity median aerodynamic diameter of 0.84 µm and an MMAD of 0.84 µm. The relative mass versus radioactivity on each plate was highly correlated (average R2 = 0.973, p < 0.001). CONCLUSION: A TCU radiolabel was generated and shown to associate with the mass of an aerosol produced by a typical commercially available ECIG. Thus, the radioactivity of the deposited aerosol may be used to determine ECIG aerosol deposition for the future in vivo and in vitro dosimetry studies of the third- and fourth-generation ECIGs.


Assuntos
Carbono/química , Sistemas Eletrônicos de Liberação de Nicotina , Nicotina/química , Agonistas Nicotínicos/química , Tecnécio/química , Vaping , Administração por Inalação , Aerossóis , Carbono/administração & dosagem , Nicotina/administração & dosagem , Agonistas Nicotínicos/administração & dosagem , Tamanho da Partícula , Material Particulado , Tecnécio/administração & dosagem
20.
J Toxicol Environ Health A ; 71(3): 227-37, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18097948

RESUMO

Both the route of breathing, nasal versus oral, and the effectiveness of the nose to filter inhaled, fine particles may differ between children and adults. This study compared (1) the nasal contribution to breathing at rest and during mild to moderate exercise in children (age 6-10 yr) versus young adults and (2) the nasal deposition efficiency (NDE) of fine particles (1 and 2 microm MMAD, GSD < 1.2) under resting and light exercise breathing conditions in the same children and adults. Nasal contribution to breathing was assessed by respiratory inductance plethysmography and a nasal mask with flow meter during incremental exercise on a bicycle ergometer. Fine particle deposition fractions for nasal and oral breathing were assessed by inhalation of monodisperse carnauba wax particles and laser photometry to determine inhaled/exhaled concentrations. There was a trend for children to have a lesser nasal contribution to breathing at rest and during exercise, but the differences from adults were not statistically significant. Children did, however, have significantly decreased NDE for 2-microm particles under light exercise breathing conditions compared to adults, suggesting less efficient nasal filtering for larger particles and higher flow conditions. These results suggest that the lungs of children may be exposed to higher concentrations of inhaled, ambient particles than adults.


Assuntos
Envelhecimento/fisiologia , Exposição por Inalação , Respiração/efeitos dos fármacos , Adulto , Criança , Exercício Físico/fisiologia , Feminino , Humanos , Medidas de Volume Pulmonar , Masculino , Respiração Bucal , Tamanho da Partícula , Pletismografia , Ventilação Pulmonar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA