Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
Artif Organs ; 45(3): 271-277, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32885472

RESUMO

Venoarterial extracorporeal membrane oxygenation (VA-ECMO) serves as a conventional short-term mechanical circulatory assist to support heart and lung functions. The short-term ventricular assist devices (ST-VAD) can, on the contrary, offer only circulatory support. A combination of VAD and oxygenator (Oxy-VAD) could help overcome this potential disadvantage. This is a retrospective case note study of patients supported on ST-VAD which required adding an oxygenator for extra respiratory support. The oxygenator was introduced in the ST-VAD circuit, either on the left or the right side. Twenty-two patients with the etiology of refractory cardiogenic shock in decompensation were supported on Oxy-VAD between years 2009 and 2019 at tertiary care . All patients were classified into class-I INTERMACS with a mean SOFA Score of 14 ± 2.58. 86.4% of patients were already on mechanical support pre-ST-VAD implant, 80% on VA-ECMO. The BiVAD implant accounted for 63.6%, followed by LVAD and RVAD with 27.3% and 9.1%. Mean duration of the ST-VAD was 8.5 days. The oxygenator was introduced in 14 RVAD and 8 LVAD circuits. The oxygenator was successfully weaned in 54.5% while ST-VAD was explanted in 31.8%. Discharge to home survival was 22.7%. Oxy-VAD proves a viable, and probably, a better option to VA-ECMO in acute cardiorespiratory decompensation. It offers organ-specific tailor-made support to the right and/or left heart and/or lungs. While on Oxy-VAD support, each organ performance can be assessed independently, and the assistance of the specifically improved organ can be weaned off without discontinuing the support for the rest.


Assuntos
Reanimação Cardiopulmonar/instrumentação , Insuficiência Cardíaca/terapia , Coração Auxiliar , Oxigenadores , Insuficiência Respiratória/terapia , Adulto , Idoso , Reanimação Cardiopulmonar/métodos , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Escores de Disfunção Orgânica , Estudos Prospectivos , Insuficiência Respiratória/complicações , Insuficiência Respiratória/diagnóstico , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
2.
Artif Organs ; 42(12): 1125-1131, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30443997

RESUMO

Left ventricular assist device (LVAD) is now a routine therapy for advanced heart failure. Minimally invasive approach via thoracotomy for LVAD implantation is getting popular due to its potential advantage over the conventional sternotomy approach in terms of reduced risk at re-operation due to sternal sparing. We compared the approaches (thoracotomy and sternotomy) to determine the superiority. Minimally invasive approach involved fitting of the LVAD inflow cannula into left ventricle apex via left anterior thoracotomy and anastomosis of outflow graft to ascending aorta via right anterior thoracotomy. In the sternotomy approach, both the procedures were performed via sternotomy. Outcomes in patients after LVAD implantation were compared depending on these approaches for the surgery. Two hundred and five continuous flow LVAD implantations performed between July 2006 and June 2015 at a single center were divided based on surgical approach, that is, sternotomy (n = 180) and thoracotomy (n = 25) groups. There was no significant difference between the groups in relation to patient demographics, preoperative hemodynamic parameters, laboratory markers, or risk factors. There was no significant difference between the groups in terms of postoperative hemodynamic parameters, laboratory markers, bleeding and requirement of blood products, intensive care unit, and hospital stay or complications of LVAD surgery. There were no significant differences in terms of long-term survival (Log-Rank P = 0.953), however, thoracotomy, compared to sternotomy approach, incurred significantly less requirement of temporary right ventricular assist (4 vs. 19.4%, P = 0.041). Minimally invasive bilateral thoracotomy approach for LVAD implantation in addition to benefits of sternal sparing avoids dilatation of right ventricle and reduces chances of right ventricular failure requiring temporary right ventricular assist.


Assuntos
Coração Auxiliar , Implantação de Prótese/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/estatística & dados numéricos , Estudos Retrospectivos , Esternotomia/estatística & dados numéricos , Toracotomia/estatística & dados numéricos
3.
Perfusion ; 32(2): 171-173, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27625335

RESUMO

Spontaneous left main coronary artery dissection is a rare cause of acute coronary events or sudden cardiac death, constituting less than 1% of all epicardial coronary artery dissections. It is often fatal and is mostly recognized at post-mortem examination in young victims of sudden death. More than 70% of the reported cases occurred in women, particularly during pregnancy and the peripartum period and those on oral contraceptives. The clinical presentation is highly variable and prognosis varies widely, depending predominantly on the speed of diagnosis. Treatment options include medical therapy, revascularization with coronary artery bypass grafting (CABG) or percutaneous coronary intervention (PCI) and mechanical circulatory support in cases of cardiogenic shock. We report a case of spontaneous dissection of the left main stem coronary artery, with extension into the left coronary territory, which occurred in a 41-year-old lady, complicated by profound cardiogenic shock requiring recovery with extracorporeal mechanical circulatory support after salvage myocardial revascularization.


Assuntos
Anomalias dos Vasos Coronários/complicações , Anomalias dos Vasos Coronários/terapia , Vasos Coronários/patologia , Oxigenação por Membrana Extracorpórea/métodos , Choque Cardiogênico/complicações , Choque Cardiogênico/terapia , Doenças Vasculares/congênito , Adulto , Ponte de Artéria Coronária/métodos , Anomalias dos Vasos Coronários/diagnóstico , Anomalias dos Vasos Coronários/cirurgia , Vasos Coronários/cirurgia , Feminino , Humanos , Miocárdio/patologia , Intervenção Coronária Percutânea/métodos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/cirurgia , Doenças Vasculares/complicações , Doenças Vasculares/diagnóstico , Doenças Vasculares/cirurgia , Doenças Vasculares/terapia
4.
Clin Transplant ; 30(4): 421-8, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26840975

RESUMO

BACKGROUND: Limited data are available about lung transplantation (LTx) from donors suffering cardiac arrest (CA) prior to actual donation. METHODS: A retrospective analysis of LTx performed between January 2007 and September 2012 was done with the focus on CA in donors. The recipients were grouped depending on the history of donor CA and CA duration (downtime) as: No cardiac arrest ("NoCA"), CA downtime less than 20 min ("CA < 20"), and CA downtime equal to or more than 20 min ("CA > 20"). Early and mid-term outcomes after LTx were compared among the three groups. RESULTS: A total of 237 LTx were performed during the study period. One hundred eighty-eight patients received organs from "NoCA" donors, 25 from "CA < 20" donors, and 24 patients from "CA > 20" donors. There was a trend toward better overall cumulative survival in both CA groups (log rank p = 0.076) whereas the survival in the "CA > 20" group was significantly better than in the "NoCA" group in the subgroup analysis (log rank p = 0.045). Freedom from bronchiolitis obliterans syndrome (BOS) also increased with increase in CA duration, although it did not reach statistical significance. CONCLUSIONS: Transplantation of lungs from donors with a history of CA is safe and feasible. Longer duration of cardiac arrest may improve the outcomes after the LTx in terms of survival and freedom from BOS.


Assuntos
Seleção do Doador , Parada Cardíaca , Pneumopatias/cirurgia , Transplante de Pulmão , Complicações Pós-Operatórias , Doadores de Tecidos , Adulto , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo
5.
J Surg Res ; 195(1): 311-4, 2015 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-25617972

RESUMO

BACKGROUND: Donation after cardiocirculatory death (DCD) has lead to an increase in organ availability. However, because of medical, logistic, and ethical issues, the use of hearts from DCD donors for transplantation is not generally considered to be feasible. In this study, we investigated the feasibility of ex vivo resuscitation and assessment of the porcine heart after circulatory death using the organ care system (OCS). METHODS: Cardiocirculatory death was induced in five pigs by cessation of mechanical ventilation. No heparin was administered. The agonal time (AT) was calculated as the time between a reduction of blood pressure <50 mm Hg or a fall in saturation beneath 70% and the cessation of electrical activity. After a further 15 min of warm ischemia, hearts were procured and implanted into the OCS, mimicking the actual clinical scenario for other organs. Thus, procured grafts were assessed ex vivo over a period of 4 h. RESULTS: Four hearts were successfully resuscitated on the system (AT 8, 15, 20, and 34 min) Three grafts had excellent visual contractility and lactate trends and were considered to be transplantable. One graft (AT 34 min) had an increased lactate and abnormal contractility being unsuitable for transplantation. One heart with 48-min AT could not be resuscitated. CONCLUSIONS: Our data show that hearts from nonheparinized DCD porcine donors can be successfully resuscitated using the OCS in a scenario, which closely simulates clinical conditions.


Assuntos
Morte , Preservação de Órgãos , Perfusão/métodos , Animais , Ácido Láctico/análise , Masculino , Modelos Animais , Suínos , Obtenção de Tecidos e Órgãos
6.
Clin Transplant ; 29(4): 383-92, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25659973

RESUMO

OBJECTIVES: Lung transplantation (LTx) remains the definitive treatment for end-stage lung failure, whereas chronic obstructive pulmonary disease (COPD) represents one of the main diagnoses leading to the indication for a transplant. We sought to assess long-term outcomes after LTx in patients diagnosed with COPD and analyze factors influencing outcome in this frequent patient cohort. METHODS: Between January 2007 and November 2013, a total of 88 LTx were performed in patients with COPD in our institution. Patients with emphysema associated with alpha1-antitrypsin deficiency were excluded from this observation. The study design was a retrospective review of the prospectively collected data. A large number of pre-, intra-, and postoperative variables were analyzed including long-term survival and freedom from bronchiolitis obliterans syndrome (BOS). Furthermore, impact of different variables on survival was analyzed. RESULTS: Preoperative donor data indicated a large proportion of marginal donors. While the overall cumulative survival after six yr was 57.4%, the results in terms of BOS-free survival in long-term follow-up were 39.7% after six yr. Patients with COPD were also associated with a low incidence (2.3%) of the need for postoperative extracorporeal life support (ECLS). CONCLUSIONS: Long-term results after LTx in patients with COPD are acceptable with excellent survival, freedom from BOS, and low use of ECLS postoperatively despite permanently increasing proportion of marginal organs used.


Assuntos
Bronquiolite Obliterante/mortalidade , Transplante de Pulmão/mortalidade , Complicações Pós-Operatórias , Doença Pulmonar Obstrutiva Crônica/cirurgia , Adulto , Feminino , Seguimentos , Volume Expiratório Forçado , Sobrevivência de Enxerto , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida
7.
Artif Organs ; 39(2): 179-81, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25039430

RESUMO

Central extracorporeal life support (ECLS) is an effective treatment method of cardiogenic shock patients with or without lung failure. However, complications like infection and bleeding are common. The classical implantation approach requires full sternotomy, mobilization of the heart, with the well-known risks of bleeding and mediastinal infections. We present our minimally invasive technique for central ECLS through a nonsternotomy incision. Minimized right-sided thoracotomy is performed. Flexible arterial and venous cannulas are tunneled toward the right thoracotomy incision through the eighth intercostal space. A sewing ring is secured to the right atrium and a tube graft is anastomosed to the ascending aorta. Following full-dose heparinization, the arterial cannula is inserted with the tip into the vascular graft of the ascending aorta and the venous cannula via the ring into the right atrium. After meticulous deairing, the central ECLS is set at full flow.


Assuntos
Oxigenação por Membrana Extracorpórea/instrumentação , Coração Auxiliar , Sistemas de Manutenção da Vida/instrumentação , Choque Cardiogênico/cirurgia , Aorta/cirurgia , Cateterismo , Desenho de Equipamento , Átrios do Coração/cirurgia , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Toracotomia
8.
Artif Organs ; 39(2): 118-25, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24841499

RESUMO

The Synergy Micro-pump is the smallest implantable left ventricular assist device (LVAD) and provides partial flow support up to 4.25 L/min. It was shown that early intervention with this device can provide substantial benefits to patients with severe heart failure not yet sick enough for a full-support LVAD. However, as it can be inserted via small incisions with no need for sternotomy or cardiopulmonary bypass, it might be beneficial for selected high-risk patients. The aim of this study was to evaluate the efficacy of the Synergy Micro-pump in patients in INTERMACS class 1-2. From February 2012 to August 2013, 13 patients with severe heart failure were supported with the Synergy Pocket Micro-pump. Patients were divided into two groups according to INTERMACS class: the high-risk group (INTERMACS class 1-2) and the low-risk group (INTERMACS class 3-4). There were seven patients in INTERMACS class 1-2 and six in INTERMACS class 3-4. Patient demographics, perioperative characteristics, and postoperative outcomes were compared. There were no statistically significant differences in patient demographics, and mean support time was 108 ± 114 days in the high-risk group and 238 ± 198 days in the low-risk group. Also, there were no significant differences in perioperative characteristics or in the rate of postoperative adverse events. The overall survival was comparable between the two groups (one late death in each group, log-rank P = 0.608). Two patients from the high-risk group were upgraded to a full-support LVAD (P = 0.462) after 65 ± 84.9 days of mean support. One patient from the high-risk group and two patients from the low-risk group were successfully transplanted (P = 0.559). The use of the Synergy Micro-pump in INTERMACS 1-2 patients is feasible and is associated with similar postoperative outcome as in patients in INTERMACS 3-4. Carefully selected patients with severe heart failure could benefit due to the small size of the pump; however, further studies and medium-term follow-up are required.


Assuntos
Insuficiência Cardíaca/cirurgia , Transplante de Coração , Coração Auxiliar , Adulto , Ponte Cardiopulmonar , Feminino , Seguimentos , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Sobrevida
9.
Transpl Int ; 27(11): 1183-91, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25070600

RESUMO

Lung transplantation (LTx) from "extended donor criteria" donors may reduce significantly organ shortage. However, its influence on results remains unclear. In this study, we evaluate retrospectively the results of LTx from donors outside standard criteria: PaO2/FiO2 ratio < 300 mmHg, age over 55 years, and history of smoking > 20 pack-years. Two hundred and forty-eight patients underwent first time LTx in our institution between January 2007 and January 2013. Seventy-nine patients (Group I) received organs from "extended donor criteria" and 169 patients (Group II) from "standard donor criteria." Recipients' and donors' demographics, perioperative variables, and outcome were compared. Donors from Group I were significantly older [median (interquartile range)]: 52.5 (44;58) vs. 42 (28.5;48.5) years (P < 0.001) with lower PaO2/FiO2 ratio: 366 ± 116.1 455 ± 80.5 mmHg (P < 0.001), higher incidence of smoking history: 57.7% vs. 41.8% (P = 0.013), and more extensive smoking history: 24(15;30) vs. 10(3.75;14) pack-years (P < 0.001). Other parameters were comparable. Recipients' gender, diagnosis, percentage of patients operated on pump and receiving double LTx were also comparable. Recipients from Group I were significantly older: 50 (42;57) vs. 44 (29.5;53.5) years (P = 001). There were no differences observed in recipients' prevalence of primary graft dysfunction (PGD) grade 3 over first three postoperative days, duration of mechanical ventilation, intensive care and hospital length of stay, prevalence of rejection, and bronchiolitis obliterans syndrome (BOS). 90-day, 1-year, and 5-year survival (Group I vs. II) were also similar: 88.6% vs. 91.7%, 83.2% vs. 84.6%, and 59% vs. 68.2% (log rank P = 0.367). Carefully selected donor lungs from outside the standard acceptability criteria may expand existing donor pool with no detrimental effect on LTx outcome.


Assuntos
Seleção do Doador/métodos , Transplante de Pulmão , Doadores de Tecidos , Adulto , Morte Encefálica , Bronquiolite Obliterante/etiologia , Morte , Seleção do Doador/normas , Feminino , Rejeição de Enxerto/etiologia , Humanos , Transplante de Pulmão/efeitos adversos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Disfunção Primária do Enxerto/etiologia , Respiração Artificial , Insuficiência Respiratória/fisiopatologia , Insuficiência Respiratória/cirurgia , Estudos Retrospectivos , Fatores de Tempo , Coleta de Tecidos e Órgãos/métodos , Resultado do Tratamento
10.
Artif Organs ; 38(4): 276-81, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23981114

RESUMO

Chronic heart failure is a progressive and eventually fatal illness. Although the disease cannot be cured and treatment is symptom oriented, most of the patients benefit from optimum medical treatment. Patients with rapid deterioration in chronic advanced heart failure refractory to medical treatment need inotropic support and may need intra-aortic balloon pump to maintain circulatory support, which of course cannot be prolonged beyond a certain limit. The outcome of heart transplant and long-term ventricular assist device (VAD) in such patients is poor. The short-term mechanical circulatory support (MCS) offered to such patients not only provides effective circulatory support and stabilizes them hemodynamically, but also halts the ensuing or reverts the established end-organ failure. As the name suggests, the short-term MCS offers support for the short term, usually less than a month. Although some patients with acute heart failure experience recovery of myocardial function with short-term MCS support, others become dependent. These patients, stabilized and "stuck" with short-term MCS, can be "rescued" with long-term VAD or heart transplantation. Both the procedures, when done in this special situation, have their inherent advantages, disadvantages, and complications and hence need the careful consideration about the choice of the procedure. We have tried to elucidate this situation by considering the advantages and disadvantages of both options.


Assuntos
Insuficiência Cardíaca/cirurgia , Transplante de Coração , Coração Auxiliar , Humanos , Resultado do Tratamento
11.
Artif Organs ; 38(11): 940-4, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24788069

RESUMO

Extracorporeal membrane oxygenation (ECMO) is a temporary mechanical circulatory assist method that offers circulatory as well as respiratory support efficiently via peripheral access; however, it is liable to complications. Limb ischemia is one of the notorious complications of ECMO but can be avoided utilizing a proper distal limb perfusion method. A retrospective study of patients undergoing peripheral venoarterial (VA) ECMO for various reasons between June 2010 and December 2012 was performed. All patients were evaluated by our multidisciplinary team for suitability as candidates for ECMO. A peripheral VA-ECMO circuit was implanted via groin: inflow cannula in the femoral vein, an outflow cannula and distal-perfusion cannula, or an introducer sheath in the femoral artery. During the study period, 83 patients underwent various types of ECMO; 45 received peripheral VA-ECMO. Distal limb perfusion was achieved with an introducer sheath (6-8 Fr) in 13 cases and with a distal-perfusion cannula (10-12 Fr) in 32 cases. Nine (20%) patients developed signs of ischemia; five (11.2%) were treated conservatively, while four (8.8%) required surgical intervention. One patient required a below-knee amputation. The incidences of limb ischemia and limb ischemia requiring surgical intervention were significantly higher for the introducer sheath compared with the cannula (30.6 vs. 15.6% and 15.4 vs. 6.25%, respectively). Moreover, the patients supported on ECMO with a distal-perfusion cannula spent a significantly longer time on ECMO compared with the ones in whom an introducer sheath was used (11.9 ± 9.1 vs. 7.7 ± 4.3 days). The mean cannula size was significantly greater than the mean introducer sheath size (11.1 ± 1.3 vs. 7.0 ± 1.1 Fr). Use of a distal-perfusion cannula is a most reliable method of limb perfusion in peripheral VA-ECMO. The cannula can ensure adequate and smooth perfusion of the limb owing to its large caliber, its less turbulent flow, the ability it provides to monitor the flow, and the option to attach a side port.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Cardiopatias/terapia , Isquemia/etiologia , Perna (Membro)/irrigação sanguínea , Adulto , Cateterismo Periférico , Oxigenação por Membrana Extracorpórea/instrumentação , Feminino , Humanos , Isquemia/prevenção & controle , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
12.
J Artif Organs ; 17(4): 364-5, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24973025

RESUMO

Arthrogryposis multiplex congenita (AMC) is characterized by contractions of multiple joints present at birth. AMC is rarely associated with cardiomyopathy. We present a case of a young man with dilated cardiomyopathy associated with AMC admitted with rapidly deteriorating severe heart failure who was offered left ventricular assist device as a bridge to transplant.


Assuntos
Artrogripose/complicações , Cardiomiopatias/cirurgia , Coração Auxiliar , Adulto , Cardiomiopatias/complicações , Humanos , Masculino , Resultado do Tratamento
13.
J Artif Organs ; 17(3): 228-35, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24880478

RESUMO

Post-cardiotomy cardiogenic shock (PCCS) results in substantial morbidity and mortality, whereas refractory cases require mechanical circulatory support. The aim of this study was to evaluate factors influencing survival during short-term ventricular assist support in PCCS. In total, 154 CentriMag(®) (Thoratec; CA, USA) devices were implanted for cardiogenic shock between 2004 and 2011 out of which 31 were for PCCS. A retrospective review was performed in 31 PCCS patients who required the CentriMag short-term VAD as a bridge to decision. Survivors and non-survivors were compared with respect to pre- and intra-operative characteristics as well as duration of short-term VAD support. Mean duration of support was 11.7 ± 15.4 days (range 1-65 days). Seventeen (54.83 %) patients died on support, 14 (45.16 %) were weaned off or upgraded to long-term device, while 11 (35.5 %) were discharged home. The overall survival to myocardial recovery and device explantation, or upgrade to a long-term VAD, was 41.9 % (n = 13) at the study cutoff. EuroSCORE II was significantly higher in non-survivors as compared to survivors (p = 0.047). The duration of short-term VAD support was significantly longer in survivors (p < 0.001). The CentriMag is a versatile, safe and effective short-term circulatory support for patients with PCCS as a bridge to decision which enables longer support and better recovery of both heart and end-organ function and thus may improve the survival of PCCS patients. Lower EuroSCORE may be essential for myocardial recovery in PCCS.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Complicações Pós-Operatórias/mortalidade , Choque Cardiogênico/terapia , Desenho de Equipamento , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Choque Cardiogênico/mortalidade , Taxa de Sobrevida/tendências , Resultado do Tratamento , Reino Unido/epidemiologia
14.
Heart Surg Forum ; 16(4): E208-9, 2013 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-23958533

RESUMO

Myocarditis is a known extraintestinal manifestation of inflammatory bowel diseases, but it rarely leads to acute cardiac pump failure. We report a case of fulminant myocarditis associated with ulcerative colitis treated successfully with an extracorporeal membrane oxygenator.


Assuntos
Colite Ulcerativa/complicações , Colite Ulcerativa/terapia , Oxigenação por Membrana Extracorpórea/métodos , Miocardite/etiologia , Miocardite/terapia , Adulto , Colite Ulcerativa/diagnóstico , Diagnóstico Diferencial , Humanos , Masculino , Miocardite/diagnóstico , Resultado do Tratamento
16.
Artigo em Inglês | MEDLINE | ID: mdl-33904268

RESUMO

Ex vivo lung perfusion is an indispensable tool in the armamentarium of any lung transplant center. It helps to increase an already shrinking donor pool by offering a chance to assess suboptimal donor lungs in a systematic manner and improve them by treating them with low-molecular-weight perfusate. We offer a stepwise guide to carry out ex vivo lung perfusion on the donor lungs and criteria to accept them for transplants.


Assuntos
Seleção do Doador/métodos , Circulação Extracorpórea/métodos , Transplante de Pulmão , Pulmão/fisiologia , Preservação de Órgãos/métodos , Perfusão/métodos , Humanos , Pulmão/patologia , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Doadores de Tecidos
18.
J Thorac Dis ; 11(Suppl 6): S929-S937, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31183172

RESUMO

BACKGROUND: Idiopathic pulmonary artery hypertension (iPAH) is a relatively minor indication for lung transplantation (LTx) with comparatively poorer outcomes. Extracorporeal life support (ECLS) in various forms is increasingly being used in the management of this entity. However, the data and experience with this therapy remains limited. We evaluated the role of ECLS in the management of severe iPAH patients as a bridge to LTx as well as post LTx support. METHODS: A retrospective analysis of iPAH patients that received LTx between January 2007 and May 2014 was performed. Early- and mid-term outcomes were analyzed for this patient cohort. Also, early and mid-term outcomes after LTx were compared to the control group of patients with other diagnoses using unadjusted analysis and 1:3 propensity score matching. RESULTS: Of 321 LTx performed during the study period in our centre 15 patients had iPAH as a cause of end-stage lung disease. Four iPAH (27%) patients were bridged to LTx utilizing ECLS in the form of veno-arterial ECMO and extra-corporeal CO2 removal device, whereas 9 patients (60%) required ECLS support for primary graft dysfunction (PGD) after surgery. Patients with iPAH required more frequently on-pump LTx, both pre and post LTx ECLS, and had significantly lower pO2/FiO2 ratio at 24, 48 and 72 hours after LTx. Also iPAH patients had significantly longer ICU and hospital stay. Whereas the incidence of postoperative bronchiolitis obliterans syndrome (BOS) and rejection was comparable to the control group, overall cumulative survival with up to 6 years follow-up was significantly poorer in the iPAH group. After propensity score matching, the results in terms of postoperative outcomes remained as in the unadjusted analysis. CONCLUSIONS: ECLS is an essential tool in the armamentarium of any lung transplant program treating iPAH with a potential of bridge patients to transplantation and to overcome graft dysfunction after LTx. Despite utilization of ECLS in the management of iPAH, the outcomes in terms of primary graft failure and survival remain poor compared to patients with other diagnoses.

20.
Medicine (Baltimore) ; 97(14): e0064, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29620623

RESUMO

In the context of limited donor pool in cardiothoracic transplantation, utilization of organs from high risk donors, such as suicidal hanging donors, while ensuring safety, is under consideration. We sought to evaluate the outcomes of lung transplantations (LTx) that use organs from this group.Between January 2011 and December 2015, 265 LTx were performed at our center. Twenty-two recipients received lungs from donors after suicidal hanging (group 1). The remaining 243 transplantations were used as a control (group 2). Analysis of recipient and donor characteristics as well as outcomes was performed.No statistically significant difference was found in the donor characteristics between analyzed groups, except for higher incidence of cardiac arrest, younger age and smoking history of hanging donors (P < .001, P = .022 and P = .0042, respectively). Recipient preoperative and perioperative characteristics were comparable. Postoperatively in group 1 there was a higher incidence of extracorporeal life support (27.3 vs 9.1%, P = .019). There were no significant differences in chronic lung allograft dysfunction-free survival between group 1 and 2: 92.3 vs 94% at 1 year and 65.9 vs 75.5% at 3 years (P = .99). The estimated cumulative survival rate was also similar between groups: 68.2 vs 83.2% at 1 year and 68.2% versus 72% at 3 years (P = .3758).Hanging as a donor cause of death is not associated with poor mid-term survival or chronic lung allograft dysfunction following transplantation. These results encourage assessment of lungs from hanging donors, and their consideration for transplantation.


Assuntos
Asfixia , Transplante de Pulmão/estatística & dados numéricos , Suicídio , Doadores de Tecidos/provisão & distribuição , Obtenção de Tecidos e Órgãos/métodos , Adulto , Estudos de Casos e Controles , Causas de Morte , Feminino , Humanos , Transplante de Pulmão/mortalidade , Masculino , Estudos Prospectivos , Taxa de Sobrevida , Resultado do Tratamento , Reino Unido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA